Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Surg Technol Int ; 37: 427-431, 2020 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-32894518

RESUMEN

INTRODUCTION: Traumatic spinal injury presents the potential for significant morbidity and mortality, and posterior fixation and fusion with bone grafts is a primary treatment for many vertebral fractures. While iliac crest autograft (ICBG) is considered the gold standard in bone grafting, this carries risks of morbidity at the donor site as well as prolonging surgery time. Bone graft substitutes (BGS) may provide a viable alternative to autograft but there is little published data concerning its use in trauma. Therefore, we conducted this retrospective review to evaluate the outcomes for fusion among patients who have received a BGS during posterolateral fusion (PLF) for vertebral trauma. MATERIALS AND METHODS: This was a retrospective, consecutive patient cohort. Over a six-month period, we identified 27 patients who had undergone PLF for spine trauma and in whom a BGS comprised of bovine-derived apatite was used. All patients had followed the standard of care. The postoperative plain film radiographs at three, six, 12, and (optionally) 24 months were independently assessed by an orthopedic surgeon who was not affiliated with the hospital. RESULTS: We documented a radiographically observed fusion rate of 85% and a successful treatment rate of 92%. There were no adverse events related to the BGS. Patients who received a BGS with ICBG spent significantly longer in surgery than other patients. There were no adverse events related to the BGS. CONCLUSIONS: The spondylodesis rate following surgery in which the BGS was used in PLF, whether alone, mixed with local bone, or mixed with ICBG is comparable to the rates that have been reported for iliac crest autograft in these indications. The data indicates that the BGS provides a useful adjunct in PLF for the treatment of traumatic spine vertebral injuries. The use of BGS also allows for shorter time in surgery, which may reduce resource utilization and thus lower the total costs of the procedure. CLINICAL RELEVANCE: Posterolateral fusion can be obtained with the use of a bio-derived BGS while reducing the time in surgery by avoiding the second procedure necessary to harvest ICBG. This may be advantageous in cases where the surgeon wishes to minimize operating time or when the availability of autograft is limited.


Asunto(s)
Trasplante Óseo , Animales , Apatitas , Bovinos , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Estudios Retrospectivos , Fusión Vertebral , Resultado del Tratamiento
2.
Int Orthop ; 43(3): 697-703, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-29785590

RESUMEN

PURPOSE: The purpose of this study is to analyze the results using the USS fracture MIS system (DePuy Synthes) to treat instable pelvic ring fractures. As its outstanding feature, it is the only Schanz screw and rod system at present that combines angular stability, perforation/fenestration of the screws for cement-augmentation, a variable screw length, and a large screw diameter. MATERIALS AND METHODS: Retrospective investigation of 134 pelvic ring fractures treated in 2012-2013. Twenty-five patients obtained the abovementioned implant. Besides baseline characteristics of the included patients and the surgical procedure, a clinical/radiological follow-up of six months was analyzed. RESULTS: Dividing the collective into two groups, I high-energy trauma and II fragility fracture of the pelvis, the following results were recorded: group I: ten patients, six male, age 48.4 ± 19.7 years. Mean ISS 41 ± 22.5, fracture classification: AO/OTA type 61 B1/C1/C3 = 1/5/4. Operative treatment: three transiliac internal fixator, seven iliolumbar fixation, one implant was cement-augmented. Group II: 15 patients, 14 female, age 77.5 ± 10.1 years. Fracture classification according to Rommens: FFPII/III/IV = 6/1/8. Operative treatment: eight transiliac internal fixator, seven iliolumbar fixation, 14 implants were cement-augmented. Overall surgical side complications: 16%. Radiological examination: correct positioning of all ilium screws. Follow-up after six month (16 patients): all showed fracture consolidation. One ilium screw was broken close to the connecting clamp. CONCLUSION: The investigated Schanz screw rod system is a suitable implant to broaden the established procedures to stabilize dorsal pelvic ring fractures. TRIAL REGISTRATION: The study is registered at the Clinical Trial Registry University of Regensburg (Number Z-2017-0878-3).


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Huesos Pélvicos/lesiones , Adulto , Anciano , Cementos para Huesos , Clavos Ortopédicos , Tornillos Óseos , Femenino , Fijación Interna de Fracturas/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Sistema de Registros , Estudios Retrospectivos
3.
Arch Orthop Trauma Surg ; 139(7): 943-949, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30847622

RESUMEN

INTRODUCTION: Medial parapatellar or transpatellar ligament approaches are commonly used for nail osteosynthesis in tibia shaft fractures. The lower leg is normally in a hanging position to allow guide wire insertion and reaming of the tibia. However, this position complicates fracture reduction and retention, as well as image intensification throughout the procedure. A lateral parapatellar approach with the lower leg in a semi-extended, horizontal position has been previously described for proximal tibial fracture fixation. The purpose of the presented study was to share the lateral parapatellar approach technique used in our institution and to analyse its feasibility for tibia shaft fracture fixation when compared to a medial parapatellar and transpatellar incision technique. MATERIALS AND METHODS: All patients with tibial shaft fractures treated at our institution between 2009 and 2012 by intramedullary nailing through either a transpatellar, a medial parapatellar or a lateral parapatellar approach were reviewed. Demographics, injury pattern and the operative procedure, especially operation and fluoroscopy time, were analysed. RESULTS: 73 patients were enrolled into the study. Twenty-six patients were treated by use of a lateral parapatellar approach, whilst a transpatellar or a medial parapatellar approach was chosen in 29 and 18 cases, respectively. Patients' characteristics were similar regarding gender and body mass index. When compared to the transpatellar (126 ± 30 min) or the medial parapatellar approach (105 ± 29 min), surgical time was significantly shorter in the lateral parapatellar approach group (96 ± 29 min). Likewise, shorter image intensifier time was documented when a lateral parapatellar approach was chosen (211 ± 189 s) compared to the transpatellar (347 ± 204 s) or the medial parapatellar approach (241 ± 222 s). CONCLUSION: The extra-articular semi-extended tibial nailing technique using a lateral parapatellar approach was associated with a significant decrease in time of surgery, while fluoroscopy time was shorter but not significantly different between the three groups.


Asunto(s)
Fluoroscopía/métodos , Fijación Intramedular de Fracturas , Tempo Operativo , Ligamento Rotuliano , Tibia , Fracturas de la Tibia , Adulto , Clavos Ortopédicos , Femenino , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/métodos , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Ligamento Rotuliano/diagnóstico por imagen , Ligamento Rotuliano/cirugía , Tibia/diagnóstico por imagen , Tibia/lesiones , Tibia/cirugía , Fracturas de la Tibia/diagnóstico , Fracturas de la Tibia/cirugía
4.
World J Surg ; 42(12): 3918-3926, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29959488

RESUMEN

BACKGROUND: Conservative treatment of even severe thoracic trauma including flail chest was traditionally the standard of care. Recently, we reported possible benefits of surgical chest wall stabilization in accordance with other groups. The aim of this study was to critically review our indications and results of internal fixation of rib fractures in the long-term course. METHODS: We retrospectively analyzed the data of a consecutive series of patients with internal rib fracture fixation at our institution from 8/2009 until 12/2014, and we retrospectively studied the late outcome through clinical examination or personal interview. RESULTS: From 1398 patients, 235 sustained a severe thoracic trauma (AIS ≥3). In 23 of these patients, 88 internal rib fixations were performed using the MatrixRIB® system. The median age of these operated patients was 56 years [interquartile range (IQR) 49-63] with a median ISS of 21 [IQR 16-29]. From 18 local resident patients, follow-up was obtained after an average time period of 27.6 (12-68) months. Most of these patients were free of pain and had no limitations in their daily routine. Out of all implants, 5 splint tips perforated the ribs in the postoperative course, but all patients remained clinically asymptomatic. Plate osteosynthesis showed no loss of reduction in the postoperative course. No cases of hardware prominence, wound infection or non-union occurred. CONCLUSIONS: In our carefully selected thoracic trauma patients, locked plate rib fixation seemed to be safe and beneficial not only in the early posttraumatic course, but also after months and years, patients remain asymptomatic and complete recovery as a rule. Trial registration number KEK BASEC Nr. 2016-01679.


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas de las Costillas/cirugía , Traumatismos Torácicos/cirugía , Pared Torácica/lesiones , Heridas no Penetrantes/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
5.
Arch Orthop Trauma Surg ; 137(5): 663-671, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28374092

RESUMEN

INTRODUCTION: Anatomic fit of intramedullary nails was suggested by previous studies to improve significantly when the nail radius of curvature (ROC) is closer to the average femoral anatomy. However, no attempt has been made to investigate the impact of different ROC designs on the nail insertion process. Therefore, this biomechanical study quantitatively compared the ease of insertion between femoral intramedullary nails with a 1.0-m and a 1.5-m bow radius. MATERIALS AND METHODS: Long TFN-ADVANCED™ (TFNA, 1.0 m ROC) and Proximal Femoral Nail Antirotation nails (PFNA, 1.5 m ROC) were implanted pairwise into seven paired cadaver femora. All bones were reamed 1.5 mm larger than the nail diameter. Using a material testing machine, intramedullary nailing was then performed stepwise with 20-mm steps and a 10-mm/s insertion rate, and force was measured. The nail deformation caused by the insertion was assessed through 3D computer models built from pre- and post-nailing CT scans. The ease of insertion between TFNA and PFNA nails was quantified in terms of insertion force, insertion energy and nail deformation. RESULTS: There was no significant difference in the peak force generated during nailing between TFNA and PFNA nails (P = 0.731). However, the force measured at the end of insertion (P = 0.002) was significantly smaller in TFNA nails compared to PFNA nails. After implantation, TFNA nails showed significantly smaller deformation when compared to PFNA nails (P = 0.005, both ends aligned). Furthermore, less energy was required to insert TFNA nails; however, the difference was not significant (P = 0.25). CONCLUSIONS: Compared to PFNA nails, a significant decrease in insertion force and nail deformation was found at the end of insertion for TFNA nails. Results suggest that TFNA having a 1.0-m ROC is easier to insert for the set of femora used in this study compared to PFNA with a 1.5-m ROC.


Asunto(s)
Clavos Ortopédicos , Fracturas del Fémur/cirugía , Fémur , Fijación Intramedular de Fracturas , Fenómenos Biomecánicos , Clavos Ortopédicos/efectos adversos , Clavos Ortopédicos/clasificación , Cadáver , Falla de Equipo , Fémur/diagnóstico por imagen , Fémur/cirugía , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Humanos , Ensayo de Materiales , Modelos Anatómicos , Tomografía Computarizada por Rayos X/métodos
6.
BMC Musculoskelet Disord ; 17: 119, 2016 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-26964742

RESUMEN

BACKGROUND: Operative treatment is the standard for severely displaced proximal humerus fractures, but functional impairment can persist. Retaining of the implant can be a reason and in other fracture situations has proved to ameliorate patient satisfaction. The aim of this study was to analyse the functional outcome after locking plate removal in proximal humerus fractures. METHODS: In a two-year period, all symptomatic patients with plate osteosynthesis for proximal humerus fracture and hardware removal were retrospectively evaluated clinically and radiologically pre- and post-implant removal. Evaluation included Constant score, height of plate position and possible impingement, as well as intraoperative complications. RESULTS: Twenty patients met the inclusion criteria. The mean age was 56 ± 12 years. The plates were placed 6.9 ± 3 mm distal to the greater tubercle. The operation was performed in 35 ± 10 min and no intraoperative complications were reported. The Constant score improved significantly after implant removal from 71 to 76 (p = 0.008). CONCLUSION: Symptomatic patients after locked plate osteosynthesis for proximal humerus fractures showed statistically significant improvement of the Constant score after implant removal.


Asunto(s)
Placas Óseas , Remoción de Dispositivos , Fijación Interna de Fracturas/instrumentación , Complicaciones Posoperatorias/cirugía , Fracturas del Hombro/cirugía , Adulto , Anciano , Placas Óseas/efectos adversos , Remoción de Dispositivos/efectos adversos , Procedimientos Quirúrgicos Electivos , Femenino , Fijación Interna de Fracturas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Reoperación , Estudios Retrospectivos , Fracturas del Hombro/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento
7.
Arch Orthop Trauma Surg ; 136(2): 277-84, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26739137

RESUMEN

INTRODUCTION: Uncemented short, curved femoral stems may help save proximal bone stock during total hip arthroplasty (THA) and facilitate insertion in minimal invasive surgery. The aim of this 2 year, prospective, single-center study was to examine the stability and migration of the Fitmore (®) stem in THA using model-based radiostereometric analysis (RSA), and thus predict the implant's long-term survival. In addition, we evaluated the stem's clinical performance using standard clinical measures. PATIENTS AND METHODS: We conducted a prospective cohort study of 34 THA patients who received the short Fitmore Hip Stem (Zimmer, Winterthur, Switzerland). At 3, 6, 12 and 24 months postoperatively, the patients underwent clinical evaluation and radiostereometric analysis (RSA) to measure stem migration. RESULTS: RSA analysis revealed a mean subsidence of -0.39 mm (95 % CI -0.60 to -0.18) at 3 months with no further migration after 2 years. Mean internal rotation along the longitudinal axis was 1.09° (95 % CI 0.52-1.66) at 2 years, versus 0.85° (95 % CI 0.44-1.26) at 3 months. The Harris hip score improved from 60 (range 30-80) preoperatively to 99 (range 83-100) after 2 years. Three patients underwent revision due to deep infection, non-specific thigh pain and aseptic loosening in one case. CONCLUSION: We conclude that the Fitmore Hip Stem stabilizes after 3 months and achieves good short-term clinical results in most cases.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Análisis Radioestereométrico , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación del Resultado de la Atención al Paciente , Diseño de Prótesis , Adulto Joven
8.
J Orthop Res ; 42(7): 1463-1472, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38341759

RESUMEN

Elderly patients often have more than one disease that affects walking behavior. An objective tool to identify which disease is the main cause of functional limitations may aid clinical decision making. Therefore, we investigated whether gait patterns could be used to identify degenerative diseases using machine learning. Data were extracted from a clinical database that included sagittal joint angles and spatiotemporal parameters measured using seven inertial sensors, and anthropometric data of patients with unilateral knee or hip osteoarthritis, lumbar or cervical spinal stenosis, and healthy controls. Various classification models were explored using the MATLAB Classification Learner app, and the optimizable Support Vector Machine was chosen as the best performing model. The accuracy of discrimination between healthy and pathologic gait was 82.3%, indicating that it is possible to distinguish pathological from healthy gait. The accuracy of discrimination between the different degenerative diseases was 51.4%, indicating the similarities in gait patterns between diseases need to be further explored. Overall, the differences between pathologic and healthy gait are distinct enough to classify using a classical machine learning model; however, routinely recorded gait characteristics and anthropometric data are not sufficient for successful discrimination of the degenerative diseases.


Asunto(s)
Marcha , Aprendizaje Automático , Humanos , Proyectos Piloto , Anciano , Masculino , Femenino , Marcha/fisiología , Persona de Mediana Edad , Máquina de Vectores de Soporte , Osteoartritis de la Cadera/fisiopatología , Análisis de la Marcha/métodos , Osteoartritis de la Rodilla/fisiopatología , Estudios de Casos y Controles , Anciano de 80 o más Años
9.
Clin Biomech (Bristol, Avon) ; 103: 105906, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36806999

RESUMEN

BACKGROUND: The impact of the nail radius of curvature, as one of the most important design features in modern femoral nails on the ease of nail removal, remains unknown. Therefore, the aim of this study was to investigate force, energy, and nail deformation of different nail designs. METHODS: Nail insertion and extraction was performed on six pairs of fresh-frozen human cadaveric femora on a material testing machine with two different nail systems - Trochanter femoral nail ADVANCED™ Nailing System with a radius of curvature of 1.0 m and Proximal Femoral Nail Antirotation System with a radius of curvature of 1.5 m. Deformation was measured after insertion (plastic and elastic deformations) and extraction (plastic deformations). FINDINGS: The peak force during nail removal was significantly lower in the first group (274.5 ± 130.4 N) compared to the second group (695.2 ± 158.8 N, p = 0.001). Plastic deformation was observed in all implants, being significantly larger in the Proximal Femoral Nail Antirotation System (p = 0.027). There was a strong positive correlation between the first peak force during nail removal and nail insertion (r = 0.802, p = 0.002) as well as between extracting energy and insertion energy (r = 0.943, p < 0.001). INTERPRETATION: The results from this study showed that a radius of curvature of 1.0 m is easier to remove from the set of cadaver femora. Furthermore, our findings support the idea of further reducing the nail radius of curvature below 1.0 m in order to more closely match the anatomy of populations with strong-bowed femora.


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Fracturas del Fémur/cirugía , Clavos Ortopédicos , Fémur/cirugía , Fijación Intramedular de Fracturas/métodos , Extremidad Inferior , Fenómenos Biomecánicos
10.
Arch Orthop Trauma Surg ; 132(2): 227-31, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21997400

RESUMEN

INTRODUCTION: Dislocation type proximal tibia fractures are associated with the major soft tissue injuries. The main purpose of this study was to analyze the incidence of compartment syndrome (CS) in proximal tibia fractures in relation to the fracture type, i.e., dislocation versus non-dislocation type. We further analyzed CS within the non-dislocation type injuries, initial treatment modality as well as infection rate relative to the treatment policies (one- or two-staged procedures). PATIENTS AND METHODS: Over an 8.5-year period, prospectively, acquired data of 356 proximal tibia fractures were evaluated. All fractures were classified either according to the AO/OTA or to the Moore (fracture dislocation type) classification system respectively. The appearance of CS in dislocation and non-dislocation type injuries as well as treatment modality, i.e., one- or two-staged procedures was analyzed. RESULTS: 307 (86%) fractures were classified as non-dislocation type and 49 (14%) as fracture dislocation type injuries. Overall 31 (8.7%) CS occurred. All were diagnosed and treated within the initial surgical management. CS was equally distributed in non-dislocation type fractures (24/307) and Moore type fractures (7/49) (Chi-square test, p = 0.4). But a significant difference in the non-dislocation type injuries was observed between AO/OTA B-type (0/166) and non-B type fractures (24/117) (Chi-square test, p < 0.001). 104 fractures were treated in a two-staged procedure with definitive reconstruction after an average of 6.0 days. Initial postoperative surgical site infection remained very low with 0.5%, and did not seem to be related to operative treatment variables including single-stage versus two-stage reconstruction, temporary external fixation and/or compartment fasciotomies. CONCLUSION: The incidence for CS did not differ between the dislocation and non-dislocation type group, but a significant difference was found comparing the incidence for CS only in the non-dislocation type group.


Asunto(s)
Síndromes Compartimentales/etiología , Luxaciones Articulares/complicaciones , Articulación de la Rodilla , Fracturas de la Tibia/complicaciones , Síndromes Compartimentales/epidemiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Infección de la Herida Quirúrgica/epidemiología , Fracturas de la Tibia/cirugía
11.
J Orthop Res ; 39(4): 761-770, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33098585

RESUMEN

Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsional loading applied through the S1 vertebral body to promote turn-out of the implants. Interfragmentary movements were captured via optical motion tracking. Screw motions were evaluated by means of triggered anteroposterior X-rays. Interfragmentary movements and implant motions were significantly higher for SI screw fixation compared to both transsacral and screw-in-screw fixations. In addition, transsacral screw and screw-in-screw fixations revealed similar construct stability. Moreover, screw-in-screw fixation successfully prevented turn-out of the implant that remained during testing at 0° rotation for all specimens. From biomechanical perspective, fragility sacrum fracture fixation with the new screw-in-screw implant prototype provides higher stability than an SI screw, being able to successfully prevent turn-out. Moreover, it combines the higher stability of transsacral screw fixation with the less risky operational procedure of SI screw fixation and can be considered as their alternative treatment option.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Sacro/cirugía , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Humanos , Osteotomía/instrumentación , Osteotomía/métodos , Pelvis/cirugía , Radiografía , Fracturas de la Columna Vertebral/cirugía , Estrés Mecánico , Rayos X
12.
J Biomech ; 115: 110109, 2021 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-33257010

RESUMEN

Intramedullary femoral nails provide an ideal mechanical axis for periprosthetic fracture fixation. Slotted nails allow a connection to a total knee arthroplasty (TKA) stem. This study aims to compare implant and construct stiffness, interfragmentary movement and cycles to failure between an antegrade slotted femoral nail construct docked to a TKA stem and a distal femoral locking plate in a human periprosthetic femoral fracture model. In eight pairs of fresh-frozen human femora with stalked TKA, a 10 mm transverse osteotomy gap was set simulating a Rorabeck type II, Su type I fracture. The femora were pairwise instrumented with either an antegrade slotted nail coupled to the prosthesis stem, or a locking plate. Cyclic testing with a progressively increasing physiologic loading profile was performed at 2 Hz until catastrophic construct failure. Relative movement at the osteotomy site was monitored by means of optical motion tracking. In addition, four-point bending implant stiffness, torsional implant stiffness and frictional fit of the stem-nail connection were investigated via separate non-destructive tests. Intramedullary nails exhibited significantly higher four-point bending and significantly lower torsional implant stiffness than plates, P < 0.01. Increasing difference between nail and stem diameters decreased frictional fit at the stem-nail junction. Nail constructs provided significantly higher initial axial bending stiffness and cycles to failure (200 ± 83 N/mm; 16'871 ± 5'227) compared to plate constructs (93 ± 35 N/mm; 7'562 ± 1'064), P = 0.01. Relative axial translation at osteotomy level after 2'500 cycles was significantly smaller for nail fixation (0.14 ± 0.11 mm) compared with plate fixation (0.99 ± 0.20 mm), P < 0.01. From a biomechanical perspective, the docking nail concept offers higher initial and secondary stability under dynamic axial loading versus plating in TKA periprosthetic fracture fixation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fracturas del Fémur , Fijación Intramedular de Fracturas , Fracturas Periprotésicas , Fenómenos Biomecánicos , Placas Óseas , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas , Humanos , Fracturas Periprotésicas/cirugía
13.
Orthop Clin North Am ; 52(1): 1-13, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33222980

RESUMEN

Skills training is important in an arthroplasty curriculum and can focus either on "part tasks" or on full procedures. The most commonly used simulations in orthopedics including arthroplasty are anatomic specimens, dry bone models, and virtual or other technology-enhanced systems. A course curriculum planning committee must identify the gaps to address, define what learners need to be able to do, and select the most appropriate simulation modality and assessment for delivery. Each simulation must have a clear structure with learning objectives, steps, and take-home messages. Feedback from learners and faculty must be integrated to improve processes and models for future learning.


Asunto(s)
Artroplastia de Reemplazo de Cadera/educación , Artroplastia de Reemplazo de Rodilla/educación , Competencia Clínica , Curriculum , Ortopedia/educación , Cadáver , Simulación por Computador , Humanos , Modelos Anatómicos
14.
Hip Int ; 30(2): 152-159, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31010329

RESUMEN

BACKGROUND: Although reported results on short stems sound very promising, the occurrence of distal femoral cortical hypertrophy is often observed. The aim of the present study was to report 5-year survival data of a commercially available trochanter sparing short stem and investigate the clinical impact of distal femoral cortical hypertrophy on the outcome. METHODS: 123 total hip arthroplasties were performed on 120 patients from April 2008 to May 2010 (mean age 62, range 29-89 years; 71 hips from male patients, 58%). Clinical and radiological data were collected preoperative, at 6 weeks, 1, 2, 3, and 5 years postoperative to assess the outcome. Radiographs taken immediately postoperative as well as 1 and 5 years postoperative were used to identify and assess cortical hypertrophy. RESULTS: 1 stem had to be revised due to aseptic loosening, resulting in a Kaplan-Meier survival analysis with endpoint for stem revision of 99.2% (95% Confidence Interval 94.1-99.9) at 5 years. 96 radiological and 95 clinical follow-ups were analysed 5 years postoperative. 68 (71%) hips showed distal femoral cortical hypertrophy after 5 years. The average Harris Hip Score and Oxford Hip Score improved 33 (standard deviation (SD) 15.1, range 2-70), 18 (SD 12.1, range -10-43) points, respectively. Overall 16% of the patients reported thigh pain, unrelated to the presence of cortical hypertrophy. DISCUSSION: This short stem shows an excellent 5-year survival rate and good clinical outcome despite a high incidence of cortical hypertrophy. However, the question of the mechanism of load transfer arises.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Complicaciones Posoperatorias/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Hipertrofia/diagnóstico , Hipertrofia/etiología , Incidencia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Tasa de Supervivencia/tendencias , Suiza/epidemiología , Factores de Tiempo , Resultado del Tratamiento
15.
Shoulder Elbow ; 11(3): 225-232, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31210795

RESUMEN

BACKGROUND: Cerclage wire is the current standard for circumferential bone fixation. Advances in technology have improved modern sutures, allowing for expanded utility and broader application. The present study compared the strength and durability of cerclage fixation between modern suture materials and monofilament wire. METHODS: The Surgeon's Knot, the Nice Knot and the Modified Nice Knot, were each tied using three separate suture materials: no. 2 FiberWire (Arthrex, Naples, FL, USA), no. 2 Ultrabraid (Smith & Nephew, Andover, MA, USA) and no. 5 Ethibond (Johnson & Johnson, Somerville, NJ, USA). These sutures were compared with monofilament wire. Sutures were secured around a fixed diameter using three additional half hitches, whereas a 1.2-mm (18 gauge) stainless steel monofilament wire was used for comparison. One fellow and one orthopaedic surgery resident each tied five trials with every knot/material combination. Samples were subjected to cyclic loading and quasi-static load testing. Respectively, cyclic displacement over time and load to failure were analyzed. Clinical failure (3 mm of cyclic displacement) and absolute failure (opening of the knot or material failure) were the outcomes of interest. RESULTS: During cyclic loading, Ethibond displaced significantly less over time compared to monofilament wire (p < 0.003), whereas FiberWire showed no significant difference. Ultrabraid also behaved similar to wire, except displacing significantly more than wire only with the Surgeon's Knot (p = 0.02). During load to failure, Ethibond and FiberWire failed at significantly greater loads than monofilament wire (p < 0.001), whereas Ultrabraid performed similar to wire. Knot types did not appear to impact the results. CONCLUSIONS: High-performance sutures achieve superior results in biomechanical testing under cyclic and quasi-static load compared to monofilament wire, suggesting that they provide an alternative to wire for cerclage fixation with select clinical application. Biomechanical security of suture cerclage is dependent on suture material, although it is not altered significantly by choice of knot. An ex-vivo study with clinical application would further reinforce whether suture cerclage offers a valid alternative to wire cerclage.

16.
Langenbecks Arch Surg ; 393(1): 45-7, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17690904

RESUMEN

BACKGROUND: Gastric necrosis after Nissen fundoplication is a rare and life-threatening complication described in paediatric surgery and in some experimental models. Prompt diagnosis and appropriate therapy of acute gastric dilatation is mandatory to avoid potentially fatal gastric necrosis. CASE REPORT: This case report is the first one to describe a gastric necrosis in an adult as a late and very severe complication after Nissen fundoplication. Gastric dilatation and subsequent necrosis occurred 14 years after Nissen fundoplication because of small bowel obstruction based on adhesions. CONCLUSION: Early diagnosis and treatment of gastric dilatation after Nissen fundoplication are essential to prevent from severe secondary complications but can be difficult to establish because of atypical symptoms.


Asunto(s)
Fundoplicación/efectos adversos , Dilatación Gástrica/diagnóstico , Hernia Hiatal/cirugía , Complicaciones Posoperatorias/diagnóstico , Estómago/patología , Anciano de 80 o más Años , Anastomosis en-Y de Roux , Anastomosis Quirúrgica , Esófago/cirugía , Femenino , Estudios de Seguimiento , Gastrectomía , Dilatación Gástrica/cirugía , Humanos , Obstrucción Intestinal/complicaciones , Obstrucción Intestinal/diagnóstico , Obstrucción Intestinal/cirugía , Enfermedades del Yeyuno/complicaciones , Enfermedades del Yeyuno/diagnóstico , Enfermedades del Yeyuno/cirugía , Yeyuno/cirugía , Necrosis , Peritonitis/diagnóstico , Peritonitis/cirugía , Complicaciones Posoperatorias/cirugía , Adherencias Tisulares/complicaciones , Adherencias Tisulares/diagnóstico , Adherencias Tisulares/cirugía
17.
Injury ; 49 Suppl 1: S91-S95, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29929702

RESUMEN

Routine implant removal is frequently performed although evidence-based guidelines are lacking. But routinely planned implant removal has significant economic implications and shows considerable complication rates. In general, clinical outcome seems to improve but pain relief after operation is often unpredictable. Even in patients reporting implant-related pain, implant removal does not guarantee relief and may be associated with further complications. The intra- and postoperative complication rate remains very high. Implant removal demonstrates a significant learning curve and unsupervised junior surgeons tend to cause more complications. The need for implant removal may be questioned. Even with the implant in place, contact activities can be resumed. However, a new adequate trauma can create a new fracture independently if there is an implant in-situ or not. It is important to understand the complications and outcomes to be expected with hardware removal to carefully evaluate its indication.


Asunto(s)
Placas Óseas/efectos adversos , Remoción de Dispositivos/métodos , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Complicaciones Posoperatorias/cirugía , Prótesis e Implantes/efectos adversos , Toma de Decisiones Clínicas , Fijación Interna de Fracturas/efectos adversos , Humanos , Medición de Riesgo
18.
Injury ; 49 Suppl 1: S83-S90, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29929701

RESUMEN

Fracture-related infection (FRI) is one of the most challenging complications in orthopaedic trauma surgery. It has severe consequences for patients and an important socio-economic impact. FRI has distinct properties and needs to be addressed interdisciplinary. Since criteria for the diagnosis of FRI are not standardized, an expert panel recently proposed a definition for FRI. In this review the current diagnostic modalities and an interdisciplinary diagnostic algorithm based on this recently published definition, are presented and future diagnostic techniques discussed. Since to date, there is no single universal diagnostic test available that gives the clinician the definitive diagnosis of FRI, it is mandatory to follow a standardized diagnostic algorithm to correctly diagnose FRI.


Asunto(s)
Fracturas Óseas/complicaciones , Ortopedia , Osteomielitis/diagnóstico , Infección de la Herida Quirúrgica/diagnóstico , Algoritmos , Lista de Verificación , Consenso , Fracturas Óseas/microbiología , Guías como Asunto , Humanos , Osteomielitis/etiología , Osteomielitis/microbiología , Infección de la Herida Quirúrgica/microbiología
19.
J Orthop Res ; 36(6): 1624-1629, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29106756

RESUMEN

With increasing life expectancy, fragility fractures of the pelvic ring are seen more frequently. Although their osteosynthesis can be very challenging, specific biomechanical studies for investigation of the fixation stability are still lacking. The aim of this study was to biomechanically evaluate four different fixation methods for sacrum Denis type II fractures in osteoporotic bone. Unstable Denis type II vertical sacrum fractures were created in 16 human pelves. Their osteosynthesis was performed with one sacro-iliac screw, posterior sacral plating, triangular fixation, or spino-pelvic fixation. For that purpose, each pelvis was randomly assigned to two paired groups for treatment with either SI-screw/posterior sacral plating or triangular fixation/spino-pelvic fixation. Each hemi-pelvis was cyclically tested under progressively increasing axial compression. Relative interfragmentary movements were investigated via optical motion tracking analysis. Axial stiffness of triangular fixation was significantly higher versus posterior sacral plating and spino-pelvic fixation (p ≤ 0.022), but not significantly different in comparison to SI-screw fixation (p = 0.337). Cycles to 2, 3, 5, and 8 mm fracture displacement, as well as to 3°, 5°, and 8° gap angle at the fracture site were significantly higher for triangular fixation compared to all other groups (p ≤ 0.041). Main failure mode for all osteosynthesis techniques was screw cutting through the bone, leading loss of fixation stability. From a biomechanical point of view, triangular fixation in sacrum Denis type II fractures demonstrated less interfragmentary movements and should be considered in unstable fragility fractures of the sacrum. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1624-1629, 2018.


Asunto(s)
Densidad Ósea , Fijación Interna de Fracturas/métodos , Sacro/lesiones , Fracturas de la Columna Vertebral/cirugía , Fenómenos Biomecánicos , Tornillos Óseos , Femenino , Humanos , Masculino , Sacro/fisiología , Sacro/cirugía
20.
J Bone Oncol ; 10: 49-56, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29577024

RESUMEN

BACKGROUND: Bone metastases and lytic lesions due to multiple myeloma are common in advanced cancer and can lead to debilitating complications (skeletal-related events [SREs]), including requirement for radiation to bone. Despite the high frequency of radiation to bone in patients with metastatic bone disease, our knowledge of associated healthcare resource utilization (HRU) is limited. METHODS: This retrospective study estimated HRU following radiation to bone in Austria, the Czech Republic, Finland, Greece, Poland, Portugal, Sweden and Switzerland. Eligible patients were ≥ 20 years old, had bone metastases secondary to breast, lung or prostate cancer, or bone lesions associated with multiple myeloma, and had received radiation to bone between 1 July 2004 and 1 July 2009. HRU data were extracted from hospital patient charts from 3.5 months before the index SRE (radiation to bone preceded by a SRE-free period of ≥ 6.5 months) until 3 months after the last SRE that the patient experienced during the study period. RESULTS: In total, 482 patients were included. The number of inpatient stays increased from baseline by a mean of 0.52 (standard deviation [SD] 1.17) stays per radiation to bone event and the duration of stays increased by a mean of 7.8 (SD 14.8) days. Outpatient visits increased by a mean of 4.24 (SD 6.57) visits and procedures by a mean of 8.51 (SD 7.46) procedures. CONCLUSION: HRU increased following radiation to bone across all countries studied. Agents that prevent severe pain and delay the need for radiation have the potential to reduce the burden imposed on healthcare resources and patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA