Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 92(1): 361-373, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38376359

RESUMEN

PURPOSE: The coax monopole antenna is presented for body imaging at 7 T. The antenna is fed at one end, eliminating the possibility of cable-coil coupling and simplifying cable routing. Additionally, its flexibility improves loading to the subject. METHODS: Like the coax dipole antenna, an interruption in the shield of the coaxial cable allows the current to extend to the outside of the shield, generating a B1 + field. Matching is achieved using a single inductor at the distal side, and a cable trap enforces the desired antenna length. Finite difference time domain simulations are employed to optimize the design parameters. Phantom measurements are conducted to determine the antenna's B1 + efficiency and to find the S-parameters in straight and bent positions. Eight-channel simulations and measurements are performed for prostate imaging. RESULTS: The optimal configuration is a length of 360 mm with a gap position of 40 mm. Simulation data show higher B1 + levels for the coax monopole (20% in the prostate), albeit with a 5% lower specific absorbance rate efficiency, compared to the fractionated dipole antenna. The S11 of the coax monopole exhibits remarkable robustness to loading changes. In vivo prostate imaging demonstrates B1 + levels of 10-14 µT with an input power of 8 × 800 W, which is comparable to the fractionated dipole antenna. High-quality images and acceptable coupling levels were achieved. CONCLUSION: The coax monopole is a novel, flexible antenna for body imaging at 7 T. Its simple design incorporates a single inductor at the distal side to achieve matching, and one-sided feeding greatly simplifies cable routing.


Asunto(s)
Simulación por Computador , Diseño de Equipo , Imagen por Resonancia Magnética , Fantasmas de Imagen , Humanos , Imagen por Resonancia Magnética/instrumentación , Masculino , Próstata/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos
2.
Magn Reson Med ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38860561

RESUMEN

PURPOSE: A previously published method for MRI-based transfer function assessment makes use of the so-called transceive phase assumption (TPA). This limits its applicability to shorter leads and/or lower field strengths. A new method is presented where the background electric field is determined from both B 1 + $$ {\mathrm{B}}_1^{+} $$ - and B 1 - $$ {\mathrm{B}}_1^{-} $$ -field distributions, avoiding the TPA and making it more generally applicable. THEORY AND METHODS: These B 1 $$ {\mathrm{B}}_1 $$ -distributions are determined from a spoiled gradient echo multiflip angle acquisition. From the separated B 1 $$ {\mathrm{B}}_1 $$ -components the background electrical field and the induced current are computed. Further improvement is achieved by recasting the B 1 $$ {\mathrm{B}}_1 $$ -field model as a "magnitude squared least squares" problem. The proposed reconstruction method is used to determine transfer functions of various copper wire lengths up to 40 cm inside an elliptical ASTM phantom. The method is first tested on EM-simulated data and subsequently phantom and bench measurements are used to determine transfer functions experimentally. RESULTS: In silica reconstructions demonstrate the validity of the proposed B 1 $$ {\mathrm{B}}_1 $$ -field model resulting in highly accurate reconstructed B 1 $$ {\mathrm{B}}_1 $$ -fields, currents, incident electric fields and transfer functions. The experimental results show slight deviations in the field model, however, resulting transfer functions are accurately determined with high similarity to simulations and comparable to bench measurements. CONCLUSION: A more generally applicable method for MRI-based transfer function assessment is presented. The proposed method circumvents phase assumptions making it applicable for longer objects and/or higher field strengths. Additional improvements are implemented in the B 1 $$ {\mathrm{B}}_1 $$ -mapping method and the solution algorithm.

3.
Magn Reson Med ; 89(6): 2347-2360, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36688273

RESUMEN

PURPOSE: The aim of this work is the development of a thermometry method to measure temperature increases in vivo, with a precision and accuracy sufficient for validation against thermal simulations. Such an MR thermometry model would be a valuable tool to get an indication on one of the major safety concerns in MR imaging: the tissue heating occurring due to radiofrequency (RF) exposure. To prevent excessive temperature rise, RF power deposition, expressed as specific absorption rate, cannot exceed predefined thresholds. Using these thresholds, MRI has demonstrated an extensive history of safe usage. Nevertheless, MR thermometry would be a valuable tool to address some of the unmet needs in the area of RF safety assessment, such as validation of specific absorption rate and thermal simulations, investigation of local peak temperatures during scanning, or temperature-based safety guidelines. METHODS: The harmonic initialized model-based multi-echo approach is proposed. The method combines a previously published model-based multi-echo water/fat separated approach with an also previously published near-harmonic 2D reconstruction method. The method is tested on the human thigh with a multi-transmit array at 7 T, in three volunteers, and for several RF shims. RESULTS: Precision and accuracy are improved considerably compared to a previous fat-referenced method (precision: 0.09 vs. 0.19°C). Comparison of measured temperature rise distributions to subject-specific simulated counterparts show good relative agreement for multiple RF shim settings. CONCLUSION: The high precision shows promising potential for validation purposes and other RF safety applications.


Asunto(s)
Pierna , Termometría , Humanos , Termometría/métodos , Imagen por Resonancia Magnética/métodos , Temperatura , Ondas de Radio , Fantasmas de Imagen
4.
NMR Biomed ; 36(12): e5019, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37622473

RESUMEN

At ultrahigh field strengths images of the body are hampered by B1 -field inhomogeneities. These present themselves as inhomogeneous signal intensity and contrast, which is regarded as a "bias field" to the ideal image. Current bias field correction methods, such as the N4 algorithm, assume a low frequency bias field, which is not sufficiently valid for T2w images at 7 T. In this work we propose a deep learning based bias field correction method to address this issue for T2w prostate images at 7 T. By combining simulated B1 -field distributions of a multi-transmit setup at 7 T with T2w prostate images at 1.5 T, we generated artificial 7 T images for which the homogeneous counterpart was available. Using these paired data, we trained a neural network to correct the bias field. We predicted either a homogeneous image (t-Image neural network) or the bias field (t-Biasf neural network). In addition, we experimented with the single-channel images of the receive array and the corresponding sum of magnitudes of this array as the input image. Testing was carried out on four datasets: the test split of the synthetic training dataset, volunteer and patient images at 7 T, and patient images at 3 T. For the test split, the performance was evaluated using the structural similarity index measure, Wasserstein distance, and root mean squared error. For all other test data, the features Homogeneity and Energy derived from the gray level co-occurrence matrix (GLCM) were used to quantify the improvement. For each test dataset, the proposed method was compared with the current gold standard: the N4 algorithm. Additionally, a questionnaire was filled out by two clinical experts to assess the homogeneity and contrast preservation of the 7 T datasets. All four proposed neural networks were able to substantially reduce the B1 -field induced inhomogeneities in T2w 7 T prostate images. By visual inspection, the images clearly look more homogeneous, which is confirmed by the increase in Homogeneity and Energy in the GLCM, and the questionnaire scores from two clinical experts. Occasionally, changes in contrast within the prostate were observed, although much less for the t-Biasf network than for the t-Image network. Further, results on the 3 T dataset demonstrate that the proposed learning based approach is on par with the N4 algorithm. The results demonstrate that the trained networks were capable of reducing the B1 -field induced inhomogeneities for prostate imaging at 7 T. The quantitative evaluation showed that all proposed learning based correction techniques outperformed the N4 algorithm. Of the investigated methods, the single-channel t-Biasf neural network proves most reliable for bias field correction.


Asunto(s)
Aprendizaje Profundo , Próstata , Masculino , Humanos , Próstata/diagnóstico por imagen , Redes Neurales de la Computación , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
5.
NMR Biomed ; 36(5): e4874, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36368912

RESUMEN

The purpose of this work is to propose a tier-based formalism for safety assessment of custom-built radio-frequency (RF) coils that balances validation effort with the effort put in determinating the safety factor. The formalism has three tier levels. Higher tiers require increased effort when validating electromagnetic simulation results but allow for less conservative safety factors. In addition, we propose a new method to calculate modeling uncertainty between simulations and measurements and a new method to propagate uncertainties in the simulation into a safety factor that minimizes the risk of underestimating the peak specific absorption rate (SAR). The new safety assessment procedure was completed for all tier levels for an eight-channel dipole array for prostate imaging at 7 T and an eight-channel dipole array for head imaging at 10.5 T, using data from two different research sites. For the 7 T body array, the validation procedure resulted in a modeling uncertainty of 77% between measured and simulated local SAR distributions. For a situation where RF shimming is performed on the prostate, average power limits of 2.4 and 4.5 W/channel were found for tiers 2 and 3, respectively. When the worst-case peak SAR among all phase settings was calculated, power limits of 1.4 and 2.7 W/channel were found for tiers 2 and 3, respectively. For the 10.5 T head array, a modeling uncertainty of 21% was found based on B1 + mapping. For the tier 2 validation, a power limit of 2.6 W/channel was calculated. The demonstrated tier system provides a strategy for evaluating modeling inaccuracy, allowing for the rapid translation of novel coil designs with conservative safety factors and the implementation of less conservative safety factors for frequently used coil arrays at the expense of increased validation effort.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Simulación por Computador , Próstata/diagnóstico por imagen
6.
MAGMA ; 36(2): 245-255, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37000320

RESUMEN

INTRODUCTION: Various research sites are pursuing 14 T MRI systems. However, both local SAR and RF transmit field inhomogeneity will increase. The aim of this simulation study is to investigate the trade-offs between peak local SAR and flip angle uniformity for five transmit coil array designs at 14 T in comparison to 7 T. METHODS: Investigated coil array designs are: 8 dipole antennas (8D), 16 dipole antennas (16D), 8 loop coils (8D), 16 loop coils (16L), 8 dipoles/8 loop coils (8D8L) and for reference 8 dipoles at 7 T. Both RF shimming and kT-points were investigated by plotting L-curves of peak SAR levels vs flip angle homogeneity. RESULTS: For RF shimming, the 16L array performs best. For kT-points, superior flip angle homogeneity is achieved at the expense of more power deposition, and the dipole arrays outperform the loop coil arrays. DISCUSSION AND CONCLUSION: For most arrays and regular imaging, the constraint on head SAR is reached before constraints on peak local SAR are violated. Furthermore, the different drive vectors in kT-points alleviate strong peaks in local SAR. Flip angle inhomogeneity can be alleviated by kT-points at the expense of larger power deposition. For kT-points, the dipole arrays seem to outperform loop coil arrays.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Simulación por Computador , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
7.
Proc Natl Acad Sci U S A ; 117(41): 25818-25829, 2020 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-32973092

RESUMEN

Hippocampus-engaged behaviors stimulate neurogenesis in the adult dentate gyrus by largely unknown means. To explore the underlying mechanisms, we used tetrode recording to analyze neuronal activity in the dentate gyrus of freely moving adult mice during hippocampus-engaged contextual exploration. We found that exploration induced an overall sustained increase in inhibitory neuron activity that was concomitant with decreased excitatory neuron activity. A mathematical model based on energy homeostasis in the dentate gyrus showed that enhanced inhibition and decreased excitation resulted in a similar increase in neurogenesis to that observed experimentally. To mechanistically investigate this sustained inhibitory regulation, we performed metabolomic and lipidomic profiling of the hippocampus during exploration. We found sustainably increased signaling of sphingosine-1-phosphate, a bioactive metabolite, during exploration. Furthermore, we found that sphingosine-1-phosphate signaling through its receptor 2 increased interneuron activity and thus mediated exploration-induced neurogenesis. Taken together, our findings point to a behavior-metabolism circuit pathway through which experience regulates adult hippocampal neurogenesis.


Asunto(s)
Hipocampo/metabolismo , Neurogénesis , Animales , Encéfalo/crecimiento & desarrollo , Encéfalo/metabolismo , Femenino , Hipocampo/química , Hipocampo/citología , Metabolismo de los Lípidos , Lisofosfolípidos/metabolismo , Masculino , Ratones , Ratones Endogámicos C57BL , Modelos Teóricos , Plasticidad Neuronal , Neuronas/citología , Neuronas/metabolismo , Esfingosina/análogos & derivados , Esfingosina/metabolismo
8.
Nat Mater ; 20(12): 1683-1688, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34294884

RESUMEN

Superionic conductors possess liquid-like ionic diffusivity in the solid state, finding wide applicability from electrolytes in energy storage to materials for thermoelectric energy conversion. Type I superionic conductors (for example, AgI, Ag2Se and so on) are defined by a first-order transition to the superionic state and have so far been found exclusively in three-dimensional crystal structures. Here, we reveal a two-dimensional type I superionic conductor, α-KAg3Se2, by scattering techniques and complementary simulations. Quasi-elastic neutron scattering and ab initio molecular dynamics simulations confirm that the superionic Ag+ ions are confined to subnanometre sheets, with the simulated local structure validated by experimental X-ray powder pair-distribution-function analysis. Finally, we demonstrate that the phase transition temperature can be controlled by chemical substitution of the alkali metal ions that compose the immobile charge-balancing layers. Our work thus extends the known classes of superionic conductors and will facilitate the design of new materials with tailored ionic conductivities and phase transitions.

9.
Magn Reson Med ; 87(1): 528-540, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34411327

RESUMEN

PURPOSE: The coax dipole antenna, a flexible antenna for body imaging at 7T is presented. Similar to the high impedance coil, this coaxial cable antenna is fed on the central conductor and through gaps in the shield, the current passes to the outside of the antenna to generate B1 field. This could achieve more favorable current distributions and better adaptation to the body curvature. METHODS: Finite difference time domain (FDTD) simulations are performed to optimize the positions of the gaps in the shield for a flat current profile. Lumped inductors are added to each end to reduce losses. The performance of a single antenna is compared to a fractionated dipole using B1 maps and MR thermometry. Finally, an array of eight coax dipoles is evaluated in simulations and used for in-vivo scanning. RESULTS: An optimal configuration is found with gaps located at 10 cm from the center and inductor values of 28 nH. In comparison to the fractionated dipole antenna, in single antenna phantom measurements the coax dipole achieves similar B1 amplitude with 18% lower peak temperature. In simulations, the eight-channel array of coax dipoles improved B1 homogeneity by 18%, along with small improvements in transmit efficiency and specific absorption rate (SAR). MRI measurements on three volunteers show more consistent performance for the coax dipoles. CONCLUSION: The coax dipole is a novel antenna design with a flattened current distribution resulting in beneficial properties. Also, the flexible design of the coax dipoles allows better adaptation to the body curvature and can potentially be used for a wide range of imaging targets.


Asunto(s)
Imagen por Resonancia Magnética , Diseño de Equipo , Humanos , Fantasmas de Imagen
10.
J Am Chem Soc ; 143(17): 6601-6608, 2021 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-33887906

RESUMEN

Computational studies with ωB97X-D density functional theory of the mechanisms of the steps in Trauner's biomimetic synthesis of preuisolactone A have elaborated and refined mechanisms of several unique processes. An ambimodal transition state has been identified for the cycloaddition between an o-quinone and a hydroxy-o-quinone; this leads to both (5 + 2) (with H shift) and (4 + 2) cycloaddition products, which can in principle interconvert via α-ketol rearrangements. The origins of periselectivity of this ambimodal cycloaddition have been investigated computationally with molecular dynamics simulations and tested further by an experimental study. In the presence of bicarbonate ions, the deprotonated hydroxy-o-quinone leads to only the (5 + 2) cycloaddition adduct. A new mechanism for a benzilic acid rearrangement resulting in ring contraction is proposed.


Asunto(s)
Lactonas/síntesis química , Sesquiterpenos/síntesis química , Bicarbonatos/química , Biomimética/métodos , Reacción de Cicloadición , Hidroquinonas/química , Lactonas/química , Quinonas/química , Sesquiterpenos/química
11.
Magn Reson Med ; 85(6): 3420-3433, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33350525

RESUMEN

PURPOSE: Multi-transmit MRI systems are typically equipped with dedicated hardware to sample the reflected/lost power in the transmit channels. After extensive calibration, the amplitude and phase of the signal at the feed of each array element can be accurately determined. However, determining the phase is more difficult and monitoring errors can lead to a hazardous peak local specific absorption rate (pSAR10g ) underestimation. For this purpose, methods were published for online maximum potential pSAR10g estimation without relying on phase monitoring, but these methods produce considerable overestimation. We present a trigonometric maximization method to determine the actual worst-case pSAR10g without any overestimation. THEORY AND METHOD: The proposed method takes advantage of the sinusoidal relation between the SAR10g in each voxel and the phases of input signals, to return the maximum achievable SAR10g in a few iterations. The method is applied to determine the worst-case pSAR10g for three multi-transmit array configurations at 7T: (1) body array with eight fractionated dipoles; (2) head array with eight fractionated dipoles; (3) head array with eight rectangular loops. The obtained worst-case pSAR10g values are compared with the pSAR10g values determined with a commonly used method and with a more efficient method based on reference-phases. RESULTS: For each voxel, the maximum achievable SAR10g is determined in less than 0.1 ms. Compared to the reference-phases-based method, the proposed method reduces the mean overestimation of the actual pSAR10g up to 52%, while never underestimating the true pSAR10g . CONCLUSION: The proposed method can widely improve the performance of parallel transmission MRI systems without phase monitoring.


Asunto(s)
Cabeza , Imagen por Resonancia Magnética , Simulación por Computador , Fantasmas de Imagen
12.
Magn Reson Med ; 86(5): 2751-2765, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34036617

RESUMEN

PURPOSE: To propose a single setup using the MRI to both measure and validate the transfer function (TF) of linear implants. Conventionally, the TF of an implant is measured in one bench setup and validated using another. METHODS: It has been shown that the TF can be measured using MRI. To validate this measurement, the implant is exposed to different incident electric fields, while the temperature increase at the tip is monitored. For a good validation, the incident electric fields that the implant is exposed to should be orthogonal. We perform a simulation study on six different methods that change the incident electric field. Afterward, a TF measurement and validation study using the best method from the simulations is performed. This is done with fiberoptic temperature probes at 1.5 T for four linear implant structures using the proposed single setup. RESULTS: The simulation study showed that positioning local transmit coils at different locations along the lead trajectory has a similar validation quality compared with changing the implant trajectory (ie, the conventional validation method). For the validation study that was performed, an R2 ≥ 0.91 was found for the four investigated leads. CONCLUSION: A single setup to both measure and validate the transfer function using local transmit coils has been shown to work. The benefits of using the proposed validation method are that there is only one setup required instead of two and the implant trajectory is not varied; therefore, the relative distance between the leap tip and the temperature probe is constant.


Asunto(s)
Campos Electromagnéticos , Ondas de Radio , Imagen por Resonancia Magnética , Fantasmas de Imagen , Prótesis e Implantes
13.
NMR Biomed ; 34(7): e4525, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33955061

RESUMEN

PURPOSE: To investigate inter-subject variability of B1+ , SAR and temperature rise in a database of human models using a local transmit array for 7 T cardiac imaging. METHODS: Dixon images were acquired of 14 subjects and segmented in dielectric models with an eight-channel local transmit array positioned around the torso for cardiac imaging. EM simulations were done to calculate SAR distributions. Based on the SAR distributions, temperature simulations were performed for exposure times of 6 min and 30 min. Peak local SAR and temperature rise levels were calculated for different RF shim settings. A statistical analysis of the resulting peak local SAR and temperature rise levels was performed to arrive at safe power limits. RESULTS: For RF shim vectors with random phase and uniformly distributed power, a safe average power limit of 35.7 W was determined (first level controlled mode). When RF amplitude and phase shimming was performed on the heart, a safe average power limit of 35.0 W was found. According to Pennes' model, our numerical study suggests a very low probability of exceeding the absolute local temperature limit of 40 °C for a total exposure time of 6 min and a peak local SAR of 20 W/kg. For a 30 min exposure time at 20 W/kg, it was shown that the absolute temperature limit can be exceeded in the case where perfusion does not change with temperature. CONCLUSION: Safe power constraints were found for 7 T cardiac imaging with an eight-channel local transmit array, while considering the inter-subject variability of B1+ , SAR and temperature rise.


Asunto(s)
Absorción de Radiación , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Temperatura , Adulto , Simulación por Computador , Campos Electromagnéticos , Humanos , Persona de Mediana Edad , Modelos Biológicos
14.
Nat Chem Biol ; 15(6): 623-631, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31036923

RESUMEN

Sphingosine-1-phosphate (S1P) plays important roles as a signaling lipid in a variety of physiological and pathophysiological processes. S1P signals via a family of G-protein-coupled receptors (GPCRs) (S1P1-5) and intracellular targets. Here, we report on photoswitchable analogs of S1P and its precursor sphingosine, respectively termed PhotoS1P and PhotoSph. PhotoS1P enables optical control of S1P1-3, shown through electrophysiology and Ca2+ mobilization assays. We evaluated PhotoS1P in vivo, where it reversibly controlled S1P3-dependent pain hypersensitivity in mice. The hypersensitivity induced by PhotoS1P is comparable to that induced by S1P. PhotoS1P is uniquely suited for the study of S1P biology in cultured cells and in vivo because it exhibits prolonged metabolic stability compared to the rapidly metabolized S1P. Using lipid mass spectrometry analysis, we constructed a metabolic map of PhotoS1P and PhotoSph. The formation of these photoswitchable lipids was found to be light dependent, providing a novel approach to optically probe sphingolipid biology.


Asunto(s)
Lisofosfolípidos/metabolismo , Esfingosina/análogos & derivados , Animales , Lisofosfolípidos/química , Ratones , Modelos Moleculares , Estructura Molecular , Imagen Óptica , Procesos Fotoquímicos , Esfingosina/química , Esfingosina/metabolismo
15.
J Magn Reson Imaging ; 53(2): 333-346, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32830900

RESUMEN

Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh-field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer-published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2 J. MAGN. RESON. IMAGING 2021;53:333-346.


Asunto(s)
Campos Magnéticos , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/efectos adversos , Espectroscopía de Resonancia Magnética , Física
16.
J Am Chem Soc ; 142(13): 6312-6323, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32160464

RESUMEN

Subchalcogenides are uncommon compounds where the metal atoms are in unusually low formal oxidation states. They bridge the gap between intermetallics and semiconductors and can have unexpected structures and properties because of the exotic nature of their chemical bonding as they contain both metal-metal and metal-main group (e.g., halide, chalcogenide) interactions. Finding new members of this class of materials presents synthetic challenges as attempts to make them often result in phase separation into binary compounds. We overcome this difficulty by utilizing indium as a metal flux to synthesize large (millimeter scale) single crystals of novel subchalcogenide materials. Herein, we report two new compounds Ir2In8Q (Q = Se, Te) and compare their structural and electrical properties to the previously reported Ir2In8S analogue. Ir2In8Se and Ir2In8Te crystallize in the P42/mnm space group and are isostructural to Ir2In8S, but also have commensurately modulated (with q vectors q = 1/6a* + 1/6b* and q = 1/10a* + 1/10b* for Ir2In8Se and Ir2In8Te, respectively) low-temperature phase transitions, where the chalcogenide anions in the channels experience a distortion in the form of In-Q bond alternation along the ab plane. Both compounds display re-entrant structural behavior, where the supercells appear on cooling but revert to the original subcell below 100 K, suggesting competing structural and electronic interactions dictate the overall structure. Notably, these materials are topological semimetal candidates with symmetry-protected Dirac crossings near the Fermi level and exhibit high electron mobilities (∼1500 cm2 V-1 s-1 at 1.8 K) and moderate carrier concentrations (∼1020 cm-3) from charge transport measurements. This work highlights metal flux as a synthetic route to high quality single crystals of novel intermetallic subchalcogenides with Dirac semimetal behavior.

17.
Magn Reson Med ; 84(6): 3379-3395, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32492249

RESUMEN

PURPOSE: The introduction of a linear safety factor to address peak local specific absorption rate (pSAR10g ) uncertainties (eg, intersubject variation, modeling inaccuracies) bears one considerable drawback: It often results in over-conservative scanning constraints. We present a more efficient approach to define a variable safety margin based on the conditional probability density function of the effectively obtained pSAR10g value, given the estimated pSAR10g value. METHODS: The conditional probability density function can be estimated from previously simulated data. A representative set of true and estimated pSAR10g samples was generated by means of our database of 23 subject-specific models with an 8-fractionated dipole array for prostate imaging at 7 T. The conditional probability density function was calculated for each possible estimated pSAR10g value and used to determine the corresponding safety margin with an arbitrary low probability of underestimation. This approach was applied to five state-of-the-art local SAR estimation methods, namely: (1) using just the generic body model "Duke"; (2) using our model library to assess the maximum pSAR10g value over all models; (3) using the most representative "local SAR model"; (4) using the five most representative local SAR models; and (5) using a recently developed deep learning-based method. RESULTS: Compared with the more conventional safety factor, the conditional safety-margin approach results in lower (up to 30%) mean overestimation for all investigated local SAR estimation methods. CONCLUSION: The proposed probabilistic approach for pSAR10g correction allows more accurate local SAR assessment with much lower overestimation, while a predefined level of underestimation is accepted (eg, 0.1%).


Asunto(s)
Imagen por Resonancia Magnética , Próstata , Simulación por Computador , Bases de Datos Factuales , Masculino
18.
Magn Reson Med ; 83(3): 1081-1095, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31631400

RESUMEN

PURPOSE: A purely experimental method for MRI-based transfer function (TF) determination is presented. A TF characterizes the potential for radiofrequency heating of a linear implant by relating the incident tangential electric field to a scattered electric field at its tip. We utilize the previously introduced transfer matrix (TM) to determine transfer functions solely from the MR measurable quantities, that is, the B1+ and transceive phase distributions. This technique can extend the current practice of phantom-based TF assessment with dedicated experimental setup toward MR-based methods that have the potential to assess the TF in more realistic situations. THEORY AND METHODS: An analytical description of the B1+ magnitude and transceive phase distribution around a wire-like implant was derived based on the TM. In this model, the background field is described using a superposition of spherical and cylindrical harmonics while the transfer matrix is parameterized using a previously introduced attenuated wave model. This analytical description can be used to estimate the transfer matrix and transfer function based on the measured B1+ distribution. RESULTS: The TF was successfully determined for 2 mock-up implants: a 20-cm bare copper wire and a 20-cm insulated copper wire with 10 mm of insulation stripped at both endings in respectively 4 and 3 different trajectories. The measured TFs show a strong correlation with a reference determined from simulations and between the separate experiments with correlation coefficients above 0.96 between all TFs. Compared to the simulated TF, the maximum deviation in the estimated tip field is 9.4% and 12.2% for the bare and insulated wire, respectively. CONCLUSIONS: A method has been developed to measure the TF of medical implants using MRI experiments. Jointly fitting the incident and scattered B1+ distributions with an analytical description based on the transfer matrix enables accurate determination of the TF of 2 test implants. The presented method no longer needs input from simulated data and can therefore, in principle, be used to measure TF's in test animals or corpses.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Algoritmos , Celulosa/análogos & derivados , Celulosa/química , Simulación por Computador , Cobre , Campos Electromagnéticos , Humanos , Modelos Estadísticos , Polimetil Metacrilato/química , Prótesis e Implantes , Ondas de Radio , Reproducibilidad de los Resultados
19.
Magn Reson Med ; 83(5): 1796-1809, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31566265

RESUMEN

PURPOSE: Patients who have medical metallic implants, e.g. orthopaedic implants and pacemakers, often cannot undergo an MRI exam. One of the largest risks is tissue heating due to the radio frequency (RF) fields. The RF safety assessment of implants is computationally demanding. This is due to the large dimensions of the transmit coil compared to the very detailed geometry of an implant. METHODS: In this work, we explore a faster computational method for the RF safety assessment of implants that exploits the small geometry. The method requires the RF field without an implant as a basis and calculates the perturbation that the implant induces. The inputs for this method are the incident fields and a library matrix that contains the RF field response of every edge an implant can occupy. Through a low-rank inverse update, using the Sherman-Woodbury-Morrison matrix identity, the EM response of arbitrary implants can be computed within seconds. We compare the solution from full-wave simulations with the results from the presented method, for two implant geometries. RESULTS: From the comparison, we found that the resulting electric and magnetic fields are numerically equivalent (maximum error of 1.35%). However, the computation was between 171 to 2478 times faster than the corresponding GPU accelerated full-wave simulation. CONCLUSIONS: The presented method enables for rapid and efficient evaluation of the RF fields near implants and might enable situation-specific scanning conditions.


Asunto(s)
Campos Electromagnéticos , Ondas de Radio , Simulación por Computador , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Prótesis e Implantes
20.
J Am Chem Soc ; 141(39): 15515-15518, 2019 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-31518120

RESUMEN

A short, biomimetic synthesis of the fungal metabolite preuisolactone A is described. Its key steps are a purpurogallin-type (5 + 2)-cycloaddition, followed by fragmentation, vinylogous aldol addition, oxidative lactonization, and a final benzilic acid rearrangement. Our work explains why preuisolactone A has been isolated as a racemate and suggests that the natural product is not a sesquiterpenoid but a phenolic polyketide.


Asunto(s)
Lactonas/síntesis química , Sesquiterpenos/síntesis química , Productos Biológicos/síntesis química , Hongos , Lactonas/química , Modelos Moleculares , Estructura Molecular , Sesquiterpenos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA