Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
BMC Pregnancy Childbirth ; 23(1): 180, 2023 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-36927458

RESUMEN

BACKGROUND: Despite increasing use of continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion (CSII, insulin pumps) in type 1 diabetes (T1D) in pregnancy, achieving recommended pregnancy glycaemic targets (3.5-7.8 mmol/L or 63-140 mg/dL) remains challenging. Consequently, the risk of adverse pregnancy outcomes remains high. Outside pregnancy, hybrid closed-loop (HCL) insulin delivery systems have led to a paradigm shift in the management of T1D, with 12% higher time in glucose target range (TIR) compared to conventional CSII. However, most commercially available HCL systems are currently not approved for use in pregnancy. This study aims to evaluate the efficacy, safety and cost-effectiveness of the MiniMed™ 780G HCL system (Medtronic) in T1D in pregnancy. METHODS: In this international, open-label, randomized controlled trial (RCT), we will compare the MiniMed™ 780G HCL system to standard of care (SoC) in T1D in pregnancy. Women aged 18-45 years with T1D diagnosis of at least one year, HbA1c ≤ 86 mmol/mol (≤ 10%), and confirmed singleton pregnancy up to 11 weeks 6 days will be eligible. After providing written informed consent, all participants will wear a similar CGM system (Guardian™ 3 or Guardian™ 4 CGM) during a 10-day run-in phase. After the run-in phase, participants will be randomised 1:1 to 780G HCL (intervention) or SoC [control, continuation of current T1D treatment with multiple daily injections (MDI) or CSII and any type of CGM] stratified according to centre, baseline HbA1c (< 53 vs. ≥ 53 mmol/mol or < 7 vs. ≥ 7%), and method of insulin delivery (MDI or CSII). The primary outcome will be the time spent within the pregnancy glucose target range, as measured by the CGM at four time points in pregnancy: 14-17, 20-23, 26-29, and 33-36 weeks. Prespecified secondary outcomes will be overnight TIR, time below range (TBR: <3.5 mmol/L or < 63 mg/dL), and overnight TBR. Other outcomes will be exploratory. The planned sample size is 92 participants. The study will end after postpartum discharge from hospital. Analyses will be performed according to intention-to-treat as well as per protocol. DISCUSSION: This large RCT will evaluate a widely used commercially available HCL system in T1D in pregnancy. Recruitment began in January 2021 and was completed in October 2022. Study completion is expected in May 2023. TRIAL REGISTRATION: ClinicalTrials.gov: NCT04520971. Registration date: August 20, 2020. https://clinicaltrials.gov/ct2/show/NCT04520971.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Femenino , Embarazo , Humanos , Insulina/efectos adversos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/efectos adversos , Mujeres Embarazadas , Hemoglobina Glucada , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Glucosa , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
3.
Lancet Diabetes Endocrinol ; 12(6): 390-403, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38697182

RESUMEN

BACKGROUND: Advanced hybrid closed loop (AHCL) therapy can improve glycaemic control in pregnant women with type 1 diabetes. However, data are needed on the efficacy and safety of AHCL systems as these systems, such as the MiniMed 780G, are not currently approved for use in pregnant women. We aimed to investigate whether the MiniMed 780G can improve glycaemic control with less hypoglycaemia in pregnant women with type 1 diabetes. METHODS: CRISTAL was a double-arm, parallel-group, open-label, randomised controlled trial conducted in secondary and tertiary care specialist endocrinology centres at 12 hospitals (11 in Belgium and one in the Netherlands). Pregnant women aged 18-45 years with type 1 diabetes were randomly assigned (1:1) to AHCL therapy (MiniMed 780G) or standard insulin therapy (standard of care) at a median of 10·1 (IQR 8·6-11·6) weeks of gestation. Randomisation was done centrally with minimisation dependent on baseline HbA1c, insulin administration method, and centre. Participants and study teams were not masked to group allocation. The primary outcome was proportion of time spent in the pregnancy-specific target glucose range (3·5-7·8 mmol/L), measured by continuous glucose monitoring (CGM) at 14-17 weeks, 20-23 weeks, 26-29 weeks, and 33-36 weeks. Key secondary outcomes were overnight time in target range, and time below glucose range (<3·5 mmol/L) overall and overnight. Analyses were conducted on an intention-to-treat basis. This trial is registered with ClinicalTrials.gov (NCT04520971). FINDINGS: Between Jan 15, 2021 and Sept 30, 2022, 101 participants were screened, and 95 were randomly assigned to AHCL therapy (n=46) or standard insulin therapy (n=49). 43 patients assigned to AHCL therapy and 46 assigned to standard insulin therapy completed the study. At baseline, 91 (95·8%) participants used insulin pumps, and the mean HbA1c was 6·5% (SD 0·6). The mean proportion of time spent in the target range (averaged over four time periods) was 66·5% (SD 10·0) in the AHCL therapy group compared with 63·2% (12·4) in the standard insulin therapy group (adjusted mean difference 1·88 percentage points [95% CI -0·82 to 4·58], p=0·17). Overnight time in the target range was higher (adjusted mean difference 6·58 percentage points [95% CI 2·31 to 10·85], p=0·0026), and time below range overall (adjusted mean difference -1·34 percentage points [95% CI, -2·19 to -0·49], p=0·0020) and overnight (adjusted mean difference -1·86 percentage points [95% CI -2·90 to -0·81], p=0·0005) were lower with AHCL therapy than with standard insulin therapy. Participants assigned to AHCL therapy reported higher treatment satisfaction. No unanticipated safety events occurred with AHCL therapy. INTERPRETATION: In pregnant women starting with tighter glycaemic control, AHCL therapy did not improve overall time in target range but improved overnight time in target range, reduced time below range, and improved treatment satisfaction. These data suggest that the MiniMed 780G can be safely used in pregnancy and provides some additional benefits compared with standard insulin therapy; however, it will be important to refine the algorithm to better align with pregnancy requirements. FUNDING: Diabetes Liga Research Fund and Medtronic.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Embarazo en Diabéticas , Humanos , Femenino , Embarazo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Adulto , Insulina/administración & dosificación , Insulina/uso terapéutico , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación , Embarazo en Diabéticas/tratamiento farmacológico , Embarazo en Diabéticas/sangre , Glucemia/análisis , Glucemia/efectos de los fármacos , Adulto Joven , Adolescente , Hipoglucemia/inducido químicamente , Control Glucémico/métodos , Automonitorización de la Glucosa Sanguínea/métodos
4.
LGBT Health ; 7(2): 71-81, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32049583

RESUMEN

Purpose: Concerns have been raised about undesired estrogenic effects in assigned female at birth (AFAB) transgender people on testosterone therapy. How serum estradiol levels change after initiation of testosterone therapy and if these levels should be monitored remain unclear. Methods: This prospective cohort study was part of the European Network for the Investigation of Gender Incongruence. Serum levels of sex steroids were assessed in 746 AFAB transgender people during a 3-year follow-up period, starting at the initiation of hormone treatment. Results: Estradiol levels decreased from median [P25-P75] 45.6 [24.0-102.2] pg/mL to 36.5 [25.0-46.2] pg/mL over 3 years (p < 0.001); a change was already noticeable during the first 3 months (mean -17.1 pg/mL, 95% confidence interval -23.8 to -10.6, p < 0.001). Serum estradiol levels were lower in people without endogenous estradiol production from ovarian source (contraceptive users or post hystero-oophorectomy) at baseline and after 3 months, compared with people with endogenous estradiol production. Using long-acting testosterone undecanoate injections resulted in a more prominent decrease in serum estradiol values over 12 months, compared with short-acting mixed testosterone esters (p < 0.001) or testosterone gel (p = 0.001). Changes in serum estradiol were positively correlated to changes in luteinizing hormone (ρ = 0.107, p < 0.001) and negatively correlated to changes in follicle-stimulating hormone levels (ρ = -0.167, p < 0.001) and body mass index (ρ = -0.082, p < 0.001). Conclusion: Testosterone administration in AFAB transgender people resulted in decreasing serum estradiol levels. Our results suggest that testosterone therapy leads to central suppression of estradiol production, with partial restitution due to aromatization.


Asunto(s)
Estradiol/sangre , Terapia de Reemplazo de Hormonas , Testosterona/uso terapéutico , Personas Transgénero , Adulto , Europa (Continente) , Femenino , Humanos , Masculino , Estudios Prospectivos , Personas Transgénero/estadística & datos numéricos , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA