Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Biosens Bioelectron ; 22(9-10): 2100-7, 2007 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-17055239

RESUMEN

Field-effect-based capacitive electrolyte-insulator-semiconductor (EIS) sensors have been utilised for the deoxyribonucleic acid (DNA) immobilisation and hybridisation detection as well as for monitoring the layer-by-layer adsorption of polyelectrolytes (anionic poly(sodium 4-styrene sulfonate) (PSS) and cationic poly(allylamine hydrochloride) (PAH)). The EIS sensors with charged macromolecules have been systematically characterised by capacitance-voltage, constant-capacitance, impedance spectroscopy and atomic-force microscopy methods. The effect of the number and polarity of the polyelectrolyte layers on the shift of the capacitance-voltage curves has been investigated. Alternating potential shifts of about 30-90 mV have been observed after the adsorption of each polyanion and polycation layer, respectively. The DNA immobilisation and hybridisation signals were 35-55 and 24-33 mV, respectively. The possible mechanisms for the sensor responses are discussed.


Asunto(s)
ADN/química , Capacidad Eléctrica , Microscopía de Fuerza Atómica , Hibridación de Ácido Nucleico , Impedancia Eléctrica , Poliaminas , Polímeros , Ácidos Sulfónicos
2.
Biosens Bioelectron ; 26(6): 3023-8, 2011 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-21193303

RESUMEN

An array of individually addressable nanoplate field-effect capacitive (bio-)chemical sensors based on an SOI (silicon-on-insulator) structure has been developed. The isolation of the individual capacitors was achieved by forming a trench in the top Si layer with a thickness of 350 nm. The realized sensor array allows addressable biasing and electrical readout of multiple nanoplate EISOI (electrolyte-insulator-silicon-on-insulator) capacitive biosensors on the same SOI chip as well as differential-mode measurements. The feasibility of the proposed approach has been demonstrated by realizing sensors for the pH and penicillin concentration detection as well as for the label-free electrical monitoring of polyelectrolyte multilayers formation and DNA (deoxyribonucleic acid)-hybridization event. A potential change of ∼ 120 mV has been registered after the DNA hybridization for the sensor immobilized with perfectly matched single-strand DNA, while practically no signal changes have been observed for a sensor with fully mismatched DNA. The realized examples demonstrate the potential of the nanoplate SOI capacitors as a new basic structural element for the development of different types of field-effect biosensors.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Nanoestructuras/química , Silicio , Secuencia de Bases , ADN/análisis , ADN/genética , Sondas de ADN/genética , Capacidad Eléctrica , Técnicas Electroquímicas , Concentración de Iones de Hidrógeno , Microtecnología , Nanotecnología , Hibridación de Ácido Nucleico , Penicilinas/análisis
3.
Biosens Bioelectron ; 24(5): 1298-304, 2009 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-18801654

RESUMEN

The feasibility of a capacitive field-effect EDIS (electrolyte-diamond-insulator-semiconductor) platform for multi-parameter sensing is demonstrated by realising EDIS sensors with an O-terminated nanocrystalline-diamond (NCD) film as transducer material for the detection of pH and penicillin concentration as well as for the label-free electrical monitoring of adsorption and binding of charged macromolecules, like polyelectrolytes. The NCD films were grown on p-Si-SiO(2) substrates by microwave plasma-enhanced chemical vapour deposition. To obtain O-terminated surfaces, the NCD films were treated in an oxidising medium. The NCD-based field-effect sensors have been characterised by means of constant-capacitance method. The average pH sensitivity of the O-terminated NCD film was 40 mV/pH. A low detection limit of 5 microM and a high penicillin G sensitivity of 65-70 mV/decade has been obtained for an EDIS penicillin biosensor with the adsorptively immobilised enzyme penicillinase. Alternating potential changes, having tendency to decrease with increasing the number of adsorbed polyelectrolyte layers, have been observed after the layer-by-layer deposition of polyelectrolyte multilayers, using positively charged PAH (poly (allylamine hydrochloride)) and a negatively charged PSS (poly (sodium 4-styrene sulfonate)) as a model system. The response mechanism of the developed EDIS sensors is discussed.


Asunto(s)
Técnicas Biosensibles/instrumentación , Diamante/química , Electroquímica/instrumentación , Microelectrodos , Nanoestructuras/química , Penicilinasa/química , Penicilinas/análisis , Transductores , Técnicas Biosensibles/métodos , Capacidad Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Membranas Artificiales , Nanoestructuras/ultraestructura , Penicilinas/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA