RESUMEN
AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pronóstico , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugíaRESUMEN
BACKGROUND: Transcatheter mitral valve replacement (TMVR) has emerged as a minimally invasive alternative to mitral valve surgery for patients at high or prohibitive operative risk. Prospective studies reported favourable outcomes in patients with annulus calcification (valve-in-mitral annulus calcification; ViMAC), failed annuloplasty ring (mitral valve-in-ring; MViR), and bioprosthetic mitral valve dysfunction (mitral valve-in-valve; MViV). Multi-slice computed tomography (MSCT)-derived 3D-modelling and simulations may provide complementary anatomical perspectives for TMVR planning. AIMS: We aimed to illustrate the implementation of MSCT-derived modelling and simulations in the workup of TMVR for ViMAC, MViR, and MViV. METHODS: For this retrospective study, we included all consecutive patients screened for TMVR and compared MSCT data, echocardiographic outcomes and clinical outcomes. RESULTS: Sixteen out of 41 patients were treated with TMVR (ViMAC nâ¯= 9, MViR nâ¯= 3, MViV nâ¯= 4). Eleven patients were excluded for inappropriate sizing, 4 for anchoring issues and 10 for an unacceptable risk of left ventricular outflow tract obstruction (LVOTO) based on 3D modelling. There were 3 procedure-related deaths and 1 non-procedure-related cardiovascular death during 30 days of follow-up. LVOTO occurred in 3 ViMAC patients and 1 MViR patient, due to deeper valve implantation than planned in 3 patients, and anterior mitral leaflet displacement with recurrent basal septum thickening in 1 patient. TMVR significantly reduced mitral mean gradients as compared with baseline measurements (median mean gradient 9.5 (9.0-11.5) mmâ¯Hg before TMVR versus 5.0 (4.5-6.0) mmâ¯Hg after TMVR, pâ¯= 0.03). There was no residual mitral regurgitation at 30 days. CONCLUSION: MSCT-derived 3D modelling and simulation provide valuable anatomical insights for TMVR with transcatheter balloon expandable valves in ViMAC, MViR and MViV. Further planning iterations should target the persistent risk for neo-LVOTO.
RESUMEN
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is considered a safe and effective alternative to surgical aortic valve replacement (SAVR) for elderly patients across the operative risk spectrum. In the Netherlands, TAVI is reimbursed only for patients with a high operative risk. Despite this, one fifth of TAVI patients are <â¯75 years of age. We aim to compare patient characteristics and outcomes of TAVI and SAVR patients <â¯75 years. METHODS: This study included all patients <â¯75 years without active endocarditis undergoing TAVI or SAVR for severe aortic stenosis, mixed aortic valve disease or degenerated aortic bioprosthesis between 2015 and 2020 at the Erasmus University Medical Centre. Dutch authority guidelines were used to classify operative risk. RESULTS: TAVI was performed in 292 patients, SAVR in 386 patients. Based on the Dutch risk algorithm, 59.6% of TAVI patients and 19.4% of SAVR patients were at high operative risk. There was no difference in 30-day all-cause mortality between TAVI and SAVR (2.4% vs 0.8%, pâ¯= 0.083). One-year and 5year mortality was higher after TAVI than after SAVR (1-year: 12.5% vs 4.3%, pâ¯< 0.001; 5year: 36.8% vs 12.0%, pâ¯< 0.001). Within risk categories we found no difference between treatment strategies. Independent predictors of mortality were cardiovascular comorbidities (left ventricular ejection fraction <â¯30%, atrial fibrillation, pulmonary hypertension) and the presence of malignancies, liver cirrhosis or immunomodulatory drug use. CONCLUSION: At the Erasmus University Medical Centre, in patients <â¯75 years, TAVI is selected for higher-risk phenotypes and overall has higher long-term mortality than SAVR. We found no evidence for worse outcome within risk categories.
RESUMEN
INTRODUCTION: Delays in the diagnosis and referral of aortic stenosis (AS) during the coronavirus disease 2019 (COVID-19) pandemic may have affected the haemodynamic status of AS patients. We aimed to compare clinical and haemodynamic characteristics of severe AS patients referred for transcatheter aortic valve implantation (TAVI) or balloon aortic valvuloplasty (BAV) before the pandemic versus two subsequent periods. METHODS: This study compared three 1year historical cohorts: a pre-COVID-19 group (PCOV), a 1st-year COVID-19 group (COV-Y1) and a 2nd-year COVID-19 group (COV-Y2). The main parameters were baseline New York Heart Association (NYHA) functional class, left ventricular ejection fraction (LVEF) and left ventricular end-diastolic pressure (LVEDP). Demographics, procedural characteristics and 30-day clinical outcomes were assessed. The transition time between heart team decision and TAVI was examined. Pairwise group comparisons were performed (PCOV vs COV-1Y and COV-1Y vs COV-2Y). RESULTS: A total of 720 patients were included with 266, 249 and 205 patients in the PCOV, COV-Y1 and COV-Y2 groups, respectively. BAV was performed in 28 patients (4%). NYHA class did not differ across the cohorts. Compared to PCOV, LVEF was slightly lower in COV-Y1 (58% (49-60%) vs 57% (45-60%), pâ¯= 0.03); no difference was observed when comparing COV-Y1 and COV-Y2. LVEDP was higher in COV-Y1 than in PCOV (20â¯mmâ¯Hg (16-26â¯mmâ¯Hg) vs 17â¯mmâ¯Hg (13-24â¯mmâ¯Hg), pâ¯= 0.01). No difference was found when comparing LVEDP between COV-Y1 and COV-Y2. Thirty-day mortality did not differ between groups. Transition time was reduced in the COVID era. Duration of hospital stay declined over the study period. CONCLUSIONS: Patients undergoing TAVI during the COVID-19 pandemic had more advanced AS illustrated by lower LVEF and higher LVEDP, but there were no differences in clinical outcome. The TAVI pathway became more efficient.
RESUMEN
Pericardial effusion (PE) after pediatric cardiac surgery is common. Because of the lack of a uniform classification of the presence and severity of PE, we evaluated PE altering clinical management: clinically relevant PE. Risk factors for clinically relevant PE were studied. After cardiac surgery, children were followed until 1 month after surgery. Preoperative variables were studied in the complete cohort. Perioperative and postoperative variables were studied in a case-control manner. Patients with and without clinically relevant PE were matched on age, gender, and diagnosis severity in a 1:1 ratio. Multivariate analysis was conducted using important preoperative variables from the complete cohort combined with perioperative and postoperative variables from the case-control data. 1241 surgical episodes in 1031 patients were included. Clinically relevant PE developed in 136 episodes (11.0%). Multivariate correlation with the outcome was present for age, BSA (adjusted odds ratio: 1.6, 95% CI 0.9-2.8), right-sided heart defect (adjusted odds ratio: 1.3, 95% CI 0.9-1.9), history of previous operation (adjusted odds ratio: 0.5, 95% CI 0.3-0.7), cardiopulmonary bypass use (adjusted odds ratio: 2.1, 95% CI 0.9-4.5), duration of CPAP postoperatively, and an inotropic score (adjusted odds ratio: 1.01, 95% CI 0.998-1.03). In this large patient cohort, 11.0% of postoperative periods of pediatric cardiac surgery were complicated by PE requiring alteration of treatment. Secondly, we newly identified cardiopulmonary bypass use and right-sided heart defects as risk factors for clinically relevant PE and confirmed previously described risk factors: age, CPAP duration, BSA, and inotropic score and a previously described risk reductor: history of previous operation.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Derrame Pericárdico/epidemiología , Complicaciones Posoperatorias/epidemiología , Adolescente , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Cardiopatías Congénitas/cirugía , Humanos , Incidencia , Lactante , Recién Nacido , Masculino , Análisis Multivariante , Derrame Pericárdico/etiología , Complicaciones Posoperatorias/etiología , Medición de Riesgo/métodos , Factores de RiesgoRESUMEN
The demonstrated safety and effectiveness of transcatheter aortic valve implantation (TAVI) among low surgical risk patients opened the road to its application in younger low-risk patients. However, the occurrence of conduction abnormalities and need for permanent pacemaker implantation remains a frequent problem associated with adverse outcomes. The clinical implications may become greater when TAVI shifts towards younger populations, highlighting the need for comprehensive strategies to address this issue. Beyond currently available clinical and electrocardiographic predictors, patient-specific anatomical assessment of the aortic root using multi-sliced CT (MSCT) imaging can refine risk stratification. Moreover, leveraging MSCT data for computational 3D simulations to predict device-anatomy interactions may help guide procedural strategy to mitigate conduction abnormalities. The aims of this review are to summarise the incidence and clinical impact of new left bundle branch block and permanent pacemaker implantation post-TAVI using contemporary transcatheter heart valves; and highlight the value of MSCT data interpretation to improve the management of this complication.
RESUMEN
Moderate aortic stenosis is increasingly recognized as a disease entity with poor prognosis. Diagnosis of moderate aortic stenosis may be complemented by laboratory tests and advanced imaging techniques focused at detecting signs of cardiac damage such as increase of cardiac enzymes (N-terminal pro-B-type Natriuretic Peptide, troponin), left ventricular remodeling (hypertrophy, reduced left ventricular ejection fraction), or myocardial fibrosis. Therapy should include guideline-directed optimal medical therapy for heart failure. Patients with signs of cardiac damage may benefit from early intervention, which is the focus of several ongoing randomized controlled trials. As yet, no evidence-based therapy exists to halt the progression of aortic valve calcification.
RESUMEN
Left ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography-derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation (ASA) can mitigate neo-LVOTO risk. We report a case of sequential ASA of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.
RESUMEN
BACKGROUND: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER. METHODS: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR. A subanalysis of SMR-only patients with the addition of COAPT Risk Score and baseline N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) list was also performed. RESULTS: MITRALITY had the best discriminative ability for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with an area under the curve (AUC) of 0.74 and 0.74, respectively, in a composed group of PMR and SMR. In a SMR-only population, MITRALITY also presented the best AUC for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with values of 0.72 and 0.72, respectively. CONCLUSION: MITRALITY was the best mitral TEER risk model for both 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization in a population of PMR and SMR patients, as well as in SMR patients only. Surgical risk scores, MitraScore, TAPSE/PASP-MitraScore and NT-proBNP alone showed poor predictive values.
Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/cirugía , Hospitalización , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Factores de Riesgo , Resultado del TratamientoRESUMEN
Transcatheter aortic valve (TAV) thrombosis may manifest as subclinical leaflet thrombosis (SLT) and clinical valve thrombosis. SLT is relatively common (10%-20%) after transcatheter aortic valve replacement, but clinical implications are uncertain. Clinical valve thrombosis is rare (1.2%) and associated with bioprosthetic valve failure, neurologic or thromboembolic events, heart failure, and death. Treatment for TAV thrombosis has been understudied. In principle, anticoagulation may prevent TAV thrombosis. Non-vitamin K oral anticoagulants, as compared to antiplatelet therapy, are associated with reduced incidence of SLT, although at the cost of higher bleeding and all-cause mortality risk. We present an overview of existing literature for management of TAV thrombosis and propose a rational treatment algorithm. Vitamin K antagonists or non-vitamin K oral anticoagulants are the cornerstone of antithrombotic treatment. In therapy-resistant or clinically unstable patients, ultraslow, low-dose infusion of thrombolytics seems effective and safe and may be preferred over redo-transcatheter aortic valve replacement or explant surgery.
Asunto(s)
Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Trombosis/prevención & control , Trombosis/etiología , Anticoagulantes/uso terapéutico , Anticoagulantes/administración & dosificación , Fibrinolíticos/uso terapéutico , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversosRESUMEN
Transcatheter aortic valve replacement (TAVR) is preferred therapy for elderly patients with severe aortic stenosis (AS) and increasingly used in younger patient populations with good safety and efficacy outcomes. However, cardiac conduction abnormalities remain a frequent complication after TAVR ranging from relative benign interventriculair conduction delays to prognostically relevant left bundle branch block and complete atrio-ventricular (AV) block requiring permanent pacemaker implantation (PPI). Although clinical, procedural and electrocardiographic factors have been identified as predictors of this complication, there is a need for advanced strategies to control the burden of conduction defects particularly as TAVR shifts towards younger populations. This state of the art review highlights the value of ECG-synchronized computed tomographic angiography (CTA) evaluation of the aortic root to better understand and manage conduction problems post-TAVR. An update on CTA derived anatomic features related to conduction issues is provided and complemented with computational framework modelling. This CTA-derived 3-dimensional anatomical reconstruction tool generates patient-specific TAVR simulations enabling operators to adapt procedural strategy and implantation technique to mitigate conduction abnormality risks.
RESUMEN
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis, but data are limited on younger, low-risk patients. This analysis compares outcomes in low-surgical-risk patients aged <75 years receiving TAVR versus surgery. METHODS: The Evolut Low Risk Trial randomized 1414 low-risk patients to treatment with a supra-annular, self-expanding TAVR or surgery. We compared rates of all-cause mortality or disabling stroke, associated clinical outcomes, and bioprosthetic valve performance at 3 years between TAVR and surgery patients aged <75 years. RESULTS: In patients <75 years, 352 were randomized to TAVR and 351 to surgery. Mean age was 69.1±4.0 years (minimum 51 and maximum 74); Society of Thoracic Surgeons Predicted Risk of Mortality was 1.7±0.6%. At 3 years, all-cause mortality or disabling stroke for TAVR was 5.7% and 8.0% for surgery (P=0.241). Although there was no difference between TAVR and surgery in all-cause mortality, the incidence of disabling stroke was lower with TAVR (0.6%) than surgery (2.9%; P=0.019), while surgery was associated with a lower incidence of pacemaker implantation (7.1%) compared with TAVR (21.0%; P<0.001). Valve reintervention rates (TAVR 1.5%, surgery 1.5%, P=0.962) were low in both groups. Valve performance was significantly better with TAVR than surgery with lower mean aortic gradients (P<0.001) and lower rates of severe prosthesis-patient mismatch (P<0.001). Rates of valve thrombosis and endocarditis were similar between groups. There were no significant differences in rates of residual ≥moderate paravalvular regurgitation. CONCLUSIONS: Low-risk patients <75 years treated with supra-annular, self-expanding TAVR had comparable 3-year all-cause mortality and lower disabling stroke compared with patients treated with surgery. There was significantly better valve performance in patients treated with TAVR. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT02701283.
RESUMEN
BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.
Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Accidente Cerebrovascular Isquémico/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugíaRESUMEN
BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Ecocardiografía de Estrés , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Curva ROC , Función Ventricular Izquierda , Área Bajo la Curva , Volumen Sistólico , HemodinámicaRESUMEN
AIMS: To study sex-specific differences in the amount and distribution of aortic valve calcification (AVC) and to correlate the AVC load with paravalvular leakage (PVL) post-transcatheter aortic valve intervention (TAVI). METHODS AND RESULTS: This registry included 1801 patients undergoing TAVI with a Sapien3 or Evolut valve in two tertiary care institutions. Exclusion criteria encompassed prior aortic valve replacement, suboptimal multidetector computed tomography (MDCT) quality, and suboptimal transthoracic echocardiography images. Calcium content and distribution were derived from MDCT. In this study, the median age was 81.7 (25th-75th percentile 77.5-85.3) and 54% male. Men, compared to women, were significantly younger [81.2 (25th-75th percentile 76.5-84.5) vs. 82.4 (78.2-85.9), P ≤ 0.01] and had a larger annulus area [512 mm2 (25th-75th percentile 463-570) vs. 405 mm2 (365-454), P < 0.01] and higher Agatston score [2567 (25th-75th percentile 1657-3913) vs. 1615 (25th-75th percentile 905-2484), P < 0.01]. In total, 1104 patients (61%) had none-trace PVL, 648 (36%) mild PVL, and 49 (3%) moderate PVL post-TAVI. There was no difference in the occurrence of moderate PVL between men and women (3% vs. 3%, P = 0.63). Cut-off values for the Agatston score as predictor for moderate PVL based on the receiver-operating characteristic curve were 4070 (sensitivity 0.73, specificity 0.79) for men and 2341 (sensitivity 0.74, specificity 0.73) for women. CONCLUSION: AVC is a strong predictor for moderate PVL post-TAVI. Although the AVC load in men is higher compared to women, there is no difference in the incidence of moderate PVL. Sex-specific Agatston score cut-offs to predict moderate PVL were almost double as high in men vs. women.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Tomografía Computarizada Multidetector/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Estudios RetrospectivosRESUMEN
Photon-counting detector CT (PCD CT) has increasingly garnered interest in cardiothoracic imaging due to its high spatial resolution and ability to perform spectral imaging. CT plays an important role in the planning and postprocedural assessment of transcatheter aortic valve replacement (TAVR). Limitations of current CT technology resulting in blooming and metal artifacts may be addressed with PCD CT. This case series demonstrates the potential advantages of PCD CT in patients prior to and post-TAVR. In TAVR planning, PCD CT allowed for a detailed depiction of the aortic valve, aortic root, coronary arteries, and potential vascular access routes. The high-spatial-resolution reconstructions enabled assessment of hypoattenuating leaflet thickening and periprosthetic leakage for prosthetic valves. This study shows promising initial results, but further research is needed to determine the clinical impact of PCD CT in patients prior to and post-TAVR. Keywords: Transcatheter Aortic Valve Replacement, Cardiac, Coronary Arteries, Heart, Valves, Photon-counting Detector CT © RSNA, 2023 An earlier incorrect version appeared online. This article was corrected on October 27, 2023.
RESUMEN
Sex-specific thresholds of aortic valve calcification (AVC) correlate with aortic stenosis (AS) and may complement echocardiography to determine AS severity. Importantly, current guideline-recommended thresholds of AVC scores derived by multislice computed tomography do not distinguish between bicuspid and tricuspid aortic valves. The objective of this study was to evaluate the sex-specific differences in the amount of AVC in patients with severe AS and tricuspid (TAV) versus bicuspid (BAV) aortic valve morphologies, retrospectively evaluated by 2 tertiary care institutions. The inclusion criteria comprised patients with severe AS and a left ventricular ejection fraction ≥50% and suitable imaging examinations. The study included 1,450 patients (723 men; 49.9%) with severe AS, including 1,335 patients with TAV (92.1%) and 115 with BAV (17.9%). The calculated Agatston score was higher in BAV patients (men: BAV 4,358 [2,644 to 6,005] AU vs TAV 2,643 [1,727 to 3,794] AU, p <0.01; women: BAV 2,174 [1,330 to 4,378] AU vs TAV 1,703 [964 to 2,534] AU, p <0.01), also when indexed for valve dimensions and body surface area (men: BAV 2,227 [321 to 3,105] AU/m2 vs TAV 1,333 [872 to 1,913] AU/m2, p <0.01; women: BAV 1,326 [782 to 2,148] AU/m2 vs TAV 930 [546 to 1,456] AU/m2, p <0.01). Differences between the BAV- and TAV-derived Agatston score was more prominent in concordant severe AS. In conclusion, sex-specific Agatston scores in severe AS were approximately 1/3 higher in patients with BAV than in patients with TAV for both women and men. Optimal AVC thresholds should be adjusted for BAV, also respecting considerable prognostic implications.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Masculino , Humanos , Femenino , Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagenRESUMEN
BACKGROUND: Initial data about the performance of the new-generation SAPIEN 3 Ultra (S3U) valve are highly promising. However, evidence about the longer-term performance and safety of the S3U is scarce. AIMS: We aimed to investigate the 1-year clinical and echocardiographic outcomes of transcatheter aortic valve implantation (TAVI) using the S3U compared with its predecessor, the SAPIEN 3 valve (S3). METHODS: The SAPIEN 3 Ultra registry included consecutive patients who underwent transfemoral TAVI at 12 European centres with the S3U or S3 between October 2016 and December 2020. One-to-one propensity score (PS) matching was performed to account for differences in baseline characteristics. The primary outcomes of interest were all-cause death and the composite of all-cause death, disabling stroke and hospitalisation for heart failure at 1 year. RESULTS: The overall study cohort encompassed 1,692 patients treated with either the S3U (n=519) or S3 (n=1,173). The PS-matched population had a total of 992 patients (496 per group). At 1 year, the rate of death from any cause was 4.9% in the S3U group and 6.3% in the S3 group (p=0.743). Similarly, there were no significant differences in the rates of the primary composite outcome (9.5% in the S3 group and 6.6% in the S3U group; p=0.162). The S3U was associated with lower rates of mild paravalvular leak (PVL) compared with the S3 (odds ratio 0.63, 95% confidence interval: 0.44 to 0.88; p<0.01). No significant differences in transprosthetic gradients were observed between the two groups. CONCLUSIONS: Compared with the S3, the S3U transcatheter heart valve was associated with similar 1-year clinical outcomes but reduced rates of mild PVL.