Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nature ; 584(7822): 619-623, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32581359

RESUMEN

Autoimmune thyroid disease is the most common autoimmune disease and is highly heritable1. Here, by using a genome-wide association study of 30,234 cases and 725,172 controls from Iceland and the UK Biobank, we find 99 sequence variants at 93 loci, of which 84 variants are previously unreported2-7. A low-frequency (1.36%) intronic variant in FLT3 (rs76428106-C) has the largest effect on risk of autoimmune thyroid disease (odds ratio (OR) = 1.46, P = 2.37 × 10-24). rs76428106-C is also associated with systemic lupus erythematosus (OR = 1.90, P = 6.46 × 10-4), rheumatoid factor and/or anti-CCP-positive rheumatoid arthritis (OR = 1.41, P = 4.31 × 10-4) and coeliac disease (OR = 1.62, P = 1.20 × 10-4). FLT3 encodes fms-related tyrosine kinase 3, a receptor that regulates haematopoietic progenitor and dendritic cells. RNA sequencing revealed that rs76428106-C generates a cryptic splice site, which introduces a stop codon in 30% of transcripts that are predicted to encode a truncated protein, which lacks its tyrosine kinase domains. Each copy of rs76428106-C doubles the plasma levels of the FTL3 ligand. Activating somatic mutations in FLT3 are associated with acute myeloid leukaemia8 with a poor prognosis and rs76428106-C also predisposes individuals to acute myeloid leukaemia (OR = 1.90, P = 5.40 × 10-3). Thus, a predicted loss-of-function germline mutation in FLT3 causes a reduction in full-length FLT3, with a compensatory increase in the levels of its ligand and an increased disease risk, similar to that of a gain-of-function mutation.


Asunto(s)
Codón sin Sentido/genética , Predisposición Genética a la Enfermedad/genética , Ligandos , Mutación , Tiroiditis Autoinmune/genética , Tirosina Quinasa 3 Similar a fms/genética , Tirosina Quinasa 3 Similar a fms/metabolismo , Alelos , Enfermedades Autoinmunes/genética , Bases de Datos Factuales , Estudio de Asociación del Genoma Completo , Mutación de Línea Germinal , Humanos , Islandia , Intrones/genética , Leucemia Mieloide Aguda , Mutación con Pérdida de Función , Sitios de Empalme de ARN/genética , Reino Unido
2.
Clin Gastroenterol Hepatol ; 21(2): 347-357.e10, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35977616

RESUMEN

BACKGROUND AND AIMS: While overall gastrointestinal bleeding (GIB) rates have been extensively compared between warfarin and direct oral anticoagulants (DOACs), it is still unclear whether upper and lower GIB rates differ between these types of drugs. This study aimed to compare upper and lower GIB rates between warfarin and DOACs in a nationwide cohort. METHODS: Data on all patients in Iceland who received a prescription for oral anticoagulation from 2014 to 2019 were collected and their personal identification numbers linked to the electronic medical record system of the National University Hospital of Iceland and the 4 regional hospitals in Iceland. Inverse probability weighting was used to yield balanced study groups and rates of overall, major, upper, and lower GIB were compared using Cox regression. All GIB events were manually confirmed by chart review. RESULTS: Warfarin was associated with higher rates of upper GIB (1.7 events per 100 person-years vs 0.8 events per 100 person-years; hazard ratio [HR], 2.12; 95% confidence interval [CI], 1.26-3.59) but similar rates of lower GIB compared with DOACs. Specifically, warfarin was associated with higher rates of upper GIB compared with apixaban (HR, 2.63; 95% CI, 1.35-5.13), dabigatran (5.47; 95% CI, 1.87-16.05), and rivaroxaban (HR, 1.74; 95% CI, 1.00-3.05). Warfarin was associated with higher rates of major GIB compared with apixaban (2.3 events per 100 person-years vs 1.5 events per 100 person-years; HR, 1.79; 95% CI, 1.06-3.05), but otherwise overall and major GIB rates were similar in warfarin and DOAC users. CONCLUSIONS: Warfarin was associated with higher rates of upper but not overall or lower GIB compared with DOACs. Warfarin was associated with higher rates of major GIB compared with apixaban.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Warfarina/efectos adversos , Anticoagulantes/efectos adversos , Estudios de Cohortes , Fibrilación Atrial/complicaciones , Hemorragia Gastrointestinal/inducido químicamente , Hemorragia Gastrointestinal/epidemiología , Hemorragia Gastrointestinal/complicaciones , Dabigatrán/efectos adversos , Administración Oral , Estudios Retrospectivos
3.
Blood ; 137(20): 2745-2755, 2021 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-33512454

RESUMEN

During warfarin management, variability in prothrombin time-based international normalized ratio (PT-INR) is caused, in part, by clinically inconsequential fluctuations in factor VII (FVII). The new factor II and X (Fiix)-prothrombin time (Fiix-PT) and Fiix-normalized ratio (Fiix-NR), unlike PT-INR, are only affected by reduced FII and FX. We assessed the incidence of thromboembolism (TE) and major bleeding (MB) in all 2667 patients on maintenance-phase warfarin managed at our anticoagulation management service during 30 months; 12 months prior to and 18 months after replacing PT-INR monitoring with Fiix-NR monitoring. Months 13 to 18 were predefined as transitional months. Using 2-segmented regression, a breakpoint in the monthly incidence of TE became evident 6 months after test replacement, that was followed by a 56% reduction in incidence (from 2.82% to 1.23% per patient-year; P = .019). Three-segmented regression did not find any significant trend in TE incidence (slope, +0.03) prior to test replacement; however, during months 13 to 18 and 19 to 30, the incidence of TE decreased gradually (slope, -0.12; R2 = 0.20; P = .007). The incidence of MB (2.79% per patient-year) did not differ. Incidence comparison during the 12-month Fiix and PT periods confirmed a statistically significant reduction (55-62%) in TE. Fiix monitoring reduced testing, dose adjustments, and normalized ratio variability and prolonged testing intervals and time in range. We conclude that ignoring FVII during Fiix-NR monitoring in real-world practice stabilizes the anticoagulant effect of warfarin and associates with a major reduction in TEs without increasing bleeding.


Asunto(s)
Anticoagulantes/uso terapéutico , Monitoreo de Drogas/métodos , Factor VII/análisis , Factor X/análisis , Hemorragia/inducido químicamente , Protrombina/análisis , Tromboembolia/prevención & control , Trombofilia/tratamiento farmacológico , Warfarina/uso terapéutico , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Anticoagulantes/farmacología , Fibrilación Atrial/complicaciones , Comorbilidad , Femenino , Estudios de Seguimiento , Humanos , Islandia/epidemiología , Relación Normalizada Internacional , Análisis de Series de Tiempo Interrumpido , Quimioterapia de Mantención , Masculino , Tiempo de Protrombina , Riesgo , Tromboembolia/epidemiología , Trombofilia/sangre , Trombofilia/epidemiología , Warfarina/efectos adversos , Warfarina/farmacología
4.
J Intern Med ; 292(3): 501-511, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35411982

RESUMEN

BACKGROUND: Although epistaxis is one of the most common side effects of oral anticoagulation, it is unclear whether epistaxis rates vary between different oral anticoagulants (OAC). OBJECTIVE: To compare rates of clinically relevant epistaxis between OAC. METHODS: Epistaxis event rates were compared between new users of apixaban, dabigatran, rivaroxaban, and warfarin in a nationwide population-based cohort study over a 5-year study period, 2014-2019. Data was collected from the Icelandic Medicine Registry and the five major hospitals in Iceland. Inverse probability weighting (IPW) was used to yield balanced baseline characteristics, and epistaxis rates were compared using Kaplan-Meier survival estimates and Cox regression. RESULTS: During the study period, 2098 patients received apixaban, 474 dabigatran, 3106 rivaroxaban, and 1403 warfarin. In total, 93 patients presented with clinically relevant epistaxis, including 11 (12%) major epistaxis events and one fatal epistaxis episode. Furthermore, seven patients (9%) with non-major epistaxis later presented with major bleeding during the follow-up period. Warfarin use was associated with higher rates of epistaxis compared to apixaban (2.2 events per 100-person years (events/100-py) vs. 0.6 events/100-py, hazard ratio [HR] 4.22, 95% confidence interval [CI] 2.08-8.59, p < 0.001), rivaroxaban (2.2 events/100-py vs. 1.0 events/100-py, HR 2.26, 95% CI 1.28-4.01, p = 0.005), and dabigatran (2.2 events/100-py vs. no events, HR n/a, p < 0.001). CONCLUSION: Warfarin treatment was associated with higher rates of clinically relevant epistaxis compared to direct oral anticoagulants.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Administración Oral , Anticoagulantes/uso terapéutico , Fibrilación Atrial/complicaciones , Estudios de Cohortes , Dabigatrán , Epistaxis/inducido químicamente , Epistaxis/complicaciones , Epistaxis/epidemiología , Humanos , Puntaje de Propensión , Piridonas , Estudios Retrospectivos , Rivaroxabán , Accidente Cerebrovascular/tratamiento farmacológico , Warfarina
5.
Haemophilia ; 28(4): 642-648, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35510959

RESUMEN

INTRODUCTION: Platelet function tests are used to screen and diagnose patients with possible inherited platelet function defects (IPFD). Some acquired platelet dysfunction may be caused by certain drugs or comorbidities, which need to be excluded before testing. AIMS: To identify current practice among centres performing platelet function tests in Northern Europe. METHODS: A total of 14 clinical centres from Sweden (six), Finland (two), Denmark (two), Norway (one), Estonia (two) and Iceland (one) completed the survey questionnaire, the population capture area of about 29.5 million. RESULTS: Six of the 14 (42.8%) centres providing platelet function assessment represent comprehensive treatment centres (EUHANET status). A Bleeding score (BS) or ISTH bleeding assessment tool (ISTH BAT score) is evaluated in 11/14 (78.6%) centres and family history in all. Five/14 centres (35.7%) use structured preanalytical patient instructions, and 10/14 (71.4%) recorded questionnaire on the preassessment of avoidance of any drugs or natural products affecting platelet functions. Preliminary investigations of screening tests of coagulation are performed in 10/14 (71.4%), while in 4/14 (28.6%), the diagnostic work-up of IPFD and von Willebrand disease (VWD) is performed simultaneously. The work-up of IPFD includes peripheral blood smear in 10/14 (71.4%), platelet aggregometry in all, flow cytometry in 10/14 (71.4%) and Platelet Function Analysis (PFA) in 3/11 (28.6%). Molecular genetic diagnosis is available in 7/14 (50%) centres. CONCLUSIONS: The considerable variability in the current practice illustrates the need for harmonization between the Northern European centres according to the international registers (i.e. EUHASS) and IPFD guidelines (ISTH, EHA).


Asunto(s)
Trastornos de las Plaquetas Sanguíneas , Enfermedades de von Willebrand , Trastornos de las Plaquetas Sanguíneas/diagnóstico , Plaquetas , Europa (Continente) , Hemorragia/diagnóstico , Humanos , Pruebas de Función Plaquetaria , Enfermedades de von Willebrand/diagnóstico
6.
Ann Intern Med ; 174(11): 1493-1502, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34633836

RESUMEN

BACKGROUND: Gastrointestinal bleeding (GIB) rates for direct oral anticoagulants (DOACs) and warfarin have been extensively compared. However, population-based studies comparing GIB rates among different DOACs are limited. OBJECTIVE: To compare rates of GIB among apixaban, dabigatran, and rivaroxaban. DESIGN: Nationwide population-based cohort study. SETTING: Landspítali-The National University Hospital of Iceland and the 4 regional hospitals in Iceland. PATIENTS: New users of apixaban, dabigatran, and rivaroxaban from 2014 to 2019. MEASUREMENTS: Rates of GIB were compared using inverse probability weighting, Kaplan-Meier survival estimates, and Cox regression. RESULTS: In total, 2157 patients receiving apixaban, 494 patients receiving dabigatran, and 3217 patients receiving rivaroxaban were compared. For all patients, rivaroxaban had higher overall rates of GIB (3.2 vs. 2.5 events per 100 person-years; hazard ratio [HR], 1.42 [95% CI, 1.04 to 1.93]) and major GIB (1.9 vs. 1.4 events per 100 person-years; HR, 1.50 [CI, 1.00 to 2.24]) compared with apixaban. Rivaroxaban also had higher GIB rates than dabigatran, with similar point estimates, although the CIs were wider and included the possibility of a null effect. When only patients with atrial fibrillation were included, rivaroxaban was associated with higher rates of overall GIB than apixaban (HR, 1.40 [CI, 1.01 to 1.94]) or dabigatran (HR, 2.04 [CI, 1.17 to 3.55]). Dabigatran was associated with lower rates of upper GIB than rivaroxaban in both analyses. LIMITATIONS: Unmeasured confounding and small subgroup analyses. CONCLUSION: Rivaroxaban was associated with higher GIB rates than apixaban and dabigatran regardless of treatment indication. PRIMARY FUNDING SOURCE: Icelandic Centre for Research and Landspítali-The National University Hospital of Iceland.


Asunto(s)
Inhibidores del Factor Xa/efectos adversos , Hemorragia Gastrointestinal/inducido químicamente , Rivaroxabán/efectos adversos , Anciano , Estudios de Cohortes , Dabigatrán/efectos adversos , Enfermedades del Sistema Digestivo/complicaciones , Enfermedades del Sistema Digestivo/epidemiología , Femenino , Estudios de Seguimiento , Hemorragia Gastrointestinal/epidemiología , Humanos , Islandia/epidemiología , Masculino , Puntaje de Propensión , Pirazoles/efectos adversos , Piridonas/efectos adversos , Úlcera/complicaciones , Úlcera/epidemiología
7.
Hum Mol Genet ; 28(7): 1199-1211, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30476138

RESUMEN

Urine dipstick tests are widely used in routine medical care to diagnose kidney and urinary tract and metabolic diseases. Several environmental factors are known to affect the test results, whereas the effects of genetic diversity are largely unknown. We tested 32.5 million sequence variants for association with urinary biomarkers in a set of 150 274 Icelanders with urine dipstick measurements. We detected 20 association signals, of which 14 are novel, associating with at least one of five clinical entities defined by the urine dipstick: glucosuria, ketonuria, proteinuria, hematuria and urine pH. These include three independent glucosuria variants at SLC5A2, the gene encoding the sodium-dependent glucose transporter (SGLT2), a protein targeted pharmacologically to increase urinary glucose excretion in the treatment of diabetes. Two variants associating with proteinuria are in LRP2 and CUBN, encoding the co-transporters megalin and cubilin, respectively, that mediate proximal tubule protein uptake. One of the hematuria-associated variants is a rare, previously unreported 2.5 kb exonic deletion in COL4A3. Of the four signals associated with urine pH, we note that the pH-increasing alleles of two variants (POU2AF1, WDR72) associate significantly with increased risk of kidney stones. Our results reveal that genetic factors affect variability in urinary biomarkers, in both a disease dependent and independent context.


Asunto(s)
Biomarcadores/análisis , Biomarcadores/orina , Variación Genética/genética , Adulto , Anciano , Alelos , Femenino , Hematuria/genética , Hematuria/orina , Humanos , Concentración de Iones de Hidrógeno , Islandia , Cetosis/genética , Cetosis/orina , Riñón/metabolismo , Masculino , Persona de Mediana Edad , Proteinuria/genética , Proteinuria/orina , Transportador 2 de Sodio-Glucosa/genética , Secuenciación Completa del Genoma/métodos
8.
Transfusion ; 61(1): 202-211, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33166431

RESUMEN

BACKGROUND: Therapeutic phlebotomy is the standard treatment of hereditary hemochromatosis (HH), the most common genetic disease in people of Northern European descent. Red cell concentrates from HH donors have been reported safe for transfusion, but little data is available on the storage properties of platelet concentrates from HH donors. STUDY DESIGN AND METHODS: Whole blood was collected from 10 healthy individuals and 10 newly diagnosed HH patients with elevated serum ferritin. Platelet-rich plasma (PRP) was prepared and split into four 20-mL units. Platelet quality tests were performed on days 0, 1, 3, 5, and 7 of storage, including platelet aggregation (ADP, arachidonic acid, collagen, and epinephrine agonists), blood gas analysis, flow cytometry (CD41, CD42b, and CD62P expression), and ELISA (sCD40L and sCD62p in supernatant). RESULTS: Mean serum ferritin levels were higher in HH patients than in controls (847.5 vs 45.8 ng/mL, P < .001). Overall, no difference in quality test results was observed between the two study groups over 7-day storage (P > .05), including blood gas analysis, platelet aggregation, and expression of surface (CD62p and CD42b) and secreted (sCD62P and sCD40L) activation markers. Expected alterations in metabolic (CO2 and glucose decrease, O2 and lactate increase, P < .001) and platelet activation markers (CD42b decrease, CD62P increase, P < .05) over time were observed in both groups. CONCLUSION: Although these findings indicate that platelets of individuals with HH are comparable to platelets from healthy donors, more extensive studies are needed before definite conclusions can be drawn.


Asunto(s)
Donantes de Sangre/estadística & datos numéricos , Plaquetas/citología , Conservación de la Sangre/métodos , Hemocromatosis/diagnóstico , Adulto , Análisis de los Gases de la Sangre/métodos , Plaquetas/fisiología , Conservación de la Sangre/estadística & datos numéricos , Femenino , Ferritinas/sangre , Citometría de Flujo/métodos , Voluntarios Sanos , Hemocromatosis/sangre , Hemocromatosis/etnología , Hemocromatosis/terapia , Humanos , Masculino , Persona de Mediana Edad , Selectina-P/metabolismo , Flebotomía/métodos , Activación Plaquetaria/fisiología , Agregación Plaquetaria/fisiología , Pruebas de Función Plaquetaria/métodos , Complejo GPIb-IX de Glicoproteína Plaquetaria/metabolismo , Plasma Rico en Plaquetas/metabolismo
9.
Thromb J ; 19(1): 72, 2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34654442

RESUMEN

The antithrombotic effect of vitamin K antagonists (VKA) depends on controlled lowering of the activity of factors (F) II and X whereas reductions in FVII and FIX play little role. PT-INR based monitoring, however, is highly influenced by FVII, which has the shortest half-life of vitamin K-dependent coagulation factors. Hence, variability in the anticoagulant effect of VKA may be partly secondary to an inherent flaw of the traditional monitoring test itself. The Fiix prothrombin time (Fiix-PT) is a novel test that is only sensitive to reductions in FII and FX and is intended to stabilize the VKA effect. Two clinical studies have now demonstrated that when warfarin is monitored with the Fiix-PT based normalized ratio (Fiix-NR) instead of PT-INR, anticoagulation is stabilized and less testing and fewer dose adjustments are needed. Furthermore, the relative risk of thromboembolism was reduced by 50-56% in these studies without an increase in major bleeding.

10.
J Thromb Thrombolysis ; 48(4): 685-689, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31401717

RESUMEN

The new Fiix prothrombin time (Fiix-PT) and its derived Fiix-normalized ratio (Fiix-NR) is affected only by reductions in coagulation factors (F) II and X, the two factors responsible for the antithrombotic effect of vitamin K antagonists (VKA). Due to insensitivity to reductions in the short half-life FVII, the Fiix-NR rises later than standard PT-INR during warfarin initiation. To describe a warfarin initiation nomogram adapted for monitoring with Fiix-NR, anticoagulation development was assessed during use of standard PT-INR based initiation nomogram and after adapting the initiation nomogram for Fiix-NR monitoring. Normalized ratios were retrospectively assessed in consecutive warfarin naïve patients during their first 60 days of warfarin intake for one year prior to (PT-INR period) and for one year after replacing the PT-INR with the Fiix-NR (Fiix-NR period). The INR target was NR 2.0-3.0. We evaluated 160 patients monitored with PT-INR and dosed with the PT-nomogram, 57 monitored with Fiix-INR but dosed with PT-nomogram, and 163 Fiix-NR monitored patients dosed using a new Fiix nomogram. Mean PT-INR over 2.0 was reached on day 7 during the PT-period and remained around 2.5 thereafter. When the PT-nomogram continued in use during Fiix-monitoring significantly more patients became overanticoagulated during days 11-29. After the nomogram was modified to respond to rising Fiix-NR with larger initial dose reduction, the mean Fiix-NR reached over 2 on day 8-9 and remained around 2.5 thereafter. When warfarin is monitored with Fiix-NR, an adjusted dosing nomogram should be used during initiation to prevent early overanticoagulation.


Asunto(s)
Monitoreo de Drogas/métodos , Nomogramas , Tiempo de Protrombina , Warfarina/administración & dosificación , Humanos , Relación Normalizada Internacional , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA