Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Gastrointest Endosc ; 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38065512

RESUMEN

BACKGROUND AND AIMS: Upper GI bleeding (UGIB) is a common medical emergency associated with high resource utilization, morbidity, and mortality. Timely EGD can be challenging from personnel, resource, and access perspectives. PillSense (EnteraSense Ltd, Galway, Ireland) is a novel swallowed bleeding sensor for the detection of UGIB, anticipated to aid in patient triage and guide clinical decision-making for individuals with suspected UGIB. METHODS: This prospective, open-label, single-arm comparative clinical trial of a novel bleeding sensor for patients with suspected UGIB was performed at a tertiary care center. The PillSense system consists of an optical sensor and an external receiver that processes and displays data from the capsule as "Blood Detected" or "No Blood Detected." Patients underwent EGD within 4 hours of capsule administration; participants were followed up for 21 days to confirm capsule passage. RESULTS: A total of 126 patients were accrued to the study (59.5% male; mean age, 62.4 ± 14.3 years). Sensitivity and specificity for detecting the presence of blood were 92.9% (P = .02) and 90.6% (P < .001), respectively. The capsule's positive and negative predictive values were 74.3% and 97.8%, and positive and negative likelihood ratios were 9.9 and .08. No adverse events or deaths occurred related to the PillSense system, and all capsules were excreted from patients on follow-up. CONCLUSIONS: The PillSense system is safe and effective for detecting the presence of blood in patients evaluated for UGIB before upper GI endoscopy. It is a rapidly deployed tool, with easy-to-interpret results that will affect the diagnosis and triage of patients with suspected UGIB. (Clinical trial registration number: NCT05385224.).

2.
Gastrointest Endosc ; 98(1): 122-129, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36889364

RESUMEN

BACKGROUND AND AIMS: Large colon polyps removed by EMR can be complicated by delayed bleeding. Prophylactic defect clip closure can reduce post-EMR bleeding. Larger defects can be challenging to close using through-the-scope clips (TTSCs), and proximal defects are difficult to reach using over-the-scope techniques. A novel, through-the-scope suturing (TTSS) device allows direct closure of mucosal defects without scope withdrawal. The goal of this study was to evaluate the rate of delayed bleeding after the closure of large colon polyp EMR sites with TTSS. METHODS: A multicenter retrospective cohort study was performed involving 13 centers. All defect closure by TTSS after EMR of colon polyps ≥2 cm from January 2021 to February 2022 were included. The primary outcome was rate of delayed bleeding. RESULTS: A total of 94 patients (52% female; mean age, 65 years) underwent EMR of predominantly right-sided (n = 62 [66%]) colon polyps (median size, 35 mm; interquartile range, 30-40 mm) followed by defect closure with TTSS during the study period. All defects were successfully closed with TTSS alone (n = 62 [66%]) or with TTSS and TTSCs (n = 32 [34%]), using a median of 1 (interquartile range, 1-1) TTSS system. Delayed bleeding occurred in 3 patients (3.2%), with 2 requiring repeated endoscopic evaluation/treatment (moderate). CONCLUSION: TTSS alone or with TTSCs was effective in achieving complete closure of all post-EMR defects, despite a large lesion size. After TTSS closure with or without adjunctive devices, delayed bleeding was seen in 3.2% of cases. Further prospective studies are needed to validate these findings before wider adoption of TTSS for large polypectomy closure.


Asunto(s)
Pólipos del Colon , Resección Endoscópica de la Mucosa , Anciano , Femenino , Humanos , Masculino , Colon/cirugía , Colon/patología , Pólipos del Colon/patología , Colonoscopía/métodos , Resección Endoscópica de la Mucosa/efectos adversos , Hemorragia Posoperatoria/epidemiología , Hemorragia Posoperatoria/etiología , Estudios Retrospectivos , Instrumentos Quirúrgicos
3.
ACG Case Rep J ; 9(10): e00868, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36212239

RESUMEN

A 19-year-old man diagnosed with diffuse large B-cell lymphoma undergoing chemotherapy presented for recurrent emesis and weight loss. Imaging studies of the abdomen demonstrated features of superior mesenteric artery syndrome. The patient deferred conservative treatment options and was deemed not to be a surgical candidate. Endoscopic ultrasound-guided gastroenterostomy using a lumen-apposing metal stent was performed to bypass the obstruction. Subsequently, the patient's oral intake and weight significantly improved. The stent was removed 6 months after placement with resolution of superior mesenteric artery syndrome symptoms.

4.
VideoGIE ; 7(12): 423-426, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36471712

RESUMEN

Video 1A novel bedside swallowed optical sensor for detection of upper GI bleeding.

5.
ACG Case Rep J ; 9(11): e00914, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36397884

RESUMEN

[This corrects the article DOI: 10.14309/crj.0000000000000868.].

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA