Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 301
Filtrar
1.
Eur Heart J ; 45(20): 1783-1800, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38606889

RESUMO

Clinical risk scores based on traditional risk factors of atherosclerosis correlate imprecisely to an individual's complex pathophysiological predisposition to atherosclerosis and provide limited accuracy for predicting major adverse cardiovascular events (MACE). Over the past two decades, computed tomography scanners and techniques for coronary computed tomography angiography (CCTA) analysis have substantially improved, enabling more precise atherosclerotic plaque quantification and characterization. The accuracy of CCTA for quantifying stenosis and atherosclerosis has been validated in numerous multicentre studies and has shown consistent incremental prognostic value for MACE over the clinical risk spectrum in different populations. Serial CCTA studies have advanced our understanding of vascular biology and atherosclerotic disease progression. The direct disease visualization of CCTA has the potential to be used synergistically with indirect markers of risk to significantly improve prevention of MACE, pending large-scale randomized evaluation.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Humanos , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Medição de Risco/métodos , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Fatores de Risco de Doenças Cardíacas , Prognóstico , Estenose Coronária/diagnóstico por imagem
2.
Eur Radiol ; 34(7): 4261-4272, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38114847

RESUMO

OBJECTIVES: To compare cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) for the quantitative assessment of the left ventricular (LV) trabeculated layer in patients with suspected noncompaction cardiomyopathy (NCCM). MATERIALS AND METHODS: Subjects with LV excessive trabeculation who underwent both CMR and CCT imaging as part of the prospective international multicenter NONCOMPACT clinical study were included. For each subject, short-axis CCT and CMR slices were matched. Four quantitative metrics were estimated: 1D noncompacted-to-compacted ratio (NCC), trabecular-to-myocardial area ratio (TMA), trabecular-to-endocardial cavity area ratio (TCA), and trabecular-to-myocardial volume ratio (TMV). In 20 subjects, end-diastolic and mid-diastolic CCT images were compared for the quantification of the trabeculated layer. Relationships between the metrics were investigated using linear regression models and Bland-Altman analyses. RESULTS: Forty-eight subjects (49.9 ± 12.8 years; 28 female) were included in this study. NCC was moderately correlated (r = 0.62), TMA and TMV were strongly correlated (r = 0.78 and 0.78), and TCA had excellent correlation (r = 0.92) between CMR and CCT, with an underestimation bias from CCT of 0.3 units, and 5.1, 4.8, and 5.4 percent-points for the 4 metrics, respectively. TMA, TCA, and TMV had excellent correlations (r = 0.93, 0.96, 0.94) and low biases (- 3.8, 0.8, - 3.8 percent-points) between the end-diastolic and mid-diastolic CCT images. CONCLUSIONS: TMA, TCA, and TMV metrics of the LV trabeculated layer in patients with suspected NCCM demonstrated high concordance between CCT and CMR images. TMA and TCA were highly reproducible and demonstrated minimal differences between mid-diastolic and end-diastolic CCT images. CLINICAL RELEVANCE STATEMENT: The results indicate similarity of CCT to CMR for quantifying the LV trabeculated layer, and the small differences in quantification between end-diastole and mid-diastole demonstrate the potential for quantifying the LV trabeculated layer from clinically performed coronary CT angiograms. KEY POINTS: • Data on cardiac CT for quantifying the left ventricular trabeculated layer are limited. • Cardiac CT yielded highly reproducible metrics of the left ventricular trabeculated layer that correlated well with metrics defined by cardiac MR. • Cardiac CT appears to be equivalent to cardiac MR for the quantification of the left ventricular trabeculated layer.


Assuntos
Ventrículos do Coração , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Adulto
3.
Radiology ; 309(2): e231149, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37962501

RESUMO

Background CT is helpful in guiding the revascularization of chronic total occlusion (CTO), but manual prediction scores of percutaneous coronary intervention (PCI) success have challenges. Deep learning (DL) is expected to predict success of PCI for CTO lesions more efficiently. Purpose To develop a DL model to predict guidewire crossing and PCI outcomes for CTO using coronary CT angiography (CCTA) and evaluate its performance compared with manual prediction scores. MATERIALS AND METHODS: Participants with CTO lesions were prospectively identified from one tertiary hospital between January 2018 and December 2021 as the training set to develop the DL prediction model for PCI of CTO, with fivefold cross validation. The algorithm was tested using an external test set prospectively enrolled from three tertiary hospitals between January 2021 and June 2022 with the same eligibility criteria. All participants underwent preprocedural CCTA within 1 month before PCI. The end points were guidewire crossing within 30 minutes and PCI success of CTO.Results A total of 534 participants (mean age, 57.7 years ± 10.8 [SD]; 417 [78.1%] men) with 565 CTO lesions were included. In the external test set (186 participants with 189 CTOs), the DL model saved 85.0% of the reconstruction and analysis time of manual scores (mean, 73.7 seconds vs 418.2-466.9 seconds) and had higher accuracy than manual scores in predicting guidewire crossing within 30 minutes (DL, 91.0%; CT Registry of Chronic Total Occlusion Revascularization, 61.9%; Korean Multicenter CTO CT Registry [KCCT], 68.3%; CCTA-derived Multicenter CTO Registry of Japan (J-CTO), 68.8%; P < .05) and PCI success (DL, 93.7%; KCCT, 74.6%; J-CTO, 75.1%; P < .05). For DL, the area under the receiver operating characteristic curve was 0.97 (95% CI: 0.89, 0.99) for the training test set and 0.96 (95% CI: 0.90, 0.98) for the external test set. Conclusion The DL prediction model accurately predicted the percutaneous recanalization outcomes of CTO lesions and increased the efficiency of noninvasively grading the difficulty of PCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Pundziute-do Prado in this issue.


Assuntos
Aprendizado Profundo , Intervenção Coronária Percutânea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Tomografia Computadorizada por Raios X , Idoso , Estudos Multicêntricos como Assunto
4.
Radiology ; 308(3): e230524, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37698477

RESUMO

Background The prognostic value of coronary CT angiography (CTA)-derived fractional flow reserve (FFR) beyond 1-year outcomes and in patients with high levels of coronary artery calcium (CAC) is uncertain. Purpose To assess the prognostic value of coronary CTA-derived FFR test results on 3-year clinical outcomes in patients with coronary stenosis and among a subgroup of patients with high levels of CAC. Materials and Methods This study represents a 3-year follow-up of patients with new-onset stable angina pectoris who were consecutively enrolled in the Assessing Diagnostic Value of Noninvasive CT-FFR in Coronary Care, known as ADVANCE (ClinicalTrials.gov: NCT02499679) registry, between December 2015 and October 2017 at three Danish sites. A high CAC was defined as an Agatston score of at least 400. A lesion-specific coronary CTA-derived FFR value of 2 cm with distal-to-stenosis value at or below 0.80 represented an abnormal test result. The primary end point was a composite of all-cause death and nonfatal spontaneous myocardial infarction. Event rates were estimated using the one-sample binomial model, and relative risk was compared between participants stratified by results of coronary CTA-derived FFR. Results This study included 900 participants: 523 participants with normal results (mean age, 64 years ± 9.6 [SD]; 318 male participants) and 377 with abnormal results from coronary CTA-derived FFR (mean age, 65 years ± 9.6; 264 male participants). The primary end point occurred in 11 of 523 (2.1%) and 25 of 377 (6.6%) participants with normal and abnormal coronary CTA-derived FFR results, respectively (relative risk, 3.1; 95% CI: 1.6, 6.3; P < .001). In participants with high CAC, the primary end point occurred in four of 182 (2.2%) and 19 of 212 (9.0%) participants with normal and abnormal coronary CTA-derived FFR results, respectively (relative risk, 4.1; 95% CI: 1.4, 11.8; P = .001). Conclusion In individuals with stable angina, a normal coronary CTA-derived FFR test result identified participants with a low 3-year risk of all-cause death or nonfatal spontaneous myocardial infarction, both in the overall cohort and in participants with high CAC scores. Clinical trial registration no. NCT02499679 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Sinitsyn in this issue.


Assuntos
Angina Estável , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Angina Estável/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Prognóstico , Angiografia Coronária , Tomografia Computadorizada por Raios X , Cálcio
5.
Eur Radiol ; 32(6): 4225-4233, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34989838

RESUMO

In this prospective, pilot study, we tested a kV-independent coronary artery calcium scoring CT protocol, using a novel reconstruction kernel (Sa36f). From December 2018 to November 2019, we performed an additional research scan in 61 patients undergoing clinical calcium scanning. For the standard protocol (120 kVp), images were reconstructed with a standard, medium-sharp kernel (Qr36d). For the research protocol (automated kVp selection), images were reconstructed with a novel kernel (Sa36f). Research scans were sequentially performed using a higher (cohort A, n = 31) and a lower (cohort B, n = 30) dose optimizer setting within the automatic system with customizable kV selection. Agatston scores, coronary calcium volumes, and radiation exposure of the standard and research protocol were compared. A phantom study was conducted to determine inter-scan variability. There was excellent correlation for the Agatston score between the two protocols (r = 0.99); however, the standard protocol resulted in slightly higher Agatston scores (29.4 [0-139.0] vs 17.4 [0-158.2], p = 0.028). The median calcium volumes were similar (11.5 [0-109.2] vs 11.2 [0-118.0] mm3; p = 0.176), and the number of calcified lesions was not significantly different (p = 0.092). One patient was reclassified to another risk category. The research protocol could be performed at a lower kV and resulted in a substantially lower radiation exposure, with a median volumetric CT dose index of 4.1 vs 5.2 mGy, respectively (p < 0.001). Our results showed that a consistent coronary calcium scoring can be achieved using a kV-independent protocol that lowers radiation doses compared to the standard protocol. KEY POINTS: • The Sa36f kernel enables kV-independent Agatston scoring without changing the original Agatston weighting threshold. • Agatston scores and calcium volumes of the standard and research protocols showed an excellent correlation. • The research protocol resulted in a significant reduction in radiation exposure with a mean reduction of 22% in DLP and 25% in CTDIvol.


Assuntos
Cálcio , Doença da Artéria Coronariana , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Projetos Piloto , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
6.
Eur Radiol ; 32(3): 1843-1852, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34523009

RESUMO

OBJECTIVES: Invasively measured fractional flow reserve (FFR) is associated with outcome in heart transplant (HTx) patients. Coronary computed tomography angiography (CCTA)-derived FFR (FFRct) provides additional functional information from anatomical CT images. We describe the first use of FFRct in HTx patients. METHODS: HTx patients underwent CCTA with FFRct to screen for cardiac allograft vasculopathy. FFRct was measured distal to each coronary stenosis > 30% and FFRct ≤ 0.8 indicated hemodynamically significant stenosis. FFRct was also measured at the most distal location of each vessel. Overall distal FFRct was calculated as the mean of the distal values in the left, right, and circumflex coronary artery in each patient. RESULTS: Seventy-three patients (age 56 (42-65) years, 63% males) at 11 (8-16) years after HTx were included. Eighteen (25%) patients had a focal hemodynamically significant stenosis (stenosis > 30% with FFRct ≤ 0.8). In the 55 patients without a hemodynamically significant focal FFRct stenosis (FFRct > 0.80), the distal left anterior descending artery FFRct was < 0.90 in 74% of the patients and 10 (18%) patients had ≥ 1 coronary artery with a distal FFRct ≤ 0.8, including 1 with a distal FFRct ≤ 0.8 in all coronaries. Overall distal FFRct in patients without focal stenosis was 0.88 (0.86-0.91), 0.87 (0.86-0.90), and 0.88 (0.86-0.91) (median with 25th-75th percentile) at 5-9, 10-14, or ≥ 15 years post-transplantation, respectively (p = 0.93). CONCLUSIONS: FFRct performed on CCTA scans of HTx patients demonstrated that 25% of patients had a focal coronary stenosis with FFRct ≤ 0.8. Even without a focal stenosis, FFRct values are often abnormal in HTx patients. KEY POINTS: • This is the first report describing the use of FFRct in in heart transplant patients. • FFRct identifies patients after heart transplantation with hemodynamically significant coronary stenosis. • Even without a focal stenosis, FFRct values are often abnormal in heart transplant patients.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Transplante de Coração , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
7.
Heart Vessels ; 37(3): 400-410, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34608510

RESUMO

Improvement of non-invasive identification of high-risk plaque may increase the preventive options of acute coronary syndrome. To describe the characteristics of thin-cap fibroatheroma (TCFA) in a post mortem model in comparison to characteristics of culprit lesions in patients with non-ST-elevation-myocardial-infarction (NSTEMI) using the dual energy computed tomography (DECT). Three post mortem hearts were prepared with iodine-contrast, inserted in a Kyoto phantom and scanned by DECT. Six TCFA were identified using histopathological analysis (cap thickness < 65 µm and necrotic core > 10% of the plaque area). In the NSTEMI group, 29 patients were scheduled to DECT prior to coronary angiography and invasive treatment. Culprit lesions were identified blinded for the patient history by two independent invasive cardiologists using the coronary angiography. The DECT analysis of TCFA and culprit lesions was performed retrospectively with determination of effective atomic number (Effective-Z), Hounsfield Unit (HU), plaque type (non-calcified, predominantly non-calcified, predominantly calcified or calcified), spotty calcification,, plaque length, plaque volume and plaque burden and the remodeling index. The Effective-Z, HU and plaqueburden were significantly different between TCFA and culprit lesions (P < 0.05).The TCFA plaques were more calcified in comparison to culprit lesions (P < 0.05). No significant difference in the other plaque characteristics was observed. The use of DECT demonstrated different Effective-Z values and different characteristics of post mortem TCFA in comparison to in vivo culprit lesions. This finding may highlight, that not all TCFA should be considered as vulnerable.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio sem Supradesnível do Segmento ST , Placa Aterosclerótica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Placa Aterosclerótica/diagnóstico , Placa Aterosclerótica/patologia , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Tomografia Computadorizada por Raios X/métodos
8.
Transpl Int ; 34(10): 1886-1894, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34268796

RESUMO

Cardiac allograft vasculopathy (CAV) is an accelerated form of coronary artery disease that affects long-term outcomes in heart transplant (HTx) patients. We prospectively evaluated the feasibility of coronary computed tomography angiography (CCTA) for the detection of CAV during clinical implementation at our center. All consecutive HTx patients >4 years post-transplant were actively converted from myocardial perfusion imaging to CCTA for the annual assessment of CAV. Between February 2018 and May 2019, 129/172 (75%) HTx patients underwent a CCTA. Renal impairment (n = 21/43) was the most frequent reason for patients could not undergo CCTA. CCTA image quality was good-excellent in 118/129 (92%) patients, and the radiation dose was 2.1 (1.6-2.8) mSv. CCTA showed obstructive CAV in 19/129 (15%) patients. Thirteen (10%) patients underwent additional tests, of which 8 patients underwent coronary revascularization within 90 days of CCTA. After 1 year, 3 additional coronary angiograms were performed, resulting in one revascularization in a patient with known severe CAV who developed ventricular tachycardia. One myocardial infarction after coronary stenting and 2 non-cardiac deaths were observed. CCTA can be successfully implemented for routine detection of CAV with good image quality and low radiation dose. CCTA allows CAV evaluation with the limited need for additional invasive testing.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Aloenxertos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Humanos
9.
Cardiology ; 146(6): 713-719, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34148041

RESUMO

OBJECTIVES: The aim of this study was to characterize the safety and efficiency of a strategy employing the limit of detection (LoD) of high-sensitivity troponin T (hs-TnT) as a gatekeeper for coronary computed tomography angiography (CCTA) in suspected acute coronary syndrome (ACS) patients in the emergency department (ED). METHODS: We included suspected ACS patients who underwent CCTA and were evaluated with hs-TnT. Patients were categorized as below the LoD and at or above the LoD. The primary outcome was 30-day major adverse cardiac events (MACEs), defined as all-cause mortality, ACS, or coronary revascularization. RESULTS: The study population consisted of 177 patients (mean age 55 ± 10 years, 50.3% women), and 16 (9.0%) patients reached the primary outcome. None of the patients died, while 13 had an adjudicated diagnosis of ACS, and 3 underwent elective coronary revascularization. There were 77 patients (44%) with an hs-TnT value below the LoD (MACEs; n = 1 [1.3%]) and 100 (56%) with at or above the LoD levels (MACEs; n = 15 [15%]). None of 67 patients with an hs-TnT value below the LoD and <50% stenosis on CCTA experienced MACEs. Out of the 10 patients with an hs-TnT value below the LoD and ≥50% stenosis on CCTA, 1 patient underwent elective percutaneous coronary revascularization. In patients with an hs-TnT value at or above the LoD, 74 patients had <50% stenosis on CCTA, and 2 patients (3%) were diagnosed with myocardial infarction without obstructive coronary artery disease confirmed on invasive angiography. Thirteen (50%) patients with an hs-TnT value at or above the LoD and ≥50% stenosis on CCTA experienced MACEs (11 ACS and 2 elective percutaneous coronary revascularizations). CONCLUSION: Our findings support that implementing the LoD of hs-TnT as a gatekeeper may reduce the need for CCTA in suspected ACS patients in the ED.


Assuntos
Síndrome Coronariana Aguda , Troponina T , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Angiografia , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Troponina T/análise
10.
Eur Radiol ; 30(7): 3692-3701, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32166492

RESUMO

OBJECTIVE: To determine the potential impact of on-site CT-derived fractional flow reserve (CT-FFR) on the diagnostic efficiency and effectiveness of coronary CT angiography (CCTA) in patients with obstructive coronary artery disease (CAD) on CCTA. METHODS: This observational cohort study included patients with suspected CAD who had been randomized to cardiac CT in the CRESCENT I and II trials. On-site CT-FFR was blindly performed in all patients with at least one ≥ 50% stenosis on CCTA and no exclusion criteria for CT-FFR. We retrospectively assessed the effect of adding CT-FFR to the CT protocol in patients with a stenosis ≥ 50% on CCTA in terms of diagnostic effectiveness, i.e., the number of additional tests required to determine the final diagnosis, reclassification of the initial management strategy, and invasive coronary angiography (ICA) efficiency, i.e., ICA rate without ≥ 50% CAD. RESULTS: Fifty-three patients out of the 372 patients (14%) had at least one ≥ 50% stenosis on CCTA of whom 42/53 patients (79%) had no exclusion criteria for CT-FFR. CT-FFR showed a hemodynamically significant stenosis (≤ 0.80) in 27/53 patients (51%). The availability of CT-FFR would have reduced the number of patients requiring additional testing by 57%-points compared with CCTA alone (37/53 vs. 7/53, p < 0.001). The initial management strategy would have changed for 30 patients (57%, p < 0.001). Reserving ICA for patients with a CT-FFR ≤ 0.80 would have reduced the number of ICA following CCTA by 13%-points (p = 0.016). CONCLUSION: Implementation of on-site CT-FFR may change management and improve diagnostic efficiency and effectiveness in patients with obstructive CAD on CCTA. KEY POINTS: • The availability of on-site CT-FFR in the diagnostic evaluation of patients with obstructive CAD on CCTA would have significantly reduced the number of patients requiring additional testing compared with CCTA alone. • The implementation of on-site CT-FFR would have changed the initial management strategy significantly in the patients with obstructive CAD on CCTA. • Restricting ICA to patients with a positive CT-FFR would have significantly reduced the ICA rate in patients with obstructive CAD on CCTA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Aprendizado de Máquina , Idoso , Cateterismo Cardíaco , Estudos de Coortes , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Gerenciamento Clínico , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
Eur Heart J ; 40(24): 1975-1986, 2019 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-30060039

RESUMO

Artificial intelligence (AI) has transformed key aspects of human life. Machine learning (ML), which is a subset of AI wherein machines autonomously acquire information by extracting patterns from large databases, has been increasingly used within the medical community, and specifically within the domain of cardiovascular diseases. In this review, we present a brief overview of ML methodologies that are used for the construction of inferential and predictive data-driven models. We highlight several domains of ML application such as echocardiography, electrocardiography, and recently developed non-invasive imaging modalities such as coronary artery calcium scoring and coronary computed tomography angiography. We conclude by reviewing the limitations associated with contemporary application of ML algorithms within the cardiovascular disease field.


Assuntos
Técnicas de Imagem Cardíaca/instrumentação , Doenças Cardiovasculares/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Aprendizado de Máquina/normas , Algoritmos , Inteligência Artificial/normas , Cálcio/metabolismo , Angiografia por Tomografia Computadorizada/instrumentação , Vasos Coronários/diagnóstico por imagem , Ecocardiografia/instrumentação , Eletrocardiografia/instrumentação , Humanos , Redes Neurais de Computação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
12.
Radiology ; 292(3): 597-605, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31335283

RESUMO

Background Coronary artery fractional flow reserve (FFR) derived from CT angiography (FFTCT) enables functional assessment of coronary stenosis. Prior clinical trials showed 13%-33% of coronary CT angiography studies had insufficient quality for quantitative analysis with FFRCT. Purpose To determine the rejection rate of FFRCT analysis and to determine factors associated with technically unsuccessful calculation of FFRCT. Materials and Methods Prospectively acquired coronary CT angiography scans submitted as part of the Assessing Diagnostic Value of Noninvasive FFRCT in Coronary Care (ADVANCE) registry (https://ClinicalTrials.gov: NCT02499679) and coronary CT angiography series submitted for clinical analysis were included. The primary outcome was the FFRCT rejection rate (defined as an inability to perform quantitative analysis with FFRCT). Factors that were associated with FFRCT rejection rate were assessed with multiple linear regression. Results In the ADVANCE registry, FFRCT rejection rate due to inadequate image quality was 2.9% (80 of 2778 patients; 95% confidence interval [CI]: 2.1%, 3.2%). In the 10 621 consecutive patients who underwent clinical analysis, the FFRCT rejection rate was 8.4% (n = 892; 95% CI: 6.2%, 7.2%; P < .001 vs the ADVANCE cohort). The main reason for the inability to perform FFRCT analysis was the presence of motion artifacts (63 of 80 [78%] and 729 of 892 [64%] in the ADVANCE and clinical cohorts, respectively). At multivariable analysis, section thickness in the ADVANCE (odds ratio [OR], 1.04; 95% CI: 1.001, 1.09; P = .045) and clinical (OR, 1.03; 95% CI: 1.02, 1.04; P < .001) cohorts and heart rate in the ADVANCE (OR, 1.05; 95% CI: 1.02, 1.08; P < .001) and clinical (OR, 1.06; 95% CI: 1.05, 1.07; P < .001) cohorts were independent predictors of rejection. Conclusion The rates for technically unsuccessful CT-derived fractional flow reserve in the ADVANCE registry and in a large clinical cohort were 2.9% and 8.4%, respectively. Thinner CT section thickness and lower patient heart rate may increase rates of completion of CT fractional flow reserve analysis. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Sakuma in this issue.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
13.
Eur Radiol ; 29(11): 6109-6118, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31016447

RESUMO

OBJECTIVE: To compare the effect of contrast medium iodine concentration on contrast enhancement, heart rate, and injection pressure when injected at a constant iodine delivery rate in coronary CT angiography (CTA). METHODS: One thousand twenty-four patients scheduled for coronary CTA were prospectively randomized to receive one of four contrast media: iopromide 300 mg I/ml, iohexol 350 mg I/ml, iopromide 370 mg I/ml, or iomeprol 400 mg I/ml. Contrast media were delivered at an equivalent iodine delivery rate of 2.0 g I/s. Intracoronary attenuation was measured and compared (per vessel and per segment). Heart rate before and after contrast media injection was documented. Injection pressure was recorded (n = 403) during contrast medium injection and compared between groups. RESULTS: Intracoronary attenuation values were similar for the different contrast groups. The mean attenuation over all segments ranged between 384 HU for 350 mg I/ml and 395 HU for 400 mg I/ml (p = 0.079). Dose-length product (p = 0.8424), signal-to-noise ratio (all p > 0.05), time to peak (p = 0.324), and changes in heart rate (p = 0.974) were comparable between groups. The peak pressures differed: 197.4 psi for 300 mg I/ml (viscosity 4.6 mPa s), 229.8 psi for 350 mg I/ml (10.4 mPa s), 216.1 psi for 370 mg I/ml (9.5 mPa s), and 243.7 psi for 400 mg I/ml (12.6 mPa s) (p < 0.0001). CONCLUSION: Intravascular attenuation and changes in heart rate are independent of iodine concentration when contrast media are injected at the same iodine delivery rate. Differences in injection pressures are associated with the viscosity of the contrast media. KEY POINTS: • The contrast enhancement in coronary CT angiography is independent of the iodine concentration when contrast media are injected at body temperature (37 °C) with the same iodine delivery rate. • Iodine concentration does not influence the change in heart rate when contrast media are injected at identical iodine delivery rates. • For a fixed iodine delivery rate and contrast temperature, the viscosity of the contrast medium affects the injection pressure.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/farmacocinética , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Iodo/metabolismo , Iohexol/farmacocinética , Meios de Contraste/administração & dosagem , Doença da Artéria Coronariana/metabolismo , Feminino , Humanos , Injeções Intravenosas , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Iopamidol/administração & dosagem , Iopamidol/análogos & derivados , Iopamidol/farmacocinética , Masculino , Pessoa de Meia-Idade
14.
Clin Transplant ; 33(10): e13699, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31437316

RESUMO

Heart transplant (HTx) recipients are at increased risk of pericardial disease. Idiopathic recurrent pericarditis has not been previously described following HTx. We describe a 35-year-old male who was admitted with pericarditis and moderate pericardial effusion 10 months after HTx. Two weeks before his admission, his prednisone had been tapered off. A thorough infectious workup and endomyocardial biopsy was unrevealing. He was started on colchicine with the addition of tapering prednisone regimen of 40 mg daily due to unresolved pain. Over the next several years, he had three recurrent episodes of pericarditis requiring re-initiation of prednisone with extensive investigations negative for rejection, autoimmune, and infectious causes. Cardiac MRI confirmed pericardial inflammation. Due to his recurrent course and inability to wean off prednisone, anakinra, an IL-1 receptor antagonist, was started at 100 mg sc daily. This allowed successful discontinuation of prednisone. He is now 34 months post-transplant without recurrence on anakinra and colchicine maintenance. Due to the overlap between idiopathic recurrent pericarditis and auto-inflammatory diseases, there is growing evidence for utilizing IL-1 receptor antagonists in this condition. While pericarditis is common in the HTx population, this is the first report of successful use of an IL-1 receptor blocker for pericarditis in this population.


Assuntos
Antirreumáticos/uso terapêutico , Cardiomiopatias/cirurgia , Transplante de Coração/efeitos adversos , Proteína Antagonista do Receptor de Interleucina 1/uso terapêutico , Pericardite/tratamento farmacológico , Receptores de Interleucina-1/antagonistas & inibidores , Adulto , Cardiomiopatias/patologia , Humanos , Masculino , Pericardite/etiologia , Pericardite/patologia , Prognóstico
15.
AJR Am J Roentgenol ; 213(2): 325-331, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31039021

RESUMO

OBJECTIVE. Coronary CT angiography (CCTA)-based methods allow noninvasive estimation of fractional flow reserve (cFFR), recently through use of a machine learning (ML) algorithm (cFFRML). However, attenuation values vary according to the tube voltage used, and it has not been shown whether this significantly affects the diagnostic performance of cFFR and cFFRML. Therefore, the purpose of this study is to retrospectively evaluate the effect of tube voltage on the diagnostic performance of cFFRML. MATERIALS AND METHODS. A total of 525 coronary vessels in 351 patients identified in the MACHINE consortium registry were evaluated in terms of invasively measured FFR and cFFRML. CCTA examinations were performed with a tube voltage of 80, 100, or 120 kVp. For each tube voltage value, correlation (assessed by Spearman rank correlation coefficient), agreement (evaluated by intraclass correlation coefficient and Bland-Altman plot analysis), and diagnostic performance (based on ROC AUC value, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy) of the cFFRML in terms of detection of significant stenosis were calculated. RESULTS. For tube voltages of 80, 100, and 120 kVp, the Spearman correlation coefficient for cFFRML in relation to the invasively measured FFR value was ρ = 0.684, ρ = 0.622, and ρ = 0.669, respectively (p < 0.001 for all). The corresponding intraclass correlation coefficient was 0.78, 0.76, and 0.77, respectively (p < 0.001 for all). Sensitivity was 100.0%, 73.5%, and 85.0%, and specificity was 76.2%, 79.0%, and 72.8% for tube voltages of 80, 100, and 120 kVp, respectively. The ROC AUC value was 0.90, 0.82, and 0.80 for 80, 100, and 120 kVp, respectively (p < 0.001 for all). CONCLUSION. CCTA-derived cFFRML is a robust method, and its performance does not vary significantly between examinations performed using tube voltages of 100 kVp and 120 kVp. However, because of rapid advancements in CT and postprocessing technology, further research is needed.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Aprendizado de Máquina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sistema de Registros , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
Circ J ; 83(6): 1293-1301, 2019 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-30996150

RESUMO

BACKGROUND: Coronary computed tomography angiography (cCTA)-derived fractional flow reserve (FFRCT) is a promising diagnostic method for the evaluation of coronary artery disease (CAD). However, clinical data regarding FFRCTin Japan are scarce, so we assessed the clinical impact of using FFRCTin a Japanese population.Methods and Results:The ADVANCE registry is an international prospective FFRCTregistry of patients suspected of CAD. Of 5,083 patients, 1,829 subjects enrolled from Japan were analyzed. Demographics, symptoms, cCTA, FFRCT, treatment strategy, and 90-day major cardiovascular events (MACE) were assessed. Reclassification of treatment strategy between cCTA alone and cCTA+FFRCToccurred in 55.8% of site investigations and in 56.9% in the core laboratory analysis. Patients with positive FFR (FFRCT≤0.80) were less likely to have non-obstructive disease on invasive coronary angiography than patients with negative FFR (FFRCT>0.80) (20.5% vs. 46.1%, P=0.0001). After FFRCT, 67.0% of patients with positive results underwent revascularization, whereas 96.1% of patients with negative FFRCTwere medically treated. MACE occurred in 5 patients with positive FFRCT, but none occurred in patients with negative FFRCTwithin 90 days. CONCLUSIONS: In this Japanese population, FFRCTmodified the treatment strategy in more than half of the patients. FFRCTshowed potential for stratifying patients suspected of CAD properly into invasive or non-invasive management pathways.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Humanos , Japão , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros
17.
MAGMA ; 32(2): 269-279, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30171383

RESUMO

PURPOSE: With the hypothesis that 4D flow can be used in evaluation of cardiac shunts, we seek to evaluate the multilevel and interreader reproducibility of measurements of the blood flow, shunt fraction and shunt volume in patients with atrial septum defect (ASD) in practice at multiple clinical sites. MATERIALS AND METHODS: Four-dimensional flow MRI examinations were performed at four institutions across Europe and the US. Twenty-nine patients (mean age, 43 years; 11 male) were included in the study. Flow measurements were performed at three levels (valve, main artery and periphery) in both the pulmonary and systemic circulation by two independent readers and compared against stroke volumes from 4D flow anatomic data. Further, the shunt ratio (Qp/Qs) was calculated. Additionally, shunt volume was quantified at the atrial level by tracking the atrial septum. RESULTS: Measurements of the pulmonary blood flow at multiple levels correlate well whether measuring at the valve, main pulmonary artery or branch pulmonary arteries (r = 0.885-0.886). Measurements of the systemic blood flow show excellent correlation, whether measuring at the valve, ascending aorta or sum of flow from the superior vena cava (SVC) and descending aorta (r = 0.974-0.991). Intraclass agreement between the two observers for the flow measurements varies between 0.96 and 0.99. Compared with stroke volume, pulmonic flow is underestimated with 0.26 l/min at the main pulmonary artery level, and systemic flow is overestimated with 0.16 l/min at the ascending aorta level. Direct measurements of ASD flow are feasible in 20 of 29 (69%) patients. CONCLUSION: Blood flow and shunt quantification measured at multiple levels and performed by different readers are reproducible and consistent with 4D flow MRI.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem Cardíaca/estatística & dados numéricos , Feminino , Comunicação Interatrial/classificação , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/estatística & dados numéricos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Circulação Pulmonar , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico
18.
Eur Heart J ; 39(41): 3739-3749, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29351615

RESUMO

The timely diagnosis of prosthetic heart valve endocarditis remains challenging yet of utmost importance. 18F-fluorodeoxyglucose (18 F-FDG) positron emission/computed tomography (PET/CT) and cardiac computed tomography angiography (CTA) were recently introduced as additional diagnostic tools in the most recent ESC guidelines on infective endocarditis. However, how to interpret PET/CT findings with regard to what is to be considered abnormal, what the potential confounders may be, as well as which patients benefit most from these additional imaging techniques and how to best perform them in these often-complex patients, remains unclear. This review focusses on factors regarding patient selection and image acquisition that need to be taken into account when employing 18F-FDG PET/CT and CTA in daily clinical practice, and the importance of a multidisciplinary Endocarditis Team herein. Furthermore, it emphasizes the need for standardized acquisition protocols and image interpretation, especially now that these techniques are starting to be widely embraced by the cardiovascular society.


Assuntos
Técnicas de Imagem Cardíaca , Endocardite Bacteriana/diagnóstico por imagem , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Fluordesoxiglucose F18/administração & dosagem , Fluordesoxiglucose F18/uso terapêutico , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Guias de Prática Clínica como Assunto
19.
Eur Heart J ; 39(41): 3701-3711, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30165613

RESUMO

Aims: Non-invasive assessment of stable chest pain patients is a critical determinant of resource utilization and clinical outcomes. Increasingly coronary computed tomography angiography (CCTA) with selective CCTA-derived fractional flow reserve (FFRCT) is being used. The ADVANCE Registry, is a large prospective examination of using a CCTA and FFRCT diagnostic pathway in real-world settings, with the aim of determining the impact of this pathway on decision-making, downstream invasive coronary angiography (ICA), revascularization, and major adverse cardiovascular events (MACE). Methods and results: A total of 5083 patients with symptoms concerning for coronary artery disease (CAD) and atherosclerosis on CCTA were enrolled at 38 international sites from 15 July 2015 to 20 October 2017. Demographics, symptom status, CCTA and FFRCT findings, treatment plans, and 90 days outcomes were recorded. The primary endpoint of reclassification between core lab CCTA alone and CCTA plus FFRCT-based management plans occurred in 66.9% [confidence interval (CI): 64.8-67.6] of patients. Non-obstructive coronary disease was significantly lower in ICA patients with FFRCT ≤0.80 (14.4%) compared to patients with FFRCT >0.80 (43.8%, odds ratio 0.19, CI: 0.15-0.25, P < 0.001). In total, 72.3% of subjects undergoing ICA with FFRCT ≤0.80 were revascularized. No death/myocardial infarction (MI) occurred within 90 days in patients with FFRCT >0.80 (n = 1529), whereas 19 (0.6%) MACE [hazard ratio (HR) 19.75, CI: 1.19-326, P = 0.0008] and 14 (0.3%) death/MI (HR 14.68, CI 0.88-246, P = 0.039) occurred in subjects with an FFRCT ≤0.80. Conclusions: In a large international multicentre population, FFRCT modified treatment recommendation in two-thirds of subjects as compared to CCTA alone, was associated with less negative ICA, predicted revascularization, and identified subjects at low risk of adverse events through 90 days.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Revascularização Miocárdica/estatística & dados numéricos , Estudos Prospectivos , Fatores de Risco
20.
Radiology ; 286(1): 71-80, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28809582

RESUMO

Purpose To show that equal coronary lumen opacification can be achieved with iso- and low-osmolar contrast media when it is injected at the same iodine delivery rate with contemporary cardiac computed tomographic (CT) protocols and to investigate the cardiovascular effect of iso-osmolar contrast media and the image quality achieved. Materials and Methods Institutional review board approval and written informed consent were obtained for the Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography, or IsoCOR, trial. Between November 2015 and August 2016, 306 patients (167 [55%] women) at least 18 years old (weight range, 50-125 kg), were prospectively randomized to receive iso-osmolar iodixanol 270 or low-osmolar iopromide 300 contrast media. All coronary segments were assessed for intraluminal opacification and image quality and were compared by using the Student t test. Heart rate, arrhythmia, patient discomfort, and adverse events also were monitored. Results Mean measured coronary attenuation values ± standard deviation were comparable between the iodixanol 270 and iopromide 300 contrast media groups (469 HU ± 167 vs 447 HU ± 166, respectively [P = .241]; 95% confidence interval: -15.1, 60.0), including those from subanalyses. Adjusted for the lower iodine concentration, the mean iodixanol 270 bolus was larger compared with that of iopromide 300 (76.8 mL ± 11.6 vs 69.7 mL ± 10.8, respectively; P < .001). The higher injection rate was associated with higher pressure (777 kPa ± 308 vs 630 kPa ± 252, respectively; P < .001). Although in the iodixanol 270 group patients experienced less heat discomfort (72% vs 86%, respectively; P < .001), no differences in heart rate or rhythm were observed. Conclusion If injected at comparable iodine delivery rates, the iso-osmolar contrast medium iodixanol 270 is not inferior to low-osmolar contrast medium iopromide 300 for assessment of coronary opacification. Iodixanol 270 was associated with less heat discomfort, but did not affect heart rate differently compared with iopromide 300. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste/uso terapêutico , Angiografia Coronária , Iohexol/análogos & derivados , Ácidos Tri-Iodobenzoicos/uso terapêutico , Adulto , Pressão Sanguínea/efeitos dos fármacos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Meios de Contraste/efeitos adversos , Angiografia Coronária/métodos , Angiografia Coronária/estatística & dados numéricos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Iohexol/efeitos adversos , Iohexol/uso terapêutico , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Ácidos Tri-Iodobenzoicos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA