Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(4): 1007-1012, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37852443

RESUMO

BACKGROUND: Although the modular sleeve concept for femoral implants has several advantages, studies reporting on greater than 20-year outcomes are limited. This study aimed to report the mean 23-year results of total hip arthroplasty (THA) using a modular stem with metaphyseal fixation sleeve. METHODS: This study reviewed primary THAs performed using a modular stem between October 1994 and April 1998. Of the 272 hips (221 patients) identified, 220 hips (177 patients) satisfying the minimum 20-year follow-up were included. The Harris Hip Score was used for clinical evaluation. Final hip radiographs were analyzed to evaluate the implant stability and the extent of femoral osteolysis. The mean follow-up duration was 23 years (range, 20 to 28). RESULTS: The mean Harris Hip Score improved from 38 points (range, 26 to 67) preoperatively to 90 points (range, 71 to 100) at the final follow-up (P < .001). Femoral osteolysis was observed in 146 hips (67.1%), but 145 were located proximal to the osseo-integrated sleeve. Overall, 4 femoral revisions were performed; 2 for chronic infection, one for aseptic loosening, and one for periprosthetic femoral fracture. Of the 19 (8.6%) periprosthetic femoral fractures, the most common type was Vancouver AG (13 hips). One (0.5%) asymptomatic distal stem fracture occurred, while no complications were identified at the stem-sleeve junction. Implant survivorship free of any femoral revision was 98.3% at 23 years. CONCLUSIONS: A THA using a modular stem with metaphyseal fixation sleeve demonstrated 98.3% stem survivorship with excellent clinical outcomes at a mean follow-up of 23 years in non-obese patients.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Osteólise , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Osteólise/etiologia , Osteólise/cirurgia , Seguimentos , Reoperação/efeitos adversos , Falha de Prótese , Desenho de Prótese , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/complicações , Fraturas do Fêmur/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
2.
J Arthroplasty ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38735552

RESUMO

BACKGROUND: We previously reported the mean 6-year outcomes of total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) articulations. With extended observations, this study aimed to report the mean 12-year outcomes focusing on bearing-related complications of CoC THA. METHODS: We reviewed primary CoC THAs performed between May 2009 and April 2012 at a single institution. Of the 831 hips (739 patients), 716 hips (635 patients) that satisfied a minimum 10-year follow-up were included. The mean age at operation was 54 years (range, 16 to 83). The occurrence of bearing-specific complications, including ceramic fractures and noise generation, was evaluated. The mean follow-up duration was 12 years (range, 10 to 14). RESULTS: A total of 2 (0.3%) ceramic liner fractures occurred, as previously reported. No additional ceramic fractures were observed during the extended follow-up period. However, the cumulative incidence of audible noise increased from 6.4 (48 of 749) to 8.2% (59 of 716). Of the 59 hips with noise, 26 (44.1%) developed noise within 1 year, whereas 13 (22.0%) presented with noise more than 5 years after THA. The noise was described as clicking in 35 hips (4.9%) and as squeaking in 24 hips (3.4%). No revision surgeries were performed for noise, except in 2 cases of concomitant liner fractures. The implant survivorship free of any revision was 98.1% at 12 years. CONCLUSIONS: No additional ceramic fractures were identified in this extension study at a minimum follow-up of 10 years. However, the prevalence of articular noise has increased from 6.4 to 8.2% since the previous report. Possible late-onset noise should be considered when performing CoC THA in younger patients.

3.
J Arthroplasty ; 38(7): 1335-1341, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36709880

RESUMO

BACKGROUND: Cementing a new liner into a secure, well-positioned metallic shell can be a less-invasive strategy in revision total hip arthroplasty (THA). This study aimed to report the mean 14-year outcomes of cementing highly cross-linked polyethylene (XLPE) liners into well-fixed acetabular shells in revision THAs. METHODS: This study reviewed a single-surgeon series of cementing XLPE liners into well-fixed acetabular components. Of the 52 hips (51 patients) evaluated, 48 hips (47 patients) that satisfied a minimum follow-up of 10 years were included. The Harris Hip score was used for clinical evaluation. Final hip radiographs were used to determine the extent of acetabular osteolysis and stability of the components. The mean age at index operation was 53 years (range, 32 to 72). The mean follow-up duration was 14 years (range, 10 to 18). RESULTS: The mean Harris Hip score improved from 58 points (range, 23-81) preoperatively to 91 points (range, 45-100) at the final evaluation (P < .001). A total of 3 acetabular rerevisions were performed, all for aseptic loosening of the outer shell. One postoperative dislocation occurred, but it was successfully treated with a closed reduction. Final radiographs showed a significant reduction in acetabular osteolysis (P < .001). Implant survivorship free from any rerevision was 93.3% (95% confidence interval, 85.9-100%) at 14 years. CONCLUSION: Cementing an XLPE liner into a well-fixed acetabular shell in revision THA demonstrated excellent clinical and radiographic outcomes at a mean of 14 years postoperatively. This technique could be a safe and durable option in the absence of XLPE liners compatible with preimplanted shells.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Artroplastia de Quadril/métodos , Polietileno , Osteólise/etiologia , Osteólise/cirurgia , Falha de Prótese , Acetábulo/cirurgia , Reoperação , Desenho de Prótese , Seguimentos
4.
J Arthroplasty ; 38(8): 1621-1627, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36720417

RESUMO

BACKGROUND: Iliopsoas tendinopathy (IPT) can cause persistent groin pain and lead to dissatisfaction after total hip arthroplasty (THA). This study aimed to report the characteristics, incidences, risk factors, and treatment outcomes of IPT after THA. METHODS: We reviewed primary THAs performed at a single institution between January 2012 and May 2018. Clinical and radiographic analyses were performed on 1,602 THAs (1,370 patients). Patient characteristics, component sizes, inclination and anteversion angles, and antero-inferior cup prominence (≥8 millimeters (mm)), were compared between the groups with and without IPT. Changes in teardrop to lesser trochanter distance were measured to estimate changes in leg length and horizontal offset caused by THA. Logistic regression models were used to identify the risk factors for IPT. IPT was identified in 53 hips (3.3%). RESULTS: Patients with IPT had greater leg lengthening (12.3 versus 9.3 mm; P = .001) and higher prevalence of antero-inferior cup prominence (5.7 versus 0.4%; P = .002). There was no significant difference in inclination, anteversion, and horizontal offset change between the two groups. In multivariate analyses, greater leg lengthening, prominent acetabular cup, women, and higher body mass index were associated with IPT. All patients reported improvement in groin pain after arthroscopic tenotomy, while 35.7% with nonoperative management reported improvement (P < .001). CONCLUSIONS: Symptomatic IPT occurred in 53 (3.3%) of the 1,602 primary THAs. Our findings suggest that leg lengthening as well as prominent acetabular cup in THAs can be associated with the development of IPT. Arthroscopic tenotomy was effective in relieving groin pain caused by IPT.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Tendinopatia , Humanos , Feminino , Artroplastia de Quadril/efeitos adversos , Incidência , Acetábulo/cirurgia , Tendinopatia/diagnóstico por imagem , Tendinopatia/epidemiologia , Tendinopatia/etiologia , Fatores de Risco , Dor/cirurgia , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos
5.
J Arthroplasty ; 38(11): 2379-2385, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37271230

RESUMO

BACKGROUND: Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. METHODS: A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12 to 139). Overall, 45 (1.4%) postoperative PFFs occurred. RESULTS: The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 versus 0.7 versus 0.7%; P = .022). Additionally, more surgical treatments (1.7 versus 0.5 versus 0.7%; P = .013) and femoral revisions (1.2 versus 0.2 versus 0%; P = .004) were required for PFF in type B1 stems. After controlling for confounding variables, older age, diagnosis of hip fracture, and use of type B1 stems were significant factors associated with PFF. CONCLUSION: Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients who have compromised bone quality.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Idoso , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Fraturas do Fêmur/epidemiologia , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Fêmur/cirurgia , Reoperação/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Fatores de Risco
6.
J Arthroplasty ; 37(12): 2420-2426, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35753649

RESUMO

BACKGROUND: Tapered modular stems are increasingly used in revision total hip arthroplasty (THA) with deficient femoral bone stock. This study aimed to report the long-term outcomes of revision THA using a tapered and fluted modular stem. METHODS: Between December 1998 and February 2006, 113 revision THAs (110 patients) were performed with a tapered and fluted modular stem at a single institution. Hip radiographs were used to identify stem subsidence, stability, and femoral radiolucency. Final outcomes were assessed in 72 hips (70 patients), with a minimum follow-up of 10 years. RESULTS: The mean follow-up duration was 16 years (range, 10-23). At the final evaluation, the Harris Hip Score improved from a mean of 41 points (range, 10-72) preoperatively to 83 points (range, 56-100) (P < .001). Six femoral re-revisions were performed for the following reasons: 1 aseptic loosening, 2 stem fractures, and 3 infections. One stem fracture occurred at the modular junction after 14 years, and the other at a more distal location after 15 years. Stem subsidence was >5 mm in 6 hips (9.1%), but secondary stability was achieved in all stems. Osseointegration was observed in 63 (95.5%) hips. Stem survivorship was 91.1% with an end point of any re-revision and 94.6% for aseptic re-revision. CONCLUSION: A tapered and fluted modular stem demonstrated excellent implant survivorship with reliable bony fixation at a mean follow-up of 16 years. This type of stem can be a durable option for revision THA in patients who have femoral defects.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Desenho de Prótese , Seguimentos , Reoperação , Fêmur/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Falha de Prótese
7.
Int Orthop ; 46(4): 789-795, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35064307

RESUMO

BACKGROUND: Recurrent dislocation is a difficult complication after total hip arthroplasty (THA). This study aimed to report the clinical and radiographic outcomes of revision THA using the modular dual mobility (MDM) acetabular system to treat recurrent dislocation. METHODS: Between March 2015 and February 2019, 34 revision THAs were performed using the MDM system for treating recurrent dislocation in a single institution. Of these, 32 revision THAs (32 patients) that satisfied a minimum follow-up of one year (mean, 4 years) were included in this study. Patient-reported outcomes, complication rates, and radiographic results were evaluated. RESULTS: Seventeen patients (53.1%) had lumbar degenerative kyphosis, and six (18.8%) had surgically fused lumbar spines during the index operation. All acetabular components were revised, whereas femoral stems were retained in 29 patients (90.6%). No redislocation or intraprosthetic dislocation was noted after revision. One additional revision was required for acetabular loosening with periprosthetic joint infection. No additional revision was performed for aseptic loosening. A partial radiolucent line was found in two hips (6.3%) confined to one acetabular zone. CONCLUSIONS: Revision THA using the MDM system was effective in treating recurrent dislocation in a group of patients with a high prevalence of lumbar spinal pathology. During a mean follow-up of 4 years, one additional revision THA was performed for septic loosening and none for aseptic loosening.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Luxações Articulares , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Seguimentos , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Luxações Articulares/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Estudos Retrospectivos
8.
J Arthroplasty ; 35(10): 3002-3009, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32553792

RESUMO

BACKGROUND: Intraoperative femoral fractures are well-known but often overlooked complications in total hip arthroplasty (THA). We examined outcomes of cerclage cabling for intraoperative calcar cracks in THA with cementless tapered wedge stems. METHODS: In total, 4928 primary THAs were performed using broach-only, tapered wedge stems between January 2007 and November 2017 in a single institution. Of these, we identified 71 intraoperative calcar cracks (69 patients) managed by 2-mm cerclage cables. Clinical outcomes, amount of stem subsidence, and implant survivorship of the calcar crack group (68 THAs) were compared with those of the matched control group (68 THAs) without intraoperative fractures. Multivariate analysis was performed to identify potential risk factors for stem subsidence >3 mm. RESULTS: The mean stem subsidence was greater in the calcar crack group (2.0 vs 1.2 mm, P = .021), whereas revision-free survivorships of THA were similar between groups at 6 years (98.5% vs 98.4%; log-rank, P = .987). In the calcar crack group, a Dorr type C femur and the absence of cabling proximal to the lesser trochanter (LT) were identified as independent risk factors for stem subsidence >3 mm. For the subgroup with 42 calcar cracks managed by a single cable applied proximal to the LT, revision-free survivorship of THA was 100% at 6 years. There was no complete radiolucency to indicate aseptic stem loosening in either group. CONCLUSION: The application of a single cable proximal to the LT of the femur for intraoperative calcar cracks demonstrated 100% revision-free survivorship with lower stem subsidence in THA with tapered wedge stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Reoperação , Estudos Retrospectivos
9.
J Arthroplasty ; 35(1): 204-211, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31521447

RESUMO

BACKGROUND: Total hip arthroplasty (THA) with subtrochanteric shortening osteotomy (SSO) is performed to manage hips with high dislocations. We compared outcomes of THA with SSO in patients with high hip dislocation resulting from childhood septic arthritis and Crowe IV developmental dysplasia of the hip (DDH). METHODS: We reviewed 60 THAs with SSO performed between May 1996 and December 2013. Thirty-one cases were classified as sequelae of childhood infection and 29 as DDH. Twenty-five hips were selected for each group after the propensity score was matched with preoperative demographics and leg length discrepancy (LLD). Clinical scores, complication and reoperation rates, radiographic results, and survivorships were compared. The mean duration of follow-up was 12.3 (range 5-22) years. RESULTS: The average correction in LLD was 2.5 cm for childhood infection and 3.6 cm for DDH (P = .002). The infection group received more transfusions (mean 3.3 vs 2.0 units, P = .002), required more time for union of osteotomy site (mean 6.8 vs 5.2 months, P = .042), and reported lower Harris Hip Score (mean 85.1 vs 91.3, P = .017). Reoperations were performed in 11 (44%) previously infected hips and 3 (12%) DDHs (P = .012). Kaplan-Meier survivorship with an endpoint of revision for any reason was lower in the infection group (83.6%) than in the DDH group (100%) at 10 years (log rank, P = .040). CONCLUSION: THA with SSO in high hip dislocation secondary to childhood septic arthritis demonstrated less favorable clinical outcomes with increased risks of complication, compared with those performed in Crowe IV DDH with similar degree of chronic dislocation.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Luxação Congênita de Quadril , Luxação do Quadril , Artrite Infecciosa/epidemiologia , Artrite Infecciosa/etiologia , Artrite Infecciosa/cirurgia , Artroplastia de Quadril/efeitos adversos , Criança , Fêmur/cirurgia , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Luxação Congênita de Quadril/complicações , Luxação Congênita de Quadril/cirurgia , Humanos , Osteotomia , Estudos Retrospectivos
10.
J Arthroplasty ; 34(7): 1387-1394, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30930158

RESUMO

BACKGROUND: We previously reported unexpected early failures of total hip arthroplasty (THA) utilizing a 28-mm Ultima metal-on-metal (MoM) articulation. However, long-term results of small-diameter MoM THAs still remain unclear. The purpose of this study was to evaluate the clinical and radiographic outcomes of the previously reported cohort at a minimum follow-up of 15 years. METHODS: The original cohort consisted of 171 primary THAs (167 patients) using a 28-mm MoM articulation performed between April 2000 and March 2002. Of these, 130 hips (126 patients) were reviewed at an average follow-up of 17.1 (range, 15-18) years. Clinical score, complications, presence of osteolytic lesion, serum metal ion concentrations, and implant survivorships were evaluated. RESULTS: The mean Harris Hip Score improved from 44.9 points preoperatively to 90.5 points at the latest follow-up. During the entire period since the original surgery, a total of 5 revisions (3.8%) were associated with adverse reaction to metal debris (ARMD). The last revision surgery for symptomatic ARMD was performed at 6 years postoperatively. The implant survivorships with an end point of revision for aseptic failure and for any reason were 95.4% and 93.8%, respectively. Radiographic osteolytic lesions were detected in 27 hips (20.8%). The average serum metal concentration was 2.50 (range, 0.12-9.86) µg/L for cobalt and 2.81 (range, 0.82-12.3) µg/L for chromium. CONCLUSIONS: THA using a 28-mm MoM articulation showed favorable long-term outcomes with a relatively high revision-free survival rate. There was no significant symptomatic ARMD after the last acetabular revision performed at 6 years postoperatively.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Próteses Articulares Metal-Metal/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cromo/sangue , Cobalto/sangue , Feminino , Seguimentos , Quadril/cirurgia , Articulação do Quadril/cirurgia , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Desenho de Prótese , Resultado do Tratamento , Adulto Jovem
11.
J Arthroplasty ; 34(3): 527-533, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30545654

RESUMO

BACKGROUND: There is a lack of understanding on relationship between the femoral geometry and outcomes of total hip arthroplasty (THA). We investigated clinical and radiographic outcomes of THA using a cementless tapered wedge stem in patients with Dorr type A proximal femoral morphology and compared with those of type B femurs at a minimum follow-up of 5 years. METHODS: We analyzed 1089 hips (876 patients) that underwent THA using an identical cementless tapered wedge stem. We divided all femurs into 3 types (Dorr type A, B, and C). Type A and B femurs were statistically matched with age, gender, body mass index, and diagnosis by using propensity score matching. Clinical, radiographic results, and stem survivorship were compared between the matched 2 groups. RESULTS: A total of 611 femurs (56%) were classified as type A, 427 (39%) as type B, and 51 (5%) as type C. More radiolucent lines around femoral stems were found in type A femurs (7.8%) than in type B femurs (2.5%) (P < .001). Patients with radiolucency showed worse Harris Hip Score (86.2 points) compared with those without radiolucency (93.0 points) (P < .001). The stem survivorship of type A femur (97.8%) was lower than that of type B femur (99.5%) (P = .041). The reasons for femoral revision in type A femurs were periprosthetic fracture (67%), aseptic loosening (22%), and deep infection (11%). CONCLUSIONS: This study showed a higher rate of complications after THAs using a cementless tapered wedge stem in Dorr type A femurs than those performed in type B femurs.


Assuntos
Artroplastia de Quadril/instrumentação , Fêmur/cirurgia , Prótese de Quadril/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Feminino , Fêmur/anatomia & histologia , Fêmur/diagnóstico por imagem , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/cirurgia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Radiografia , Reoperação/estatística & dados numéricos , República da Coreia/epidemiologia , Adulto Jovem
12.
J Arthroplasty ; 33(7): 2182-2186.e1, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29599034

RESUMO

BACKGROUND: The purpose of this study is to evaluate the minimum 5-year outcomes and bearing-specific complications in a single surgeon series of fourth-generation alumina ceramic-on-ceramic total hip arthroplasties (THAs). METHODS: We retrospectively analyzed 667 patients (749 hips) who underwent primary THAs by a single surgeon using fourth-generation alumina ceramic bearings. There were 315 men and 352 women with a mean age of 54.2 years. The surgeon used cementless prostheses with an identical design and BIOLOX Delta ceramics in all hips, using a 36-mm head in 472 hips (63%) and a 32-mm head in 227. The mean follow-up duration was 6.5 years (range, 5 to 8 years). RESULTS: The mean Harris hip score improved from 45.6 points preoperatively to 91.3 points at final follow-up. All but 1 acetabular cup and all femoral stems were well fixed. No radiographic evidence of osteolysis was identified at final follow-up. There were 2 (0.3%) ceramic liner fractures and no ceramic head fractures. A total of 48 hips (6.4%) exhibited audible noise (29 clickings and 19 squeakings), but no patient required revision. Other complications were 1 dislocation, 1 deep infection, 3 iliopsoas tendonitis, and 6 periprosthetic femoral fractures. Kaplan-Meier survivorship for revision for any reason was 98.6% (95% confidence interval, 97.7-99.5) at 6.5 years. CONCLUSION: Delta ceramic-on-ceramic THAs had a high rate of survivorship without radiographic evidence of osteolysis at 6.5-year follow-up. However, we found 0.3% ceramic liner fractures and 6.4% audible noises associated with the use of Delta ceramics.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Acetábulo/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Cerâmica , Feminino , Fêmur/cirurgia , Necrose da Cabeça do Fêmur/cirurgia , Seguimentos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Osteólise/etiologia , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
13.
Clin Orthop Relat Res ; 473(12): 3781-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26024582

RESUMO

BACKGROUND: Modern ceramic-on-ceramic bearings have become attractive alternatives to conventional polyethylene in total hip arthroplasty (THA) as a result of their low wear and minimal particle production. However, 28-mm heads in ceramic-on-ceramic bearing couples have been associated with ceramic fracture. To address these issues, 32-mm and larger ceramic heads with a titanium-alloy sleeve have been introduced, although limited data are available on their durability and clinical outcomes. QUESTIONS/PURPOSES: We determined (1) the survivorship of the primary ceramic-on-ceramic THA using a 32-mm ceramic head with a titanium-alloy sleeve at a minimum followup of 5 years; (2) Harris hip scores; (3) the incidence of ceramic fracture and noisy hip; and (4) the proportion of hips showing radiographic evidence of osteolysis. METHODS: From November 2005 to August 2009, we performed 301 ceramic-on-ceramic THAs using a 32-mm ceramic head with a titanium-alloy sleeve in 270 patients. Of these, 12 patients (12 hips [4%]) died from problems unrelated to surgery and 13 patients (15 hips [5%]) were lost during followup before a minimum of 5 years had been reached, leaving 245 patients who had 274 THAs with a minimum followup of 5 years (mean, 6.5 years; range, 5-9 years) in this retrospective analysis. During the study period, 30% (301 of 997 hips) were performed with this articulation based on the operating surgeon's discretion. The mean patient age at the time of surgery was 55 years (range, 16-82 years). All operations were performed at a single center. All of the ceramic implants were hot isostatic-pressed, laser-marked, proof-tested third-generation alumina. We determined the implant survival, Harris hip scores, incidence of ceramic fracture or noisy hips (based on a questionnaire), and presence of osteolysis. RESULTS: The survival rate of ceramic-on-ceramic bearings in primary THA using a 32-mm ceramic head with a titanium-alloy sleeve was 98% (95% confidence interval, 96%-100%) at 9 years. The Harris hip score improved from a mean of 47 points preoperatively to 93 points at last followup. One ceramic head fractured at 6 years postoperatively. No ceramic liners fractured. Audible hip clicking and squeaking were identified in four hips and one hip, respectively. Osteolysis was detected in three hips, but none had symptoms. CONCLUSIONS: Primary ceramic-on-ceramic THA using a 32-mm ceramic head with a titanium-alloy sleeve has a survivorship of 98% at 9-year followup. Nevertheless, surgeons should be aware of the potential risks of ceramic fracture, noise, and osteolysis associated with the use of a ceramic head with a titanium-alloy sleeve. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Ligas Metalo-Cerâmicas , Titânio , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Intervalo Livre de Doença , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Ruído , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Osteólise/cirurgia , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , República da Coreia , Estudos Retrospectivos , Fatores de Risco , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
14.
BMC Musculoskelet Disord ; 16: 278, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26437678

RESUMO

BACKGROUND: Immune thrombocytopenia (ITP) is an immune-mediated acquired disease that is characterized by a decrease in the platelet count and an increased risk of bleeding. There is little information in the literature about the results of major joint replacement surgery in patients with ITP. The aim of this study was to report on the results of total hip arthroplasty (THA) in patients with primary ITP. METHODS: We retrospectively identified 15 THAs performed in 11 patients with primary ITP. The study group was matched (1:2) to a non-ITP control group of 30 THAs in 22 patients. According to the perioperative hematologic evaluation, blood management interventions were performed. All procedures were performed by a single surgeon and all patients received cementless components with ceramic-on-ceramic bearing. Mean duration of follow-up was 7.1 years (range, 2-13). RESULTS: No significant differences were found between the two groups with regard to mean operative time, intraoperative blood loss, amount of closed suction drainage, length of hospital stay, and readmission rate. However, the proportion of patients requiring transfusion of packed red blood cells and/or platelet concentrate was higher in the ITP group when compared to the non-ITP group. Mean Harris hip score improved from 49.5 points preoperatively to 93.4 points at the final follow-up and no hips were revised for loosening or osteolysis in the ITP group. No significant differences were found between the two groups with respect to mean postoperative Harris hip scores and complication rates. CONCLUSIONS: Our study showed encouraging clinical and radiographic results of THA in patients with ITP without increased risk of adverse events compared to those in patients without ITP. On the basis of these findings, we suggest that modern cementless THA might be a viable treatment for achieving functional improvement in patients with ITP and end-stage hip disease.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Púrpura Trombocitopênica Idiopática/complicações , Adulto , Idoso , Transfusão de Sangue/estatística & dados numéricos , Feminino , Necrose da Cabeça do Fêmur/complicações , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/complicações , Osteoartrite do Quadril/cirurgia , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
15.
Int Orthop ; 39(9): 1689-93, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25385003

RESUMO

PURPOSE: Periprosthetic femur fracture is a potentially worrisome phenomenon for cementless stem fixation. The aim of this study was to document the incidence of stem loosening following periprosthetic femur fracture in previously well-fixed cementless grit-blasted tapered-wedge stems. METHODS: We identified 36 periprosthetic femur fractures of either Vancouver B1 or B2 following hip arthroplasties using cementless grit-blasted tapered-wedge titanium stems at three participating institutions (GB group). The control group consisted of 21 periprosthetic femur fractures of either Vancouver B1 or B2 following hip arthroplasties using cementless proximal porous-coated stems at the same institutions during the same period of study (PC group). All femoral stems had been in a well-fixed state before occurrence of fracture. All patients were treated surgically and femoral stem stability was assessed using preoperative radiographs and confirmed by intraoperative scrutinization. RESULTS: Seven (19.4%) of 36 fractures were Vancouver B1 and 29 (80.6%) were Vancouver B2 in the GB group, whereas 18 (85.7%) of 21 fractures were Vancouver B1 and 3 (14.3%) were Vancouver B2 in the PC group (P < 0.0001). The odds ratio for stem loosening was 24.86 (95% CI, 5.69-108.63) in the GB group versus the PC group. CONCLUSIONS: Hip arthroplasty using cementless grit-blasted tapered-wedge titanium stems showed higher incidence of stem loosening in association with periprosthetic femur fracture than hip arthroplasty conducted using proximal porous-coated stems. A high index of suspicion of stem loosening might be necessary in periprosthetic femur fracture following hip arthroplasty using this type of stems.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fraturas do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/cirurgia , Adulto , Idoso , Materiais Biocompatíveis , Feminino , Fraturas do Fêmur/etiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/etiologia , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Titânio
16.
J Arthroplasty ; 29(3): 634-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24029718

RESUMO

The present study was undertaken to document outcomes of cementation of a highly cross-linked polyethylene (PE) liner into a well-fixed acetabular metal shell in 36 hips. All operations were performed by a single surgeon using only one type of liner. Patients were followed for a mean of 6.1 years (range, 3-8 years). Mean Harris hip score improved from 58 points preoperatively to 91 points postoperatively. There were no cases of PE liner dislodgement or progressive osteolysis. 1 hip (2.8%) required revision surgery for acetabular cup loosening with greater trochanteric fracture. Complications included 1 peroneal nerve palsy and 1 dislocation. The results of this study and previous reports demonstrated that cementation of highly cross-linked PE liner into well-fixed metal shell could provide good midterm durability.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Acetábulo/cirurgia , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Materiais Biocompatíveis , Cimentação , Feminino , Articulação do Quadril , Humanos , Artropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Polietileno , Desenho de Prótese , Reoperação , Resultado do Tratamento
17.
J Arthroplasty ; 29(12): 2383-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24674731

RESUMO

To evaluate the effects of micro-arc oxidation (MAO) coating on the outcomes of a grit-blasted tapered-wedge stem in total hip arthroplasty (THA), we performed a retrospective review of 141 THAs using MAO coated stem for a minimum of 5years and compared them to 219 THAs using the same geometry stem without MAO coating. Harris hip score improved from 43.7 points preoperatively to 93.9 points postoperatively. No hips were revised for aseptic loosening. Complications included one squeaking hip, one iliopsoas tendonitis, and one deep vein thrombosis. Postoperative Harris hip scores, WOMAC scores, UCLA activity scores, stem stabilities, and complication rates did not differ between the groups. After medium-term follow-up, our findings did not support the use of MAO coating on grit-blasted tapered-wedge stem to improve clinical outcomes.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril , Prótese de Quadril , Artropatias/cirurgia , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação , Materiais Revestidos Biocompatíveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
18.
J Bone Miner Metab ; 31(6): 637-43, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23579311

RESUMO

It is still uncertain whether total bilirubin per se is a risk factor for osteoporosis in postmenopausal women and no study has so far examined this important issue. This study was designed to assess the sheer effects of total bilirubin on the prevalence of osteoporosis in postmenopausal women without potential liver disease. In the present study, postmenopausal female subjects without potential liver disease (n = 918) who underwent measurement of bone mineral density were enrolled. Correlation and logistic regression analysis were used to assess the relationship between total bilirubin and other variables. As a result, subjects with osteoporosis had a significantly lower total bilirubin level (P = 0.005). A 0.1 mg/dl increase in total bilirubin was associated with reduced odds ratio of the risk by 38 % for osteoporosis [OR 0.62 (95 % CI 0.52-0.88), P = 0.012] after adjustment for several variables. Total bilirubin was independently associated with BMD [coefficient = 0.41, 95 % CI (0.35-0.47), P < 0.001 for lumbar spine and coefficient = 0.44, 95 % CI (0.36-0.48), P < 0.001 for femur neck]. A positive correlation could be observed with significant difference between total bilirubin and z-score (r = 0.33, P < 0.001 for lumbar spine and r = 0.37, P < 0.001 for femur neck) and total bilirubin was positively correlated with serum calcium (r = 0.13, P < 0.001) as well. Therefore, this study demonstrates an independent inverse association between total bilirubin and the prevalence of osteoporosis in postmenopausal women without potential liver disease. Total bilirubin would be useful as a provisional new risk factor of osteoporosis in such a population.


Assuntos
Bilirrubina/metabolismo , Vértebras Lombares/fisiopatologia , Osteoporose Pós-Menopausa/epidemiologia , Idoso , Densidade Óssea/fisiologia , Feminino , Colo do Fêmur/metabolismo , Humanos , Hepatopatias/metabolismo , Vértebras Lombares/metabolismo , Pessoa de Meia-Idade , Osteoporose Pós-Menopausa/metabolismo , Fatores de Risco
19.
J Arthroplasty ; 28(3): 504-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23116541

RESUMO

This study aimed to report the outcome of total hip arthroplasty (THA) with a modular femoral component in patients younger than fifty years with osteonecrosis of femoral head. Sixty-four osteonecrotic hips in fifty-five patients were available for clinical and radiographic analyses at minimum follow-up of fifteen-years. The mean Harris hip score improved from 36 points preoperatively to 92.7 points at final follow-up. Sixty-two (95.3%) hips demonstrated stable bone ingrowth. No hips showed loosening or required revision for aseptic loosening. Survivorship with an end point of stem revision for any reason was 93.8% and for aseptic loosening was 100% at 16.8years. We believe that cementless THA with a modular stem is a promising procedure for young and active patients with osteonecrosis of the femoral head.


Assuntos
Artroplastia de Quadril , Necrose da Cabeça do Fêmur/cirurgia , Prótese de Quadril , Adulto , Cimentos Ósseos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
20.
J Arthroplasty ; 27(1): 60-5, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21419593

RESUMO

Femoroacetabular cup impingement (FACI), defined as the presence of a bony spur or indentation at the femoral neck corresponding to the abutment site of metallic cup, was observed in 9 (11%) of the 84 hips with contemporary resurfacing arthroplasty of the hip. All FACIs occurred in men after a mean of 14 months (range, 8-24 months) postoperatively. Five patients had persistent groin pain if the hip was moved into flexion, abduction, and external rotation. One patient sustained a late-onset fracture through the femoral neck already weakened by postoperative change of osteonecrosis. Mean postoperative Harris hip score in the FACI group was poorer than that in the non-FACI group (P = .003). Multiple logistic regression analysis showed a significant association of FACI with a low acetabular cup inclination (odds ratio, 1.42; 95% confidence interval, 1.01-1.99; P = .046) and a high cup uncoverage ratio (odds ratio, 1.36; 95% confidence interval, 1.01-1.84; P = .045).


Assuntos
Artroplastia de Quadril/efeitos adversos , Impacto Femoroacetabular/etiologia , Prótese de Quadril , Adolescente , Adulto , Feminino , Impacto Femoroacetabular/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA