Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
IEEE Sens J ; 19(13): 4743-4751, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32863779

RESUMEN

Monitoring blood coagulation in response to an anticoagulant (heparin) and its reversal agent (protamine) is essential during and after surgery, especially with cardiopulmonary bypass (CPB). A current clinical standard is the use of activated clotting time (ACT), where the mechanical movement of a plunger through a whole blood-filled channel is monitored to evaluate the endpoint time of coagulation. As a rapid, simple, low-volume, and cost-effective alternative, we have developed a paper microfluidic assay and Raspberry Pi-based device with the aim of quantifying the extent of blood coagulation in response to varying doses of heparin and protamine. The flow rate of blood through the paper microfluidic channel is automatically monitored using Python-coded edge detection algorithm. For each set of assay, 8 µL of fresh human whole blood (untreated and undiluted) from human subjects is loaded onto each of 8 sample pads, which have been preloaded with varying amounts of heparin or protamine. Total assay time is 3-5 minutes including the time for sample loading and incubation.

2.
J Extra Corpor Technol ; 51(1): 29-37, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30936586

RESUMEN

Direct thrombin inhibitors (DTIs), such as bivalirudin and dabigatran, have maintained steady inpatient and outpatient use as substitutes for heparin and warfarin, respectively, because of their high bioavailability and relatively safe "on-therapy" range. Current clinical methods lack the capacity to directly quantify plasma DTI concentrations across wide ranges. At present, the gold standard is the ecarin clotting time (ECT), where ecarin maximizes thrombin activity and clotting time is evaluated to assess DTIs' anticoagulation capability. This work focused on the development of a microfluidic paper analytic device (µPAD) that can quantify the extent of anticoagulation as well as DTI concentration within a patient's whole blood sample. Capillary action propels a small blood sample to flow through the nitrocellulose paper channels. Digital images of whole blood migration are then captured by our self-coded Raspberry Pi and/or the Samsung Galaxy S8 smartphone camera. Both the flow length and the blue absorbance from the plasma front on the µPAD were measured, allowing simultaneous, dual assays: ecarin clotting test (ECT) and ecarin chromogenic assay (ECA). Statistically significant (p < .05) changes in flow and absorbance were observed within our translational research study. Currently, there are no quantitative, commercially available point-of-care tests for the ECT and ECA within the United States. Both the ECT and ECA assays could be instrumental to differentiate between supratherapeutic and subtherapeutic incidents during bridging anticoagulant therapy and limit the unwarranted use of reversal agents.


Asunto(s)
Antitrombinas , Sistemas de Atención de Punto , Anticoagulantes , Pruebas de Coagulación Sanguínea , Endopeptidasas , Humanos , Microfluídica , Trombina
3.
Catheter Cardiovasc Interv ; 92(5): 1002-1004, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29205886

RESUMEN

We describe the off-pump insertion of a biventricular assist device with extra-corporeal membrane oxygenation (ECMO): a novel technique that allows for ambulatory central veno-arterial (VA) ECMO with direct biventricular decompression.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Implantación de Prótesis/instrumentación , Choque Cardiogénico/terapia , Función Ventricular Izquierda , Función Ventricular Derecha , Enfermedad Aguda , Adulto , Humanos , Masculino , Recuperación de la Función , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/fisiopatología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA