Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 91(5): 1787-1802, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37811778

RESUMEN

PURPOSE: To create an inventory of image processing pipelines of arterial spin labeling (ASL) and list their main features, and to evaluate the capability, flexibility, and ease of use of publicly available pipelines to guide novice ASL users in selecting their optimal pipeline. METHODS: Developers self-assessed their pipelines using a questionnaire developed by the Task Force 1.1 of the ISMRM Open Science Initiative for Perfusion Imaging. Additionally, each publicly available pipeline was evaluated by two independent testers with basic ASL experience using a scoring system created for this purpose. RESULTS: The developers of 21 pipelines filled the questionnaire. Most pipelines are free for noncommercial use (n = 18) and work with the standard NIfTI (Neuroimaging Informatics Technology Initiative) data format (n = 15). All pipelines can process standard 3D single postlabeling delay pseudo-continuous ASL images and primarily differ in their support of advanced sequences and features. The publicly available pipelines (n = 9) were included in the independent testing, all of them being free for noncommercial use. The pipelines, in general, provided a trade-off between ease of use and flexibility for configuring advanced processing options. CONCLUSION: Although most ASL pipelines can process the common ASL data types, only some (namely, ASLPrep, ASLtbx, BASIL/Quantiphyse, ExploreASL, and MRICloud) are well-documented, publicly available, support multiple ASL types, have a user-friendly interface, and can provide a useful starting point for ASL processing. The choice of an optimal pipeline should be driven by specific data to be processed and user experience, and can be guided by the information provided in this ASL inventory.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Marcadores de Spin , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Arterias , Imagen de Perfusión , Circulación Cerebrovascular , Imagen por Resonancia Magnética/métodos , Perfusión
2.
Magn Reson Med ; 92(2): 836-852, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38502108

RESUMEN

PURPOSE: Arterial spin labeling (ASL) is a widely used contrast-free MRI method for assessing cerebral blood flow (CBF). Despite the generally adopted ASL acquisition guidelines, there is still wide variability in ASL analysis. We explored this variability through the ISMRM-OSIPI ASL-MRI Challenge, aiming to establish best practices for more reproducible ASL analysis. METHODS: Eight teams analyzed the challenge data, which included a high-resolution T1-weighted anatomical image and 10 pseudo-continuous ASL datasets simulated using a digital reference object to generate ground-truth CBF values in normal and pathological states. We compared the accuracy of CBF quantification from each team's analysis to the ground truth across all voxels and within predefined brain regions. Reproducibility of CBF across analysis pipelines was assessed using the intra-class correlation coefficient (ICC), limits of agreement (LOA), and replicability of generating similar CBF estimates from different processing approaches. RESULTS: Absolute errors in CBF estimates compared to ground-truth synthetic data ranged from 18.36 to 48.12 mL/100 g/min. Realistic motion incorporated into three datasets produced the largest absolute error and variability between teams, with the least agreement (ICC and LOA) with ground-truth results. Fifty percent of the submissions were replicated, and one produced three times larger CBF errors (46.59 mL/100 g/min) compared to submitted results. CONCLUSIONS: Variability in CBF measurements, influenced by differences in image processing, especially to compensate for motion, highlights the significance of standardizing ASL analysis workflows. We provide a recommendation for ASL processing based on top-performing approaches as a step toward ASL standardization.


Asunto(s)
Encéfalo , Circulación Cerebrovascular , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Marcadores de Spin , Humanos , Circulación Cerebrovascular/fisiología , Reproducibilidad de los Resultados , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Masculino , Femenino , Adulto , Algoritmos
3.
J Am Soc Nephrol ; 34(6): 1090-1104, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36890644

RESUMEN

SIGNIFICANCE STATEMENT: Hemodialysis (HD) results in reduced brain blood flow, and HD-related circulatory stress and regional ischemia are associated with brain injury over time. However, studies to date have not provided definitive direct evidence of acute brain injury during a HD treatment session. Using intradialytic magnetic resonance imaging (MRI) and spectroscopy to examine HD-associated changes in brain structure and neurochemistry, the authors found that multiple white (WM) tracts had diffusion imaging changes characteristic of cytotoxic edema, a consequence of ischemic insult and a precursor to fixed structural WM injury. Spectroscopy showed decreases in prefrontal N -acetyl aspartate (NAA) and choline concentrations consistent with energy deficit and perfusion anomaly. This suggests that one HD session can cause brain injury and that studies of interventions that mitigate this treatment's effects on the brain are warranted. BACKGROUND: Hemodialysis (HD) treatment-related hemodynamic stress results in recurrent ischemic injury to organs such as the heart and brain. Short-term reduction in brain blood flow and long-term white matter changes have been reported, but the basis of HD-induced brain injury is neither well-recognized nor understood, although progressive cognitive impairment is common. METHODS: We used neurocognitive assessments, intradialytic anatomical magnetic resonance imaging, diffusion tensor imaging, and proton magnetic resonance spectroscopy to examine the nature of acute HD-associated brain injury and associated changes in brain structure and neurochemistry relevant to ischemia. Data acquired before HD and during the last 60 minutes of HD (during maximal circulatory stress) were analyzed to assess the acute effects of HD on the brain. RESULTS: We studied 17 patients (mean age 63±13 years; 58.8% were male, 76.5% were White, 17.6% were Black, and 5.9% were of Indigenous ethnicity). We found intradialytic changes, including the development of multiple regions of white matter exhibiting increased fractional anisotropy with associated decreases in mean diffusivity and radial diffusivity-characteristic features of cytotoxic edema (with increase in global brain volumes). We also observed decreases in proton magnetic resonance spectroscopy-measured N -acetyl aspartate and choline concentrations during HD, indicative of regional ischemia. CONCLUSIONS: This study demonstrates for the first time that significant intradialytic changes in brain tissue volume, diffusion metrics, and brain metabolite concentrations consistent with ischemic injury occur in a single dialysis session. These findings raise the possibility that HD might have long-term neurological consequences. Further study is needed to establish an association between intradialytic magnetic resonance imaging findings of brain injury and cognitive impairment and to understand the chronic effects of HD-induced brain injury. CLINICAL TRIALS INFORMATION: NCT03342183 .


Asunto(s)
Lesiones Encefálicas , Sustancia Blanca , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Imagen de Difusión Tensora/métodos , Ácido Aspártico/metabolismo , Imagen por Resonancia Magnética , Lesiones Encefálicas/etiología , Lesiones Encefálicas/metabolismo , Lesiones Encefálicas/patología , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Sustancia Blanca/diagnóstico por imagen , Diálisis Renal/efectos adversos , Análisis Espectral , Colina/metabolismo
4.
NMR Biomed ; : e4992, 2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37401341

RESUMEN

The global disparity of magnetic resonance imaging (MRI) is a major challenge, with many low- and middle-income countries (LMICs) experiencing limited access to MRI. The reasons for limited access are technological, economic and social. With the advancement of MRI technology, we explore why these challenges still prevail, highlighting the importance of MRI as the epidemiology of disease changes in LMICs. In this paper, we establish a framework to develop MRI with these challenges in mind and discuss the different aspects of MRI development, including maximising image quality using cost-effective components, integrating local technology and infrastructure and implementing sustainable practices. We also highlight the current solutions-including teleradiology, artificial intelligence and doctor and patient education strategies-and how these might be further improved to achieve greater access to MRI.

5.
NMR Biomed ; 36(3): e4846, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36259628

RESUMEN

Magnetic resonance imaging (MRI) technology has profoundly transformed current healthcare systems globally, owing to advances in hardware and software research innovations. Despite these advances, MRI remains largely inaccessible to clinicians, patients, and researchers in low-resource areas, such as Africa. The rapidly growing burden of noncommunicable diseases in Africa underscores the importance of improving access to MRI equipment as well as training and research opportunities on the continent. The Consortium for Advancement of MRI Education and Research in Africa (CAMERA) is a network of African biomedical imaging experts and global partners, implementing novel strategies to advance MRI access and research in Africa. Upon its inception in 2019, CAMERA sets out to identify challenges to MRI usage and provide a framework for addressing MRI needs in the region. To this end, CAMERA conducted a needs assessment survey (NAS) and a series of symposia at international MRI society meetings over a 2-year period. The 68-question NAS was distributed to MRI users in Africa and was completed by 157 clinicians and scientists from across Sub-Saharan Africa (SSA). On average, the number of MRI scanners per million people remained at less than one, of which 39% were obsolete low-field systems but still in use to meet daily clinical needs. The feasibility of coupling stable energy supplies from various sources has contributed to the growing number of higher-field (1.5 T) MRI scanners in the region. However, these systems are underutilized, with only 8% of facilities reporting clinical scans of 15 or more patients per day, per scanner. The most frequently reported MRI scans were neurological and musculoskeletal. The CAMERA NAS combined with the World Health Organization and International Atomic Energy Agency data provides the most up-to-date data on MRI density in Africa and offers a unique insight into Africa's MRI needs. Reported gaps in training, maintenance, and research capacity indicate ongoing challenges in providing sustainable high-value MRI access in SSA. Findings from the NAS and focused discussions at international MRI society meetings provided the basis for the framework presented here for advancing MRI capacity in SSA. While these findings pertain to SSA, the framework provides a model for advancing imaging needs in other low-resource settings.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , África del Sur del Sahara , Encuestas y Cuestionarios
6.
J Magn Reson Imaging ; 2023 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-37589418

RESUMEN

BACKGROUND: Ischemic heart disease (IHD) is linked to brain white matter (WM) breakdown but how age or disease effects WM integrity, and whether it is reversible using cardiac rehabilitation (CR), remains unclear. PURPOSE: To assess the effects of brain aging, cardiovascular disease, and CR on WM microstructure in brains of IHD patients following a cardiac event. STUDY TYPE: Retrospective. POPULATION: Thirty-five IHD patients (9 females; mean age = 59 ± 8 years), 21 age-matched healthy controls (10 females; mean age = 59 ± 8 years), and 25 younger controls (14 females; mean age = 26 ± 4 years). FIELD STRENGTH/SEQUENCE: 3 T diffusion-weighted imaging with single-shot echo planar imaging acquired at 3 months and 9 months post-cardiac event. ASSESSMENT: Tract-based spatial statistics (TBSS) and tractometry were used to compare fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) in cerebral WM between: 1) older and younger controls to distinguish age-related from disease-related WM changes; 2) IHD patients at baseline (pre-CR) and age-matched controls to investigate if cardiovascular disease exacerbates age-related WM changes; and 3) IHD patients pre-CR and post-CR to investigate the neuroplastic effect of CR on WM microstructure. STATISTICAL TESTS: Two-sample unpaired t-test (age: older vs. younger controls; IHD: IHD pre-CR vs. age-matched controls). One-sample paired t-test (CR: IHD pre- vs. post-CR). Statistical threshold: P < 0.05 (FWE-corrected). RESULTS: TBSS and tractometry revealed widespread WM changes in older controls compared to younger controls while WM clusters of decreased FA in the fornix and increased MD in body of corpus callosum were observed in IHD patients pre-CR compared to age-matched controls. Robust WM improvements (increased FA, increased AD) were observed in IHD patients post-CR. DATA CONCLUSION: In IHD, both brain aging and cardiovascular disease may contribute to WM disruptions. IHD-related WM disruptions may be favorably modified by CR. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

7.
Int J Mol Sci ; 24(8)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37108685

RESUMEN

Duchenne muscular dystrophy (DMD) is a neuromuscular disorder caused by dystrophin loss-notably within muscles and the central neurons system. DMD presents as cognitive weakness, progressive skeletal and cardiac muscle degeneration until pre-mature death from cardiac or respiratory failure. Innovative therapies have improved life expectancy; however, this is accompanied by increased late-onset heart failure and emergent cognitive degeneration. Thus, better assessment of dystrophic heart and brain pathophysiology is needed. Chronic inflammation is strongly associated with skeletal and cardiac muscle degeneration; however, neuroinflammation's role is largely unknown in DMD despite being prevalent in other neurodegenerative diseases. Here, we present an inflammatory marker translocator protein (TSPO) positron emission tomography (PET) protocol for in vivo concomitant assessment of immune cell response in hearts and brains of a dystrophin-deficient mouse model [mdx:utrn(+/-)]. Preliminary analysis of whole-body PET imaging using the TSPO radiotracer, [18F]FEPPA in four mdx:utrn(+/-) and six wildtype mice are presented with ex vivo TSPO-immunofluorescence tissue staining. The mdx:utrn(+/-) mice showed significant elevations in heart and brain [18F]FEPPA activity, which correlated with increased ex vivo fluorescence intensity, highlighting the potential of TSPO-PET to simultaneously assess presence of cardiac and neuroinflammation in dystrophic heart and brain, as well as in several organs within a DMD model.


Asunto(s)
Cardiomiopatías , Distrofia Muscular de Duchenne , Animales , Ratones , Distrofina/metabolismo , Ratones Endogámicos mdx , Enfermedades Neuroinflamatorias , Distrofia Muscular de Duchenne/diagnóstico por imagen , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/metabolismo , Cardiomiopatías/metabolismo , Tomografía de Emisión de Positrones , Músculo Esquelético/metabolismo , Modelos Animales de Enfermedad
8.
J Neuroradiol ; 50(3): 315-326, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36738990

RESUMEN

PURPOSE: This systematic review provides a consensus on the clinical feasibility of machine learning (ML) methods for brain PET attenuation correction (AC). Performance of ML-AC were compared to clinical standards. METHODS: Two hundred and eighty studies were identified through electronic searches of brain PET studies published between January 1, 2008, and August 1, 2022. Reported outcomes for image quality, tissue classification performance, regional and global bias were extracted to evaluate ML-AC performance. Methodological quality of included studies and the quality of evidence of analysed outcomes were assessed using QUADAS-2 and GRADE, respectively. RESULTS: A total of 19 studies (2371 participants) met the inclusion criteria. Overall, the global bias of ML methods was 0.76 ± 1.2%. For image quality, the relative mean square error (RMSE) was 0.20 ± 0.4 while for tissues classification, the Dice similarity coefficient (DSC) for bone/soft tissue/air were 0.82 ± 0.1 / 0.95 ± 0.03 / 0.85 ± 0.14. CONCLUSIONS: In general, ML-AC performance is within acceptable limits for clinical PET imaging. The sparse information on ML-AC robustness and its limited qualitative clinical evaluation may hinder clinical implementation in neuroimaging, especially for PET/MRI or emerging brain PET systems where standard AC approaches are not readily available.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen Multimodal , Humanos , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Aprendizaje Automático , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Neuroimagen , Tomografía de Emisión de Positrones/métodos
9.
Neuroimage ; 256: 119261, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35500806

RESUMEN

Routine clinical use of absolute PET quantification techniques is limited by the need for serial arterial blood sampling for input function and more importantly by the lack of automated pharmacokinetic analysis tools that can be readily implemented in clinic with minimal effort. PET/MRI provides the ability for absolute quantification of PET probes without the need for serial arterial blood sampling using image-derived input functions (IDIFs). Here we introduce caliPER, a modular and scalable software for simplified pharmacokinetic modeling of PET probes with irreversible uptake or binding based on PET/MR IDIFs and Patlak Plot analysis. caliPER generates regional values or parametric maps of net influx rate (Ki) using reconstructed dynamic PET images and anatomical MRI aligned to PET for IDIF vessel delineation. We evaluated the performance of caliPER for blood-free region-based and pixel-wise Patlak analyses of [18F] FDG by comparing caliPER IDIF to serial arterial blood input functions and its application in imaging brain glucose hypometabolism in Frontotemporal dementia. IDIFs corrected for partial volume errors including spill-out and spill-in effects were similar to arterial blood input functions with a general bias of around 6-8%, even for arteries <5 mm. The Ki and cerebral metabolic rate of glucose estimated using caliPER IDIF were similar to estimates using arterial blood sampling (<2%) and within limits of whole brain values reported in literature. Overall, caliPER is a promising tool for irreversible PET tracer quantification and can simplify the ability to perform parametric analysis in clinical settings without the need for blood sampling.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones , Glucosa/metabolismo , Humanos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones/métodos , Programas Informáticos
10.
J Magn Reson Imaging ; 56(4): 1243-1255, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35226390

RESUMEN

BACKGROUND: Quantification of cerebral blood flow (CBF) with [15 O]H2 O-positron emission tomography (PET) requires arterial sampling to measure the input function. This invasive procedure can be avoided by extracting an image-derived input function (IDIF); however, IDIFs are sensitive to partial volume errors due to the limited spatial resolution of PET. PURPOSE: To present an alternative hybrid PET/MR imaging of CBF (PMRFlowIDIF ) that uses phase-contrast (PC) MRI measurements of whole-brain (WB) CBF to calibrate an IDIF extracted from a WB [15 O]H2 O time-activity curve. STUDY TYPE: Technical development and validation. ANIMAL MODEL: Twelve juvenile Duroc pigs (83% female). POPULATION: Thirteen healthy individuals (38% female). FIELD STRENGTH/SEQUENCES: 3 T; gradient-echo PC-MRI. ASSESSMENT: PMRFlowIDIF was validated against PET-only in a porcine model that included arterial sampling. CBF maps were generated by applying PMRFlowIDIF and two previous PMRFlow methods (PC-PET and double integration method [DIM]) to [15 O]H2 O-PET data acquired from healthy individuals. STATISTICAL TESTS: PMRFlow and PET CBF measurements were compared with regression and correlation analyses. Paired t-tests were performed to evaluate differences. Potential biases were assessed using one-sample t-tests. Reliability was assessed by intraclass correlation coefficients. Statistical significance: α  = 0.05. RESULTS: In the animal study, strong agreement was observed between PMRFlowIDIF (average voxel-wise CBF, 58.0 ± 16.9 mL/100 g/min) and PET (63.0 ± 18.9 mL/100 g/min). In the human study, PMRFlowDIM (y = 1.11x - 5.16, R2  = 0.99 ± 0.01) and PMRFlowPC-PET (y = 0.87x + 3.82, R2  = 0.97 ± 0.02) performed similarly to PMRFlowIDIF, and CBF was within the expected range (eg, 49.7 ± 7.2 mL/100 g/min for gray matter). DATA CONCLUSION: Accuracy of PMRFlowIDIF was confirmed in the animal study with the primary source of error attributed to differences in WB CBF measured by PC MRI and PET. In the human study, differences in CBF from PMRFlowIDIF , PMRFlowDIM , and PMRFlowPC-PET were due to the latter two not accounting for blood-borne activity. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Circulación Cerebrovascular , Tomografía de Emisión de Positrones , Animales , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Radioisótopos de Oxígeno , Tomografía de Emisión de Positrones/métodos , Reproducibilidad de los Resultados , Porcinos
11.
J Psychiatry Neurosci ; 47(3): E197-E208, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35654450

RESUMEN

BACKGROUND: Major depressive disorder (MDD) is a debilitating mental illness that has been linked to increases in markers of inflammation, as well as to changes in brain functional and structural connectivity, particularly between the insula and the subgenual anterior cingulate cortex (sgACC). In this study, we directly related inflammation and dysconnectivity in treatment-resistant MDD by concurrently measuring the following: microglial activity with [18F]N-2-(fluoroethoxyl)benzyl-N-(4phenoxypyridin-3-yl)acetamide ([18F]FEPPA) positron emission tomography (PET); the severity of MDD; and functional or structural connectivity among insula or sgACC nodes. METHODS: Twelve patients with treatment-resistant MDD (8 female, 4 male; mean age ± standard deviation 54.9 ± 4.5 years and 23 healthy controls (11 female, 12 male; 60.3 ± 8.5 years) completed a hybrid [18F]FEPPA PET and MRI acquisition. From these, we extracted relative standardized uptake values for [18F]FEPPA activity and Pearson r-to-z scores representing functional connectivity from our regions of interest. We extracted diffusion tensor imaging metrics from the cingulum bundle, a key white matter bundle in MDD. We performed regressions to relate microglial activity with functional connectivity, structural connectivity and scores on the 17-item Hamilton Depression Rating Scale. RESULTS: We found significantly increased [18F]FEPPA uptake in the left sgACC in patients with treatment-resistant MDD compared to healthy controls. Patients with MDD also had a reduction in connectivity between the sgACC and the insula. The [18F]FEPPA uptake in the left sgACC was significantly related to functional connectivity with the insula, and to the structural connectivity of the cingulum bundle. [18F]FEPPA uptake also predicted scores on the Hamilton Depression Rating Scale.Limitations: A relatively small sample size, lack of functional task data and concomitant medication use may have affected our findings. CONCLUSION: We present preliminary evidence linking a network-level dysfunction relevant to the pathophysiology of depression and related to increased microglial activity in MDD.


Asunto(s)
Trastorno Depresivo Mayor , Imagen de Difusión Tensora , Femenino , Giro del Cíngulo/diagnóstico por imagen , Humanos , Inflamación , Masculino , Microglía
12.
Alzheimers Dement ; 18(4): 790-809, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34569714

RESUMEN

In tandem with the ever-increasing aging population in low and middle-income countries, the burden of dementia is rising on the African continent. Dementia prevalence varies from 2.3% to 20.0% and incidence rates are 13.3 per 1000 person-years with increasing mortality in parts of rapidly transforming Africa. Differences in nutrition, cardiovascular factors, comorbidities, infections, mortality, and detection likely contribute to lower incidence. Alzheimer's disease, vascular dementia, and human immunodeficiency virus/acquired immunodeficiency syndrome-associated neurocognitive disorders are the most common dementia subtypes. Comprehensive longitudinal studies with robust methodology and regional coverage would provide more reliable information. The apolipoprotein E (APOE) ε4 allele is most studied but has shown differential effects within African ancestry compared to Caucasian. More candidate gene and genome-wide association studies are needed to relate to dementia phenotypes. Validated culture-sensitive cognitive tools not influenced by education and language differences are critically needed for implementation across multidisciplinary groupings such as the proposed African Dementia Consortium.


Asunto(s)
Enfermedad de Alzheimer , Demencia Vascular , Demencia , Anciano , Enfermedad de Alzheimer/genética , Apolipoproteína E4/genética , Demencia/epidemiología , Demencia/genética , Demencia Vascular/complicaciones , Estudio de Asociación del Genoma Completo , Genotipo , Humanos
13.
Adv Exp Med Biol ; 1269: 203-208, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33966218

RESUMEN

This is the first multimodal study of cerebral tissue metabolism and perfusion post-hypoxic-ischaemic (HI) brain injury using broadband near-infrared spectroscopy (bNIRS), diffuse correlation spectroscopy (DCS), positron emission tomography (PET) and magnetic resonance spectroscopy (MRS). In seven piglet preclinical models of neonatal HI, we measured cerebral tissue saturation (StO2), cerebral blood flow (CBF), cerebral oxygen metabolism (CMRO2), changes in the mitochondrial oxidation state of cytochrome c oxidase (oxCCO), cerebral glucose metabolism (CMRglc) and tissue biochemistry (Lac+Thr/tNAA). At baseline, the parameters measured in the piglets that experience HI (not controls) were 64 ± 6% StO2, 35 ± 11 ml/100 g/min CBF and 2.0 ± 0.4 µmol/100 g/min CMRO2. After HI, the parameters measured were 68 ± 6% StO2, 35 ± 6 ml/100 g/min CBF, 1.3 ± 0.1 µmol/100 g/min CMRO2, 0.4 ± 0.2 Lac+Thr/tNAA and 9.5 ± 2.0 CMRglc. This study demonstrates the capacity of a multimodal set-up to interrogate the pathophysiology of HIE using a combination of optical methods, MRS, and PET.


Asunto(s)
Hipoxia-Isquemia Encefálica , Animales , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Hipoxia-Isquemia Encefálica/diagnóstico por imagen , Oxígeno , Consumo de Oxígeno , Perfusión , Espectroscopía Infrarroja Corta , Porcinos
14.
Neuroimage ; 219: 117031, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32526385

RESUMEN

Arterial spin labeling (ASL) has undergone significant development since its inception, with a focus on improving standardization and reproducibility of its acquisition and quantification. In a community-wide effort towards robust and reproducible clinical ASL image processing, we developed the software package ExploreASL, allowing standardized analyses across centers and scanners. The procedures used in ExploreASL capitalize on published image processing advancements and address the challenges of multi-center datasets with scanner-specific processing and artifact reduction to limit patient exclusion. ExploreASL is self-contained, written in MATLAB and based on Statistical Parameter Mapping (SPM) and runs on multiple operating systems. To facilitate collaboration and data-exchange, the toolbox follows several standards and recommendations for data structure, provenance, and best analysis practice. ExploreASL was iteratively refined and tested in the analysis of >10,000 ASL scans using different pulse-sequences in a variety of clinical populations, resulting in four processing modules: Import, Structural, ASL, and Population that perform tasks, respectively, for data curation, structural and ASL image processing and quality control, and finally preparing the results for statistical analyses on both single-subject and group level. We illustrate ExploreASL processing results from three cohorts: perinatally HIV-infected children, healthy adults, and elderly at risk for neurodegenerative disease. We show the reproducibility for each cohort when processed at different centers with different operating systems and MATLAB versions, and its effects on the quantification of gray matter cerebral blood flow. ExploreASL facilitates the standardization of image processing and quality control, allowing the pooling of cohorts which may increase statistical power and discover between-group perfusion differences. Ultimately, this workflow may advance ASL for wider adoption in clinical studies, trials, and practice.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Algoritmos , Circulación Cerebrovascular/fisiología , Humanos , Reproducibilidad de los Resultados , Relación Señal-Ruido , Programas Informáticos , Marcadores de Spin
15.
Neuroimage ; 147: 346-359, 2017 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-27988322

RESUMEN

AIM: To accurately quantify the radioactivity concentration measured by PET, emission data need to be corrected for photon attenuation; however, the MRI signal cannot easily be converted into attenuation values, making attenuation correction (AC) in PET/MRI challenging. In order to further improve the current vendor-implemented MR-AC methods for absolute quantification, a number of prototype methods have been proposed in the literature. These can be categorized into three types: template/atlas-based, segmentation-based, and reconstruction-based. These proposed methods in general demonstrated improvements compared to vendor-implemented AC, and many studies report deviations in PET uptake after AC of only a few percent from a gold standard CT-AC. Using a unified quantitative evaluation with identical metrics, subject cohort, and common CT-based reference, the aims of this study were to evaluate a selection of novel methods proposed in the literature, and identify the ones suitable for clinical use. METHODS: In total, 11 AC methods were evaluated: two vendor-implemented (MR-ACDIXON and MR-ACUTE), five based on template/atlas information (MR-ACSEGBONE (Koesters et al., 2016), MR-ACONTARIO (Anazodo et al., 2014), MR-ACBOSTON (Izquierdo-Garcia et al., 2014), MR-ACUCL (Burgos et al., 2014), and MR-ACMAXPROB (Merida et al., 2015)), one based on simultaneous reconstruction of attenuation and emission (MR-ACMLAA (Benoit et al., 2015)), and three based on image-segmentation (MR-ACMUNICH (Cabello et al., 2015), MR-ACCAR-RiDR (Juttukonda et al., 2015), and MR-ACRESOLUTE (Ladefoged et al., 2015)). We selected 359 subjects who were scanned using one of the following radiotracers: [18F]FDG (210), [11C]PiB (51), and [18F]florbetapir (98). The comparison to AC with a gold standard CT was performed both globally and regionally, with a special focus on robustness and outlier analysis. RESULTS: The average performance in PET tracer uptake was within ±5% of CT for all of the proposed methods, with the average±SD global percentage bias in PET FDG uptake for each method being: MR-ACDIXON (-11.3±3.5)%, MR-ACUTE (-5.7±2.0)%, MR-ACONTARIO (-4.3±3.6)%, MR-ACMUNICH (3.7±2.1)%, MR-ACMLAA (-1.9±2.6)%, MR-ACSEGBONE (-1.7±3.6)%, MR-ACUCL (0.8±1.2)%, MR-ACCAR-RiDR (-0.4±1.9)%, MR-ACMAXPROB (-0.4±1.6)%, MR-ACBOSTON (-0.3±1.8)%, and MR-ACRESOLUTE (0.3±1.7)%, ordered by average bias. The overall best performing methods (MR-ACBOSTON, MR-ACMAXPROB, MR-ACRESOLUTE and MR-ACUCL, ordered alphabetically) showed regional average errors within ±3% of PET with CT-AC in all regions of the brain with FDG, and the same four methods, as well as MR-ACCAR-RiDR, showed that for 95% of the patients, 95% of brain voxels had an uptake that deviated by less than 15% from the reference. Comparable performance was obtained with PiB and florbetapir. CONCLUSIONS: All of the proposed novel methods have an average global performance within likely acceptable limits (±5% of CT-based reference), and the main difference among the methods was found in the robustness, outlier analysis, and clinical feasibility. Overall, the best performing methods were MR-ACBOSTON, MR-ACMAXPROB, MR-ACRESOLUTE and MR-ACUCL, ordered alphabetically. These methods all minimized the number of outliers, standard deviation, and average global and local error. The methods MR-ACMUNICH and MR-ACCAR-RiDR were both within acceptable quantitative limits, so these methods should be considered if processing time is a factor. The method MR-ACSEGBONE also demonstrates promising results, and performs well within the likely acceptable quantitative limits. For clinical routine scans where processing time can be a key factor, this vendor-provided solution currently outperforms most methods. With the performance of the methods presented here, it may be concluded that the challenge of improving the accuracy of MR-AC in adult brains with normal anatomy has been solved to a quantitatively acceptable degree, which is smaller than the quantification reproducibility in PET imaging.


Asunto(s)
Encéfalo/diagnóstico por imagen , Disfunción Cognitiva/diagnóstico por imagen , Demencia/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Imagen por Resonancia Magnética/normas , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones/normas , Radiofármacos , Adulto Joven
18.
Science ; 384(6696): 623-624, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38723100

RESUMEN

Low-field magnetic resonance imaging can be engineered for widespread point-of-care diagnostics.


Asunto(s)
Imagen por Resonancia Magnética , Sistemas de Atención de Punto , Humanos
19.
Med Image Anal ; 95: 103184, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38723320

RESUMEN

Synthesizing 7T Susceptibility Weighted Imaging (SWI) from 3T SWI could offer significant clinical benefits by combining the high sensitivity of 7T SWI for neurological disorders with the widespread availability of 3T SWI in diagnostic routines. Although methods exist for synthesizing 7T Magnetic Resonance Imaging (MRI), they primarily focus on traditional MRI modalities like T1-weighted imaging, rather than SWI. SWI poses unique challenges, including limited data availability and the invisibility of certain tissues in individual 3T SWI slices. To address these challenges, we propose a Self-supervised Anatomical Continuity Enhancement (SACE) network to synthesize 7T SWI from 3T SWI using plentiful 3T SWI data and limited 3T-7T paired data. The SACE employs two specifically designed pretext tasks to utilize low-level representations from abundant 3T SWI data for assisting 7T SWI synthesis in a downstream task with limited paired data. One pretext task emphasizes input-specific morphology by balancing the elimination of redundant patterns with the preservation of essential morphology, preventing the blurring of synthetic 7T SWI images. The other task improves the synthesis of tissues that are invisible in a single 3T SWI slice by aligning adjacent slices with the current slice and predicting their difference fields. The downstream task innovatively combines clinical knowledge with brain substructure diagrams to selectively enhance clinically relevant features. When evaluated on a dataset comprising 97 cases (5495 slices), the proposed method achieved a Peak Signal-to-Noise Ratio (PSNR) of 23.05 dB and a Structural Similarity Index (SSIM) of 0.688. Due to the absence of specific methods for 7T SWI, our method was compared with existing enhancement techniques for general 7T MRI synthesis, outperforming these techniques in the context of 7T SWI synthesis. Clinical evaluations have shown that our synthetic 7T SWI is clinically effective, demonstrating its potential as a clinical tool.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Encéfalo/diagnóstico por imagen , Algoritmos , Interpretación de Imagen Asistida por Computador/métodos
20.
EJNMMI Phys ; 11(1): 11, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38285319

RESUMEN

BACKGROUND: Quantification of the cerebral metabolic rate of glucose (CMRGlu) by dynamic [18F]FDG PET requires invasive arterial sampling. Alternatives to using an arterial input function (AIF) include the simultaneous estimation (SIME) approach, which models the image-derived input function (IDIF) by a series of exponentials with coefficients obtained by fitting time activity curves (TACs) from multiple volumes-of-interest. A limitation of SIME is the assumption that the input function can be modelled accurately by a series of exponentials. Alternatively, we propose a SIME approach based on the two-tissue compartment model to extract a high signal-to-noise ratio (SNR) model-derived input function (MDIF) from the whole-brain TAC. The purpose of this study is to present the MDIF approach and its implementation in the analysis of animal and human data. METHODS: Simulations were performed to assess the accuracy of the MDIF approach. Animal experiments were conducted to compare derived MDIFs to measured AIFs (n = 5). Using dynamic [18F]FDG PET data from neurologically healthy volunteers (n = 18), the MDIF method was compared to the original SIME-IDIF. Lastly, the feasibility of extracting parametric images was investigated by implementing a variational Bayesian parameter estimation approach. RESULTS: Simulations demonstrated that the MDIF can be accurately extracted from a whole-brain TAC. Good agreement between MDIFs and measured AIFs was found in the animal experiments. Similarly, the MDIF-to-IDIF area-under-the-curve ratio from the human data was 1.02 ± 0.08, resulting in good agreement in grey matter CMRGlu: 24.5 ± 3.6 and 23.9 ± 3.2 mL/100 g/min for MDIF and IDIF, respectively. The MDIF method proved superior in characterizing the first pass of [18F]FDG. Groupwise parametric images obtained with the MDIF showed the expected spatial patterns. CONCLUSIONS: A model-driven SIME method was proposed to derive high SNR input functions. Its potential was demonstrated by the good agreement between MDIFs and AIFs in animal experiments. In addition, CMRGlu estimates obtained in the human study agreed to literature values. The MDIF approach requires fewer fitting parameters than the original SIME method and has the advantage that it can model the shape of any input function. In turn, the high SNR of the MDIFs has the potential to facilitate the extraction of voxelwise parameters when combined with robust parameter estimation methods such as the variational Bayesian approach.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA