Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Pharm Sci ; 112(11): 2834-2842, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37220827

RESUMEN

This paper reports the results of the active pharmaceutical ingredient (API) fingerprint study, organised by the General European Official Medicines Control Laboratory Network (GEON), on tadalafil. A classical market surveillance study, evaluating compliance to the European Pharmacopoeia, was combined with a fingerprint study, the latter to obtain characteristic data for the different manufacturers, allowing the network laboratories to conduct authenticity tests for future samples, as well as to detect substandard and falsified samples. In total, 46 tadalafil API samples from 13 different manufacturers were collected. For all samples fingerprint data was collected through analysis of impurities and residual solvents, mass spectrometric screening, X-ray powder diffraction and proton nuclear magnetic resonance (1H-NMR). Chemometric analysis revealed that all manufacturers could be characterised based on the impurity, residual solvent and 1H-NMR data. Future suspicious samples in the network will therefore be analysed with these techniques in order to attribute the sample to one of the manufacturers. If the sample cannot be attributed, a more profound investigation will be necessary to reveal the origin of the sample. In cases where the suspect sample is claimed to be from one of the manufacturers included in this study, analysis can be limited to the test distinguishing that manufacturer.

2.
Anal Bioanal Chem ; 403(4): 1117-29, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22318699

RESUMEN

The excessive and continuously growing interest in the simultaneous determination of poppy alkaloids imposes the development and optimization of convenient high-throughput methods for the assessment of the qualitative and quantitative profile of alkaloids in poppy straw. Systematic optimization of two chromatographic methods (gas chromatography (GC)/flame ionization detector (FID)/mass spectrometry (MS) and reversed-phase (RP)-high-performance liquid chromatography (HPLC)/diode array detector (DAD)) for the separation of alkaloids from Papaver somniferum L. (Papaveraceae) was carried out. The effects of various conditions on the predefined chromatographic descriptors were investigated using chemometrics. A full factorial linear design of experiments for determining the relationship between chromatographic conditions and the retention behavior of the analytes was used. Central composite circumscribed design was utilized for the final method optimization. By conducting the optimization of the methods in very rational manner, a great deal of excessive and unproductive laboratory research work was avoided. The developed chromatographic methods were validated and compared in line with the resolving power, sensitivity, accuracy, speed, cost, ecological aspects, and compatibility with the poppy straw extraction procedure. The separation of the opium alkaloids using the GC/FID/MS method was achieved within 10 min, avoiding any derivatization step. This method has a stronger resolving power, shorter analysis time, better cost/effectiveness factor than the RP-HPLC/DAD method and is in line with the "green trend" of the analysis. The RP-HPLC/DAD method on the other hand displayed better sensitivity for all tested alkaloids. The proposed methods provide both fast screening and an accurate content assessment of the six alkaloids in the poppy samples obtained from the selection program of Papaver strains.


Asunto(s)
Alcaloides/análisis , Alcaloides/aislamiento & purificación , Cromatografía de Gases/métodos , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/métodos , Opio/análisis , Opio/aislamiento & purificación , Papaver/química
3.
J Pharm Biomed Anal ; 208: 114444, 2022 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-34773838

RESUMEN

Like drug products, Active Pharmaceutical Ingredients (APIs) are subject to substandard and falsification issues, which represent a threat to patient health. In order to monitor the quality of drug substances and prevent the use of non-compliant APIs, Official Medicine Control Laboratories work together in a European network developing coordinated strategies and programmes. The API working group proposed a market surveillance study on omeprazole and omeprazole magnesium with the objectives of controlling the pharmaceutical quality of samples, checking compliance with the monographs of the European Pharmacopoeia, and collecting analytical fingerprints that could be further used to differentiate manufacturing sources for future authenticity investigations. The study described in this article reports the analysis carried out by 7 European laboratories on 28 samples from 11 manufacturers with 5 analytical techniques (related substances with HPLC, residual solvents with GC-MS, near infrared spectroscopy, proton nuclear magnetic resonance spectroscopy and X-ray powder diffractometry). The large amount of resulting analytical data were centralized and treated with two chemometric methods: Principal Component Analysis and Hierarchical Clustering Analysis. Data were analyzed separately and in combination (data fusion), allowing us to conclude that NMR and XRPD were suitable to differentiate samples originating from 9 out of 11 manufacturers. Analytical fingerprints associated with chemometrics were demonstrated to be a valuable methodology to discriminate manufacturers of omeprazole and omeprazole magnesium APIs and detect future substandard and falsified APIs.


Asunto(s)
Medicamentos Falsificados , Quimiometría , Humanos , Espectroscopía de Resonancia Magnética , Omeprazol , Análisis de Componente Principal
4.
Talanta ; 239: 123123, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34942486

RESUMEN

Through its Active Pharmaceutical Ingredient Working Group (API-WG) the General European Official Medicines Control Laboratory (OMCL) Network (GEON), co-ordinated by the European Directorate for the Quality of Medicines & HealthCare (EDQM), regularly organises market surveillance studies for specific APIs for conformity to their monograph in the European Pharmacopoeia. During the past years some studies were combined with a fingerprint study of the APIs. The idea is to obtain a fingerprint for each manufacturer of the API under investigation, allowing the OMCL network to identify future samples as well as to detect substandard and falsified APIs. This paper reports the results of the latest fingerprint study, organised on sildenafil citrate API samples. Seventy-nine samples from 14 different manufacturers were collected throughout the Network. Fingerprint data was collected through Mid-Infrared spectroscopy, Raman spectroscopy, liquid chromatography for related substances, gas chromatography for residual solvents, X-ray diffraction and Nuclear Magnetic Resonance (NMR) spectroscopy. Chemometrics applied to the collected data showed that all manufacturers could be discriminated based on the data of only three of these tests, i.e. gas chromatography for residual solvents, X-ray diffraction and proton NMR. Suspicious API samples for sildenafil citrate will therefore be analysed in the future with the selected techniques in order to link the sample to a manufacturer or demonstrate the absence of such link. If the sample cannot be attributed to one of the manufacturers, further analysis and research on provenance and identity will be required. Of course, if the suspected sample claims to originate from one of the manufacturers included in the study, analysis can be limited to the test distinguishing this manufacturer.


Asunto(s)
Quimiometría , Cloruro de Polivinilo , Análisis por Conglomerados , Espectroscopía de Resonancia Magnética , Citrato de Sildenafil
5.
J Chromatogr A ; 1282: 38-45, 2013 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-23415138

RESUMEN

Although the knowledge and use of several Salvia species (Salvia officinalis, Salvia fruticosa, and Salvia pomifera) can be dated back to Greek Era and have a long history of culinary and effective medicinal use, still there is a remarkable interest concerning their chemistry and especially the polyphenolic composition. Despite the demand in the food and pharmaceutical industry for methods for fast quality assessment of the herbs and spices, even now there are no official requirements for the minimum content of polyphenols in sage covered by current regulations neither the European Pharmacopoeia monographs nor the ISO 11165 standard. In this work a rapid analytical method for extraction, characterization and quantification of the major polyphenolic constituents in Sage was developed. Various extractions (infusion - IE; ultrasound-assisted extraction - USE and microwave-assisted extraction - MWE) were performed and evaluated for their effectiveness. Along with the optimization of the mass-detector and chromatographic parameters, the applicability of three different reverse C18 stationary phases (extra-density bonded, core-shell technology and monolith column) for polyphenolics characterization was evaluated. A comprehensive overview of the very variable polyphenolic composition of 118 different plant samples of 68 populations of wild growing culinary Salvia species (S. officinalis: 101; S. fruticosa: 15; S. pomifera: 2) collected from South East Europe (SEE) was performed using HPLC-DAD-ESI-MS(n) and more than 50 different compounds were identified and quantified. With this work the knowledge about polyphenols of culinary Sage was expanded thus the possibility for gaining an insight into the chemodiversity of culinary Salvia species in South East Europe was unlocked.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Extractos Vegetales/química , Polifenoles/química , Salvia officinalis/química , Fraccionamiento Químico/métodos , Europa Oriental , Grecia , Polifenoles/análisis , Polifenoles/aislamiento & purificación , Reproducibilidad de los Resultados , Solventes/química , Sonicación , Espectrometría de Masa por Ionización de Electrospray/métodos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA