Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 120(13): 132501, 2018 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-29694201

RESUMEN

The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number-violating process: ^{130}Te neutrinoless double-beta decay. Examining a total TeO_{2} exposure of 86.3 kg yr, characterized by an effective energy resolution of (7.7±0.5) keV FWHM and a background in the region of interest of (0.014±0.002) counts/(keV kg yr), we find no evidence for neutrinoless double-beta decay. Including systematic uncertainties, we place a lower limit on the decay half-life of T_{1/2}^{0ν}(^{130}Te)>1.3×10^{25} yr (90% C.L.); the median statistical sensitivity of this search is 7.0×10^{24} yr. Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find T_{1/2}^{0ν}(^{130}Te)>1.5×10^{25} yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find m_{ßß}<(110-520) meV, where the range reflects the nuclear matrix element estimates employed.

2.
Rev Sci Instrum ; 86(12): 124703, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26724052

RESUMEN

In this work, we present the first part of the power supply system for the CUORE and LUCIFER arrays of bolometric detectors. For CUORE, it consists of AC/DC commercial power supplies (0-60 V output) followed by custom DC/DC modules (48 V input, ±5 V to ±13.5 V outputs). Each module has 3 floating and independently configurable output voltages. In LUCIFER, the AC/DC + DC/DC stages are combined into a commercial medium-power AC/DC source. At the outputs of both setups, we introduced filters with the aim of lowering the noise and to protect the following stages from high voltage spikes that can be generated by the energy stored in the cables after the release of accidental short circuits. Output noise is very low, as required: in the 100 MHz bandwidth the RMS level is about 37 µV(RMS) (CUORE setup) and 90 µV(RMS) (LUCIFER setup) at a load of 7 A, with a negligible dependence on the load current. Even more importantly, high frequency switching disturbances are almost completely suppressed. The efficiency of both systems is above 85%. Both systems are completely programmable and monitored via CAN bus (optically coupled).

3.
Phys Rev Lett ; 96(4): 042503, 2006 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-16486813

RESUMEN

The mixed occurrence of s-wave and p-wave contributions in a first forbidden unique Gamow-Teller beta decay has been investigated for the first time by measuring the beta environmental fine structure (BEFS) in a 187Re crystalline compound. The experiment has been carried out with an array of eight AgReO4 thermal detectors operating at a temperature of approximately 100 mK. A fit of the observed BEFS spectrum indicates the p-wave electron emission as the dominant channel. The complete understanding of the BEFS distortion of the 187Re beta decay spectrum is crucial for future experiments aiming at the precise calorimetric measurement of the antineutrino mass.

4.
Phys Rev Lett ; 95(14): 142501, 2005 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-16241648

RESUMEN

We report the present results of CUORICINO, a search for neutrinoless double-beta (0nu betabeta) decay of 130Te. The detector is an array of 62 TeO2 bolometers with a total active mass of 40.7 kg. The array is cooled by a dilution refrigerator shielded from environmental radioactivity and energetic neutrons, operated at approximately 8 mK in the Gran Sasso Underground Laboratory. No evidence for (0nu betabeta) decay was found and a new lower limit, T(1/2)(0nu) > or = 1.8 x 10(24) yr (90% C.L.) is set, corresponding to [m(nu)] < or = 0.2 to 1.1 eV, depending on the theoretical nuclear matrix elements used in the analysis.

5.
Phys Rev Lett ; 91(16): 161802, 2003 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-14611391

RESUMEN

High statistics calorimetric measurements of the beta spectrum of 187Re are being performed with arrays of silver perrhenate crystals operated at low temperature. After a substantial modification of the experimental setup, a new measurement with ten silver perrhenate microbolometers has been running since July 2002. The crystals have masses around 300 microg and their average FWHM energy resolution is of 28.3 eV at the beta end point. The Kurie plot collected during 4485 h x mg effective running time has an end-point energy of 2466.1+/-0.8(stat)+/-1.5(syst) eV, while the half lifetime of the decay is found to be 43.2+/-0.2(stat)+/-0.1(syst) Gy. These values are the most precise obtained so far for 187Re. The best fit value for m(2)(nu(e)) is 147+/-237(stat)+/-90(syst) eV(2), which corresponds to an upper limit for the electron antineutrino mass m(nu(e))< or =21.7 eV at 90% C.L.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA