Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Reprod Med Biol ; 10(2): 97-103, 2011 06.
Artículo en Inglés | MEDLINE | ID: mdl-29662353

RESUMEN

Purpose: Zona pellucida (ZP)-free eggs are often used for studies such as evaluating the interaction of sperm-oolemma. To acquire ZP-free eggs, the most commonly used methods employ acidified Tyrode's solution, enzymatic digestion with a trypsin-like enzyme, or mechanical methods using micropipettes. However, acidified Tyrode's solution and trypsin-like enzymes often damage the oolemma, especially when many eggs are treated at once for mass sample analyses. The mechanical method requires skill, and it is time-consuming to prepare many ZP-free eggs. Therefore, in this study, to establish an easy, reliable method for preparing ZP-free eggs, we examined the ZP digestion method originally reported by Zuccotti et al. (J Reprod Fertil 93:515-520, 1991) that uses collagenase. Methods: Mouse unfertilized eggs were treated with collagenase and acidified Tyrode's solution to compare the ZP-free rates, the effect on the oolemma, and the two-cell development rates of ZP-free eggs by in vitro fertilization. The effects on the oolemma were gauged by observing the polarity of the transmembrane protein localization of enhanced green fluorescence protein tagged CD9 protein (CD9-EGFP) and using differential interference contrast microscopy. Results: Collagenase removed the ZP and the cumulus cells from the cumulus oocyte complex. The collagenase method had no influence on the localization of CD9-EGFP, resulting in a high two-cell development rate. Additionally, the collagenase method could exclude low quality eggs with hardened ZP, since collagenase could not digest the hardened ZP. Conclusions: The one-step collagenase method is an easy preparation method for large numbers of high-quality ZP-free eggs.

2.
Nihon Hotetsu Shika Gakkai Zasshi ; 52(2): 220-3, 2008 Apr.
Artículo en Japonés | MEDLINE | ID: mdl-18467795

RESUMEN

PATIENT: A 69-years-old edentulous male patient visited with a chief complaint of repeated fracture of a lower complete denture. A new denture was fabricated to improve the denture base rigidity and to modify the shape of the polished surface and position of the artificial teeth arrangement. DISCUSSION: It seemed that the lower complete denture was broken repeatedly because the thickness in the central part was insubstantial there was not a reinforcement metal structure, and possibly the occlusal force was strong. By Piezography method, we attempted to assemble the components requisite to improve strength including reinforcement of the metal structure. CONCLUSION: In this case, a lower complete denture was successfully produced with high rigidity that might not obstruct the denture stability, by applying Piezography.


Asunto(s)
Técnica de Impresión Dental , Diseño de Dentadura , Dentadura Completa , Anciano , Materiales de Impresión Dental , Rebasado de Dentaduras , Humanos , Masculino , Mandíbula/anatomía & histología , Maxilar/anatomía & histología , Diente Artificial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA