Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 184
Filtrar
1.
Blood ; 143(8): 721-733, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38048591

RESUMO

ABSTRACT: The volume of oxygen drawn from systemic capillaries down a partial pressure gradient is determined by the oxygen content of red blood cells (RBCs) and their oxygen-unloading kinetics, although the latter is assumed to be rapid and, therefore, not a meaningful factor. Under this paradigm, oxygen transfer to tissues is perfusion-limited. Consequently, clinical treatments to optimize oxygen delivery aim at improving blood flow and arterial oxygen content, rather than RBC oxygen handling. Although the oxygen-carrying capacity of blood is increased with transfusion, studies have shown that stored blood undergoes kinetic attrition of oxygen release, which may compromise overall oxygen delivery to tissues by causing transport to become diffusion-limited. We sought evidence for diffusion-limited oxygen release in viable human kidneys, normothermically perfused with stored blood. In a cohort of kidneys that went on to be transplanted, renal respiration correlated inversely with the time-constant of oxygen unloading from RBCs used for perfusion. Furthermore, the renal respiratory rate did not correlate with arterial O2 delivery unless this factored the rate of oxygen-release from RBCs, as expected from diffusion-limited transport. To test for a rescue effect, perfusion of kidneys deemed unsuitable for transplantation was alternated between stored and rejuvenated RBCs of the same donation. This experiment controlled oxygen-unloading, without intervening ischemia, holding all non-RBC parameters constant. Rejuvenated oxygen-unloading kinetics improved the kidney's oxygen diffusion capacity and increased cortical oxygen partial pressure by 60%. Thus, oxygen delivery to tissues can become diffusion-limited during perfusion with stored blood, which has implications in scenarios, such as ex vivo organ perfusion, major hemorrhage, and pediatric transfusion. This trial was registered at www.clinicaltrials.gov as #ISRCTN13292277.


Assuntos
Eritrócitos , Oxigênio , Humanos , Criança , Rim
2.
Liver Transpl ; 30(1): 30-45, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109282

RESUMO

Normothermic machine perfusion (NMP) enables pretransplant assessment of high-risk donor livers. The VITTAL trial demonstrated that 71% of the currently discarded organs could be transplanted with 100% 90-day patient and graft survivals. Here, we report secondary end points and 5-year outcomes of this prospective, open-label, phase 2 adaptive single-arm study. The patient and graft survivals at 60 months were 82% and 72%, respectively. Four patients lost their graft due to nonanastomotic biliary strictures, one caused by hepatic artery thrombosis in a liver donated following brain death, and 3 in elderly livers donated after circulatory death (DCD), which all clinically manifested within 6 months after transplantation. There were no late graft losses for other reasons. All the 4 patients who died during the study follow-up had functioning grafts. Nonanastomotic biliary strictures developed in donated after circulatory death livers that failed to produce bile with pH >7.65 and bicarbonate levels >25 mmol/L. Histological assessment in these livers revealed high bile duct injury scores characterized by arterial medial necrosis. The quality of life at 6 months significantly improved in all but 4 patients suffering from nonanastomotic biliary strictures. This first report of long-term outcomes of high-risk livers assessed by normothermic machine perfusion demonstrated excellent 5-year survival without adverse effects in all organs functioning beyond 1 year (ClinicalTrials.gov number NCT02740608).


Assuntos
Transplante de Fígado , Idoso , Humanos , Constrição Patológica/etiologia , Fígado/cirurgia , Transplante de Fígado/efeitos adversos , Preservação de Órgãos , Perfusão , Estudos Prospectivos , Qualidade de Vida
3.
Nature ; 557(7703): 50-56, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29670285

RESUMO

Liver transplantation is a highly successful treatment, but is severely limited by the shortage in donor organs. However, many potential donor organs cannot be used; this is because sub-optimal livers do not tolerate conventional cold storage and there is no reliable way to assess organ viability preoperatively. Normothermic machine perfusion maintains the liver in a physiological state, avoids cooling and allows recovery and functional testing. Here we show that, in a randomized trial with 220 liver transplantations, compared to conventional static cold storage, normothermic preservation is associated with a 50% lower level of graft injury, measured by hepatocellular enzyme release, despite a 50% lower rate of organ discard and a 54% longer mean preservation time. There was no significant difference in bile duct complications, graft survival or survival of the patient. If translated to clinical practice, these results would have a major impact on liver transplant outcomes and waiting list mortality.


Assuntos
Aloenxertos/fisiologia , Transplante de Fígado/métodos , Fígado/fisiologia , Preservação de Órgãos/métodos , Temperatura , Coleta de Tecidos e Órgãos/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aloenxertos/patologia , Aloenxertos/fisiopatologia , Aloenxertos/normas , Ductos Biliares/patologia , Ductos Biliares/fisiologia , Ductos Biliares/fisiopatologia , Feminino , Sobrevivência de Enxerto , Humanos , Tempo de Internação , Fígado/enzimologia , Transplante de Fígado/efeitos adversos , Masculino , Pessoa de Meia-Idade , Preservação de Órgãos/efeitos adversos , Perfusão , Análise de Sobrevida , Doadores de Tecidos/provisão & distribuição , Coleta de Tecidos e Órgãos/efeitos adversos , Resultado do Tratamento , Listas de Espera , Adulto Jovem
4.
Am J Transplant ; 23(2): 165-170, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36695696

RESUMO

For decades, transplantation has been a life-saving treatment for those fortunate enough to gain access. Nevertheless, many patients die waiting for an organ and countless more never make it onto the waitlist because of a shortage of donor organs. Concurrently, thousands of donated organs are declined for transplant each year because of concerns about poor outcomes post-transplant. The decline of any donated organ-even if medically justified-is tragic for both the donor family and potential recipients. In this Personal Viewpoint, we discuss the need for a new mindset in how we honor the gift of organ donation. We believe that the use of transplant-declined human organs in translational research has the potential to hasten breakthrough discoveries in a multitude of scientific and medical areas. More importantly, such breakthroughs will allow us to properly value every donated organ. We further discuss the many practical challenges that such research presents and offer some possible solutions based on experiences in our own research laboratories. Finally, we share our perspective on what we believe are the necessary next steps to ensure a future where every donated organ realizes its full potential to impact the lives of current and future patients.


Assuntos
Transplante de Órgãos , Obtenção de Tecidos e Órgãos , Humanos , Doadores de Tecidos , Listas de Espera
5.
J Hepatol ; 78(6): 1181-1198, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37208105

RESUMO

With the increasing number of accepted candidates on waiting lists worldwide, there is an urgent need to expand the number and the quality of donor livers. Dynamic preservation approaches have demonstrated various benefits, including improving liver function and graft survival, and reducing liver injury and post-transplant complications. Consequently, organ perfusion techniques are being used in clinical practice in many countries. Despite this success, a proportion of livers do not meet current viability tests required for transplantation, even with the use of modern perfusion techniques. Therefore, devices are needed to further optimise machine liver perfusion - one promising option is to prolong machine liver perfusion for several days, with ex situ treatment of perfused livers. For example, stem cells, senolytics, or molecules targeting mitochondria or downstream signalling can be administered during long-term liver perfusion to modulate repair mechanisms and regeneration. Besides, today's perfusion equipment is also designed to enable the use of various liver bioengineering techniques, to develop scaffolds or for their re-cellularisation. Cells or entire livers can also undergo gene modulation to modify animal livers for xenotransplantation, to directly treat injured organs or to repopulate such scaffolds with "repaired" autologous cells. This review first discusses current strategies to improve the quality of donor livers, and secondly reports on bioengineering techniques to design optimised organs during machine perfusion. Current practice, as well as the benefits and challenges associated with these different perfusion strategies are discussed.


Assuntos
Transplante de Fígado , Animais , Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Fígado , Perfusão/métodos , Bioengenharia
6.
Ann Surg ; 277(5): 835-840, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36468404

RESUMO

OBJECTIVE: To report our experience with the combination of radical surgical excision and intestinal transplantation in patients with recurrent pseudomyxoma peritonei (PMP) not amenable to further cytoreductive surgery (CRS). BACKGROUND: CRS and heated intraoperative peritoneal chemotherapy are effective treatments for many patients with PMP. In patients with extensive small bowel involvement or nonresectable recurrence, disease progression results in small bowel obstruction, nutritional failure, and fistulation, with resulting abdominal wall failure. METHODS: Between 2013 and 2022, patients with PMP who had a nutritional failure and were not suitable for further CRS underwent radical debulking and intestinal transplantation at our centre. RESULTS: Fifteen patients underwent radical exenteration of affected intra-abdominal organs and transplantation adapted according to the individual case. Eight patients had isolated small bowel transplantation and 7 patients underwent modified multivisceral transplantation. In addition, in 7 patients with significant abdominal wall tumor involvement, a full-thickness vascularized abdominal wall transplant was performed. Two of the 15 patients died within 90 days due to surgically related complications. Actuarial 1-year and 5-year patient survivals were 79% and 55%, respectively. The majority of the patients had significant improvement in quality of life after transplantation. Progression/recurrence of disease was detected in 91% of patients followed up for more than 6 months. CONCLUSION: Intestinal/multivisceral transplantation enables a more radical approach to the management of PMP than can be achieved with conventional surgical methods and is suitable for patients for whom there is no conventional surgical option. This complex surgical intervention requires the combined skills of both peritoneal malignancy and transplant teams.


Assuntos
Hipertermia Induzida , Neoplasias Peritoneais , Pseudomixoma Peritoneal , Humanos , Pseudomixoma Peritoneal/cirurgia , Pseudomixoma Peritoneal/patologia , Seguimentos , Qualidade de Vida , Neoplasias Peritoneais/cirurgia , Peritônio/patologia , Procedimentos Cirúrgicos de Citorredução/métodos , Hipertermia Induzida/métodos , Estudos Retrospectivos , Terapia Combinada
7.
Ann Surg ; 278(5): e912-e921, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37389552

RESUMO

OBJECTIVE: To compare conventional low-temperature storage of transplant donor livers [static cold storage (SCS)] with storage of the organs at physiological body temperature [normothermic machine perfusion (NMP)]. BACKGROUND: The high success rate of liver transplantation is constrained by the shortage of transplantable organs (eg, waiting list mortality >20% in many centers). NMP maintains the liver in a functioning state to improve preservation quality and enable testing of the organ before transplantation. This is of greatest potential value with organs from brain-dead donor organs (DBD) with risk factors (age and comorbidities), and those from donors declared dead by cardiovascular criteria (donation after circulatory death). METHODS: Three hundred eighty-three donor organs were randomized by 15 US liver transplant centers to undergo NMP (n = 192) or SCS (n = 191). Two hundred sixty-six donor livers proceeded to transplantation (NMP: n = 136; SCS: n = 130). The primary endpoint of the study was "early allograft dysfunction" (EAD), a marker of early posttransplant liver injury and function. RESULTS: The difference in the incidence of EAD did not achieve significance, with 20.6% (NMP) versus 23.7% (SCS). Using exploratory, "as-treated" rather than "intent-to-treat," subgroup analyses, there was a greater effect size in donation after circulatory death donor livers (22.8% NMP vs 44.6% SCS) and in organs in the highest risk quartile by donor risk (19.2% NMP vs 33.3% SCS). The incidence of acute cardiovascular decompensation at organ reperfusion, "postreperfusion syndrome," as a secondary outcome was reduced in the NMP arm (5.9% vs 14.6%). CONCLUSIONS: NMP did not lower EAD, perhaps related to the inclusion of lower-risk liver donors, as higher-risk donor livers seemed to benefit more. The technology is safe in standard organ recovery and seems to have the greatest benefit for marginal donors.

8.
Transpl Int ; 36: 11645, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727383

RESUMO

Static Cold Storage (SCS) injures the bile duct, while the effect of Normothermic Machine Perfusion (NMP) is unknown. In a sub-study of the COPE trial on liver NMP, we investigated the impact of preservation type on histological bile duct injury score (BDIS). Transplants with at least one bile duct biopsy, either at end of preservation or 1 h post-reperfusion, were considered. BDIS was determined by assessing peribiliary glands injury, stromal and mural loss, haemorrhage, and thrombosis. A bivariate linear model compared BDIS (estimate, CI) between groups. Sixty-five transplants and 85 biopsies were analysed. Twenty-three grafts were preserved with SCS and 42 with NMP, with comparable baseline characteristics except for a shorter cold ischemic time in NMP. The BDIS increased over time regardless of preservation type (p = 0.04). The BDIS estimate was higher in NMP [8.02 (7.40-8.65)] than in SCS [5.39 (4.52-6.26), p < 0.0001] regardless of time. One patient in each group developed ischemic cholangiopathy, with a BDIS of 6 for the NMP-preserved liver. In six other NMP grafts, BDIS ranged 7-12 without development of ischemic cholangiopathy. In conclusion, BDIS increases over time, and the higher BDIS in NMP did not increase ischemic cholangiopathy. Thus, BDIS may overestimate this risk after liver NMP.


Assuntos
Ductos Biliares , Fígado , Humanos , Perfusão , Reperfusão , Biópsia
9.
Liver Transpl ; 28(11): 1716-1725, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35662403

RESUMO

In situ normothermic regional perfusion (NRP) and ex situ normothermic machine perfusion (NMP) aim to improve the outcomes of liver transplantation (LT) using controlled donation after circulatory death (cDCD). NRP and NMP have not yet been compared directly. In this international observational study, outcomes of LT performed between 2015 and 2019 for organs procured from cDCD donors subjected to NRP or NMP commenced at the donor center were compared using propensity score matching (PSM). Of the 224 cDCD donations in the NRP cohort that proceeded to asystole, 193 livers were procured, resulting in 157 transplants. In the NMP cohort, perfusion was commenced in all 40 cases and resulted in 34 transplants (use rates: 70% vs. 85% [p = 0.052], respectively). After PSM, 34 NMP liver recipients were matched with 68 NRP liver recipients. The two cohorts were similar for donor functional warm ischemia time (21 min after NRP vs. 20 min after NMP; p = 0.17), UK-Donation After Circulatory Death risk score (5 vs. 5 points; p = 0.38), and laboratory Model for End-Stage Liver Disease scores (12 vs. 12 points; p = 0.83). The incidence of nonanastomotic biliary strictures (1.5% vs. 2.9%; p > 0.99), early allograft dysfunction (20.6% vs. 8.8%; p = 0.13), and 30-day graft loss (4.4% vs. 8.8%; p = 0.40) were similar, although peak posttransplant aspartate aminotransferase levels were higher in the NRP cohort (872 vs. 344 IU/L; p < 0.001). NRP livers were more frequently allocated to recipients suffering from hepatocellular carcinoma (HCC; 60.3% vs. 20.6%; p < 0.001). HCC-censored 2-year graft and patient survival rates were 91.5% versus 88.2% (p = 0.52) and 97.9% versus 94.1% (p = 0.25) after NRP and NMP, respectively. Both perfusion techniques achieved similar outcomes and appeared to match benchmarks expected for donation after brain death livers. This study may inform the design of a definitive trial.


Assuntos
Carcinoma Hepatocelular , Doença Hepática Terminal , Neoplasias Hepáticas , Transplante de Fígado , Aspartato Aminotransferases , Doença Hepática Terminal/cirurgia , Sobrevivência de Enxerto , Humanos , Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Índice de Gravidade de Doença
10.
Clin Transplant ; 36(10): e14638, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35279883

RESUMO

BACKGROUND: Recent evidence supports the use of machine perfusion technologies (MP) for marginal liver grafts. Their effect on enhanced recovery, however, remains uncertain. OBJECTIVES: To identify areas in which MP might contribute to an ERAS program and to provide expert panel recommendations. DATA SOURCES: Ovid MEDLINE, Embase, Scopus, Google Scholar, and Cochrane Central. METHODS: Systematic review and meta-analysis following PRISMA guidelines and recommendations using the GRADE approach. CRD42021237713 RESULTS: Both hypothermic (HMP) and normothermic (NMP) machine perfusion demonstrated significant benefits in preventing postreperfusion syndrome (PRS) (HMP OR .33, .15-.75 CI; NMP OR .51, .29-.90 CI) and early allograft dysfunction (EAD) (HMP OR .51, .35-.75 CI; NMP OR .66, .45-.97 CI), while shortening LOS (HMP MD -3.9; NMP MD -12.41). Only NMP showed a significant decrease in the length of ICU stay (L-ICU) (MD -7.07, -8.76; -5.38 CI), while only HMP diminishes the likelihood of major complications. Normothermic regional perfusion (NRP) reduces EAD (OR .52, .38-.70 CI) and primary nonfunction (PNF) (OR .51, .27-.98 CI) without effect on L-ICU and LOS. CONCLUSIONS: The use of HMP decreases PRS and EAD, specifically for marginal grafts. This is supported by a shorter LOS and a lower rate of major postoperative complications (QOE; moderate | Recommendation; Strong). NMP reduces the incidence of PRS and EAD with associated shortening in L-ICU for both DBD and DCD grafts (QOE; moderate | Recommendation; High) This technology also shortens the length of hospital stay (QOE; low | Recommendation; Strong). NRP decreases the likelihood of EAD (QOE; moderate) and the risk of PNF (QOE; low) when compared to both DBD and SRR-DCD grafts preserved in SCS. (Recommendation; Strong).


Assuntos
Transplante de Fígado , Humanos , Preservação de Órgãos , Perfusão , Fígado , Sobrevivência de Enxerto
11.
Am J Transplant ; 21(11): 3673-3683, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33870619

RESUMO

There are concerns that simultaneous pancreas-kidney (SPK) transplants from donation after circulatory death (DCD) donors have a higher risk of graft failure than those from donation after brain death (DBD) donors. A UK registry analysis of SPK transplants between 2005 and 2018 was performed. Pancreas survivals of those receiving organs from DCD or DBD donors were compared. Multivariable analyses were used to adjust for baseline differences between the two groups and to identify factors associated with pancreas graft loss. A total of 2228 SPK transplants were implanted; 403 (18.1%) were from DCD donors. DCD donors were generally younger, slimmer, less likely to have stroke as a cause of death, with lower terminal creatinines and shorter pancreas cold ischemic times than DBD donors. Median (IQR) follow-up was 4.2 (1.6-8.1) years. On univariable analysis, there were no statistically significant differences in 5-year death-censored pancreas graft survival between the two donor types (79.5% versus 80.4%; p = .86). Multivariable analysis showed no statistically significant differences in 5-year pancreas graft loss between transplants from DCD (n = 343) and DBD (n = 1492) donors (hazard ratio 1.26, 95% CI 0.76-1.23; p = .12). The findings from this study support the increased use of SPK transplants from DCD donors.


Assuntos
Transplante de Rim , Obtenção de Tecidos e Órgãos , Morte Encefálica , Morte , Sobrevivência de Enxerto , Humanos , Pâncreas , Sistema de Registros , Estudos Retrospectivos , Doadores de Tecidos , Reino Unido
12.
Am J Transplant ; 21(5): 1740-1753, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33021021

RESUMO

We describe a proteomics analysis to determine the molecular differences between normothermically perfused (normothermic machine perfusion, NMP) human kidneys with urine recirculation (URC) and urine replacement (UR). Proteins were extracted from 16 kidney biopsies with URC (n = 8 donors after brain death [DBD], n = 8 donors after circulatory death [DCD]) and three with UR (n = 2 DBD, n = 1 DCD), followed by quantitative analysis by mass spectrometry. Damage-associated molecular patterns (DAMPs) were decreased in kidney tissue after 6 hours NMP with URC, suggesting reduced inflammation. Vasoconstriction was also attenuated in kidneys with URC as angiotensinogen levels were reduced. Strikingly, kidneys became metabolically active during NMP, which could be enhanced and prolonged by URC. For instance, mitochondrial succinate dehydrogenase enzyme levels as well as carbonic anhydrase were enhanced with URC, contributing to pH stabilization. Levels of cytosolic and the mitochondrial phosphoenolpyruvate carboxykinase were elevated after 24 hours of NMP, more prevalent in DCD than DBD tissue. Key enzymes involved in glucose metabolism were also increased after 12 and 24 hours of NMP with URC, including mitochondrial malate dehydrogenase and glutamic-oxaloacetic transaminase, predominantly in DCD tissue. We conclude that NMP with URC permits prolonged preservation and revitalizes metabolism to possibly better cope with ischemia reperfusion injury in discarded kidneys.


Assuntos
Preservação de Órgãos , Proteômica , Homeostase , Humanos , Rim , Perfusão
13.
Am J Transplant ; 21(3): 1012-1026, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33225626

RESUMO

The complement system plays a pivotal role in the pathogenesis of ischemia-reperfusion injury in solid organ transplantation. Mirococept is a potent membrane-localizing complement inhibitor that can be administered ex vivo to the donor kidney prior to transplantation. To evaluate the efficacy of Mirococept in reducing delayed graft function (DGF) in deceased donor renal transplantation, we undertook the efficacy of mirococept (APT070) for preventing ischaemia-reperfusion injury in the kidney allograft (EMPIRIKAL) trial (ISRCTN49958194). A dose range of 5-25 mg would be tested, starting with 10 mg in cohort 1. No significant difference between Mirococept at 10 mg and control was detected; hence the study was stopped to enable a further dose saturation study in a porcine kidney model. The optimal dose of Mirococept in pig kidney was 80 mg. This dose did not induce any additional histological damage compared to controls or after a subsequent 3 hours of normothermic machine perfusion. The amount of unbound Mirococept postperfusion was found to be within the systemic dose range considered safe in the Phase I trial. The ex vivo administration of Mirococept is a safe and feasible approach to treat DGF in deceased donor kidney transplantation. The porcine kidney study identified an optimal dose of 80 mg (equivalent to 120 mg in human kidney) that provides a basis for further clinical development.


Assuntos
Transplante de Rim , Traumatismo por Reperfusão , Animais , Inativadores do Complemento , Função Retardada do Enxerto/tratamento farmacológico , Função Retardada do Enxerto/prevenção & controle , Sobrevivência de Enxerto , Humanos , Rim , Transplante de Rim/efeitos adversos , Traumatismo por Reperfusão/tratamento farmacológico , Traumatismo por Reperfusão/prevenção & controle , Suínos , Doadores de Tecidos
14.
Am J Transplant ; 21(4): 1603-1611, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33171020

RESUMO

Short-term outcomes in kidney transplantation are marred by progressive transplant failure and mortality secondary to immunosuppression toxicity. Immune modulation with autologous polyclonal regulatory T cell (Treg) therapy may facilitate immunosuppression reduction promoting better long-term clinical outcomes. In a Phase I clinical trial, 12 kidney transplant recipients received 1-10 × 106 Treg per kg at Day +5 posttransplantation in lieu of induction immunosuppression (Treg Therapy cohort). Nineteen patients received standard immunosuppression (Reference cohort). Primary outcomes were rejection-free and patient survival. Patient and transplant survival was 100%; acute rejection-free survival was 100% in the Treg Therapy versus 78.9% in the reference cohort at 48 months posttransplant. Treg therapy revealed no excess safety concerns. Four patients in the Treg Therapy cohort had mycophenolate mofetil withdrawn successfully and remain on tacrolimus monotherapy. Treg infusion resulted in a long-lasting dose-dependent increase in peripheral blood Tregs together with an increase in marginal zone B cell numbers. We identified a pretransplantation immune phenotype suggesting a high risk of unsuccessful ex-vivo Treg expansion. Autologous Treg therapy is feasible, safe, and is potentially associated with a lower rejection rate than standard immunosuppression. Treg therapy may provide an exciting opportunity to minimize immunosuppression therapy and improve long-term outcomes.


Assuntos
Transplante de Rim , Estudos de Viabilidade , Rejeição de Enxerto/etiologia , Rejeição de Enxerto/prevenção & controle , Humanos , Imunossupressores/uso terapêutico , Doadores Vivos , Monitorização Imunológica , Linfócitos T Reguladores
15.
Am J Transplant ; 21 Suppl 3: 17-59, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34245223

RESUMO

The First World Consensus Conference on Pancreas Transplantation provided 49 jury deliberations regarding the impact of pancreas transplantation on the treatment of diabetic patients, and 110 experts' recommendations for the practice of pancreas transplantation. The main message from this consensus conference is that both simultaneous pancreas-kidney transplantation (SPK) and pancreas transplantation alone can improve long-term patient survival, and all types of pancreas transplantation dramatically improve the quality of life of recipients. Pancreas transplantation may also improve the course of chronic complications of diabetes, depending on their severity. Therefore, the advantages of pancreas transplantation appear to clearly surpass potential disadvantages. Pancreas after kidney transplantation increases the risk of mortality only in the early period after transplantation, but is associated with improved life expectancy thereafter. Additionally, preemptive SPK, when compared to SPK performed in patients undergoing dialysis, appears to be associated with improved outcomes. Time on dialysis has negative prognostic implications in SPK recipients. Increased long-term survival, improvement in the course of diabetic complications, and amelioration of quality of life justify preferential allocation of kidney grafts to SPK recipients. Audience discussions and live voting are available online at the following URL address: http://mediaeventi.unipi.it/category/1st-world-consensus-conference-of-pancreas-transplantation/246.


Assuntos
Diabetes Mellitus Tipo 1 , Transplante de Rim , Transplante de Pâncreas , Sobrevivência de Enxerto , Humanos , Qualidade de Vida , Diálise Renal
16.
J Hepatol ; 74(4): 881-892, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32976864

RESUMO

BACKGROUND & AIMS: Early allograft dysfunction (EAD) following liver transplantation (LT) negatively impacts graft and patient outcomes. Previously we reported that the liver graft assessment following transplantation (L-GrAFT7) risk score was superior to binary EAD or the model for early allograft function (MEAF) score for estimating 3-month graft failure-free survival in a single-center derivation cohort. Herein, we sought to externally validate L-GrAFT7, and compare its prognostic performance to EAD and MEAF. METHODS: Accuracies of L-GrAFT7, EAD, and MEAF were compared in a 3-center US validation cohort (n = 3,201), and a Consortium for Organ Preservation in Europe (COPE) normothermic machine perfusion (NMP) trial cohort (n = 222); characteristics were compared to assess generalizability. RESULTS: Compared to the derivation cohort, patients in the validation and NMP trial cohort had lower recipient median MELD scores; were less likely to require pretransplant hospitalization, renal replacement therapy or mechanical ventilation; and had superior 1-year overall (90% and 95% vs. 84%) and graft failure-free (88% and 93% vs. 81%) survival, with a lower incidence of 3-month graft failure (7.4% and 4.0% vs. 11.1%; p <0.001 for all comparisons). Despite significant differences in cohort characteristics, L-GrAFT7 maintained an excellent validation AUROC of 0.78, significantly superior to binary EAD (AUROC 0.68, p = 0.001) and MEAF scores (AUROC 0.72, p <0.001). In post hoc analysis of the COPE NMP trial, the highest tertile of L-GrAFT7 was significantly associated with time to liver allograft (hazard ratio [HR] 2.17, p = 0.016), Clavien ≥IIIB (HR 2.60, p = 0.034) and ≥IVa (HR 4.99, p = 0.011) complications; post-LT length of hospitalization (p = 0.002); and renal replacement therapy (odds ratio 3.62, p = 0.016). CONCLUSIONS: We have validated the L-GrAFT7 risk score as a generalizable, highly accurate, individualized risk assessment of 3-month liver allograft failure that is superior to existing scores. L-GrAFT7 may standardize grading of early hepatic allograft function and serve as a clinical endpoint in translational studies (www.lgraft.com). LAY SUMMARY: Early allograft dysfunction negatively affects outcomes following liver transplantation. In independent multicenter US and European cohorts totaling 3,423 patients undergoing liver transplantation, the liver graft assessment following transplantation (L-GrAFT) risk score is validated as a superior measure of early allograft function that accurately discriminates 3-month graft failure-free survival and post-liver transplantation complications.


Assuntos
Transplante de Fígado , Disfunção Primária do Enxerto , Medição de Risco , Europa (Continente)/epidemiologia , Feminino , Sobrevivência de Enxerto , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Transplante de Fígado/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde/estatística & dados numéricos , Disfunção Primária do Enxerto/diagnóstico , Disfunção Primária do Enxerto/epidemiologia , Disfunção Primária do Enxerto/terapia , Prognóstico , Traumatismo por Reperfusão/diagnóstico , Traumatismo por Reperfusão/epidemiologia , Traumatismo por Reperfusão/terapia , Reprodutibilidade dos Testes , Medição de Risco/métodos , Medição de Risco/normas , Fatores de Risco , Análise de Sobrevida , Estados Unidos/epidemiologia
17.
Lancet ; 395(10237): 1627-1639, 2020 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-32446407

RESUMO

BACKGROUND: Use of cell-based medicinal products (CBMPs) represents a state-of-the-art approach for reducing general immunosuppression in organ transplantation. We tested multiple regulatory CBMPs in kidney transplant trials to establish the safety of regulatory CBMPs when combined with reduced immunosuppressive treatment. METHODS: The ONE Study consisted of seven investigator-led, single-arm trials done internationally at eight hospitals in France, Germany, Italy, the UK, and the USA (60 week follow-up). Included patients were living-donor kidney transplant recipients aged 18 years and older. The reference group trial (RGT) was a standard-of-care group given basiliximab, tapered steroids, mycophenolate mofetil, and tacrolimus. Six non-randomised phase 1/2A cell therapy group (CTG) trials were pooled and analysed, in which patients received one of six CBMPs containing regulatory T cells, dendritic cells, or macrophages; patient selection and immunosuppression mirrored the RGT, except basiliximab induction was substituted with CBMPs and mycophenolate mofetil tapering was allowed. None of the trials were randomised and none of the individuals involved were masked. The primary endpoint was biopsy-confirmed acute rejection (BCAR) within 60 weeks after transplantation; adverse event coding was centralised. The RTG and CTG trials are registered with ClinicalTrials.gov, NCT01656135, NCT02252055, NCT02085629, NCT02244801, NCT02371434, NCT02129881, and NCT02091232. FINDINGS: The seven trials took place between Dec 11, 2012, and Nov 14, 2018. Of 782 patients assessed for eligibility, 130 (17%) patients were enrolled and 104 were treated and included in the analysis. The 66 patients who were treated in the RGT were 73% male and had a median age of 47 years. The 38 patients who were treated across six CTG trials were 71% male and had a median age of 45 years. Standard-of-care immunosuppression in the recipients in the RGT resulted in a 12% BCAR rate (expected range 3·2-18·0). The overall BCAR rate for the six parallel CTG trials was 16%. 15 (40%) patients given CBMPs were successfully weaned from mycophenolate mofetil and maintained on tacrolimus monotherapy. Combined adverse event data and BCAR episodes from all six CTG trials revealed no safety concerns when compared with the RGT. Fewer episodes of infections were registered in CTG trials versus the RGT. INTERPRETATION: Regulatory cell therapy is achievable and safe in living-donor kidney transplant recipients, and is associated with fewer infectious complications, but similar rejection rates in the first year. Therefore, immune cell therapy is a potentially useful therapeutic approach in recipients of kidney transplant to minimise the burden of general immunosuppression. FUNDING: The 7th EU Framework Programme.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos/métodos , Rejeição de Enxerto/prevenção & controle , Terapia de Imunossupressão/métodos , Imunossupressores/uso terapêutico , Transplante de Rim , Terapia Baseada em Transplante de Células e Tecidos/efeitos adversos , Células Dendríticas/imunologia , Rejeição de Enxerto/imunologia , Humanos , Terapia de Imunossupressão/efeitos adversos , Macrófagos/imunologia , Linfócitos T Reguladores/imunologia
18.
Magn Reson Med ; 86(6): 3246-3258, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34272767

RESUMO

PURPOSE: A shortage of suitable donor livers is driving increased use of higher risk livers for transplantation. However, current biomarkers are not sensitive and specific enough to predict posttransplant liver function. This is limiting the expansion of the donor pool. Therefore, better noninvasive tests are required to determine which livers will function following implantation and hence can be safely transplanted. This study assesses the temperature sensitivity of proton density fat fraction and relaxometry parameters and examines their potential for assessment of liver function ex vivo. METHODS: Six ex vivo human livers were scanned during static cold storage following normothermic machine perfusion. Proton density fat fraction, T1 , T2 , and T2∗ were measured repeatedly during cooling on ice. Temperature corrections were derived from these measurements for the parameters that showed significant variation with temperature. RESULTS: Strong linear temperature sensitivities were observed for proton density fat fraction (R2 = 0.61, P < .001) and T1 (R2 = 0.78, P < .001). Temperature correction according to a linear model reduced the coefficient of repeatability in these measurements by 41% and 36%, respectively. No temperature dependence was observed in T2 or T2∗ measurements. Comparing livers deemed functional and nonfunctional during normothermic machine perfusion by hemodynamic and biochemical criteria, T1 differed significantly: 516 ± 50 ms for functional versus 679 ± 60 ms for nonfunctional, P = .02. CONCLUSION: Temperature correction is essential for robust measurement of proton density fat fraction and T1 in cold-stored human livers. These parameters may provide a noninvasive measure of viability for transplantation.


Assuntos
Fígado Gorduroso , Transplante de Fígado , Fígado Gorduroso/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Perfusão
19.
Transpl Int ; 34(7): 1306-1318, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33794037

RESUMO

Utilization of pancreases for transplantation remains inferior to that of other organs. Herein, we analysed UK pancreas discards to identify the reasons for the low utilization rates. Data on all pancreases offered first for solid organ transplantation between 1st January 2005 and 31st December 2015 were extracted from the UK Transplant Registry. The number of organs discarded, reasons and the time point of discard were analysed. A centre specific comparison was also undertaken. 7367 pancreases were offered first for solid organ transplantation. 35% were donors after circulatory death (DCD). 3668 (49.7%) organs were not retrieved. Of the 3699 pancreases retrieved, 38% were initially accepted but subsequently discarded. 2145 (29%) grafts offered were transplanted as simultaneous pancreas-kidney or solitary pancreas. 1177 (55%) were transplanted on the first offer whilst the remaining 968 were transplanted after a median of three offers. 52% DBD pancreases were accepted and transplanted on the first offer compared with 68% DCD grafts. There were significant differences in discard rates between centres (30-80% for DBD and 3-78% for DCD, P < 0.001). A significant number of solid pancreases are discarded. Better graft assessment at retrieval could minimize unnecessary organ travel and discards. Closer links with islet programmes may allow for better utilization of discarded grafts.


Assuntos
Transplante de Órgãos , Transplante de Pâncreas , Obtenção de Tecidos e Órgãos , Sobrevivência de Enxerto , Humanos , Pâncreas/cirurgia , Doadores de Tecidos , Reino Unido
20.
Transpl Int ; 34(9): 1630-1642, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34448276

RESUMO

Static cold storage (SCS) is the standard method for pancreas preservation prior to transplantation; however, it does not permit organ assessment. Normothermic reperfusion (NR) is utilized clinically for other organs to assess viability. Our aim was to develop NR using normothermic machine perfusion technique to simulate reperfusion at the time of transplantation, enabling evaluation of oxygenated hypothermic machine perfusion (HMPO2) as a newer strategy to optimize pancreas preservation. 13 porcine pancreases procured after circulatory death were divided into 3 groups: 4 pancreases preserved using SCS, and 2 groups preserved by HMPO2 (n = 4 and n = 5, differing by type of preservation solution). Duration of perfusion or cold storage was 6 hours before the 1-hour assessment using NR. Outcome measures were perfusion characteristics, biochemistry and change in tissue water mass as oedema assessment. During NR, the HMPO2 groups demonstrated better perfusion characteristics, normal macroscopic appearances, decreased water mass and one HMPO2 group demonstrated a response to glucose stimulation. Conversely, the SCS group showed an increased water mass and developed early macroscopic appearances of oedema, interstitial haemorrhage and minimal portal outflow. This study suggests that ex situ assessment of pancreases by NR is promising, and that HMPO2 may be better than SCS.


Assuntos
Preservação de Órgãos , Pancrelipase , Animais , Pâncreas/cirurgia , Perfusão , Reperfusão , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA