Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Gastrointest Endosc ; 95(1): 80-89, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34352256

RESUMEN

BACKGROUND AND AIMS: Stent misdeployment (SM) has hindered the dissemination of EUS-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction (GOO) management. We aimed to provide a classification system for SM during EUS-GE and study clinical outcomes and management accordingly. METHODS: This is a retrospective study involving 16 tertiary care centers (8 in the United States, 8 in Europe) from March 2015 to December 2020. Patients who developed SM during EUS-GE for GOO were included. We propose classifying SM into 4 types. The primary outcome was rate and severity of SM (per American Society for Gastrointestinal Endoscopy lexicon), whereas secondary outcomes were clinical outcomes and management of dislodgement according to the SM classification type, in addition to salvage management of GOO after SM. RESULTS: From 467 EUS-GEs performed for GOO during the study period, SM occurred in 46 patients (9.85%). Most SMs (73.2%) occurred during the first 13 EUS-GE cases by the performing operators. SM was graded as mild (n = 28, 60.9%), moderate (n = 11, 23.9%), severe (n = 6, 13.0%), or fatal (n = 1, 2.2%), with 5 patients (10.9%) requiring surgical intervention. Type I SM was the most common (n = 29, 63.1%), followed by type II (n = 14, 30.4%), type IV (n = 2, 4.3%), and type III (n = 1, 2.2%). Type I SM was more frequently rated as mild compared with type II SM (75.9% vs 42.9%, P = .04) despite an equivalent rate of surgical repair (10.3% vs 7.1%, P = .7). Overall, 4 patients (8.7%) required an intensive care unit stay (median, 2.5 days). The median length of stay was 4 days after SM. CONCLUSIONS: Although SM is not infrequent during EUS-GE, most are type I, mild/moderate in severity, and can be managed endoscopically with a surgical intervention rate of approximately 11%.


Asunto(s)
Endosonografía , Obstrucción de la Salida Gástrica , Obstrucción de la Salida Gástrica/cirugía , Gastroenterostomía , Humanos , Estudios Retrospectivos , Stents
2.
Endoscopy ; 52(3): 211-219, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32000275

RESUMEN

BACKGROUNDS: Endoscopic ultrasound (EUS)-guided placement of lumen-apposing metal stents (LAMSs) has gained popularity for the treatment of pancreatic walled-off necrosis (WON). We compared the 20-mm and 15-mm LAMSs for the treatment of symptomatic WON in terms of clinical success and adverse events. METHODS: We conducted a retrospective, case-matched study of 306 adults at 22 tertiary centers from 04/2014 to 10/2018. A total of 102 patients with symptomatic WON who underwent drainage with 20-mm LAMS (cases) and 204 patients who underwent drainage with 15-mm LAMS (controls) were matched by age, sex, and drainage approach. Conditional logistic regression analysis was performed to compare clinical success (resolution of WON on follow-up imaging without reintervention) and adverse events (according to American Society for Gastrointestinal Endoscopy criteria). RESULTS: Clinical success was achieved in 92.2 % of patients with 20-mm LAMS and 91.7 % of patients with 15-mm LAMS (odds ratio 0.92; P = 0.91). Patients with 20-mm LAMS underwent fewer direct endoscopic necrosectomy (DEN) sessions (mean 1.3 vs. 2.1; P < 0.001), despite having larger WON collections (transverse axis 118.2 vs. 101.9 mm, P = 0.003; anteroposterior axis 95.9 vs. 80.1 mm, P = 0.01). There was no difference in overall adverse events (21.6 % vs. 15.2 %; P = 0.72) and bleeding events (4.9 % vs. 3.4 %; P = 0.54) between the 20-mm and 15-mm LAMS groups, respectively. CONCLUSIONS: The 20-mm LAMS showed comparable clinical success and safety profile to the 15-mm LAMS, with the need for fewer DEN sessions for WON resolution.


Asunto(s)
Drenaje , Stents , Adulto , Humanos , Necrosis/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA