Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Molecules ; 29(7)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38611855

RESUMO

Quinoa, known as the "golden grain" for its high nutritional value, has polysaccharides as one of its sources of important nutrients. However, the biological functions of quinoa polysaccharides remain understudied. In this study, two crude polysaccharide extracts of quinoa (Q-40 and Q-60) were obtained through sequential precipitation with 40% and 60% ethanol, with purities of 58.29% (HPLC) and 62.15% (HPLC) and a protein content of 8.27% and 9.60%, respectively. Monosaccharide analysis revealed that Q-40 contained glucose (Glc), galacturonic acid (GalA), and arabinose (Ara) in a molar ratio of 0.967:0.027:0.006. Q-60 was composed of xylose (xyl), arabinose (Ara), galactose, and galacturonic acid (GalA) with a molar ratio of 0.889:0.036:0.034:0.020. The average molecular weight of Q-40 ranged from 47,484 to 626,488 Da, while Q-60 showed a range of 10,025 to 47,990 Da. Rheological experiments showed that Q-40 exhibited higher viscosity, while Q-60 demonstrated more elastic properties. Remarkably, Q-60 showed potent antioxidant abilities, with scavenging rates of 98.49% for DPPH and 57.5% for ABTS. Antibacterial experiments using the microdilution method revealed that Q-40 inhibited the growth of methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli (E. coli), while Q-60 specifically inhibited MRSA. At lower concentrations, both polysaccharides inhibited MDA (MD Anderson Cancer Center) cell proliferation, but at higher concentrations, they promoted proliferation. Similar proliferation-promoting effects were observed in HepG2 cells. The research provides important information in the application of quinoa in the food and functional food industries.


Assuntos
Chenopodium quinoa , Ácidos Hexurônicos , Staphylococcus aureus Resistente à Meticilina , Arabinose , Escherichia coli , Grão Comestível
2.
J Transl Med ; 21(1): 503, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37495991

RESUMO

Mitochondria play important roles in maintaining cellular homeostasis and skeletal muscle health, and damage to mitochondria can lead to a series of pathophysiological changes. Mitochondrial dysfunction can lead to skeletal muscle atrophy, and its molecular mechanism leading to skeletal muscle atrophy is complex. Understanding the pathogenesis of mitochondrial dysfunction is useful for the prevention and treatment of skeletal muscle atrophy, and finding drugs and methods to target and modulate mitochondrial function are urgent tasks in the prevention and treatment of skeletal muscle atrophy. In this review, we first discussed the roles of normal mitochondria in skeletal muscle. Importantly, we described the effect of mitochondrial dysfunction on skeletal muscle atrophy and the molecular mechanisms involved. Furthermore, the regulatory roles of different signaling pathways (AMPK-SIRT1-PGC-1α, IGF-1-PI3K-Akt-mTOR, FoxOs, JAK-STAT3, TGF-ß-Smad2/3 and NF-κB pathways, etc.) and the roles of mitochondrial factors were investigated in mitochondrial dysfunction. Next, we analyzed the manifestations of mitochondrial dysfunction in muscle atrophy caused by different diseases. Finally, we summarized the preventive and therapeutic effects of targeted regulation of mitochondrial function on skeletal muscle atrophy, including drug therapy, exercise and diet, gene therapy, stem cell therapy and physical therapy. This review is of great significance for the holistic understanding of the important role of mitochondria in skeletal muscle, which is helpful for researchers to further understanding the molecular regulatory mechanism of skeletal muscle atrophy, and has an important inspiring role for the development of therapeutic strategies for muscle atrophy targeting mitochondria in the future.


Assuntos
Atrofia Muscular , Fosfatidilinositol 3-Quinases , Humanos , Fosfatidilinositol 3-Quinases/metabolismo , Atrofia Muscular/metabolismo , Atrofia Muscular/patologia , Músculo Esquelético/metabolismo , Mitocôndrias/metabolismo , Transdução de Sinais , Coativador 1-alfa do Receptor gama Ativado por Proliferador de Peroxissomo/metabolismo
3.
Magn Reson Med ; 90(3): 1101-1113, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37158318

RESUMO

PURPOSE: Three-dimensional UTE MRI has shown the ability to provide simultaneous structural and functional lung imaging, but it is limited by respiratory motion and relatively low lung parenchyma SNR. The purpose of this paper is to improve this imaging by using a respiratory phase-resolved reconstruction approach, named motion-compensated low-rank reconstruction (MoCoLoR), which directly incorporates motion compensation into a low-rank constrained reconstruction model for highly efficient use of the acquired data. THEORY AND METHODS: The MoCoLoR reconstruction is formulated as an optimization problem that includes a low-rank constraint using estimated motion fields to reduce the rank, optimizing over both the motion fields and reconstructed images. The proposed reconstruction along with XD and motion state-weighted motion-compensation (MostMoCo) methods were applied to 18 lung MRI scans of pediatric and young adult patients. The data sets were acquired under free-breathing and without sedation with 3D radial UTE sequences in approximately 5 min. After reconstruction, they went through ventilation analyses. Performance across reconstruction regularization and motion-state parameters were also investigated. RESULTS: The in vivo experiments results showed that MoCoLoR made efficient use of the data, provided higher apparent SNR compared with state-of-the-art XD reconstruction and MostMoCo reconstructions, and yielded high-quality respiratory phase-resolved images for ventilation mapping. The method was effective across the range of patients scanned. CONCLUSION: The motion-compensated low-rank regularized reconstruction approach makes efficient use of acquired data and can improve simultaneous structural and functional lung imaging with 3D-UTE MRI. It enables the scanning of pediatric patients under free-breathing and without sedation.


Assuntos
Imageamento Tridimensional , Pulmão , Adulto Jovem , Humanos , Criança , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Respiração
4.
Molecules ; 27(8)2022 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-35458651

RESUMO

Chenopodium quinoa Willd. is recognized to be an excellent nutrient with high nutritional content. However, few genotypes of quinoa were analyzed, so we found a knowledge gap in the comparison of quinoa seeds of different genotypes. This study aims to compare the physicochemical, antioxidant, and anticancer properties of seed oil from three C. quinoa genotypes. Seeds of three genotypes (white, red, and black) were extracted with hexane and compared in this study. The oil yields of these quinoa seeds were 5.68-6.19% which contained predominantly polyunsaturated fatty acids (82.78-85.52%). The total tocopherol content ranged from 117.29 to 156.67 mg/kg and mainly consisted of γ-tocopherol. Total phytosterols in the three oils ranged from 9.4 to 12.2 g/kg. Black quinoa seed oil had the highest phytosterols followed by red and white quinoas. The chemical profile of quinoa seed oils paralleled by their antioxidant and anticancer activities in vitro was positively correlated with the seed coat color. Black quinoa seed oil had the best antioxidant and anti-proliferation effect on HCT 116 cells by the induction of apoptosis in a dose-dependent manner, which may play more significant roles in the chemoprevention of cancer and other diseases related to oxidative stress as a source of functional foods.


Assuntos
Chenopodium quinoa , Fitosteróis , Antioxidantes/análise , Antioxidantes/farmacologia , Chenopodium quinoa/química , Genótipo , Fitosteróis/análise , Fitosteróis/farmacologia , Óleos de Plantas/química , Sementes/química
5.
Molecules ; 27(19)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36234873

RESUMO

Phenolic compounds from the flower of Clitoria ternatea L. (PCFCTL) were extracted using a high-speed shearing extraction technique and purified by AB-8 macroporous resins, and the phytochemical composition of the purified phenolic compounds from the flower of Clitoria ternatea L. (PPCFCTL) was then analyzed. Subsequently, its bioactivities including antioxidant properties, enzyme inhibitory activities, and antiproliferative activities against several tumor cell lines were evaluated. Results indicated that the contents of total phenolics, flavonoids, flavonols, flavanols, and phenolic acids in PPCFCTL were increased by 3.29, 4.11, 2.74, 2.43, and 2.96-fold, respectively, compared with those before being purified by AB-8 macroporous resins. The results showed PPCFCTL have significant antioxidant ability (measured by reducing power, RP, and ferric reducing antioxidant power method, FRAP) and good DPPH, ABTS+, and superoxide anion radical scavenging activities. They can also significantly inhibit lipase, α-amylase, and α-glucosidase. In addition, morphological changes of HeLa, HepG2, and NCI-H460 tumor cells demonstrated the superior antitumor performance of PPCFCTL. However, the acetylcholinesterase inhibitory activity was relatively weak. These findings suggest that PPCFCTL have important potential as natural antioxidant, antilipidemic, anti-glycemic and antineoplastic agents in health-promoting foods.


Assuntos
Clitoria , Acetilcolinesterase , Antioxidantes/química , Clitoria/química , Flavonoides/análise , Flavonoides/farmacologia , Flavonóis/análise , Flores/química , Lipase/análise , Fenóis/análise , Fenóis/farmacologia , Compostos Fitoquímicos/análise , Compostos Fitoquímicos/farmacologia , Extratos Vegetais/análise , Extratos Vegetais/farmacologia , Superóxidos/análise , alfa-Amilases , alfa-Glucosidases
6.
Magn Reson Med ; 83(4): 1208-1221, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31565817

RESUMO

PURPOSE: To develop a high-scanning efficiency, motion-corrected imaging strategy for free-breathing pulmonary MRI by combining an iterative motion-compensation reconstruction with a ultrashort echo time (UTE) acquisition called iMoCo UTE. METHODS: An optimized golden-angle ordering radial UTE sequence was used to continuously acquire data for 5 minutes. All readouts were grouped to different respiratory motion states based on self-navigator signals, and then motion-resolved data was reconstructed by XD golden-angle radial sparse parallel reconstruction. One state from the motion-resolved images was selected as a reference, and then motion fields from the other states to the reference were derived via nonrigid registration. Finally, all motion-resolved data and motion fields were reconstructed by using an iterative motion-compensation (MoCo) reconstruction with a total generalized variation sparse constraint. RESULTS: The iMoCo UTE strategy was evaluated in volunteers and nonsedated pediatric patient (4-6 years old) studies. Images reconstructed with iMoCo UTE provided sharper anatomical lung structures and higher apparent SNR and contrast-to-noise ratio compared to using other motion-correction strategies, such as soft-gating, motion-resolved reconstruction, and nonrigid MoCo. iMoCo UTE also showed promising results in an infant study. CONCLUSION: The proposed iMoCo UTE combines self-navigation, motion modeling, and a compressed sensing reconstruction to increase scan efficiency and SNR and to reduce respiratory motion in lung MRI. This proposed strategy shows improvements in free-breathing lung MRI scans, especially in very challenging application situations such as pediatric MRI studies.


Assuntos
Artefatos , Imageamento Tridimensional , Criança , Pré-Escolar , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Respiração
7.
Magn Reson Med ; 84(4): 1763-1780, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32270547

RESUMO

PURPOSE: To develop a framework to reconstruct large-scale volumetric dynamic MRI from rapid continuous and non-gated acquisitions, with applications to pulmonary and dynamic contrast-enhanced (DCE) imaging. THEORY AND METHODS: The problem considered here requires recovering 100 gigabytes of dynamic volumetric image data from a few gigabytes of k-space data, acquired continuously over several minutes. This reconstruction is vastly under-determined, heavily stressing computing resources as well as memory management and storage. To overcome these challenges, we leverage intrinsic three-dimensional (3D) trajectories, such as 3D radial and 3D cones, with ordering that incoherently cover time and k-space over the entire acquisition. We then propose two innovations: (a) A compressed representation using multiscale low-rank matrix factorization that constrains the reconstruction problem, and reduces its memory footprint. (b) Stochastic optimization to reduce computation, improve memory locality, and minimize communications between threads and processors. We demonstrate the feasibility of the proposed method on DCE imaging acquired with a golden-angle ordered 3D cones trajectory and pulmonary imaging acquired with a bit-reversed ordered 3D radial trajectory. We compare it with "soft-gated" dynamic reconstruction for DCE and respiratory-resolved reconstruction for pulmonary imaging. RESULTS: The proposed technique shows transient dynamics that are not seen in gating-based methods. When applied to datasets with irregular, or non-repetitive motions, the proposed method displays sharper image features. CONCLUSIONS: We demonstrated a method that can reconstruct massive 3D dynamic image series in the extreme undersampling and extreme computation setting.


Assuntos
Meios de Contraste , Interpretação de Imagem Assistida por Computador , Algoritmos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética
8.
Magn Reson Med ; 84(6): 2943-2952, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32697867

RESUMO

PURPOSE: To ameliorate tradeoffs between a fixed spatial resolution and signal-to-noise ratio (SNR) for hyperpolarized 13 C MRI. METHODS: In MRI, SNR is proportional to voxel volume but retrospective downsampling or voxel averaging only improves SNR by the square root of voxel size. This can be exploited with a metabolite-selective imaging approach that independently encodes each compound, yielding high-resolution images for the injected substrate and coarser resolution images for downstream metabolites, while maintaining adequate SNR for each. To assess the efficacy of this approach, hyperpolarized [1-13 C]pyruvate data were acquired in healthy Sprague-Dawley rats (n = 4) and in two healthy human subjects. RESULTS: Compared with a constant resolution acquisition, variable-resolution data sets showed improved detectability of metabolites in pre-clinical renal studies with a 3.5-fold, 8.7-fold, and 6.0-fold increase in SNR for lactate, alanine, and bicarbonate data, respectively. Variable-resolution data sets from healthy human subjects showed cardiac structure and neuro-vasculature in the higher resolution pyruvate images (6.0 × 6.0 mm2 for cardiac and 7.5 × 7.5 mm2 for brain) that would otherwise be missed due to partial-volume effects and illustrates the level of detail that can be achieved with hyperpolarized substrates in a clinical setting. CONCLUSION: We developed a variable-resolution strategy for hyperpolarized 13 C MRI using metabolite-selective imaging and demonstrated that it mitigates tradeoffs between a fixed spatial resolution and SNR for hyperpolarized substrates, providing both high resolution pyruvate and coarse resolution metabolite data sets in a single exam. This technique shows promise to improve future studies by maximizing metabolite SNR while minimizing partial-volume effects from the injected substrate.


Assuntos
Imageamento por Ressonância Magnética , Ácido Pirúvico , Animais , Isótopos de Carbono , Ratos , Ratos Sprague-Dawley , Estudos Retrospectivos , Razão Sinal-Ruído
9.
Magn Reson Med ; 81(3): 2001-2010, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30368893

RESUMO

PURPOSE: To develop a pulse sequence to dynamically measure the ADC of hyperpolarized substrates during their perfusion, metabolic conversion, and transport. METHODS: We proposed a slice-selective double spin echo sequence for dynamic hyperpolarized 13 C diffusion-weighted imaging. The proposed pulse sequence was optimized for a high field preclinical scanner through theoretical analysis and simulation. The performance of the method was compared to non-slice-selective double spin echo via in vivo studies. We also validated the sequence for dynamic ADC measurement in both phantom studies and transgenic mouse model of prostate cancer studies. RESULTS: The optimized pulse sequence outperforms the traditional sequence with smaller saturation effects on the magnetization of hyperpolarized compounds that allowed more dynamic imaging frames covering a longer imaging time window. In pre-clinical studies (N = 8), the dynamic hyperpolarized lactate ADC maps of 6 studies in the prostate tumors showed an increase measured ADC over time, which might be related to lactate efflux from the tumor cells. CONCLUSIONS: The proposed sequence was validated and shown to improve dynamic diffusion weighted imaging compared to the traditional double spin echo sequence, providing ADC maps of lactate through time.


Assuntos
Espectroscopia de Ressonância Magnética Nuclear de Carbono-13/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Animais , Simulação por Computador , Ácido Láctico/metabolismo , Masculino , Camundongos , Camundongos Transgênicos , Modelos Teóricos , Imagens de Fantasmas , Piruvatos/metabolismo
10.
Magn Reson Med ; 81(2): 839-851, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30277268

RESUMO

PURPOSE: Acquisition timing and B1 calibration are two key factors that affect the quality and accuracy of hyperpolarized 13 C MRI. The goal of this project was to develop a new approach using regional bolus tracking to trigger Bloch-Siegert B1 mapping and real-time B1 calibration based on regional B1 measurements, followed by dynamic imaging of hyperpolarized 13 C metabolites in vivo. METHODS: The proposed approach was implemented on a system which allows real-time data processing and real-time control on the sequence. Real-time center frequency calibration upon the bolus arrival was also added. The feasibility of applying the proposed framework for in vivo hyperpolarized 13 C imaging was tested on healthy rats, tumor-bearing mice and a healthy volunteer on a clinical 3T scanner following hyperpolarized [1-13 C]pyruvate injection. Multichannel receive coils were used in the human study. RESULTS: Automatic acquisition timing based on either regional bolus peak or bolus arrival was achieved with the proposed framework. Reduced blurring artifacts in real-time reconstructed images were observed with real-time center frequency calibration. Real-time computed B1 scaling factors agreed with real-time acquired B1 maps. Flip angle correction using B1 maps results in a more consistent quantification of metabolic activity (i.e, pyruvate-to-lactate conversion, kPL ). Experiment recordings are provided to demonstrate the real-time actions during the experiment. CONCLUSIONS: The proposed method was successfully demonstrated on animals and a human volunteer, and is anticipated to improve the efficient use of the hyperpolarized signal as well as the accuracy and robustness of hyperpolarized 13 C imaging.


Assuntos
Isótopos de Carbono/química , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Animais , Mapeamento Encefálico , Calibragem , Modelos Animais de Doenças , Voluntários Saudáveis , Humanos , Masculino , Camundongos , Transplante de Neoplasias , Distribuição Normal , Reconhecimento Automatizado de Padrão , Neoplasias da Próstata/diagnóstico por imagem , Ácido Pirúvico , Ratos
11.
Magn Reson Med ; 79(1): 62-70, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29080236

RESUMO

PURPOSE: To develop a novel acquisition and reconstruction method for magnetization-prepared 3-dimensional multicontrast rapid gradient-echo imaging, using Hankel matrix completion in combination with compressed sensing and parallel imaging. METHODS: A random k-space shuffling strategy was implemented in simulation and in vivo human experiments at 7 T for 3-dimensional inversion recovery, T2 /diffusion preparation, and magnetization transfer imaging. We combined compressed sensing, based on total variation and spatial-temporal low-rank regularizations, and parallel imaging with pixel-wise Hankel matrix completion, allowing the reconstruction of tens of multicontrast 3-dimensional images from 3- or 6-min scans. RESULTS: The simulation result showed that the proposed method can reconstruct signal-recovery curves in each voxel and was robust for typical in vivo signal-to-noise ratio with 16-times acceleration. In vivo studies achieved 4 to 24 times accelerations for inversion recovery, T2 /diffusion preparation, and magnetization transfer imaging. Furthermore, the contrast was improved by resolving pixel-wise signal-recovery curves after magnetization preparation. CONCLUSIONS: The proposed method can improve acquisition efficiencies for magnetization-prepared MRI and tens of multicontrast 3-dimensional images could be recovered from a single scan. Furthermore, it was robust against noise, applicable for recovering multi-exponential signals, and did not require any previous knowledge of model parameters. Magn Reson Med 79:62-70, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Meios de Contraste/química , Magnetismo , Algoritmos , Mapeamento Encefálico/métodos , Simulação por Computador , Compressão de Dados/métodos , Difusão , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Modelos Estatísticos , Estudos Prospectivos , Estudos Retrospectivos , Razão Sinal-Ruído
12.
J Stroke Cerebrovasc Dis ; 26(10): 2376-2382, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28666803

RESUMO

BACKGROUND: Recently, favorable outcomes from several randomized controlled trials of rapid endovascular treatment for acute ischemic stroke has emerged. OBJECTIVE: The aim of this retrospective study is to present our clinical experience in severe acute vertebrobasilar occlusion (AVBO) using intra-arterial treatment (IAT). METHODS: Twenty patients with ischemic stroke in the vertebrobasilar circulation treated by IAT between March 2011 and December 2014 were included. We retrospectively assessed National Institutes of Health Stroke Scale (NIHSS) score on admission and at discharge, Thrombolysis in Cerebral Infarction (TICI) scale, and clinical outcome using modified Rankin scale (mRs) at 90 days, and causes of stroke were prospectively assessed. RESULTS: The mean NIHSS score on admission was 26.4 ± 7.9 (range 9-33) points. The mean time from symptom onset to revascularization was 349.5 ± 124.0 (range 201-579) minutes. Successful recanalization (TICI ≥2b) was achieved in 19 (95.0%) patients. The mean NIHSS score at discharge was 5.7 ± 9.0 (range 0-30) points. A favorable clinical outcome (mRS ≤2) was observed in 12 (60.0%) patients at 90 days and mortality was 25.0% (n = 5). CONCLUSION: IAT for AVBO provides high rate of recanalization, favorable clinical outcome, and improved survival.


Assuntos
Isquemia Encefálica/terapia , Revascularização Cerebral , Trombólise Mecânica , Stents , Acidente Vascular Cerebral/terapia , Adulto , Idoso , Artéria Basilar/diagnóstico por imagem , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento , Artéria Vertebral/diagnóstico por imagem
14.
Zhonghua Yi Xue Za Zhi ; 95(39): 3205-8, 2015 Oct 20.
Artigo em Zh | MEDLINE | ID: mdl-26814119

RESUMO

OBJECTIVE: To investigate the endovascular management strategy of mechanical thrombectomy using Solitaire AB stent for acute middle cerebral artery occlusion with atrial fibrillation and assess the safety and efficacy. METHODS: From June 2012 to Dec 2013, 40 patients of acute middle cerebral artery occlusion with atrial fibrillation admitted to our institutes were treated by Solitaire AB stent.Clinical status was evaluated by the score of National Institute of Health Stroke Scale (NIHSS) before and 72 hours after treatment, immediate scale of thrombolysis in cerebral infarction (TICI) after thrombectomy, the 90 d score of Modified Rankin Scale (mRS).The patients were classified into good result group (mRS≤2) and bad result group (mRS>2) according to the mRS score. RESULTS: Out of 40 cases, there were 28 cases caused by cardiogenic embolism. Recanalization was successful (TICI score 2b or 3) in 37 out of 40 (92.5%). 90 d follow-up mRS was 0-2 in 19 of 40 patients (47.5%). 3-5 in 21 patients (52.5%). 5 patients died (12.5%).Symptomatic hemorrhagic transform developed in 6 patients (15%).No complications related to the Solitaire AB thrombectomy occurred.Mean time from symptom onset to recanalization (312±52 min vs 370±68 min, P<0.05) and initial NIHSS score (17.0±0.4 vs 18.6±0.4, P<0.05) were of significant difference between good result group and bad result group. CONCLUSION: These results confirm that mechanical thrombectomy using solitaire AB stent for acute middle cerebral artery occlusion with atrial fibrillation is safe and effective.


Assuntos
Fibrilação Atrial , Infarto da Artéria Cerebral Média , Stents , Humanos , Trombectomia , Resultado do Tratamento
15.
Int J Biol Macromol ; 258(Pt 2): 128833, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128806

RESUMO

Natural polysaccharides exhibit numerous beneficial properties, such as antioxidant, antitumor, hypoglycemic, and hypolipidemic activities. Moringa oleifera seeds are of high dietary and therapeutic value which drew a lot of attention. However, the regulation effect on anti-inflammatory activity of polysaccharides remains to be studied. Herein, novel bioactive polysaccharides (MOSP-1) were extracted from Moringa oleifera seeds, and the anti-inflammatory properties of MOSP-1 were uncovered. Ultrasound-assisted extraction (UAE) was used to prepare the polysaccharides with optimized conditions (70 °C, 43 min, and liquid-solid-ratio 15 mL/g). Then, DEAE-Sepharose Fast Flow columns were applied to isolate and purify MOSP-1. Rhamnose, arabinose, galactose, and glucose were identified as the monosaccharide constituents of MOSP-1, with a molecular weight of 5.697 kDa. Their proportion in molarity was 1:0.183:0.108:0.860 and 8 types of glycosidic linkages were discovered. Bioactive assays showed that MOSP-1 possessed scavenging activities against DPPH and ABTS radicals, confirming its potential antioxidation efficacy. In vitro experiments revealed that MOSP-1 could reduce the expression of inflammation-related cytokines, inhibit the activation of ERK, JNK, and p38 (the MAPK signaling pathway), and enhance phagocytic functions. This study indicates that polysaccharides (MOSP-1) from Moringa oleifera seeds with anti-inflammatory properties may be used for functional food and pharmaceutical product development.


Assuntos
Moringa oleifera , Moringa oleifera/química , Ultrassom , Polissacarídeos/química , Antioxidantes/química , Anti-Inflamatórios , Sementes/química
16.
Bioengineering (Basel) ; 10(1)2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36671663

RESUMO

Manual prescription of the field of view (FOV) by MRI technologists is variable and prolongs the scanning process. Often, the FOV is too large or crops critical anatomy. We propose a deep learning framework, trained by radiologists' supervision, for automating FOV prescription. An intra-stack shared feature extraction network and an attention network are used to process a stack of 2D image inputs to generate scalars defining the location of a rectangular region of interest (ROI). The attention mechanism is used to make the model focus on a small number of informative slices in a stack. Then, the smallest FOV that makes the neural network predicted ROI free of aliasing is calculated by an algebraic operation derived from MR sampling theory. The framework's performance is examined quantitatively with intersection over union (IoU) and pixel error on position and qualitatively with a reader study. The proposed model achieves an average IoU of 0.867 and an average ROI position error of 9.06 out of 512 pixels on 80 test cases, significantly better than two baseline models and not significantly different from a radiologist. Finally, the FOV given by the proposed framework achieves an acceptance rate of 92% from an experienced radiologist.

17.
Front Nutr ; 10: 1158158, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37090775

RESUMO

Cyclocarya paliurus (C. paliurus), a nutritional and nutraceutical resource for human and animal diets, has been constantly explored. The available biological components of C. paliurus were triterpenoids, polysaccharides, and flavonoids. Recent studies in phytochemical-phytochemistry; pharmacological-pharmacology has shown that C. paliurus performed medicinal value, such as antihypertensive, antioxidant, anticancer, antimicrobial, anti-inflammatory and immunological activities. Furthermore, C. paliurus and its extracts added to drinks would help to prevent and mitigate chronic diseases. This review provides an overview of the nutritional composition and functional applications of C. paliurus, summarizing the research progress on the extraction methods, structural characteristics, and biological activities. Therefore, it may be a promising candidate for developing functional ingredients in traditional Chinese medicine. However, a more profound understanding of its active compounds and active mechanisms through which they perform biological activities is required. As a result, the plant needs further investigation in vitro and in vivo.

18.
J Agric Food Chem ; 71(12): 4817-4824, 2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-36935587

RESUMO

The goal of this study was to expand the applications of bamboo leaf flavonoids (BLFs) by improving their lipophilicity through enzymatic acylation with vinyl cinnamate. Characterization of the acylated BLFs using Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, high-resolution electrospray ionization mass spectrometry, electrospray ionization with tandem mass spectrometry, and 1H nuclear magnetic resonance spectroscopy indicated that acylation occurred at the C6-OH position of glucoside moieties. The highest degree of acylation (18.61%) was obtained by reacting BLFs with vinyl cinnamate (1:5, w/w) at 60 °C for 48 h. Acylation significantly improved the lipophilicity of BLFs and their capacity to inhibit lipid peroxidation, as evidenced by the reduced production of lipid hydroperoxides and malondialdehyde in rapeseed oil and rapeseed oil-in-water emulsions during storage at 37 °C for 15 days. The study findings provide important data that will enable the use of BLFs in lipid or lipophilic matrices, such as oil-based foods.


Assuntos
Antioxidantes , Flavonoides , Antioxidantes/química , Flavonoides/química , Óleo de Brassica napus , Acilação , Folhas de Planta/química
19.
Int J Cardiovasc Imaging ; 39(5): 1001-1011, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36648573

RESUMO

This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.


Assuntos
Aprendizado Profundo , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular
20.
bioRxiv ; 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37961357

RESUMO

Purpose: To evaluate methods for quantification of pulmonary ventilation with ultrashort echo time (UTE) MRI. Methods: We performed a reproducibility study, acquiring two free-breathing 1H UTE lung MRIs on the same day for six healthy volunteers. The 1) 3D + t cyclic b-spline and 2) symmetric image normalization (SyN) methods for image registration were applied after respiratory phase-resolved image reconstruction. Ventilation maps were calculated using 1) Jacobian determinant of the deformation fields minus one, termed regional ventilation, and 2) intensity percentage difference between the registered and fixed image, termed specific ventilation. We compared the reproducibility of all four method combinations via statistical analysis. Results: Split violin plots and Bland-Altman plots are shown for whole lungs and lung sections. The cyclic b-spline registration and Jacobian determinant regional ventilation quantification provide total ventilation volumes that match the segmentation tidal volume, smooth and uniform ventilation maps. The cyclic b-spline registration and specific ventilation combination yields the smallest standard deviation in the Bland-Altman plot. Conclusion: Cyclic registration performs better than SyN for respiratory phase-resolved 1H UTE MRI ventilation quantification. Regional ventilation correlates better with segmentation lung volume, while specific ventilation is more reproducible.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA