Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Biomarkers ; 29(4): 205-210, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38588595

RESUMEN

BACKGROUND: Currently available risk scores fail to accurately predict morbidity and mortality in patients with severe symptomatic aortic stenosis who undergo transcatheter aortic valve implantation (TAVI). In this context, biomarkers like matrix metalloproteinase-2 (MMP-2) and Galectin-3 (Gal-3) may provide additional prognostic information. METHODS: Patients with severe aortic stenosis undergoing consecutive, elective, transfemoral TAVI were included. Baseline demographic data, functional status, echocardiographic findings, clinical outcomes and biomarker levels were collected and analysed. RESULTS: The study cohort consisted of 89 patients (age 80.4 ± 5.1 years, EuroScore II 7.1 ± 5.8%). During a median follow-up period of 526 d, 28 patients (31.4%) died. Among those who died, median baseline MMP-2 (alive: 221.6 [170.4; 263] pg/mL vs. deceased: 272.1 [225; 308.8] pg/mL, p < 0.001) and Gal-3 levels (alive: 19.1 [13.5; 24.6] pg/mL vs. deceased: 25 [17.6; 29.5] pg/mL, p = 0.006) were higher than in survivors. In ROC analysis, MMP-2 reached an acceptable level of discrimination to predict mortality (AUC 0.733, 95% CI [0.62; 0.83], p < 0.001), but the predictive value of Gal-3 was poor (AUC 0.677, 95% CI [0.56; 0.79], p = 0.002). Kaplan-Meier and Cox regression analyses showed that patients with MMP-2 and Gal-3 concentrations above the median at baseline had significantly impaired long-term survival (p = 0.004 and p = 0.02, respectively). CONCLUSIONS: In patients with severe aortic stenosis undergoing transfemoral TAVI, MMP-2 and to a lesser extent Gal-3, seem to have additive value in optimizing risk prediction and streamlining decision-making.


Asunto(s)
Estenosis de la Válvula Aórtica , Biomarcadores , Galectina 3 , Metaloproteinasa 2 de la Matriz , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Metaloproteinasa 2 de la Matriz/sangre , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Biomarcadores/sangre , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/sangre , Galectina 3/sangre , Anciano de 80 o más Años , Anciano , Pronóstico , Galectinas , Proteínas Sanguíneas/análisis , Proteínas Sanguíneas/metabolismo
2.
Catheter Cardiovasc Interv ; 97(1): E146-E153, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32433818

RESUMEN

BACKGROUND: Cerebral O2 saturation (ScO2 ) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). OBJECTIVES: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. METHODS AND RESULTS: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. CONCLUSIONS: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Proyectos Piloto , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Heart Vessels ; 34(12): 1993-2001, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31175405

RESUMEN

Current risk scores used for patients undergoing transcatheter aortic valve implantation (TAVI) do not reliably predict adverse events after TAVI. Procalcitonin (PCT) is associated with increased atherosclerotic burden and adverse outcomes in patients with cardiovascular disease. The aim of our study is to assess the predictive value of preprocedural serum PCT levels in comparison with established risk scores in TAVI patients. A total of 243 patients undergoing transfemoral TAVI at our institution were included prospectively in the study and 230 of these patients participated in the follow-up 1 year after TAVI. The primary endpoints were mortality at 30 days and 1 year. Multivariable analysis revealed that preprocedural PCT was the only independent predictor of 30-day mortality (HR 2.84; 95% CI 1.59-5.06; p < 0.001) and 1-year mortality (HR 1.90; 95% CI 1.17-3.11; p = 0.01), whereas high-sensitivity C-reactive protein showed no association with procedural outcomes. The results of ROC analysis showed good predictive power of PCT for both outcomes (AUC 0.75; p = 0.0003 for 30-day mortality and AUC 0.71; p < 0.0001 for 1-year mortality). An optimal cut-off value for PCT of 0.06 ng/ml for short- and long-term mortality was determined with the Youden index. A significantly higher mortality rate was observed in the high-PCT group (≥ 0.06 ng/ml) based on Kaplan-Meier analysis (log rank = 12.1; p = 0.001 at 30 days and log rank = 14.2; p = 0.0002 at 1 year). Patients in the high-PCT group also had a considerably worse clinical pro6file. In conclusion, preprocedural PCT is an independent predictor of 30-day and 1-year mortality after TAVI. In particular, a cut-off value of 0.06 ng/ml discriminates patients at higher risk of mortality within 30 days and 1 year of TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Polipéptido alfa Relacionado con Calcitonina/sangre , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Biomarcadores/sangre , Cateterismo Cardíaco/métodos , Ecocardiografía Transesofágica , Femenino , Arteria Femoral , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Incidencia , Masculino , Periodo Preoperatorio , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo
4.
Thorac Cardiovasc Surg ; 67(4): 266-273, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29715705

RESUMEN

BACKGROUND: Modern supraannular aortic xenografts offer a special design, thus providing maximized opening area for improved hemodynamics. The aim of this study was a prospectively randomized comparison of the Trifecta and the Perimount Magna Ease valves based on metric annulus sizing. METHODS: A total of 100 patients with aortic stenosis undergoing aortic valve replacement (AVR) with or without concomitant procedures were prospectively included. After decalcification of the annulus, stratified intraoperative randomization was performed. The diameter of the aortic annulus was measured using metric Hegar dilators and randomization was based on this metric annulus diameter. Exercise echocardiography was performed at 10-month follow-up. RESULTS: Mean age was 69 years, with 36% female. Predominant implanted valve sizes were 23 mm (39%) and 25 mm (32%). Unadjusted mean pressure gradient was significantly lower and effective orifice area larger for the Trifecta group (10.8 ± 5 vs. 13.2 ± 4 mm Hg, p = 0.02 and 1.93 ± 0.39 vs. 1.70 ± 0.30 cm2, p = 0.002) at discharge. In patients with small annuli, based on the metric annulus size there were no significant differences in gradients or the orifice area. At exercise echocardiography follow-up, there were no significant hemodynamic differences between both prostheses. CONCLUSIONS: The Trifecta and the Perimount Magna Ease prostheses both show excellent hemodynamic performance after AVR. In patients with larger annuli, the Trifecta valve seems to be even superior to the Magna Ease, which may be advantageous in obese patients.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Bioprótesis , Calcinosis/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Ecocardiografía de Estrés/métodos , Prueba de Esfuerzo , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Xenoinjertos , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento
5.
J Interv Cardiol ; 31(1): 68-73, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29285803

RESUMEN

OBJECTIVES: Evaluate the role of balloon aortic valvuloplasty (BAV) in improving candidacy of patients for transcatheter aortic valve replacement (TAVR). BACKGROUND: Patients who are not candidates for TAVR may undergo BAV to improve functional and clinical status. METHODS: 117 inoperable or high-risk patients with critical aortic stenosis underwent BAV as a bridge-to-decision for TAVR. Frailty measures including gait speed, serum albumin, hand grip, activities of daily living (ADL); and NYHA functional class before and after BAV were compared. RESULTS: Mean age was 81.6 ± 8.5 years and the mean Society of Thoracic Surgeons predicted risk of mortality was 9.57 ± 5.51, with 19/117 (16.2%) patients non-ambulatory. There was no significant change in mean GS post-BAV, but all non-ambulatory patients completed GS testing at follow-up. Albumin and hand grip did not change after BAV, but there was a significant improvement in mean ADL score (4.85 ± 1.41 baseline to 5.20 ± 1.17, P = 0.021). The number of patients with Class IV congestive heart failure (CHF) was significantly lower post BAV (71/117 [60.7%] baseline versus 18/117 [15.4%], P = 0.008). 78/117 (66.7%) of patients were referred to definitive valve therapy after BAV. CONCLUSIONS: When evaluating frailty measures post BAV, we saw no significant improvement in mean GS, however, we observed a significant improvement in non-ambulatory patients and ADL scores. We also describe improved Class IV CHF symptoms. With this improved health status, the majority of patients underwent subsequent valve therapy, demonstrating that BAV may improve candidacy of patients for TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Reemplazo de la Válvula Aórtica Transcatéter , Actividades Cotidianas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/rehabilitación , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/métodos , Femenino , Fuerza de la Mano , Humanos , Masculino , Cuidados Preoperatorios/métodos , Recuperación de la Función , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
6.
Eur Heart J ; 38(9): 634-638, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-26358570

RESUMEN

Tricuspid regurgitation (TR) is the most common lesion of the tricuspid valve (TV). Mild TR is common and usually is benign. However, moderate or severe TR can lead to irreversible myocardial damage and adverse outcomes. Despite these findings, few patients with significant TR undergo surgery. The treatment of functional (secondary) TR in particular remains controversial because of high rates of residual or recurrent TR and poor outcomes following surgical intervention. Traditional teaching that functional TR resolves on its own if the underlying disease is successfully treated has proven to be incorrect. This review aims to clarify management of TR by describing the anatomy, pathophysiology, diagnosis, and treatment of TR, including the eventual possibility of percutaneous TV therapy.


Asunto(s)
Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/métodos , Ecocardiografía/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/etiología
7.
Eur Heart J ; 37(10): 803-10, 2016 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-26578195

RESUMEN

Since the introduction of transcatheter aortic valve implantation (TAVI) into clinical practice, the treatment of aortic stenosis has changed dramatically. In the past, medical therapy with or without balloon aortic valvuloplasty was the only option for inoperable patients. More recently, TAVI has become the treatment of choice for these patients and the preferred alternative for high-risk operable patients. Surgical aortic valve replacement (SAVR) currently remains the gold standard for patients at low or intermediate operative risk. As randomized trials have demonstrated comparable results between TAVI and SAVR in the high-risk population, there is now a clear trend towards performing TAVI even in intermediate-risk patients while awaiting the results of randomized trials in that population. Nevertheless, there are still questions regarding TAVI involving paravalvular leak (PVL), stroke, pacemaker requirements, and durability that remain to be more definitively answered before TAVI can routinely be performed in a broader, lower risk population. Improvements in patient selection, imaging, and second and third generation devices have decreased the incidence of PVLs and vascular complications that followed the earliest TAVI procedures, but the rates of perioperative stroke and permanent pacemaker implantation must still be addressed. Furthermore, the long-term durability of TAVI devices and a role for post-procedure antithrombotic management remain unanswered. Until these questions are more clearly answered, it is the Heart Team's task to determine the optimal treatment for each patient based on risk scores, frailty metrics, comorbidities, patient preference, and potential for improvement in quality of life.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Fibrinolíticos/uso terapéutico , Predicción , Salud Global/estadística & datos numéricos , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/normas , Humanos , Marcapaso Artificial/estadística & datos numéricos , Selección de Paciente , Complicaciones Posoperatorias/etiología , Guías de Práctica Clínica como Asunto , Falla de Prótesis , Mecanismo de Reembolso , Factores de Riesgo , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Calcificación Vascular/cirugía
9.
Artículo en Inglés | MEDLINE | ID: mdl-25966964

RESUMEN

Transcatheter aortic valve implantation (T-AVI) has become the standard of care for high-risk patients suffering from severe aortic valve stenosis. More than 60,000 implants have been performed to date. While the first-generation T-AVI devices had some specific issues, the advancements in these first-generation devices and the development of second-generation devices significantly reduced the incidence of peri-procedural complications. The two major access routes are the transfemoral (TF) and the transapical (TA) approach. Both approaches have their advantages and should be considered equal alternatives for finding the best treatment option for the individual patient. Currently there are discussions about extending the indication to patients with lower risk profiles. However, there is no real evidence to justify an expansion, as results of surgical aortic valve replacement in low and intermediate risk patients are excellent.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Vena Femoral , Prótesis Valvulares Cardíacas , Ventrículos Cardíacos , Humanos , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
10.
Gigascience ; 132024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38573186

RESUMEN

BACKGROUND: Cardiovascular research heavily relies on mouse (Mus musculus) models to study disease mechanisms and to test novel biomarkers and medications. Yet, applying these results to patients remains a major challenge and often results in noneffective drugs. Therefore, it is an open challenge of translational science to develop models with high similarities and predictive value. This requires a comparison of disease models in mice with diseased tissue derived from humans. RESULTS: To compare the transcriptional signatures at single-cell resolution, we implemented an integration pipeline called OrthoIntegrate, which uniquely assigns orthologs and therewith merges single-cell RNA sequencing (scRNA-seq) RNA of different species. The pipeline has been designed to be as easy to use and is fully integrable in the standard Seurat workflow.We applied OrthoIntegrate on scRNA-seq from cardiac tissue of heart failure patients with reduced ejection fraction (HFrEF) and scRNA-seq from the mice after chronic infarction, which is a commonly used mouse model to mimic HFrEF. We discovered shared and distinct regulatory pathways between human HFrEF patients and the corresponding mouse model. Overall, 54% of genes were commonly regulated, including major changes in cardiomyocyte energy metabolism. However, several regulatory pathways (e.g., angiogenesis) were specifically regulated in humans. CONCLUSIONS: The demonstration of unique pathways occurring in humans indicates limitations on the comparability between mice models and human HFrEF and shows that results from the mice model should be validated carefully. OrthoIntegrate is publicly accessible (https://github.com/MarianoRuzJurado/OrthoIntegrate) and can be used to integrate other large datasets to provide a general comparison of models with patient data.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Animales , Ratones , Insuficiencia Cardíaca/genética , Transcriptoma , Volumen Sistólico , Metabolismo Energético , ARN
11.
J Invasive Cardiol ; 35(4): E161-E168, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36827082

RESUMEN

BACKGROUND: Early graft failure (EGF) after coronary artery bypass grafting (CABG) occurs in up to 12% of grafts, but is often clinically unapparent. EGF may result in perioperative myocardial infarction with consequently increased mortality. The aim of the present study was to analyze the incidence of clinically apparent EGF in patients undergoing CABG and the influence on mortality. METHODS: We analyzed outcomes of consecutive patients undergoing CABG from January 2015 to December 2018 with respect to postoperative emergency coronary angiography (CAG) due to suspected EGF and 30-day mortality. Patients with CAG-documented EGF were matched to patients without EGF to examine predictors of mortality. RESULTS: The analysis included 5638 patients undergoing CABG. Eighty-six patients (1.5%) underwent emergency CAG due to suspected EGF. Clinically apparent EGF was observed in 61 of these patients (70.9%), whereas 14 (16.3%) had a culprit lesion in a native coronary artery. The majority of patients (n = 45; 52.3%) were treated with percutaneous coronary intervention and 31 (36%) underwent re-do CABG. The remaining patients were treated conservatively. The 30-day mortality rate of suspected EGF patients undergoing CAG was 22.4% (n = 19), which was higher than the mortality rate of 2.8% overall (P<.001); this remained higher after matching the EGF patients with the control group (11 [20.4%] vs 2 [4.0%]; P=.02). CONCLUSION: Emergency CAG after CABG is rare and is primarily carried out in patients with EGF. The 30-day mortality rate of these patients is high, and EGF is an independent predictor of mortality. Perioperative CAG with subsequent treatment is mandatory in these patients.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Humanos , Factor de Crecimiento Epidérmico , Resultado del Tratamiento , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones
12.
Clin Res Cardiol ; 112(10): 1382-1393, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36790465

RESUMEN

BACKGROUND: Fibroblast growth factor 23 (FGF-23) has been associated with left ventricular hypertrophy (LVH) and heart failure. However, its role in right ventricular (RV) remodeling and RV failure is unknown. This study analyzed the utility of FGF-23 as a biomarker of RV function in patients with pulmonary hypertension (PH). METHODS: In this observational study, FGF-23 was measured in the plasma of patients with PH (n = 627), dilated cardiomyopathy (DCM, n = 59), or LVH with severe aortic stenosis (n = 35). Participants without LV or RV abnormalities served as controls (n = 36). RESULTS: Median FGF-23 plasma levels were higher in PH patients than in healthy controls (p < 0.001). There were no significant differences between PH, DCM, and LVH patients. Analysis across tertiles of FGF-23 levels in PH patients revealed an association between higher FGF-23 levels and higher levels of NT-proBNP and worse renal function. Furthermore, patients in the high-FGF-23 tertile had a higher pulmonary vascular resistance (PVR), mean pulmonary artery pressure, and right atrial pressure and a lower cardiac index (CI) than patients in the low tertile (p < 0.001 for all comparisons). Higher FGF-23 levels were associated with higher RV end-diastolic diameter and lower tricuspid annular plane systolic excursions (TAPSE) and TAPSE/PASP. Receiver operating characteristic analysis revealed FGF-23 as a good predictor of RV maladaptation, defined as TAPSE < 17 mm and CI < 2.5 L/min/m2. Association of FGF-23 with parameters of RV function was independent of the glomerular filtration rate in regression analysis. CONCLUSION: FGF-23 may serve as a biomarker for maladaptive RV remodeling in patients with PH.


Asunto(s)
Insuficiencia Cardíaca , Hipertensión Pulmonar , Disfunción Ventricular Derecha , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Disfunción Ventricular Derecha/diagnóstico , Disfunción Ventricular Derecha/etiología , Factor-23 de Crecimiento de Fibroblastos , Biomarcadores , Función Ventricular Derecha
13.
Cardiovasc Res ; 119(15): 2550-2562, 2023 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-37648651

RESUMEN

AIMS: Cardiac fibrosis drives the progression of heart failure in ischaemic and hypertrophic cardiomyopathy. Therefore, the development of specific anti-fibrotic treatment regimens to counteract cardiac fibrosis is of high clinical relevance. Hence, this study examined the presence of persistent fibroblast activation during longstanding human heart disease at a single-cell resolution to identify putative therapeutic targets to counteract pathological cardiac fibrosis in patients. METHODS AND RESULTS: We used single-nuclei RNA sequencing with human tissues from two samples of one healthy donor, and five hypertrophic and two failing hearts. Unsupervised sub-clustering of 7110 nuclei led to the identification of 7 distinct fibroblast clusters. De-convolution of cardiac fibroblast heterogeneity revealed a distinct population of human cardiac fibroblasts with a molecular signature of persistent fibroblast activation and a transcriptional switch towards a pro-fibrotic extra-cellular matrix composition in patients with established cardiac hypertrophy and heart failure. This sub-cluster was characterized by high expression of POSTN, RUNX1, CILP, and a target gene adipocyte enhancer-binding protein 1 (AEBP1) (all P < 0.001). Strikingly, elevated circulating AEBP1 blood level were also detected in a validation cohort of patients with confirmed cardiac fibrosis and hypertrophic cardiomyopathy by cardiac magnetic resonance imaging (P < 0.01). Since endogenous AEBP1 expression was increased in patients with established cardiac hypertrophy and heart failure, we assessed the functional consequence of siRNA-mediated AEBP1 silencing in human cardiac fibroblasts. Indeed, AEBP1 silencing reduced proliferation, migration, and fibroblast contractile capacity and α-SMA gene expression, which is a hallmark of fibroblast activation (all P < 0.05). Mechanistically, the anti-fibrotic effects of AEBP1 silencing were linked to transforming growth factor-beta pathway modulation. CONCLUSION: Together, this study identifies persistent fibroblast activation in patients with longstanding heart disease, which might be detected by circulating AEBP1 and therapeutically modulated by its targeted silencing in human cardiac fibroblasts.


Asunto(s)
Cardiomiopatías , Cardiomiopatía Hipertrófica , Cardiopatías , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/metabolismo , Cardiopatías/patología , Cardiomegalia/metabolismo , Cardiomiopatía Hipertrófica/metabolismo , Cardiomiopatías/metabolismo , Fibrosis , Fibroblastos/metabolismo , Perfilación de la Expresión Génica , Carboxipeptidasas/metabolismo , Proteínas Represoras/metabolismo
15.
Biomark Med ; 16(17): 1209-1218, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36861450

RESUMEN

Aim: Presepsin is a sensitive biomarker for the diagnosis and estimation of prognosis in septic patients. The prognostic role of presepsin in patients undergoing transcatheter aortic valve implantation (TAVI) has never been investigated. Patients, materials & methods: In 343 patients, presepsin and N-terminal pro-B-type natriuretic peptide were measured before TAVI. One-year all-cause mortality was used as outcome measure. Results: Patients with high presepsin levels were more likely to succumb than patients with low presepsin values (16.9% vs 12.3%; p = 0.015). Elevated presepsin remained a significant predictor of 1-year all-cause mortality (odds ratio: 2.2 [95% CI: 1.12-4.29]; p = 0.022) after adjustment. N-terminal pro-B-type natriuretic peptide did not predict 1-year all-cause mortality. Conclusion: Elevated baseline presepsin levels are an independent predictor of 1-year mortality in TAVI patients.


Presepsin is a rather novel blood parameter that is most commonly used for the detection of severe infections. However, in patients without infections who are undergoing elective surgery, elevated baseline presepsin levels were also found to be associated with worse survival. In this study, researchers wanted to know whether increased presepsin levels can also predict worse survival in patients who are planned for transcatheter aortic valve implantation. To do so, they looked at the 1-year death rate of these patients and distinguished between low and high presepsin levels determined before the procedure. Patients with elevated presepsin levels before the procedure had a worse outcome after 1 year compared with those with low presepsin levels. Measurement of presepsin before the transcatheter aortic valve implantation procedure could help identify patients who are at a higher long-term risk, and accordingly a closer monitoring of these patients during the follow-up period might be warranted.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Péptido Natriurético Encefálico , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Pronóstico , Biomarcadores , Resultado del Tratamiento , Factores de Riesgo , Fragmentos de Péptidos , Receptores de Lipopolisacáridos
16.
Int J Cardiol Heart Vasc ; 36: 100862, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34504944

RESUMEN

BACKGROUND: A transapical (TA) approach to transcatheter aortic valve replacement (TAVR) may be used when a transfemoral (TF) approach is not feasible. The CHANGE neo TA study evaluated patients treated in routine clinical practice via TA-TAVR with the ACURATE neo bioprosthetic aortic valve. METHODS AND RESULTS: This single-arm post-market study had a planned enrolment of 200 subjects; enrolment was terminated early due to declining TA-TAVR procedures at participating centers. Final enrolment was 107 patients (mean age: 79.3 years; 54.2% female; mean STS score at baseline: 6.2%). The mortality rate in the intent-to-treat population was 11.2% at 30 days (primary endpoint) and 25.6% at 12 months. The VARC-2 composite endpoint for 30-day safety occurred in 24.3% of patients. Six patients (5.6%) received a permanent pacemaker within 30 days. Site-reported echocardiographic data showed early improvements in mean aortic valve gradient (baseline: 38.8 [SD 13.1] mmHg, discharge: 6.7 [SD 3.7] mmHg) and effective orifice area (baseline: 0.7 [SD 0.2] cm2, discharge: 1.9 [SD 0.6] cm2), and the discharge rate of paravalvular regurgitation was low (74.7% none/trace, 24.2% mild, 1.1% severe). CONCLUSIONS: TA-TAVR with the ACURATE neo valve system yields acceptable clinical outcomes, providing an alternative for patients with aortic stenosis who are not candidates for TF-TAVR.

17.
J Thorac Dis ; 12(4): 1728-1739, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32395315

RESUMEN

Mitral valve regurgitation (MR) belongs to one of the most common acquired valve diseases in western countries with increasing prevalence in older age. For patients with high perioperative risk and older age prohibitive for valve surgery, the development of transcatheter mitral valve therapies offers new options. Assessment of the severity and etiology of MR and thorough imaging of the mitral valve anatomy and pathology are necessary prerequisites for appropriate decision making in the field of transcatheter mitral valve therapies. Different transcatheter repair and replacement techniques are on the market, most of them mimicking surgical techniques. With some techniques (e.g., the MitraClip device), there is good clinical experience (>80,000 devices implanted worldwide), and evidence (three randomized studies), whereas for newer procedures, safety and efficacy data are still very limited. Transcatheter mitral repair and replacement techniques have to be considered as complementary treatment options for high-risk patients indicated by the Heart Teams. The different techniques and devices will be introduced and discussed in the following paper.

18.
J Plast Surg Hand Surg ; 54(3): 182-186, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32162994

RESUMEN

Deep sternal wound infection (DSWI) is a life threatening complication after cardiac surgery. In severe cases, flaps are needed to cover the wound. However, it is controversial if an aseptic environment is necessary at the time of wound closure. This is a retrospective study of 73 patients with DSWI treated by debridement and local or free flap from June 2008 until December 2017. The influence of positive microbiological findings at the time of plastic reconstructive surgery on reoperation rate and length of in-hospital stay was analyzed. Microbiological exams revealed positive results in 47 (64.4%) and no results in 26 patients. Reoperation had to be performed in 21.3% (positive cultures) versus 15.4% (p = .54), mean in hospital stay was 24.1 days (positive cultures) versus 21.8 days (p = .39) and in-hospital mortality was 6.4% (positive cultures) versus 7.7% (p = .83). Positive microbial findings at the time of plastic reconstructive surgery in patients with DSWI are not associated with a higher reoperation or mortality rate or a longer in-hospital stay. Repeated debridement and vacuum-assisted therapy to achieve negative microbial results might not be necessary in the treatment of these patients.Key messagesPositive microbial findings at the time of plastic reconstructive surgery in patients with deep sternal wound infection seems not to be associated with a higher reoperation or mortality rate or a longer in-hospital stay.The influence of positive microbiological findings at the time of plastic reconstructive surgery on reoperation rate and length of in-hospital stay was analyzed in 73 patients with deep sternal wound infection.Microbiological exams revealed positive results in 47 (64.4%) and no results in 26 patients. Reoperation had to be performed in 21.3% (positive cultures) versus 15.4% (p = .54), mean in hospital stay was 24.1 days (positive cultures) versus 21.8 days (p = .39) and in-hospital mortality was 6.4% (positive cultures) versus 7.7% (p = .83).


Asunto(s)
Esternotomía/efectos adversos , Esternón/microbiología , Esternón/cirugía , Infección de la Herida Quirúrgica/microbiología , Infección de la Herida Quirúrgica/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Femenino , Mortalidad Hospitalaria , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Reoperación/estadística & datos numéricos , Estudios Retrospectivos
19.
Ann Thorac Surg ; 110(3): 897-902, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32057811

RESUMEN

BACKGROUND: Various devices are available for endoscopic radial artery harvesting during coronary artery bypass grafting. Thermal spread and graft damage, however, are common concerns. The aim of this study was to compare the MiFusion TLS2 system (Endotrust, Nettetal Germany) with direct heat technique and the LigaSure Maryland system (Medtronic, Dublin, Ireland) using advanced bipolar technique in a prospective randomized study. METHODS: One hundred consecutive patients undergoing coronary artery bypass grafting with endoscopic radial artery harvesting were prospectively included and randomized 1:1. The proximal (brachial) ends of the grafts were analyzed using fluorescence microscopy with focus on graft integrity. In addition, harvesting time, graft sealing, residual bleeding, and incidence of neurological disorders were compared. RESULTS: Patient age was 67 ± 8 years. Mean harvesting time was 26.5 ± 9 minutes for the TLS2 and 23.2 ± 8 minutes for the LigaSure (P = .049). Overall graft integrity was good in both groups. A significantly better graft integrity was observed in the LigaSure group (scale 0 to 3; 3 = best) with 2.5 ± 0.6 for TLS2 and 2.8 ± 0.4 for LigaSure (P = .031). LigaSure provided significantly better graft sealing (scale 0 to 2; 0 = best) with 0.6 ± 0.7 vs 1.0 ± 0.6 (TLS2) (P = .006) and less residual bleeding (scale 1 to 5; 1 = best) with 1.4 ± 0.6 vs 2.0 ± 0.9 (TLS2) (P < .001). Transient sensibility disorders were less frequently observed with LigaSure (2% vs 16%, P = .015). CONCLUSIONS: Endoscopic radial artery harvesting can be performed with excellent results and good graft integrity using both devices. Compared with the MiFusion TLS2, the LigaSure device led to faster procedural times and resulted in better graft integrity. Along with providing a better seal, LigaSure was associated with less sensibility disorders.


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Endoscopía/métodos , Arteria Radial/trasplante , Recolección de Tejidos y Órganos/instrumentación , Anciano , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Periodo Intraoperatorio , Masculino , Estudios Prospectivos
20.
J Card Surg ; 24(5): 591-9, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19538224

RESUMEN

BACKGROUND: There is a regenerative potential of bone marrow-derived stem cells (BMCs) in ischemic cardiomyopathy, but little is known of their effects in nonischemic cardiomyopathy. This study evaluates the effects of BMC transplantation on contractility and remote capillary density of doxorubicin-induced failing hearts. METHODS: Heart failure was induced in rabbits by doxorubicin (3 mg/kg; 6 weeks), followed by BMC transplantation (BMC group, 1.5-2.0 x 10(6) cells, n = 15), sham treatment (Medium group, n = 10), or no therapy (Dox group, n = 6). Healthy rabbits were used as controls (n = 10). Cells were transplanted locally into the left ventricle (LV). Four weeks later, contractility was assessed. Cross-sections of hearts were investigated by H&E, Picrosirius red stain, and immunohistologically (Troponin I, alpha-Actinin, Connexin43). Capillary density (CD31-antigen) was examined in the LV, septum, and right ventricle (RV). RESULTS: Global contractility was significantly higher in the BMC group versus Medium group (ejection fraction: 39.0 +/- 1.4% vs. 30.0 +/- 1.9%, p = 0.002, and fractional shortening: 22 +/- 0.8 vs. 19 +/- 0.6, p < 0.01). Hemodynamic measurements by Millar catheter (Millar Instruments, Houston, TX, USA) were also significantly improved. Capillary density increased in cell-treated hearts (LV: 55 +/- 2.2 vs. 42 +/- 2.0, p < 0.001, RV: 40 +/- 2.1 vs. 35 +/- 1.7, p = 0.065, and septum: 46 +/- 1.5 vs. 39 +/- 1.7, p = 0.005), when compared to the Medium group. The transplanted cells failed to express cardiac markers. The collagen content was reduced in BMC-treated rabbits. CONCLUSION: Despite local cell transplantation, autologous BMCs improve global contractility and enhance remote capillary density and collagen content in doxorubicin-induced cardiomyopathy. However, BMCs failed to transdifferentiate into new cardiomyocytes.


Asunto(s)
Antibióticos Antineoplásicos/efectos adversos , Trasplante de Médula Ósea , Médula Ósea , Capilares , Doxorrubicina/efectos adversos , Insuficiencia Cardíaca/terapia , Animales , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/diagnóstico por imagen , Hemodinámica , Masculino , Conejos , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA