Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 28(5): 1227-32, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25281041

RESUMO

OBJECTIVE: UFH (unfractionated heparin) and protamine are integral to cardiac surgery, and inappropriate dosing can predispose to coagulopathy and hemorrhage. The FDA (Food and Drug Administration) recently has instituted changes to UFH formulation and it is not known if this has influenced its susceptibility to neutralization by protamine. Hence, the authors sought to compare 2 commercial preparations of UFH (old and new) with regard to their neutralization by protamine in patients undergoing cardiopulmonary bypass (CPB). DESIGN: Prospective, observational, cohort study. SETTING: Tertiary care university hospital and associated research laboratory PARTICIPANTS: Twenty adult patients undergoing elective cardiac surgery with CPB. INTERVENTIONS: Blood samples were drawn preinduction, prior to, and 5 and 30 minutes following protamine, and 0 and 2 hours after ICU admission. Protamine titration assays were conducted in vitro on samples drawn prior to and following protamine administration. Anti-IIa and anti-Xa activity were assayed in all samples. RESULTS: Anti-IIa and anti-Xa activity were detected ubiquitously at all time points following CPB, and there were no differences in susceptibility to protamine neutralization between the 2 groups. In vitro protamine titration studies revealed that anti-IIa was more resistant to protamine neutralization compared to anti-Xa activity. CONCLUSIONS: The 'old' and 'new' formulations of UFH evaluated in this study were similar in their susceptibility to protamine neutralization. Circulating UFH is detected as early as 5 minutes after protamine administration and anti-IIa is more resistant to protamine neutralization as compared to anti-Xa activity. Further studies are required to quantify the precise dose of protamine following CPB.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Heparina/normas , Heparina/uso terapêutico , Protaminas/normas , Protaminas/uso terapêutico , Idoso , Animais , Procedimentos Cirúrgicos Cardíacos/tendências , Química Farmacêutica , Estudos de Coortes , Feminino , Heparina/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Protaminas/sangue , Padrões de Referência , Suínos
2.
Blood ; 116(25): 5716-23, 2010 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-20817849

RESUMO

Transcranial Doppler-detected high-intensity transient signals (HITS) during cardiopulmonary bypass (CPB) surgery have been associated with postoperative neurocognitive dysfunction, suggesting microemboli in the brain could be a contributing factor. HITS occur despite administration of unfractionated heparin (UFH). This study was done to determine whether antithrombin-heparin covalent complex (ATH), a more potent anticoagulant than heparin, can reduce HITS during CPB. In a pig CPB model, ATH, UFH, or UFH + antithrombin (AT) was intravenously administered to female Yorkshire pigs after sternotomy. Twenty minutes later, hypothermic CPB was initiated and continued for 1.25 hours, then normothermia was re-established for 45 minutes. Protamine sulfate was given to neutralize the anticoagulants, and pigs were allowed to recover. HITS were monitored using an arterial flow probe placed over the carotid artery. Compared with UFH (300 or 1000 U/kg), ATH reduced the number of HITS during CPB in a dose-dependent manner. AT (3 mg/kg) + UFH (300 U/kg) resulted in an intermediate HITS rate between UFH and ATH (2 mg/kg in terms of AT). Examination of brain sections for emboli formation confirmed that, similar to HITS, number of thrombi decreased in direct proportion to ATH dosage. These results support the hypotheses that the majority of HITS represent thromboemboli and that ATH reduces emboli formation during CPB.


Assuntos
Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Ponte Cardiopulmonar/efeitos adversos , Embolia Aérea/prevenção & controle , Heparina/uso terapêutico , Ultrassonografia Doppler Transcraniana , Animais , Coagulação Sanguínea/efeitos dos fármacos , Encéfalo/efeitos dos fármacos , Encéfalo/patologia , Embolia Aérea/diagnóstico , Feminino , Sus scrofa
3.
Langmuir ; 28(4): 2099-106, 2012 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-22149666

RESUMO

Polyurethane (PU) was modified using isocyanate chemistry to graft polyethylene oxide (PEO) of various molecular weights (range 300-4600). An antithrombin-heparin (ATH) covalent complex was subsequently attached to the free PEO chain ends, which had been functionalized with N-hydroxysuccinimide (NHS) groups. Surfaces were characterized by water contact angle and X-ray photoelectron spectroscopy (XPS) to confirm the modifications. Adsorption of fibrinogen from buffer was found to decrease by ~80% for the PEO-modified surfaces compared to the unmodified PU. The surfaces with ATH attached to the distal chain end of the grafted PEO were equally protein resistant, and when the data were normalized to the ATH surface density, PEO in the lower MW range showed greater protein resistance. Western blots of proteins eluted from the surfaces after plasma contact confirmed these trends. The uptake of ATH on the PEO-modified surfaces was greatest for the PEO of lower MW (300 and 600), and antithrombin binding from plasma (an indicator of heparin anticoagulant activity) was highest for these same surfaces. The PEO-ATH- and PEO-modified surfaces also showed low platelet adhesion from flowing whole blood. It is concluded that for the PEO-ATH surfaces, PEO in the low MW range, specifically MW 600, may be optimal for achieving an appropriate balance between resistance to nonspecific protein adsorption and the ability to take up ATH and bind antithrombin in subsequent blood contact.


Assuntos
Antitrombinas/química , Antitrombinas/farmacologia , Heparina/química , Adesividade Plaquetária/efeitos dos fármacos , Polietilenoglicóis/química , Poliuretanos/química , Adsorção , Antitrombinas/metabolismo , Fibrinogênio/química , Heparina/metabolismo , Humanos , Peso Molecular , Propriedades de Superfície , Água/química
4.
Biointerphases ; 17(2): 021005, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35477241

RESUMO

Biomaterials used for blood contacting devices are inherently thrombogenic. Antithrombotic agents can be used as surface modifiers on biomaterials to reduce thrombus formation on the surface and to maintain device efficacy. For quality control and to assess the effectiveness of immobilization strategies, it is necessary to quantify the surface-immobilized antithrombotic agent directly. There are limited methods that allow direct quantification on device surfaces such as catheters. In this study, an enzyme immunoassay (EIA) has been developed to measure the density of a synthetic antithrombin-heparin (ATH) covalent complex immobilized on a catheter surface. The distribution of the immobilized ATH was further characterized by an immunohistochemical assay. This analyte-specific EIA is relatively simple and has high throughput, thus providing a tool for quantitative analysis of biomaterial surface modifications. These methods may be further modified to evaluate plasma proteins adsorbed and immobilized on various biomaterial surfaces of complex shapes, with a range of bioactive functionalities, as well as to assess conformational changes of proteins using specific antibodies.


Assuntos
Heparina , Proteínas de Membrana , Antitrombinas/química , Materiais Biocompatíveis , Fibrinolíticos , Heparina/química , Proteínas Imobilizadas , Propriedades de Superfície
5.
Thromb Haemost ; 102(2): 302-8, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19652880

RESUMO

Antithrombin (AT) is a native plasma protein that acts as the main inhibitor of enzymes generated by the coagulation cascade. In extreme thrombotic conditions, consumption of plasma AT can make treatment with AT-associated heparin therapies less effective. Supplementation with recombinant human AT (rhAT) has shown promise but altered pharmacokinetics were observed when comparing stable heparin complexes of the plasma-derived AT (pAT) and rhAT proteins. To understand the differential clearance mechanisms, biodistribution of rhAT and pAT was determined. (125)I-labelled ATryn (rhAT) or Kybernin P (pAT) was intravenously injected into rabbits. At various time points, animals were sacrificed and organs analysed for bound radioactivity. (131)I-albumin, injected shortly before termination, was used as a marker for trapped blood. Levels of circulating protein + metabolites were significantly less for rhAT than pAT (p < 0.001) and removal of acid soluble fragments confirmed that differences were due to more rapid rhAT clearance. More rhAT (28% dose) than pAT (3% dose) was liver-associated by the earliest time points, corresponding to elevated rhAT degradation products in urine/feces. However, at intermediate times (4 hours), rhAT showed significantly increased arterial and venous uptake over pAT (p

Assuntos
Antitrombinas/farmacocinética , Animais , Anticoagulantes/administração & dosagem , Antitrombinas/administração & dosagem , Antitrombinas/isolamento & purificação , Vasos Sanguíneos/metabolismo , Heparina/administração & dosagem , Humanos , Masculino , Coelhos , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/farmacocinética , Trombose/sangue , Trombose/tratamento farmacológico , Trombose/metabolismo , Distribuição Tecidual
6.
Thromb Haemost ; 102(1): 62-8, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19572069

RESUMO

We have developed an antithrombin-heparin covalent complex (ATH) which inhibits coagulation enzymes by two mechanisms: directly, or by catalytic activation of plasma antithrombin (AT). Anticoagulation by ATH was compared to unfractionated heparin (UFH) or low-molecular-weight heparin (LMWH) using a blood-based, tissue factor (TF)-activated thrombelastography (TEG) assay. Simplified TEG assays with plasma or purified plasma components were used to determine the contribution of the direct and catalytic mechanisms to ATH efficacy. Low anti-Xa concentrations of UFH inhibited clot formation significantly more than equivalent concentrations of ATH or LMWH in blood and plasma. ATH had reduced ability to catalyse AT-mediated thrombin (IIa) inhibition compared to UFH. However, at high anti-Xa concentrations, ATH had similar anticoagulant activity to UFH. ATH and non-covalent AT+UFH directly inhibited clotting to a similar degree in AT-deficient plasma. IIa-ATH complexes, which are limited to catalytic inhibition, displayed impaired anticoagulation compared to free ATH, and the magnitude of this effect increased significantly as anticoagulant concentration increased. Kinetic experiments indicated that the rate of reaction of AT with IIa is lower when catalysed by ATH versus UFH. In conclusion, at low anti-Xa doses catalytic inhibition is the primary mechanism of ATH anticoagulation, and the catalytic potential of ATH is reduced relative to UFH. However, the direct inhibitory activity of ATH is comparable to non-covalent AT+UFH, and at high anti-Xa doses the direct inhibitory activity of ATH may play a larger role in anticoagulation.


Assuntos
Anticoagulantes/metabolismo , Antitrombinas/metabolismo , Coagulação Sanguínea/efeitos dos fármacos , Heparina de Baixo Peso Molecular/metabolismo , Tromboelastografia/efeitos dos fármacos , Anticoagulantes/farmacologia , Antitrombinas/farmacologia , Catálise , Relação Dose-Resposta a Droga , Fibrinogênio/metabolismo , Heparina de Baixo Peso Molecular/farmacologia , Humanos , Plasma
7.
Cell Biochem Biophys ; 77(4): 335-342, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31489526

RESUMO

Alpha-2-macroglobulin (A2M) is a glycosylated broad spectrum inhibitor of numerous proteases, including those involved in blood coagulation. Glycosylation characteristics can affect protein structure and function. This study compares glycosylation characteristics of A2M in newborn umbilical cord (NUCP) and adult pooled plasmas. Peptide N-Glycosidase F treatment was used to evaluate the total N-glycan content of the molecules. Neuraminidase treatment, and affinity for Ricinus Communis Agglutinin I were used to examine terminal sialic acid and galactose content, respectively. Two-dimensional (2D) electrophoresis was used to determine charge-related isoform profiles and fluorophore-assisted carbohydrate electrophoresis (FACE) was used to characterize N-glycan profiles. Results revealed no difference in total N-glycan mass, however, a statistically significant difference was shown in the change in charge associated with sialic acid loss in the NUCP A2M population. 2D electrophoresis indicated a lower pI range for NUCP A2M isoforms. In addition, NUCP A2M displayed a trend toward higher terminal galactose quantities than adult A2M. FACE revealed an increased abundance of more branched, higher molecular weight glycans in NUCP A2M. These differences in glycan branching and charged residues may impact A2M receptor-based clearance and thus could be responsible for the increased A2M concentration seen in NUCP, and newborns.


Assuntos
Envelhecimento , Polissacarídeos/análise , alfa 2-Macroglobulinas Associadas à Gravidez/metabolismo , Adulto , Eletroforese em Gel Bidimensional , Glicosilação , Humanos , Recém-Nascido , alfa 2-Macroglobulinas Associadas à Gravidez/análise , Isoformas de Proteínas/metabolismo , Cordão Umbilical/metabolismo
8.
Thromb Res ; 122(3): 418-26, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18206217

RESUMO

INTRODUCTION: Activated protein C (APC) is well-established as a physiologically important anticoagulant. During development, plasma concentrations of protein C and alpha(2)macroglobulin, factors involved in APC generation, differ from adult levels. Chemotherapy drugs can perturb endothelial expression of PC-activating receptors. This study examines the effect of chemotherapy treatment of endothelium on APC generation in newborn and adult plasma. MATERIALS AND METHODS: APC generations were initiated on endothelial cells treated with vincristine or media by recalcifying defibrinated plasma with buffer containing thromboplastin. APC generation was terminated by mixing timed subsamples into FFRCMK-EDTA or heparin, followed by EDTA. APC-PCI and APC-alpha(1)AT were assayed by ELISA. APC-alpha(2)M was measured chromogenically. Since heparin converts free APC to APC-PCI, the difference between APC-PCI detected in heparin subsamples and APC-PCI detected in FFRCMK-EDTA subsamples gave the free APC. Cellular expression of EPCR and TM were measured by flow cytometry and Western blot. RESULTS: Vincristine-treated endothelium decreased free APC generation in newborn plasma to a greater degree than in adult plasma. APC-PCI levels in both adult and newborn plasma were unaffected by chemotherapy. Vincristine treatment reduced levels of APC-alpha(1) AT and APC-alpha(2) M to a greater degree in newborn plasma versus adult plasma. Expression of EPCR was reduced in cells treated with vincristine. Conversely, TM was reduced on the cell surface, but increased in whole cell lysates. CONCLUSIONS: The differential response of newborn and adult plasma PC components to chemotherapy-mediated changes in cell surface components may be a factor in the increased risk of thrombosis in children receiving chemotherapy.


Assuntos
Antineoplásicos Fitogênicos/farmacologia , Proteínas Sanguíneas/farmacologia , Células Endoteliais/efeitos dos fármacos , Proteína C/metabolismo , Trombose/prevenção & controle , Vincristina/farmacologia , Adulto , Fatores Etários , Células Cultivadas , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Humanos , Recém-Nascido , Proteínas de Membrana/metabolismo , Plasma , Ligação Proteica/efeitos dos fármacos , Inibidor da Proteína C/metabolismo , Trombomodulina/metabolismo , Trombose/induzido quimicamente , Trombose/metabolismo , Veias Umbilicais/citologia , alfa 1-Antitripsina/metabolismo , alfa-Macroglobulinas/metabolismo
9.
J Biochem ; 141(1): 25-35, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17167048

RESUMO

Antithrombin (AT) inhibition of coagulation enzymes is catalyzed by unfractionated heparin (UFH) and other heparinoids. Reaction proceeds either via conformational activation of the inhibitor or template-mediated binding of both inhibitor and protease. We investigated if the relative inhibition rates of AT + UFH and covalent AT-heparin conjugate (ATH) with coagulation factors might be indicative of the mechanism involved. Rates were determined by discontinuous assay and mechanisms were probed by a variety of binding studies with UFH or ATH heparin chains. Rates were increased more than 2-fold with ATH over AT + UFH in reactions with thrombin, factor (F) VIIa + tissue factor + Ca2+ + lipid, FIXa and FXIa, but not with FXa or FXIIa. In comparison, UFH or ATH heparin binding (evidence of a template mechanism) was only observed with thrombin, tissue factor, FIXa and FXIa. Thus, inhibition rate enhancement by conjugation of AT with heparin were predictive of inhibitor.enzyme template bridging by heparin. Rationales behind this novel concept are discussed.


Assuntos
Antitrombinas/química , Antitrombinas/metabolismo , Fatores de Coagulação Sanguínea/antagonistas & inibidores , Heparina/química , Heparina/metabolismo , Fatores de Coagulação Sanguínea/metabolismo , Fator IXa/antagonistas & inibidores , Fator IXa/metabolismo , Fator VIIa/antagonistas & inibidores , Fator VIIa/metabolismo , Fator XIa/antagonistas & inibidores , Fator XIa/metabolismo , Temperatura Alta , Cinética , Trombina/antagonistas & inibidores , Trombina/metabolismo , Tromboplastina/antagonistas & inibidores , Tromboplastina/metabolismo
10.
J Biomed Mater Res A ; 80(1): 216-25, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17072855

RESUMO

Highly anticoagulant covalent antithrombin-heparin complex (ATH) was covalently grafted onto polyurethane catheters to suppress adsorption/activation of procoagulant proteins and enhance adsorption/activation of anticoagulant proteins for blood compatibility. Consistency of catheter coating was demonstrated using immunohistochemical visualization of ATH. The ability of the resulting immobilized ATH heparin chains to bind antithrombin (AT) from plasma, as measured by binding of (125)I-radiolabeled AT, was greater than that for commercially-available heparin-coated catheters, and much greater than for uncoated catheters. Complementary measurements of antifactor Xa (FXa) activity and plasma protein binding were also performed. Both ATH-coated and heparin-coated catheters demonstrated functional binding of exogenous AT. However, the ATH-coated catheters gave a trend towards elevated anti- FXa activities/AT binding ratios, consistent with the higher active pentasaccharide content in starting ATH. Western blot analysis of proteins adsorbed to catheters after incubation with rabbit plasma established protein binding profiles that showed AT and albumin as major plasma proteins adsorbed to ATH-coated catheters, while AT and altered forms of fibrinogen were major plasma protein species adsorbed to heparinized catheters.


Assuntos
Cateterismo , Materiais Revestidos Biocompatíveis , Fibrinogênio/química , Heparina , Poliuretanos , Albumina Sérica/química , Adsorção , Animais , Antitrombinas , Coagulação Sanguínea , Materiais Revestidos Biocompatíveis/química , Fator Xa/química , Inibidores do Fator Xa , Heparina/química , Teste de Materiais , Poliuretanos/química , Ligação Proteica , Coelhos , Propriedades de Superfície
11.
Blood Coagul Fibrinolysis ; 28(6): 431-437, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27898513

RESUMO

: The clinical limitations of unfractionated heparin (UFH) and low molecular weight heparin (LMWH) led to the development of an antithrombin-heparin covalent complex (ATH), which displays superior anticoagulant abilities compared with UFH. A recent study investigating its interaction with fibrinolysis showed that ATH inhibited free and fibrin bound plasmin and decreased plasmin generation on fibrin clots. These studies were conducted using purified components and did not elucidate the interaction of ATH with plasmin in the presence of its natural inhibitors α2-antiplasmin (α2-AP) and α2-macroglobulin (α2-M). The aim of this study was to determine the effects of ATH, UFH, and LMWH on plasmin generation in plasma, under more physiological conditions. Plasmin generation in plasma in the absence and presence of anticoagulants was initiated by tissue plasminogen activator and soluble fibrin fragments, and plasmin and plasmin-α2-M complexes generated over time were quantified chromogenically. Generation of plasmin-α2-AP complexes and consumption of plasminogen were quantified by ELISA. Plasmin generation was decreased in the presence of UFH and ATH, whereas LMWH had no effect. Neither plasminogen consumption nor generation of plasmin-α2-AP complexes were affected by UFH or ATH. However, plasmin-α2-M complexes were slightly reduced by ATH suggesting that ATH may be able to compete with α2-M for plasmin. Plasmin generation may be mildly inhibited by heparin-based anticoagulants; however, heparin-catalyzed antithrombin activity is not a major inhibitor of plasmin, as compared to its natural inhibitors α2-AP and α2-M. This adds to our understanding of ATH mechanisms of action and aids in its development for clinical use.


Assuntos
Antitrombinas/farmacologia , Fibrinolisina/antagonistas & inibidores , Heparina de Baixo Peso Molecular/farmacologia , Heparina/farmacologia , Antifibrinolíticos/metabolismo , Antitrombinas/química , Fibrinolisina/metabolismo , Heparina/química , Humanos , Complexos Multiproteicos/química , Complexos Multiproteicos/farmacologia , Plasma/metabolismo , alfa 2-Macroglobulinas Associadas à Gravidez/metabolismo
12.
Blood Coagul Fibrinolysis ; 28(7): 551-557, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28505011

RESUMO

: Thromboelastography (TEG) is a global assay used for evaluating features of clot formation in vitro. Dabigatran is a reversible direct inhibitor of thrombin that has not been studied in neonates using a sophisticated global assay, such as TEG. Neonatal hemostasis differs from adult hemostasis in both quantitative and qualitative characteristics. Our aim was to compare the TEG clotting profile of neonatal and adult platelet-poor plasma when exposed to different concentrations of dabigatran. We used commercially collected adult pooled plasma and neonatal cord blood collected from placentas of healthy full term newborns. Platelet-poor plasma was isolated, pooled, and frozen. Prior to experiment, plasma was thawed and filtered. A reaction mixture of CaCl2, corn trypsin inhibitor, tissue factor, and dabigatran in imidazole buffer was mixed with plasma in a TEG cup. Time to clot initiation (R-time), speed of clot strengthening (α-angle), and maximum clot strength (maximal amplitude) were measured. Scanning electron microscopy was performed to evaluate fibrin clot structure. Without dabigatran, there was no significant difference in TEG measurements between neonatal and adult samples. However, neonatal plasma clotting with dabigatran had slower onset, slower speed, and weaker clots that were more porous with thicker fibers, compared with adult plasma clotting. Thus, neonatal plasma may be more sensitive to dabigatran as assessed by our in-vitro TEG study.


Assuntos
Antitrombinas/uso terapêutico , Dabigatrana/uso terapêutico , Tempo de Lise do Coágulo de Fibrina/métodos , Microscopia Eletrônica de Varredura/métodos , Tromboelastografia/métodos , Trombose/tratamento farmacológico , Adulto , Antitrombinas/farmacologia , Dabigatrana/farmacologia , Feminino , Humanos , Recém-Nascido , Masculino , Trombose/patologia , Adulto Jovem
13.
Lancet ; 365(9464): 1031-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15781098

RESUMO

BACKGROUND: Rapid progression to AIDS after acute HIV-1 infection, though uncommon, has been noted, as has the transmission of multidrug resistant viruses. Here, we describe a patient in whom these two factors arose concomitantly and assess the effects. METHODS: We did a case study of a patient with HIV-1 seroconversion. We genotyped the virus and host genetic markers by PCR and nucleotide sequencing. To ascertain the drug susceptibility of our patient's HIV-1 we did phenotypic studies with the PhenoSense assay. We assessed viral coreceptor use via syncytium formation in vitro and with a modified PhenoSense assay. FINDINGS: Our patient seems to have been recently infected by a viral variant of HIV-1 resistant to multiple classes of antiretroviral drugs. Furthermore, his virus population is dual tropic for cells that express CCR5 or CXCR4 coreceptor. The infection has resulted in progression to symptomatic AIDS in 4-20 months. INTERPRETATION: The intersection of multidrug resistance and rapid development of AIDS in this patient is of concern, especially in view of his case history, which includes high-risk sexual contacts and use of metamfetamine. The public health ramifications of such a case are great.


Assuntos
Síndrome da Imunodeficiência Adquirida/virologia , Farmacorresistência Viral Múltipla , Infecções por HIV/virologia , HIV-1 , Síndrome da Imunodeficiência Adquirida/tratamento farmacológico , Adulto , Contagem de Linfócito CD4 , Progressão da Doença , Infecções por HIV/tratamento farmacológico , Infecções por HIV/imunologia , HIV-1/química , HIV-1/efeitos dos fármacos , HIV-1/genética , HIV-1/fisiologia , Humanos , Masculino , Receptores CCR5/análise , Receptores CXCR4/análise , Subpopulações de Linfócitos T , Replicação Viral
14.
Thromb Haemost ; 95(4): 629-36, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16601833

RESUMO

We have developed a covalent antithrombin-heparin (ATH) complex with advantages compared to non-covalent antithrombin:heparin (AT:H) mixtures. In addition to increased activity, ATH has a longer intravenous half-life that is partly due to reduced plasma protein binding. Given ATH's altered clearance, we investigated biodistribution of ATH in vivo. ATH made from either human plasma-derived AT (pATH) or recombinant human (produced in goats) AT (rhATH) was studied. 125I-ATH + unlabeled carrier was injected into rabbits at different doses. 131I-labeled albumin was administered just before sacrifice as a marker for trapped blood in tissues. Immediately after sacrifice, animal components were removed, weighed, and subsamples were counted for gamma-radioactivity. Percent recoveries of ATH in various organs/compartments at different time points were calculated, and kinetic distribution plots generated. At saturating doses, early disappearance of rhATH from the circulation was much faster than pATH. Co-incident with clearance, 26 +/- 3% of dose for rhATH was liver-associated compared to only 3.7 +/- 0.5% for pATH by 20 min. Also, at early time periods, >60% of all extravascular ATH was liver-associated. Analysis of the vena cava and aorta suggested that vessel wall binding might also account for initial plasma loss of rhATH. By 24 h, most of pATH and rhATH were present as urinary degradation products (51 +/- 3% and 63 +/- 8%, respectively). In summary, systemic elimination of ATH is greatly influenced by the form of AT in the complex, with liver uptake and degradation playing a major role.


Assuntos
Antitrombinas/biossíntese , Heparina/biossíntese , Animais , Anticoagulantes/química , Antitrombinas/farmacocinética , Endotélio Vascular/metabolismo , Heparina/farmacocinética , Humanos , Cinética , Fígado/metabolismo , Masculino , Coelhos , Proteínas Recombinantes/química
15.
Biomaterials ; 27(29): 5107-17, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16781768

RESUMO

Covalent complexes of antithrombin (AT) and heparin (ATH) have superb anticoagulant activity towards thrombin and factor Xa. Stability of polyurethane central venous catheters covalently modified with radiolabeled ATH was studied using a roller pump with saline or protease P-5147. Saline wash removed loosely bound ATH molecules to decrease graft density from 26 to 12 pmol/cm2. However, only slightly more ATH was removed by strong protease (from 12 to 7 pmol/cm2). To evaluate ATH-coated, heparin-coated, and uncoated catheters, a chronic rabbit jugular vein model was developed with catheters maintained for up to 30-106 days. Lumen occlusion was tested by drawing blood twice daily. Although unmodified or heparin-coated catheters occluded within 5-7 days after insertion, all ATH catheters remained patent throughout the experiment. Scanning electron microscopy (SEM) analysis of heparin and uncoated catheters revealed extensive thrombosis (lumen+mural) while ATH catheters were unaffected. Visual observation showed significant deposition of protein and cells on control and heparin-modified catheters and, to a lesser degree, on ATH-coated surfaces. SEM showed no fibrin inside or outside of ATH catheters, which remained patent in extended studies out to 106 days. Although atomic force microscopy showed ATH coatings to be rough, 6-fold higher anti-factor Xa activity likely contributed to increased patency. Our data confirm that ATH-modified catheters are stable and have superior potency compared to heparin or control catheters.


Assuntos
Cateteres de Demora , Materiais Revestidos Biocompatíveis , Heparina , Veias Jugulares , Poliuretanos , Animais , Antitrombinas , Humanos , Masculino , Modelos Animais , Coelhos
16.
J Biochem ; 140(2): 175-84, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16954536

RESUMO

We have produced a molecule comprising of permanently-activated covalently linked antithrombin and heparin (ATH). This study was designed to elucidate the covalent linkage point(s) for heparin on antithrombin and conformational properties of the ATH molecule. ATH was produced using Schiff base/Amadori rearrangement by incubating antithrombin with unfractionated heparin for 14 d at 40 degrees C. ATH was then digested using Proteinase K, and the heparin-peptide was reacted with NaIO4/NaBH4/mild acid to degrade the heparin moiety. Sequencing of the remaining peptide was performed by Edman degradation with linkage point confirmation by LC-MS. The degree of insertion of the reactive center loop (RCL) of antithrombin into the A-sheet of ATH was examined using synthesized antithrombin RCL peptides. Binding between the peptides and ATH, and the formation of ATH in the presence of the peptides were tested. CD was used to further examine the secondary and tertiary structures of ATH. The results suggest that heparin is conjugated to the amino terminal of antithrombin in the majority of ATH molecules, proximal to the previously determined heparin binding domain of antithrombin. From the linkage data, a model is proposed for the structure of ATH. Studies using the RCL peptides and CD analysis of ATH support this model.


Assuntos
Heparina/química , Trombina/antagonistas & inibidores , Heparina/metabolismo , Ligação de Hidrogênio , Modelos Moleculares , Ligação Proteica , Conformação Proteica , Trombina/química
17.
Thromb Res ; 118(6): 741-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16360197

RESUMO

INTRODUCTION: Major physiological differences in the coagulation system throughout childhood, compared to adults, are well documented. However, the impact of this on anticoagulant drugs is unknown. This study aimed to determine whether heparin therapeutic range determination is affected by the age of plasma donors and whether age-specific therapeutic ranges for heparin therapy may need to be considered in the clinical setting. MATERIALS AND METHODS: Plasma samples were obtained from healthy children and adults, and pooled into age-specific pools. These were spiked with different concentrations of heparin and APTT; Anti-Factor Xa and Anti-Factor IIa were measured using standard techniques. The experiments were repeated using three separate plasma pools, and results expressed as means with standard deviations. RESULTS AND CONCLUSIONS: The results show clear age-related differences in APTT for the same Anti-Factor Xa heparin concentration. The differences were more pronounced in younger children, with higher APTT for same Anti-Factor Xa. The Anti-Factor IIa activity of heparin for a given Anti-Factor Xa activity also differed between age-specific plasma pools. This study suggests that when using heparin in children, basic assumptions about the drug mechanism of action and implications for therapeutic ranges need to be considered.


Assuntos
Heparina/farmacologia , Tempo de Tromboplastina Parcial , Terapia Trombolítica/efeitos adversos , Adolescente , Adulto , Fatores Etários , Antitrombina III/efeitos dos fármacos , Criança , Pré-Escolar , Fator Xa/efeitos dos fármacos , Heparina/sangue , Humanos , Lactente , Protrombina/efeitos dos fármacos
18.
Clin Lab ; 52(3-4): 115-24, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16584057

RESUMO

The fibrinolytic system comprises a series of serine proteases that interact to cleave fibrin into fibrin degradation products. Although all key components of the fibrinolytic system are present at birth, important age-dependent, quantitative and qualitative differences are present during childhood as compared to adults. These differences include decreased plasma concentrations of plasminogen, tissue-type plasminogen activator and alpha2-antiplasmin, increased plasma concentrations of plasminogen activator inhibitor-1, as well as a decrease in both plasmin generation and overall fibrinolytic activity. Increasing evidence suggests that these age-dependent differences may contribute to the development of specific childhood diseases and influence the course of fibrinolytic therapy, particularly in newborns. This review aims to summarize the available information on the age-dependent features of the fibrinolytic system in newborns and children in healthy and disease states and the impact of these features on fibrinolytic therapy.


Assuntos
Fatores de Coagulação Sanguínea/fisiologia , Fibrinólise/fisiologia , Serina Endopeptidases/metabolismo , Adolescente , Adulto , Fatores de Coagulação Sanguínea/efeitos dos fármacos , Criança , Pré-Escolar , Feminino , Fibrinólise/efeitos dos fármacos , Humanos , Lactente , Recém-Nascido , Masculino , Terapia Trombolítica/métodos
19.
Circulation ; 106(2): 261-5, 2002 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-12105168

RESUMO

BACKGROUND: The anticoagulant effect of heparinoids is attributed to their cofactor activity for antithrombin (AT) and heparin cofactor II. In patients with thrombosis, however, thrombin is often protected from AT-dependent, heparin-mediated inactivation. The purpose of this study was to compare the properties of unfractionated/standard heparin (UFH/SH) and those of a novel covalent AT-heparin complex (ATH) in a rabbit arterial thrombosis prevention and bleeding model. METHODS AND RESULTS: Thrombosis in the distal aorta was triggered by vessel wall injury and critical stenosis. Blood flow in the damaged arterial segment was monitored with a flow probe placed distal to the constrictor. Rabbits were given doses of SH (62.5 to 187.5 IU x kg(-1) x 90 min(-1)) or ATH (16 to 65 IU x kg(-1) x 90 min(-1)). Cumulative blood loss from skin incisions was used to assess drug safety. The antithrombotic effects of ATH were greater than those of SH as measured by clot weight, blood flow, and vessel patency; eg, complete thrombus resolution was achieved with ATH (33 to 65 IU/kg), but not SH (125.0 to 187.5 IU/kg). At doses that produced equivalent vessel patency (50% to 60%), blood loss induced by ATH (60.2 microL) was 2.6-fold lower (P<0.05) than that induced by SH (154.6 microL). CONCLUSIONS: In our experimental system, ATH was able to control arterial thrombosis more effectively than its SH precursor, without pronounced bleeding.


Assuntos
Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Artérias , Fibrinolíticos/uso terapêutico , Heparina/uso terapêutico , Trombose/prevenção & controle , Animais , Anticoagulantes/efeitos adversos , Antitrombinas/efeitos adversos , Aorta/fisiopatologia , Fibrina/metabolismo , Fibrinolíticos/efeitos adversos , Heparina/efeitos adversos , Substâncias Macromoleculares , Coelhos , Fluxo Sanguíneo Regional , Trombina/metabolismo , Trombose/fisiopatologia
20.
Thromb Haemost ; 94(2): 366-72, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16113827

RESUMO

Catheter use has been associated with an increased risk of thrombotic complications. The objective was to make catheters less thrombogenic with the use of antithrombin-heparin covalent complex (ATH). The antithrombotic activity of ATH-coated catheters was compared to uncoated (control) and heparincoated catheters in an acute rabbit model of accelerated occluding clot formation. Anaesthetized rabbits were pre-injected with rabbit (125)I-fibrinogen, followed by insertion of test catheters into the jugular vein. Blood was drawn and held in a syringe, reinjected, then flushed with saline. The experiment was terminated when blood could no longer be withdrawn (occluding clot). Efficacy was defined as the ability of catheters to remain unoccluded. Clot formation, determined by measuring deposition of radiolabeled fibrin, was a secondary endpoint. ATH-coated catheters were resistant to clotting for the full 240-minute duration, while uncoated and heparin-coated catheters had an average clotting time of 78 and 56 minutes, respectively. The patency of ATH coating was dependant on intact heparin pentasaccharide sequences, rather than the chemistries of the basecoat, the PEO spacer arm, or the antithrombin (AT) protein. The ATH coating was stable to ethylene oxide sterilization, modest abrasion, protease attack, and the coating did not appear to leach off the catheter. Surface tension measurements showed that the ATH modified surface was more hydrophilic than uncoated control catheters or heparin-coated catheters. Thus, ATH-coated catheters are better at preventing clots than uncoated or heparin-coated catheters and show promise as an alternative to the currently available catheters in reducing thrombotic complications associated with its use.


Assuntos
Antitrombinas/química , Materiais Revestidos Biocompatíveis/química , Heparina/química , Poliuretanos/farmacologia , Animais , Anticoagulantes/farmacologia , Coagulação Sanguínea , Cateterismo , Óxido de Etileno/química , Fibrina/química , Fibrinogênio/química , Humanos , Masculino , Teste de Materiais , Oxigênio/metabolismo , Polietilenoglicóis/química , Coelhos , Propriedades de Superfície , Trombose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA