Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 47(3): 383-391, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38348921

RESUMEN

OBJECTIVE: The presence of cannon A waves, the so called "frog sign", has traditionally been considered diagnostic of atrioventricular nodal re-entrant tachycardia (AVNRT). Nevertheless, it has never been systematically evaluated. The aim of this study is to assess the independent diagnostic utility of cannon A waves in the differential diagnosis of supraventricular tachycardias (SVTs). METHODS: We prospectively included 100 patients who underwent an electrophysiology (EP) study for SVT. The right jugular venous pulse was recorded during the study. In 61 patients, invasive central venous pressure (CVP) was registered as well. CVP increase is thought to be related with the timing between atria and ventricle depolarization; two groups were prespecified, the short VA interval tachycardias (including typical AVNRT and atrioventricular reciprocating tachycardia (AVRT) mediated by a septal accessory pathway) and the long VA interval tachycardias (including atypical AVNRT and AVRT mediated by a left free wall accessory pathway). RESULTS: The relationship between cannon A waves and AVNRT did not reach the statistical significance (OR: 3.01; p = .058); On the other hand, it was clearly associated with the final diagnosis of a short VA interval tachycardia (OR: 10.21; p < .001). CVP increase showed an inversely proportional relationship with the VA interval during tachycardia (b = -.020; p < .001). CVP increase was larger in cases of AVNRT (4.0 mmHg vs. 1.2 mmHg; p < .001) and short VA interval tachycardias (3.9 mmHg vs. 1.2 mmHg; p < .001). CONCLUSION: The presence of cannon A waves is associated with the final diagnosis of short VA interval tachycardias.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Fascículo Atrioventricular , Taquicardia Ventricular/diagnóstico , Atrios Cardíacos , Diagnóstico Diferencial , Electrocardiografía
2.
Rev. esp. cardiol. (Ed. impr.) ; 77(5): 362-369, mayo 2024. ilus, tab, graf
Artículo en Español | IBECS (España) | ID: ibc-JHG-67

RESUMEN

Introducción y objetivos: La experiencia con el desfibrilador automático implantable subcutáneo (DAI-SC) en pacientes pediátricos aún es reducida. El objetivo de este estudio es determinar la incidencia de complicaciones en pacientes pediátricos de nuestro centro en función del tipo de DAI y del tamaño del paciente.MétodosSe incluyó a pacientes menores de 18 años que recibieron un DAI-SC desde 2016 y pacientes contemporáneos (desde 2014) que recibieron un DAI transvenoso (DAI-TV). El evento principal fue el combinado de complicaciones y descargas inapropiadas.ResultadosSe implantó un DAI-SC a 26 pacientes (edad, 14 [intervalo, 5-17] años; índice de masa corporal [IMC], 20,2). De ellos, 23 (88%) fueron implantes intermusculares y el resto, en subserrato, 24 (92%) con 2 incisiones. Se programaron 2 zonas en todos los pacientes: condicional a 230 (220-230) lpm y de choque a 250 lpm. El grupo de DAI-TV incluyó a 19 pacientes (edad, 11 [5-16] años; IMC, 19,2; el 79% monocamerales). La supervivencia libre del evento principal a 5 años fue el 80% de los pacientes con DAI-SC y el 63% del grupo con DAI-TV (p=0,54); la de descargas inapropiadas fue similar (el 85 frente al 89%; p=0,86), mientras que la de complicaciones fue mayor en el grupo de DAI-SC (el 96 frente al 57%; cloglog p=0.016). En el grupo de DAI-SC no hubo fallo de la terapia ni mayores complicaciones con un IMC ≤ 20.ConclusionesCon las técnicas de implante y programación actuales, el DAI-SC es eficaz y seguro en pacientes pediátricos, con similares descargas inapropiadas y menos complicaciones a corto y medio plazo que el DAI-TV. (AU)


Introduction and objectives: There is limited evidence regarding the use of subcutaneous implantable cardioverter-defibrillators (S-ICD) in pediatric patients. The aim of this study was to determine the incidence of complications in these patients at our center, according to the type of ICD and patient size.MethodsWe included all patients aged<18 years who received an S-ICD since 2016 at our center. As a control group, we also included contemporary patients (since 2014) who received a transvenous ICD (TV-ICD). The primary endpoint was a composite of complications and inappropriate shocks.ResultsA total of 26 patients received an S-ICD (median age, 14 [5-17] years; body mass index [BMI], 20.2 kg/m2). Implantation was intermuscular in 23 patients (88%) and subserratus in the remainder. Two incisions were used in 24 patients (92%). In all patients, 2 zones were programmed: a conditional zone set at 230 (220-230) bpm, and a shock zone set at 250 bpm. Nineteen patients received a TV-ICD (median age, 11 [range, 5-16] years; BMI, 19.2 kg/m2, 79% single-chamber). Survival free from the primary endpoint at 5 years was 80% in the S-ICD group and 63% in the TV-ICD group (P=.54). Survival free from inappropriate shocks was similar (85% vs 89%, P=.86), while survival free from complications was higher in the S-ICD group (96% vs 57%, cloglogP=.016). There were no therapy failures in the S-ICD group, and no increased complication rates were observed in patients with BMI ≤ 20 kg/m2.ConclusionsWith contemporary implantation techniques and programming, S-ICD is a safe and effective therapy in pediatric patients. The number of inappropriate shocks is similar to TV-ICD, with fewer short- and mid-term complications. (AU)


Asunto(s)
Humanos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios de Seguimiento , Incidencia
3.
Rev. esp. cardiol. (Ed. impr.) ; 74(4): 296-302, Abr. 2021. tab, graf
Artículo en Español | IBECS (España) | ID: ibc-232234

RESUMEN

Introducción y objetivos El estudio ADVANCE III mostró una reducción de terapias del desfibrilador automático implantable (DAI) con el empleo de tiempos de detección de arritmia prolongados. Se describe la adopción y el impacto de dicha estrategia en la incidencia de terapias del DAI. Métodos Estudio observacional retrospectivo de pacientes con implante de DAI Medtronic (2005-2016) en un registro multicéntrico (UMBRELLA-NCT01561144). Se describe la evolución de la adopción de programación ADVANCE en relación con: publicación del estudio, implementación de una campaña de formación y publicación de un consenso de expertos. Se identificaron con regresión logística los predictores de la adopción. Se comparó la incidencia de terapias en pacientes con y sin programación ADVANCE estimando la razón de tasas de incidencia ajustada (RTIa) mediante regresión binomial negativa. Resultados Se incluyó a 3.528 pacientes. Se utilizó la estrategia ADVANCE en el 20% del total y el 44% al final del estudio. La adopción se incrementó tras publicarse el estudio ADVANCE, y en menor grado tras la campaña de formación y consenso de expertos. Predictores de la adopción: DAI con detección nominal 30/40 (ORa=4,4; IC95%, 3,5-5,4), implantador electrofisiólogo (ORa=1,7; IC95%, 1,4-2,2) y prevención secundaria (ORa=3,2; IC95%, 2,6-3,9). El implante de DAI bicameral (ORa=0,6; IC95%, 0,5-0,8) o tricameral (ORa=0,5; IC95%, 0,4-0,7) se asoció con menor adopción. La programación ADVANCE se asoció con reducción de terapias totales (RTIa=0,77; IC95%, 0,69-0,86) y choques inapropiados (RTIa=0,66; IC95%, 0,52-0,85). Conclusiones La adopción de la programación ADVANCE es poco amplia y puede mejorarse mediante una adecuada selección de los parámetros nominales. Emplearla se asocia con una reducción de las terapias del DAI. (AU)


Introduction and objectives The ADVANCE III trial showed that a delayed-detection strategy reduces implantable cardioverter-defibrillator (ICD) therapies. Here, we describe the adherence to and predictors of ADVANCE adoption and compare ICD therapy rates between patients with and without ADVANCE programming. Methods This observational retrospective study analyzed patients implanted with Medtronic ICDs included from 2005 to 2016 in a Spanish national multicenter registry (UMBRELLA database; ClinicalTrials.gov, NCT01561144). Changes in ADVANCE programming adoption were described in relation to a) publication of the ADVANCE trial, b) implementation of an “ADVANCE awareness” campaign, and c) publication of an expert consensus statement. Multivariate logistic regression identified predictors of adoption. Therapy incidence rates were compared between groups by estimating the adjusted incidence rate ratio (aIRR) using negative binomial regression. Results A total of 3528 patients were included. An ADVANCE strategy was used in 20% overall and in 44% at the end of the study. ADVANCE III adoption increased after trial publication, with less growth after an “ADVANCE awareness” campaign and after expert consensus statement publication. Predictors of ADVANCE adoption were as follows: ICD device with a nominal number of intervals to detect 30/40 (aOR, 4.4; 95%CI, 3.5-5.4), implantation by an electrophysiologist (aOR, 1.7; 95%CI, 1.4-2.2), and secondary prevention (aOR, 3.2; 95%CI, 2.6-3.9). Dual-chamber ICDs (aOR, 0.6; 95%CI, 0.5-0.8) and cardiac resynchronization-defibrillators (aOR, 0.5; 95%CI, 0.4-0.7) were associated with lower adoption. ADVANCE programming was associated with reduced total therapy burden (aIRR, 0.77; 95%CI, 0.69-0.86) and fewer inappropriate shocks (aIRR, 0.66; 95%CI, 0.52-0.85). Conclusions ADVANCE adoption remains modest and can be improved through evidence-driven selection of nominal ICD settings. ... (AU)


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Desfibriladores Implantables , Medicina de Precisión , Estudios Retrospectivos , Epidemiología Descriptiva
4.
Arch. cardiol. Méx ; 90(4): 379-388, Oct.-Dec. 2020. tab, graf
Artículo en Español | LILACS | ID: biblio-1152811

RESUMEN

Resumen Introducción y objetivos: La tormenta eléctrica (TE) se caracteriza por episodios repetidos de taquicardia ventricular o fibrilación ventricular relacionados con mal pronóstico a corto y largo plazos. El objetivo fue evaluar la prevalencia, resultados y supervivencia de los pacientes sometidos a tratamiento intervencionista por TE en un centro de referencia. Métodos: Estudio unicéntrico, observacional y retrospectivo. Se revisaron los procedimientos de ablación por TE y se evaluaron las características basales de los pacientes, tipo de procedimiento, mortalidad total, recurrencia de arritmia, mortalidad cardiovascular y necesidad de trasplante. Resultados: Desde enero de 2009 hasta diciembre de 2016 se realizaron 67 procedimientos (38% de complejos: 19% de ablación endoepicárdica, 7.5% de crioablación epicárdica quirúrgica, 3% de simpatectomía, 3% de inyección coronaria con alcohol; 6% de apoyo con oxigenación con membrana extracorpórea) en 41 pacientes (61% de causa isquémica) por TE. La mortalidad intraprocedimiento fue del 1.5%. La mediana de seguimiento fue de 23.5 meses (RIQ, 14.2-52.7). Tras el primer ingreso por TE (uno o varios procedimientos), la mortalidad a un año fue de 9.8%. La incidencia acumulada de trasplante cardiaco por TE fue de 2.4%. En el análisis multivariado, el riesgo de recurrencias arrítmicas o muerte por cualquier causa fue significativamente mayor en pacientes con arritmias clínicas inducibles (HR, 9.03; p = 0.017). Conclusiones: El tratamiento de pacientes con TE, instituido en un centro de referencia y con experiencia, se relacionó con una tasa baja de recurrencia y supervivencia elevada, con una tasa de trasplante cardiaco por TE muy baja. Ante una recurrencia temprana es recomendable practicar un nuevo procedimiento durante el ingreso.


Abstract Introduction and objective: Electrical storm (ES) is characterized by repeated episodes of ventricular tachycardia or ventricular fibrillation, with poor short and long term prognosis. Our objective was to evaluate the prevalence, results of interventional treatment and survival of patients undergoing interventional treatment for ES in our center. Methods: Retrospective, unicentric and observational study. ES ablation procedures were revised and data regarding baseline characteristics of the patients, type of procedure, total mortality, recurrence of arrhythmia, cardiovascular mortality and the need for transplantation were evaluated. Results: From January 2009 to December 2016, 67 procedures (38% complex procedures: 19% epicardial ablation, 7.5% surgical epicardial crioablation, 3% simpatectomy, 3% coronary alcohol injection, 6% extracorporeal membrane oxygenation support) were performed in 41 patients (61% Ischemic etiology) due to ES. Intraprocedural mortality was 1.5%. The median follow-up was 23.5 months (IQR [14.2-52.7]). After the first admission for ES (one or several procedures), 1-year mortality was 9.8%. The cumulative incidence of cardiac transplantation was 2.4%. The risk of arrhythmic recurrences or death was significantly higher in patients with inducible clinical arrhythmias after ablation (HR: 9.03, p = 0.017). Conclusions: The treatment of patients with ES, performed in a reference center, allows obtaining good rates of recurrence and survival, with very low rates of cardiac transplantation for ES. In the presence of an early recurrence, it is advisable to perform a new procedure during admission.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Fibrilación Ventricular/cirugía , Taquicardia Ventricular/cirugía , Ablación por Catéter/métodos , Pronóstico , Recurrencia , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/mortalidad , Tasa de Supervivencia , Estudios Retrospectivos , Estudios de Seguimiento , Trasplante de Corazón/estadística & datos numéricos , Taquicardia Ventricular/mortalidad , México
5.
Rev. esp. cardiol. (Ed. impr.) ; 71(10): 794-800, oct. 2018. tab, graf
Artículo en Español | IBECS (España) | ID: ibc-178821

RESUMEN

Introducción y objetivos: La ablación con catéter es un método para tratar arritmias en población pediátrica indicada en un creciente número de casos. Hay poca evidencia sobre la experiencia en estos procedimientos en España. El objetivo es describir las características y los resultados de una serie contemporánea de un hospital terciario de referencia nacional. Métodos: Se revisaron los procedimientos de ablación realizados entre 2004 y 2016 en menores de 17 años en el momento de la indicación. Se analizaron características clínicas, metodología de la ablación y resultados agudos y a largo plazo. Resultados: Se realizaron 291 procedimientos en 224 pacientes (mediana de edad, 12,2 años; el 60% varones). El 46% de los pacientes venían derivados desde otras comunidades autónomas. Los sustratos más frecuentemente abordados fueron las vías accesorias (VAC) (el 70,2%; más del 50% septales) y la taquicardia intranodular (TIN) (15,8%). El 16,8% presentaba cardiopatía congénita, familiar o adquirida. El 35,5% de los casos se realizaron con crioablación. El éxito agudo general de los procedimientos primarios fue del 93,5% (el 93,8% en las VAC y el 100% en las TIN). Se repitieron procedimientos por recurrencia en el 18,9% de los casos, con un éxito acumulado del 98,4% (el 99,3% en las VAC y el 100% en las TIN). Se registró un bloqueo auriculoventricular completo (0,37%), sin otras complicaciones mayores. Conclusiones: El elevado porcentaje de éxito con mínimas complicaciones en una serie con alto nivel de complejidad reproduce los resultados publicados en otros países y refrenda el uso de la ablación con catéter en población pediátrica en centros especializados de referencia


Introduction and objectives: Catheter ablation has become the treatment of choice in an increasing number of arrhythmias in children and adolescents. There is still limited evidence of its use at a national level in Spain. The aim was to describe the characteristics and results of a modern monocentric series form a referral tertiary care centre. Methods: Retrospective register of invasive procedures between 2004 and 2016 performed in patients under 17 years and recorded clinical characteristic, ablation methodology and acute and chronic results of the procedure. Results: A total of 291 procedures in 224 patients were included. Median age was 12.2 years, 60% male. Overall, 46% patients were referred from other autonomous communities. The most frequent substrates were accessory pathways (AP) (70.2%, > 50% septal AP localization) and atrioventricular nodal reentrant tachycardia (AVNRT) (15.8%). Congenital and acquired heart disease was frequent (16.8%). Cryoablation was used in 35.5% of the cases. Overall acute success of the primary procedure was 93.5% (AP 93.8%; AVNRT 100%). Redo procedures after recurrence were performed in 18.9% of all substrates, with a long-term cumulative efficacy of 98.4% (AP 99.3%; AVNRT 100%). One (0.37%) serious complication occurred, a case of complete atrioventricular block. Conclusions: Our study replicated previous international reports of high success rates with scarce complications in a high complexity series, confirming the safety and efficacy of pediatric catheter ablation in our environment performed at highly experienced referral centers


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Ablación por Catéter/métodos , Cardiopatías Congénitas/cirugía , Arritmias Cardíacas/cirugía , Taquicardia Atrial Ectópica/cirugía , Arritmias Cardíacas/fisiopatología , Criocirugía/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Sistema de Conducción Cardíaco/cirugía , Atención Terciaria de Salud
11.
Rev. esp. cardiol. (Ed. impr.) ; 72(12): 1020-1030, dic. 2019. tab
Artículo en Español | IBECS (España) | ID: ibc-190766

RESUMEN

Introducción y objetivos: Se describen los resultados en España de la segunda encuesta de la Sociedad Europea de Cardiología sobre terapia de resincronización cardiaca (CRT-Survey II) y se comparan con los de los demás países participantes. Métodos: Pacientes a los que se implantó un dispositivo de terapia de resincronización cardiaca entre octubre de 2015 y diciembre de 2016 en 36 centros participantes. Se recogieron datos sobre las características basales de los pacientes y del implante, y un seguimiento a corto plazo hasta el alta hospitalaria. Resultados: La tasa de éxito del implante fue del 95,9%. La mediana [intervalo intercuartílico] de implantes anuales/centro en España fue significativamente menor que en los demás países participantes: 30 [21-50] frente a 55 [33-100] implantes/año (p=0,00003). En los centros españoles hubo una menor proporción de pacientes de edad ≥ 75 años (el 27,9 frente al 32,4%; p=0,0071), una mayor proporción de pacientes en clase funcional II de la New York Heart Association (el 46,9 frente al 36,9%; p <0,00001) y un mayor porcentaje de pacientes con criterios electrocardiográficos de bloqueo de rama izquierda (el 82,9 frente al 74,6%; p <0,00001). La media de la estancia hospitalaria fue menor en los centros españoles (5,8+/-8,5 frente a 6,4+/-11,6; p <0,00001) y una mayor proporción de pacientes recibieron un cable de ventrículo izquierdo cuadripolar (el 74 frente al 56%; p <0,00001) y fueron seguidos a distancia (el 55,8 frente al 27,7%; p <0,00001). Conclusiones: La encuesta CRT-Survey II muestra que en España hay una menor proporción de pacientes de 75 o más años que reciben un dispositivo de terapia de resincronización cardiaca, una mayor proporción de pacientes en clase funcional II de la New York Heart Association, con bloqueo completo de la rama izquierda del haz de His y con seguimiento a distancia, con estancias hospitalarias significativamente menores


Introduction and objectives: We describe the results for Spain of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II) and compare them with those of the other participating countries. Methods: We included patients undergoing CRT device implantation between October 2015 and December 2016 in 36 participating Spanish centers. We registered the patients' baseline characteristics, implant procedure data, and short-term follow-up information until hospital discharge. Results: Implant success was achieved in 95.9%. The median [interquartile range] annual implantation rate by center was significantly lower in Spain than in the other participating countries: 30 implants/y [21-50] vs 55 implants/y [33-100]; P=.00003. In Spanish centers, there was a lower proportion of patients ≥ 75 years (27.9% vs 32.4%; P=.0071), a higher proportion in NYHA class II (46.9% vs 36.9%, P <.00001), and a higher percentage with electrocardiographic criteria of left bundle branch block (82.9% vs 74.6%; P <.00001). The mean length of hospital stay was significantly lower in Spanish centers (5.8+/-8.5 days vs 6.4+/-11.6; P <.00001). Spanish patients were more likely to receive a quadripolar LV lead (74% vs 56%, P <.00001) and to be followed up by remote monitoring (55.8% vs 27.7%; P <.00001). Conclusions: The CRT-Survey II shows that, compared with other participating countries, fewer patients in Spain aged ≥ 75 years received a CRT device, while more patients were in New York Heart Association functional class II and had left bundle branch block. In addition, the length of hospital stay was shorter, and there was greater use of quadripolar LV leads and remote CRT monitoring


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Arritmias Cardíacas/terapia , Encuestas de Atención de la Salud/estadística & datos numéricos , Arritmias Cardíacas/epidemiología , Insuficiencia Cardíaca/epidemiología , Electrocardiografía/métodos , España/epidemiología , Europa (Continente)/epidemiología , Estudios Retrospectivos
12.
Rev. esp. cardiol. (Ed. impr.) ; 66(2): 119-123, feb. 2013. tab, ilus
Artículo en Español | IBECS (España) | ID: ibc-109032

RESUMEN

En este artículo se revisan los trabajos más relevantes en el campo de las arritmias publicados en 2012, incluyendo aritmología clínica, técnicas de ablación, estimulación cardiaca y genética de la muerte súbita (AU)


This article reviews the most relevant articles published in 2012 in the field of arrhythmias, on subjects that include clinical arrhythmology, ablation, cardiac pacing, and the genetics of sudden cardiac death (AU)


Asunto(s)
Humanos , Masculino , Femenino , Electrofisiología Cardíaca/métodos , Electrofisiología Cardíaca/tendencias , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Taquicardia Supraventricular/complicaciones , Taquicardia Supraventricular/diagnóstico , Marcapaso Artificial , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Electrofisiología Cardíaca/instrumentación , Electrofisiología Cardíaca/organización & administración , Electrofisiología Cardíaca/normas , Fibrilación Atrial/fisiopatología , Fibrilación Atrial , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular
15.
Rev. esp. cardiol. (Ed. impr.) ; 64(9): 745-751, sept. 2011.
Artículo en Español | IBECS (España) | ID: ibc-90862

RESUMEN

Introducción y objetivos. Los stents farmacoactivos son una herramienta útil para prevenir la reestenosis, pero los mecanismos involucrados en la respuesta proliferativa tras su implante aún no son conocidos en su totalidad. El objetivo de este estudio es comparar la histomorfometría vascular coronaria tras el implante de stents sin recubrir o stents farmacoactivos en un modelo porcino. Métodos. En 20 hembras de cerdos de la raza Large White de 2 meses de edad se implantó de forma aleatoria un total de 60 stents distribuidos en dos grupos: convencionales (n=20) y farmacoactivos (paclitaxel) (n=40). A los 28 días se procedió a eutanasia y análisis histomorfométrico. Se clasificó el grado de daño vascular en función de integridad o rotura de la túnica limitante elástica interna. Resultados. En el grupo de integridad de lámina elástica interna no se encontraron diferencias significativas entre stents farmacoactivos y stents convencionales para las variables área de neoíntima y porcentaje de reestenosis (1,3 [1,1-2,2] frente a 2 [1,3-2,5] mm2; p=0,6; y 14 [12,1-20,8] frente a 22,2 [14,1-23,3] %; p=0,5). En cambio, en el grupo de rotura de la lámina elástica interna sí se encontraron diferencias significativas (área de neoíntima, 1,2 [0,8-2] frente a 2,9 [2,3-3,7] mm2; p=0,001 y porcentaje de reestenosis, 16,63 [11,2-23,5] frente a 30,4 [26,4-45,7] %; p=0,001). Conclusiones. En el modelo porcino de coronarias sanas, la integridad de la lámina elástica interna no permite apreciar diferencias en la respuesta proliferativa entre stent farmacoactivo y convencional; la diferencia se establece sólo cuando el daño vascular es más profundo (AU)


Introduction and objectives. Drug-eluting stents are useful for preventing restenosis, but the patho-physiological processes involved in the proliferative response after implantation are still not known in detail. The aim of this study is to compare the coronary vascular histomorphometry after implanting drug-eluting stents and bare metal stents in a swine model. Methods. Sixty stents were randomly implanted in 20 Large White female pigs with a ratio of baremetal/drug-eluting stents of 1:2. After 28 days, euthanasia and histomorphometry were performed. We defined the vessel injury score in accordance to whether the internal elastic lamina was intact or ruptured. Results. There were no differences between drug-eluting stents and bare metal stents in the intact internal elastic lamina group regarding neointimal area or % restenosis (1.3 [1.1-2.2]) vs 2.0 [1.3-2.5] mm2; P=.6; and 14.0 [12.1-20.8] vs 22.2 [14.1-23.3] %; P=.5). We assessed statistically significant differences for the ruptured internal elastic lamina group, (neointimal area 1.2 [0.8-2.0] vs 2.9 [2.3-3.7] mm2; P=.001 and % restenosis 16.63 [11.2-23.5] vs 30.4 [26.4-45.7] %; P=.001). Conclusions. In our swine model, we did not find any differences between proliferative response of drug-eluting stents and bare metal stents when the internal elastic lamina is intact; differences are only found when vascular injury is deeper (AU)


Asunto(s)
Animales , Femenino , Porcinos/fisiología , Stents , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/terapia , Reestenosis Coronaria/veterinaria , Paclitaxel , Modelos Animales , Eutanasia , Experimentación Animal , Análisis de Varianza , Análisis Multivariante
16.
Rev. esp. cardiol. Supl. (Ed. impresa) ; 10(supl.A): 48a-52a, 2010.
Artículo en Español | IBECS (España) | ID: ibc-166874

RESUMEN

La ausencia de fármacos antiarrítmicos eficaces y seguros ha conducido al desarrollo de la ablación con catéter como terapia alternativa en el tratamiento de la fibrilación auricular. La adecuada aplicación de esta técnica requiere la identificación y representación fidedigna de la anatomía de la aurícula izquierda, la diferenciación de las zonas que mantienen la arritmia de las zonas que se activan pasivamente y la definición de unos objetivos de relevancia clínica. Esta revisión comenta y presenta las contribuciones más recientes en la integración de imágenes en los sistemas de navegación, las características de los electrogramas relacionados con zonas que mantienen la fibrilación auricular y los últimos objetivos que se han propuesto en este procedimiento (AU)


The lack of safe and effective antiarrhythmic drugs has led to the development of catheter ablation as an alternative means of treating atrial fibrillation. The correct use of this technique depends on accurately identifying and representing left atrial anatomy, differentiating tissue areas that maintain the arrhythmia from those that are passively activated, and defining clinically meaningful objectives. This review article describes and discusses recent advances in integrating images into navigation systems, electrogram patterns associated with tissue areas that maintain atrial fibrillation, and the latest endpoints proposed for use in the procedure (AU)


Asunto(s)
Humanos , Ablación por Catéter/métodos , Fibrilación Atrial/terapia , Imagenología Tridimensional , Electrocardiografía , Mapeo del Potencial de Superficie Corporal
18.
Rev. esp. cardiol. Supl. (Ed. impresa) ; 8(supl.A): 76a-85a, 2008. ilus, tab
Artículo en Español | IBECS (España) | ID: ibc-166393

RESUMEN

Los electrogramas almacenados por los desfibriladores implantables actuales permiten al clínico revisar las alteraciones eléctricas durante los eventos que conducen a la activación del desfibrilador, así como evaluar el resultado de la terapia administrada. En la mayoría de los pacientes, esta información permite efectuar un diagnóstico preciso del tipo de arritmia causante de la activación del dispositivo y, como resultado, optimizar el tratamiento de estos pacientes. Sin embargo, todavía es preciso establecer criterios de discriminación adicionales que nos permitan diferenciar con mayor precisión la etiología de los episodios detectados por el dispositivo. En este artículo se describen: a) los principios básicos para la discriminación de arritmias basado en el análisis del registro de los electrogramas intracavitarios (EGM) de los episodios; b) la utilidad del análisis de los EGM en el tratamiento de pacientes con arritmias ventriculares; c) las principales limitaciones de los métodos empleados, y d) finalmente, se presentan pruebas científicas de la utilidad de nuevos métodos de discriminación (AU)


The electrograms stored by present-day implantable cardioverter–defibrillators (ICDs) enable clinicians to review the electrical changes that occur during events leading to device discharge and to evaluate the effects of the therapy administered. In most patients, this information enables the type of arrhythmia responsible for ICD activation to be accurately determined and, consequently, treatment to be optimized. Nevertheless, additional discriminative criteria are needed to enable the etiology of the episodes detected by the device to be classified yet more accurately. This article considers: a) the basic principles for classifying arrhythmias on the basis of an analysis of stored intracardiac electrograms of arrhythmic episodes; b) the usefulness of intracardiac electrogram analysis for treating patients with ventricular arrhythmias; c) the main limitations of the classification methods currently used; and, finally, d) the evidence available on the usefulness of new classification methods (AU)


Asunto(s)
Humanos , Desfibriladores Implantables/normas , Desfibriladores Implantables , Electrofisiología Cardíaca/métodos , Electrofisiología Cardíaca/organización & administración , Taquicardia Supraventricular/terapia , Técnicas Electrofisiológicas Cardíacas/normas , Técnicas Electrofisiológicas Cardíacas , Taquicardia Sinusal/terapia
19.
Rev. esp. cardiol. (Ed. impr.) ; 56(2): 207-210, feb. 2003.
Artículo en Es | IBECS (España) | ID: ibc-18999

RESUMEN

Las taquicardias automáticas de la unión son una rara forma de taquiarritmia supraventricular, con incidencia sobre todo en la edad pediátrica y acompañadas de un mal pronóstico en su evolución espontánea. Presentamos el caso de un paciente de 22 meses de edad con una taquicardia incesante de la unión auriculoventricular con origen en un foco automático localizado en el haz de His o inmediato al mismo. Las aplicaciones de radiofrecuencia con incremento escalonado de temperatura en la misma región del haz de His consiguieron eliminar este automatismo sin complicaciones. (AU)


Asunto(s)
Masculino , Lactante , Humanos , Taquicardia Ectópica de Unión , Resultado del Tratamiento , Ablación por Catéter , Fascículo Atrioventricular
20.
Rev. esp. cardiol. (Ed. impr.) ; 53(3): 440-462, mar. 2000.
Artículo en Es | IBECS (España) | ID: ibc-2836

RESUMEN

Aunque los avances en el tratamiento del infarto agudo de miocardio han provocado una reducción en el riesgo de muerte súbita a largo plazo, éste sigue siendo elevado en ciertos subgrupos de pacientes. Son importantes la identificación y tratamiento de estos pacientes. La fracción de eyección ventricular izquierda menor de 0,40, extrasistolia ventricular frecuente en la monitorización Holter, potenciales tardíos en el electrocardiograma con señal promediada, variabilidad reducida de la frecuencia cardíaca, sensibilidad barorrefleja anormal y taquicardia ventricular monomórfica sostenida inducible durante estudio electrofisiológico son predictores de muerte súbita. Aunque el valor predictivo negativo de cada factor es alto, el valor predictivo positivo es bajo. Varias pruebas pueden combinarse para mejorar el valor predictivo positivo. En algunos estudios se ha usado la combinación de pruebas no invasivas para seleccionar pacientes para estimulación ventricular. Algunos tratamientos preventivos pueden emplearse en estos pacientes. Los datos disponibles no justifican el uso profiláctico de amiodarona en supervivientes de alto riesgo tras infarto. El tratamiento betabloqueante a largo plazo ha reducido significativamente la mortalidad súbita y total. Por tanto, los betabloqueantes deben administrarse en todos los pacientes con infarto agudo de miocardio que no presenten contraindicaciones para su uso. El estudio MADIT ha demostrado efecto beneficioso del desfibrilador automático implantable en la reducción de mortalidad en pacientes con infarto de miocardio previo, fracción de eyección menor de 0,36, taquicardia ventricular no sostenida asintomática y taquicardia ventricular sostenida inducible, no suprimible con procainamida. Varios estudios están evaluando el desfibrilador implantable profiláctico para mejorar la supervivencia en pacientes de alto riesgo (AU)


Asunto(s)
Humanos , Muerte Súbita Cardíaca , Pronóstico , Enfermedad Coronaria , Electrocardiografía , Frecuencia Cardíaca , Pruebas de Función Cardíaca
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA