Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Ann Emerg Med ; 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38888531

RESUMEN

STUDY OBJECTIVE: The real-world effectiveness and safety of a 0/1-hour accelerated protocol using high-sensitivity cardiac troponin (hs-cTn) to exclude myocardial infarction (MI) compared to routine care in the United States is uncertain. The objective was to compare a 0/1-hour accelerated protocol for evaluation of MI to a 0/3-hour standard care protocol. METHODS: The RACE-IT trial was a stepped-wedge, randomized trial across 9 emergency departments (EDs) that enrolled 32,609 patients evaluated for possible MI from July 2020 through April 2021. Patients undergoing high-sensitivity cardiac troponin I testing with concentrations less than or equal to 99th percentile were included. Patients who had MI excluded by the 0/1-hour protocol could be discharged from the ED. Patients in the standard care protocol had 0- and 3-hour troponin testing and application of a modified HEART score to be eligible for discharge. The primary endpoint was the proportion of patients discharged from the ED without 30-day death or MI. RESULTS: There were 13,505 and 19,104 patients evaluated in the standard care and accelerated protocol groups, respectively, of whom 19,152 (58.7%) were discharged directly from the ED. There was no significant difference in safe discharges between standard care and the accelerated protocol (59.5% vs 57.8%; adjusted odds ratio (aOR)=1.05, 95% confidence interval [CI] 0.95 to 1.16). At 30 days, there were 90 deaths or MIs with 38 (0.4%) in the standard care group and 52 (0.4%) in the accelerated protocol group (aOR=0.84, 95% CI 0.43 to 1.68). CONCLUSION: A 0/1-hour accelerated protocol using high-sensitivity cardiac troponin I did not lead to more safe ED discharges compared with standard care.

2.
Catheter Cardiovasc Interv ; 100(1): 163-168, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35568977

RESUMEN

OBJECTIVE: We aim to report on the efficacy and safety of large bore venous access (LBVA) preclosure with Perclose™ (Abbott Vascular Devices) suture-mediated device use following transcatheter edge-to-edge (TEER) and replacement (TMVR). BACKGROUND: Patients requiring TEER and TMVR require LBVA. Clinical outcome data on the use of suture-mediated devices for LBVA site closure are limited. METHODS: Between 2012 and 2019, 354 consecutive high-risk patients with mitral valvular heart disease underwent TEER (n = 287) with MitraClip and TMVR (n = 67) with Edwards Sapien Valves. Patients had LBVA with 24 or 16 French sheaths. All patients underwent preclosure of LBVA except for one that underwent manual hemostasis. RESULTS: There were no closure device failures. None of the cases required surgical repair of the access site following venous preclosure. Two cases had large hematomas (>6 cm) following Perclose in each group. Six cases had small hematomas (<6 cm and >2 cm) with three in each group. There was one major bleeding using Mitral Valve Academic Research Consortium 2 definition (retroperitoneal bleed from arterial puncture) unrelated to the venous closure. Transfusion related to vascular access complication was required in five cases. There were two immediate acute deep venous thromboses postprocedure; one of which occurred after preclosure. There were no arteriovenous malformations, pseudoaneurysms, or access site infections reported following Perclose. CONCLUSION: In this large sample size analysis, Proglide preclosure technique is a feasible and safe alternative approach to achieving hemostasis after removal of LBVA sheaths in patients undergoing TEER and TMVR. Randomized trials are needed to compare the different modalities of hemostasis.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Dispositivos de Cierre Vascular , Enfermedades de las Válvulas Cardíacas/cirugía , Hematoma/etiología , Hemorragia/etiología , Hemorragia/prevención & control , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Técnicas de Sutura/efectos adversos , Resultado del Tratamiento , Dispositivos de Cierre Vascular/efectos adversos
3.
Crit Care Explor ; 4(6): e0717, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35747122

RESUMEN

To investigate the relationship between oliguric acute kidney injury (AKI) and mortality in patients with acute respiratory distress syndrome (ARDS). DESIGN: Retrospective cohort study. SETTING: This investigation took place at a single-center, tertiary referral multidisciplinary comprehensive healthcare hospital in metropolitan Detroit, Michigan. PATIENTS: Adult patients 18 years old or older hospitalized in the ICU and diagnosed with ARDS on mechanical ventilation. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Three hundred eight patients were included in the final analysis. Risk factors associated with mortality included advanced age (p < 0.001), increased body mass index (p = 0.008), and a history of chronic kidney disease (p = 0.023). Presence of AKI by day 1 of intubation, with elevated creatinine (p = 0.003) and oliguria (p < 0.001), was significantly associated with mortality. On multivariate analysis, advanced age (relative risk [RR], 1.02), urine output on the day of intubation (RR, 0.388), bicarbonate level (RR, 0.948), and Sequential Organ Failure Assessment severity score (RR, 1.09) were independently associated with mortality. A receiver operating characteristic curve identified a threshold urine output on the day of intubation of 0.7 mL/kg/hr (area under the curve, 0.75; p < 0.001) as most closely associated with inpatient mortality (i.e., urine output < 0.7 mL/kg/hr is associated with mortality). CONCLUSIONS: For patients with ARDS, oliguria on the day of intubation was independently associated with increased mortality. Urine output of less than 0.7 mL/kg/hr predicted 80% of inpatient deaths. These findings herald an augmented understanding of the role of urine output in medical decision-making and prognostication.

4.
Clin Pract Cases Emerg Med ; 4(2): 164-166, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32426662

RESUMEN

Cystic echinococcosis (CE) is an infection caused by the Echinococcus granulosus tapeworm. CE generally manifests in the liver, but it may present in any organ. These patients often first present to the emergency department. Mortality over 10 years is significant for those who go undiagnosed. We report the case of a 34-year-old patient who immigrated from Yemen six years earlier. She presented with acute onset dysuria, suprapubic pain, and fever. Imaging revealed a primary multicystic mass on the right renal pole with a secondary lesion in the right hepatic lobe. On further investigation, the patient's serum was positive for echinococcus antibodies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA