Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur J Clin Microbiol Infect Dis ; 43(3): 489-499, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38195783

RESUMEN

INTRODUCTION: Dead space management following debridement surgery in chronic osteomyelitis or septic non-unions is one of the most crucial and discussed steps for the success of the surgical treatment of these conditions. In this retrospective clinical study, we described the efficacy and safety profile of surgical debridement and local application of S53P4 bioactive glass (S53P4 BAG) in the treatment of bone infections. METHODS: A consecutive single-center series of 38 patients with chronic osteomyelitis (24) and septic non-unions (14), treated with bioactive glass S53P4 as dead space management following surgical debridement between May 2015 and November 2020, were identified and evaluated retrospectively. RESULTS: Infection eradication was reached in 22 out of 24 patients (91.7%) with chronic osteomyelitis. Eleven out of 14 patients (78.6%) with septic non-union achieved both fracture healing and infection healing in 9.1 ± 4.9 months. Three patients (7.9%) developed prolonged serous discharge with wound dehiscence but healed within 2 months with no further surgical intervention. Average patient follow-up time was 19.8 months ± 7.6 months. CONCLUSION: S53P4 bioactive glass is an effective and safe therapeutic option in the treatment of chronic osteomyelitis and septic non-unions because of its unique antibacterial properties, but also for its ability to generate a growth response in the remaining healthy bone at the bone-glass interface.


Asunto(s)
Sustitutos de Huesos , Osteomielitis , Humanos , Estudios Retrospectivos , Sustitutos de Huesos/uso terapéutico , Antibacterianos/uso terapéutico , Infección Persistente , Osteomielitis/tratamiento farmacológico , Osteomielitis/cirugía , Osteomielitis/microbiología
2.
Int J Mol Sci ; 25(2)2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38256225

RESUMEN

Diabetes affected 537 million adults in 2021, costing a total of USD 966 billion dollars in healthcare. One of the most common complications associated with diabetes corresponds to the development of diabetic foot ulcers (DFUs). DFUs affect around 15% of diabetic patients; these ulcers have impaired healing due to neuropathy, arterial disease, infection, and aberrant extracellular matrix (ECM) degradation, among other factors. The bioactive-glass-based materials discussed in this systematic review show promising results in accelerating diabetic wound healing. It can be concluded that the addition of BG is extremely valuable with regard to the wound healing rate and wound healing quality, since BG activates fibroblasts, enhances M1-to-M2 phenotype switching, induces angiogenesis, and initiates the formation of granulation tissue and re-epithelization of the wound. In addition, a higher density and deposition and better organization of collagen type III are seen. This systematic review was made using the PRISMA guideline and intends to contribute to the advancement of diabetic wound healing therapeutic strategies development by providing an overview of the materials currently being developed and their effect in diabetic wound healing in vitro and in vivo.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Adulto , Humanos , Cicatrización de Heridas , Pie Diabético/terapia , Tejido de Granulación , Colágeno Tipo III , Fibroblastos
3.
J Bone Miner Metab ; 40(2): 220-228, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34755216

RESUMEN

INTRODUCTION: Although computed tomography (CT) can identify the presence of eventual bony bridges following lumbar interbody fusion (LIF) surgery, it does not provide information on the ongoing formation process of new bony structures. 18F sodium fluoride (18F-NaF) positron emission tomography (PET) could be used as complementary modality to add information on the bone metabolism at the fusion site. However, it remains unknown how bone metabolism in the operated segment changes early after surgery in uncompromised situations. This study aimed to quantify the changes in local bone metabolism during consolidation of LIF. MATERIALS AND METHODS: Six skeletally mature sheep underwent LIF surgery. 18F-NaF PET/CT scanning was performed 6 and 12 weeks postoperatively to quantify the bone volume and metabolism in the operated segment. Bone metabolism was expressed as a function of bone volume. RESULTS: Early in the fusion process, bone metabolism was increased at the endplates of the operated vertebrae. In a next phase, bone metabolism increased in the center of the interbody region, peaked, and declined to an equilibrium state. During the entire postoperative time period of 12 weeks, bone metabolism in the interbody region was higher than that of a reference site in the spinal column. CONCLUSION: Following LIF surgery, there is a rapid increase in bone metabolism at the vertebral endplates that develops towards the center of the interbody region. Knowing the local bone metabolism during uncompromised consolidation of spinal interbody fusion might enable identification of impaired bone formation early after LIF surgery using 18F-NaF PET/CT scanning.


Asunto(s)
Vértebras Lumbares , Fusión Vertebral , Animales , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Osteogénesis , Tomografía Computarizada por Tomografía de Emisión de Positrones , Ovinos , Tomografía Computarizada por Rayos X
4.
BMC Musculoskelet Disord ; 23(1): 463, 2022 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-35581630

RESUMEN

INTRODUCTION: Malalignment of the Total Ankle Replacement (TAR) has often been postulated as the main reason for the high incidence of TAR failure. As the ankle joint has a small contact area, stresses are typically high, and malalignment may lead to non-homogeneous stress distributions, including stress peaks that may initiate failure. This study aims to elucidate the effect of TAR malalignment on the contact stresses on the bone-implant interface, thereby gaining more understanding of the potential role of malalignment in TAR failure. METHODS: Finite Element (FE) models of the neutrally aligned as well as malaligned CCI (Ceramic Coated Implant) Evolution TAR implant (Van Straten Medical) were developed. The CCI components were virtually inserted in a generic three-dimensional (3D) reconstruction of the tibia and talus. The tibial and talar TAR components were placed in neutral alignment and in 5° and 10° varus, valgus, anterior and posterior malalignment. Loading conditions of the terminal stance phase of the gait cycle were applied. Peak contact pressure and shear stress at the bone-implant interface were simulated and stress distributions on the bone-implant interface were visualized. RESULTS: In the neutral position, a peak contact pressure and shear stress of respectively 98.4 MPa and 31.9 MPa were found on the tibial bone-implant interface. For the talar bone-implant interface, this was respectively 68.2 MPa and 39.0 MPa. TAR malalignment increases peak contact pressure and shear stress on the bone-implant interface. The highest peak contact pressure of 177 MPa was found for the 10° valgus malaligned tibial component, and the highest shear stress of 98.5 MPa was found for the 10° posterior malaligned talar model. High contact stresses were mainly located at the edges of the bone-implant interface and the fixation pegs of the talar component. CONCLUSIONS: The current study demonstrates that TAR malalignment leads to increased peak stresses. High peak stresses could contribute to bone damage and subsequently reduced implant fixation, micromotion, and loosening. Further research is needed to investigate the relationship between increased contact stresses at the bone-implant interface and TAR failure.


Asunto(s)
Artroplastia de Reemplazo de Tobillo , Articulación del Tobillo/cirugía , Artroplastia de Reemplazo de Tobillo/efectos adversos , Artroplastia de Reemplazo de Tobillo/métodos , Fenómenos Biomecánicos , Interfase Hueso-Implante , Análisis de Elementos Finitos , Humanos , Estrés Mecánico , Tibia/cirugía
6.
Acta Orthop ; 91(2): 159-164, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31928120

RESUMEN

Background and purpose - The uncemented Symax hip stem has shown early proximal ingrowth as result of the BONIT-hydroxyapatite (HA) coating and the distal DOTIZE surface treatment. We evaluated 2-year postoperative radiostereometric analysis (RSA) migration of the Symax hip stem in THA patients. We also investigated the correlation between migration at 4 weeks and clinical outcomes after 2 years.Patients and methods - Patients in a 2-year clinical follow-up single-centre RSA randomized controlled trial were randomized to 2 different cup designs. All 45 patients received a Symax hip stem. RSA migration patterns of the Symax hip stem is presented here as a single cohort. RSA examinations were performed postoperatively, but before weight-bearing, and subsequently after 1, 3, 6, 12, and 24 months. Clinical outcomes and radiographic evaluations were assessed 3, 6, 12, and 24 months postoperatively.Results - During the first 4 weeks, the Symax hip stem subsided, rotated into retroversion, and translated posteriorly, after which the migration ceased and the prosthesis stabilized. All clinical outcomes improved from preoperatively to 2 years. There was no clinically or statistically significant correlation between subsidence and retroversion at 4 weeks and clinical outcomes after 2 years.Interpretation - RSA evaluation of the uncemented Symax hip stem confirms that the design principles and coating properties lead to early stabilization of the stem, as early as 4 weeks postoperatively. There was no correlation between subsidence and retroversion at 4 weeks and clinical outcomes after 2 years. Based on the predictive potential of the RSA technique, we anticipate excellent long-term survival of this hip stem.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Falla de Prótesis/etiología , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Cementación , Materiales Biocompatibles Revestidos , Durapatita , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Diseño de Prótesis , Radiografía , Análisis Radioestereométrico , Rotación , Resultado del Tratamiento
7.
J Mater Sci Mater Med ; 30(8): 94, 2019 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-31414232

RESUMEN

Clinically, S53P4 bioactive glass (BAG) has shown very promising results in bone infection treatment, but it is also known to degrade very slowly in vivo. To evaluate which mechanisms (cellular or dissolution) can play a role in the degradation of S53P4 BAG and S53P4 BAG putty, in vitro degradation experiments at different pH (7.4 and 4.6) were performed. Micro computed tomography showed a rapid dissolution of the synthetic binder in the putty formulation, within 12 h is simulated body fluid (pH = 7.4), leaving behind only loose granules. Therefore the degradation of the loose granules was investigated further. Significant weight loss was observed and ion chromatography showed that Ca2+, Na+ and PO43- ions were released from S54P4 BAG granules in the two fluids. It was observed that the weight loss and ion release were increased when the pH of the fluid was decreased to 4.6. Osteoclasts are known to create such a low pH when resorbing bone and therefore their capacity to degrade S53P4 surfaces were studied as well. Scanning electron microscopy and energy-dispersive X-ray spectroscopy confirmed that osteoclasts were able to create resorption pits in the calcium phosphate layer on S53P4 BAG surfaces. The silica of the BAG, located underneath the calcium phosphate, seemed to hinder further osteclastic resorption of the material. To our knowledge we were the first to observe actively resorbing osteoclasts on S53P4 bioactive glass surfaces, in vitro. Future research is needed to define the specific role osteoclasts play in the degradation of BAG in vivo.


Asunto(s)
Implantes Absorbibles , Sustitutos de Huesos/farmacocinética , Fosfatos de Calcio/farmacocinética , Vidrio , Osteoclastos/fisiología , Adsorción , Sustitutos de Huesos/química , Fosfatos de Calcio/química , Diferenciación Celular , Células Cultivadas , Vidrio/química , Humanos , Ensayo de Materiales , Monocitos/fisiología
8.
BMC Med Imaging ; 17(1): 18, 2017 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-28241752

RESUMEN

BACKGROUND: Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. METHODS: Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. RESULTS: No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. CONCLUSIONS: We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.


Asunto(s)
Placas Óseas/clasificación , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Radio (Anatomía)/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Benzofenonas , Densidad Ósea , Femenino , Curación de Fractura , Humanos , Cetonas , Masculino , Proyectos Piloto , Polietilenglicoles , Polímeros , Radio (Anatomía)/cirugía , Titanio
9.
J Mater Sci Mater Med ; 28(10): 148, 2017 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-28828753

RESUMEN

Loss of sagittal alignment and balance in adult spinal deformity can cause severe pain, disability and progressive neurological deficit. When conservative treatment has failed, spinal fusion using rigid instrumentation is currently the salvage treatment to stop further curve progression. However, fusion surgery is associated with high revision rates due to instrumentation failure and proximal junctional failure, especially if patients also suffer from osteoporosis. To address these drawbacks, a less rigid rod construct is proposed, which is hypothesized to provide a more gradual transition of force and load distribution over spinal segments in comparison to stiff titanium rods. In this study, the effect of variation in rod stiffness on the intradiscal pressure (IDP) of fixed spinal segments during flexion-compression loading was assessed. An ex vivo multisegment (porcine) flexion-compression spine test comparing rigid titanium rods with more flexible polycarbonate-urethane (PCU) rods was used. An increase in peak IDP was found for both the titanium and PCU instrumentation groups as compared to the uninstrumented controls. The peak IDP for the spines instrumented with the PCU rods was significantly lower in comparison to the titanium instrumentation group. These results demonstrated the differences in mechanical load transfer characteristics between PCU and titanium rod constructs when subjected to flexion-compression loading. The concept of stabilization with a less rigid rod may be an alternative to fusion with rigid instrumentation, with the aim of decreasing mechanical stress on the instrumented segments and the possible benefit of a decrease in the incidence of screw pullout.


Asunto(s)
Fijadores Internos , Vértebras Lumbares , Cemento de Policarboxilato , Titanio , Uretano , Animales , Materiales Biocompatibles , Fenómenos Biomecánicos , Ensayo de Materiales , Rango del Movimiento Articular , Fusión Vertebral/instrumentación , Estrés Mecánico , Porcinos
10.
BMC Musculoskelet Disord ; 17: 19, 2016 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-26762175

RESUMEN

BACKGROUND: Despite the growing evidence in the literature there is still a lack of consensus regarding the use of minimally invasive surgical technique (MIS) in total knee arthroplasty (TKA). METHODS: A prospective, randomized, international multicentre trial including 69 patients was performed to compare computer-assisted TKA (CAS-TKA) using either mini-midvastus (MIS group) or standard medial parapatellar approach (conventional group). Patients from 3 centers (Maastricht, Zwickau, Adelaide) with end-stage osteoarthritis of the knee were randomized to either an MIS group with dedicated instrumentation or a conventional group to receive cruciate retaining CAS-TKA without patella resurfacing. The primary outcome was to compare post operative pain and range of motion (ROM). The secondary outcome was to measure the duration of surgery, blood loss, chair rise test, quadriceps strength, anterior knee pain, Knee Society Score (KSS),WOMAC scores, mechanical leg axis and component alignment. RESULTS: Patients in the MIS group (3.97 ± 2.16) had significant more pain at 2 weeks than patients in the conventional group (2.77 ± 1.43) p = 0.003. There was no significant difference in any of the other primary outcome parameters. Surgery time was significantly longer (p < 0.001) and there were significantly higher blood loss (p = 0.002) in the MIS group as compared to the conventional group. The difference of the mean mechanical leg alignment between the groups was not statistically significant (-0.43° (95% CI -1.50-0.64); p = 0.43). There was no significant difference of component alignment between the two surgical groups with respect to flexion/extension (p = 0.269), varus/valgus (p = 0.653) or rotational alignment (p = 0.485) of the femur component and varus valgus alignment (p = 0.778) or posterior slope (p = 0.164) of the tibial component. CONCLUSION: There was no advantage of the MIS approach compared to a conventional approach CAS-TKA in any of the primary outcome measurements assessed, however the MIS approach was associated with longer surgical time and greater blood loss. MIS-TKA in combination with computer navigation is safe in terms of implant positioning. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT02625311 8 December 2015.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Osteoartritis de la Rodilla/cirugía , Rótula/cirugía , Músculo Cuádriceps/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Femenino , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/epidemiología , Estudios Prospectivos
11.
BMC Musculoskelet Disord ; 17: 87, 2016 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-26883741

RESUMEN

BACKGROUND: Both the range of motion (ROM) technique and the tibial tubercle landmark (TTL) technique are frequently used to align the tibial component into proper rotational position during total knee arthroplasty (TKA). The aim of the study was to assess the intra-operative differences in tibial rotation position during computer-navigated primary TKA using either the TTL or ROM techniques. The ROM technique was hypothesized to be a repeatable method and to produce different tibial rotation positions compared to the TTL technique. METHODS: A prospective, observational study was performed to evaluate the antero-posterior axis of the cut proximal tibia using both the ROM and the TTL technique during primary TKA without postoperative clinical assessment. Computer navigation was used to measure this difference in 20 consecutive knees of 20 patients who underwent a posterior stabilized total knee arthroplasty with a fixed-bearing polyethylene insert and a patella resurfacing. RESULTS: The ROM technique is a repeatable method with an interclass correlation coefficient (ICC2) of 0.84 (p < 0.001). The trial tibial baseplate was on average 4.56 degrees externally rotated compared to the tubercle landmark. This difference was statistically significant (p = 0.028). The amount of maximum intra-operative flexion and the pre-operative mechanical axis were positively correlated with the magnitude of difference between the two methods. CONCLUSIONS: It is important for the orthopaedic surgeon to realise that there is a significant difference between the TTL technique and ROM technique when positioning the tibial component in a rotational position. This difference is correlated with high maximum flexion and mechanical axis deviations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Rango del Movimiento Articular/fisiología , Rotación , Tibia/fisiología , Tibia/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
12.
J Arthroplasty ; 31(12): 2773-2777, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27394075

RESUMEN

BACKGROUND: Historically it has been suggested that noise-induced hearing loss (NIHL) affects approximately 50% of the orthopedic surgery personnel. This noise may be partially caused by the use of powered saw systems that are used to make the bone cuts. The first goal was to quantify and compare the noise emission of these different saw systems during total knee arthroplasty (TKA) surgery. A second goal was to estimate the occupational NIHL risk for the orthopedic surgery personnel in TKA surgery by quantifying the total daily noise emission spectrum during TKA surgery and to compare this to the Dutch Occupational Health Organization guidelines. METHODS: A conventional sagittal oscillating blade system with a full oscillating blade and 2 newer oscillating tip saw systems (handpiece and blade) were compared. Noise level measurements during TKA surgery were performed during cutting and hammering, additionally surgery noise profiles were made. RESULTS: The noise level was significantly lower for the oscillating tip saw systems compared to the conventional saw system, but all were in a range that can cause NIHL. The conventional system handpiece produced a considerable higher noise level compared to oscillating tip handpiece. CONCLUSION: NIHL is an underestimated problem in the orthopedic surgery. Solutions for decreasing the risk of hearing loss should be considered. The use of oscillating tip saw systems have a reduced noise emission in comparison with the conventional saw system. The use of these newer systems might be a first step in decreasing hearing loss among the orthopedic surgery personnel.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Huesos/cirugía , Ruido , Exposición Profesional/análisis , Ortopedia/estadística & datos numéricos , Pérdida Auditiva Provocada por Ruido/etiología , Humanos , Ruido/efectos adversos , Exposición Profesional/efectos adversos , Instrumentos Quirúrgicos
13.
AMB Express ; 14(1): 45, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38662284

RESUMEN

Quorum sensing (QS) is a complex communication system in bacteria, directing their response to the environment. QS is also one of the main regulators of bacterial biofilms' formation, maturation and dispersion. Matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging (MSI) is a molecular imaging technique that allows the mapping of QS molecules in bacterial biofilms. Here, we highlight the latest advances in MALDI-MSI in recent years and how this technology can improve QS understanding at the molecular level.

14.
Global Spine J ; 14(2_suppl): 120S-128S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421323

RESUMEN

STUDY DESIGN: Systematic review. OBJECTIVE: Examine the clinical evidence for the use of osteobiologics in hybrid surgery (combined anterior cervical discectomy and fusion (ACDF) and total disc replacement (TDR)) in patients with multilevel cervical degenerative disc disease (DDD). METHODS: PubMed and Embase were searched between January 2000 and August 2020. Clinical studies investigating 18-80 year old patients with multilevel cervical DDD who underwent hybrid surgery with or without the use of osteobiologics were considered eligible. Two reviewers independently screened and assessed the identified articles. The methodological index for non-randomized studies (MINORS) tool and the risk of bias (RoB 2.0) assessment tool were used to assess risk of bias. The Grading of Recommendations, Assessment, Development and Evaluations (GRADE) was used to evaluate quality of evidence across studies per outcome. RESULTS: Eleven studies were included. A decrease in cervical range of motion was observed in most studies for both the hybrid surgery and the control groups consisting of stand-alone ACDF or TDR. Fusion rates of 70-100% were reported in both the hybrid surgery and control groups consisting of stand-alone ACDF. The hybrid surgery group performed better or comparable to the control group in terms of adjacent segment degeneration. Studies reported an improvement in visual analogue scale for pain and neck disability index values after surgery compared to preoperative scores for both treatment groups. The included studies had moderate methodological quality. CONCLUSIONS: There is insufficient evidence for assessing the use of osteobiologics in multilevel hybrid surgery and additional high quality and controlled research is deemed essential.

15.
Global Spine J ; 14(2_suppl): 141S-162S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421332

RESUMEN

STUDY DESIGN: Systematic review. OBJECTIVES: The study's primary objective was to determine how osteobiologic choice affects fusion rates in patients undergoing anterior cervical discectomy and fusion (ACDF). The study's secondary objectives were to 1) determine the optimal timing of fusion assessment following ACDF and 2) determine if osteobiologic type affects the timing and optimal modality of fusion assessment. METHODS: A systematic search of PubMed/MEDLINE was conducted for literature published from 2000 through October 2020 comparing anterior fusion in the cervical spine with various osteobiologics. Both comparative studies and case series of ≥10 patients were included. RESULTS: A total of 74 studies met the inclusion criteria. Seventeen studies evaluated the efficacy of autograft on fusion outcomes, and 23 studies assessed the efficacy of allograft on fusion outcomes. 3 studies evaluated the efficacy of demineralized bone matrix, and seven assessed the efficacy of rhBMP-2 on fusion outcomes. Other limited studies evaluated the efficacy of ceramics and bioactive glasses on fusion outcomes, and 4 assessed the efficacy of stem cell products. Most studies utilized dynamic radiographs for the assessment of fusion. Overall, there was a general lack of supportive data to determine the optimal timing of fusion assessment meaningfully or if osteobiologic type influenced fusion timing. CONCLUSIONS: Achieving fusion following ACDF appears to remain an intricate interplay between host biology and various surgical factors, including the selection of osteobiologics. While alternative osteobiologics to autograft exist and may produce acceptable fusion rates, limitations in study methodology prevent any definitive conclusions from existing literature.

16.
J Orthop Res ; 42(3): 500-511, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38069631

RESUMEN

In vitro and in vivo studies are critical for the preclinical efficacy assessment of novel therapies targeting musculoskeletal infections (MSKI). Many preclinical models have been developed and applied as a prelude to evaluating safety and efficacy in human clinical trials. In performing these studies, there is both a requirement for a robust assessment of efficacy, as well as a parallel responsibility to consider the burden on experimental animals used in such studies. Since MSKI is a broad term encompassing infections varying in pathogen, anatomical location, and implants used, there are also a wide range of animal models described modeling these disparate infections. Although some of these variations are required to adequately evaluate specific interventions, there would be enormous value in creating a unified and standardized criteria to animal testing in the treatment of MSKI. The Treatment Workgroup of the 2023 International Consensus Meeting on Musculoskeletal Infection was responsible for questions related to preclinical models for treatment of MSKI. The main objective was to review the literature related to priority questions and estimate consensus opinion after voting. This document presents that process and results for preclinical models related to (1) animal model considerations, (2) outcome measurements, and (3) imaging.


Asunto(s)
Proyectos de Investigación , Animales , Humanos , Consenso , Modelos Animales
17.
Global Spine J ; 14(2_suppl): 6S-13S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421322

RESUMEN

STUDY DESIGN: Guideline. OBJECTIVES: To develop an international guideline (AOGO) about the use of osteobiologics in anterior cervical discectomy and fusion (ACDF) for treating degenerative spine conditions. METHODS: The guideline development process was guided by AO Spine Knowledge Forum Degenerative (KF Degen) and followed the Guideline International Network McMaster Guideline Development Checklist. The process involved 73 participants with expertise in degenerative spine diseases and surgery from 22 countries. Fifteen systematic reviews were conducted addressing respective key topics and evidence was collected. The methodologist compiled the evidence into GRADE Evidence-to-Decision frameworks. Guideline panel members judged the outcomes and other criteria and made the final recommendations through consensus. RESULTS: Five conditional recommendations were created. A conditional recommendation is about the use of allograft, autograft or a cage with an osteobiologic in primary ACDF surgery. Other conditional recommendations are about the use of osteobiologic for single- or multi-level ACDF, and for hybrid construct surgery. It is suggested that surgeons use other osteobiologics rather than human bone morphogenetic protein-2 (BMP-2) in common clinical situations. Surgeons are recommended to choose 1 graft over another or 1 osteobiologic over another primarily based on clinical situation, and the costs and availability of the materials. CONCLUSION: This AOGO guideline is the first to provide recommendations for the use of osteobiologics in ACDF. Despite the comprehensive searches for evidence, there were few studies completed with small sample sizes and primarily as case series with inherent risks of bias. Therefore, high-quality clinical evidence is demanded to improve the guideline.

18.
J Foot Ankle Res ; 16(1): 40, 2023 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-37353843

RESUMEN

BACKGROUND: Malalignment is often postulated as an important reason for the high failure rate of total ankle replacements (TARs). The correlation between TAR malalignment and clinical outcome, however, is not fully understood. Improving and expanding radiographic TAR alignment measurements in the clinic might lead to a better insight into the correlation between malalignment and the clinical outcome. This study aims to develop and validate a tool to semi-automatic measure TAR alignment, and to improve alignment measurements on radiographs in the clinic. METHODS: A tool to semi-automatically measure TAR alignment on anteroposterior and lateral radiographs was developed in MATLAB. Using the principle of edge contouring and the perpendicular relationship between the anteroposterior and lateral radiographs, the exact configuration of the TAR components can be found. Two observers validated the tool by measuring TAR alignment of ten patients using the tool. The Intraclass Coefficient (ICC) was calculated to assess the reliability of the developed method. The results obtained by the tool were compared to clinical results during radiographic follow-up in the past, and the accuracy of both methods was calculated using three-dimensional CT data. RESULTS: The tool showed an accuracy of 76% compared to 71% for the method used during follow-up. ICC values were 0.94 (p < 0.01) and higher for both inter-and intra-observer reliability. CONCLUSIONS: The tool presents a reproducible method to measure TAR alignment parameters. Three-dimensional alignment parameters are obtained from two-dimensional radiographs, and as the tool can be applied to most TAR designs, it offers a valuable addition in the clinic and for research purposes.


Asunto(s)
Articulación del Tobillo , Artroplastia de Reemplazo de Tobillo , Humanos , Articulación del Tobillo/diagnóstico por imagen , Reproducibilidad de los Resultados , Artroplastia de Reemplazo de Tobillo/métodos , Radiografía
19.
N Am Spine Soc J ; 14: 100231, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37440982

RESUMEN

Background: Adolescent idiopathic scoliosis (AIS) has an estimated general population prevalence of 2% to 3%. The impact of adolescent idiopathic scoliosis (AIS) on the patients' experienced quality of life and psychological well-being and the resulting societal burden are increasingly recognized. However, there is limited knowledge on the economic burden of AIS. This cross-sectional, prevalence-based, bottom-up approach burden of disease study aims to determine the impact associated with adolescent idiopathic scoliosis in terms of the cost-of-illness and health-related quality of life from a societal perspective in the Netherlands. Methods: Persons diagnosed with AIS or parents of a child with AIS that are willing and able to answer the questionnaires will be eligible to participate. Patients will be included consecutively between June until January 2023. Costs and self-perceived health-related quality of life will be estimated using 3 steps: identification, measurement and valuation. To assess the costs associated with AIS the institute for Medical Technology Assessment - Medical Consumption Questionnaire and the institute for Medical Technology Assessment - Productivity Cost Questionnaire will be used. To assess the HRQoL of adult AIS patients the EuroQol 5-dimensions or EuroQol 5-dimensions Youth questionnaire for children under the age of 12 and the Scoliosis Research Society-22 revised questionnaire will be considered. Discussion: This is the first study in this field. It will help raise awareness for AIS and wider support for both the patient community and informal care takers among healthcare professionals and policymakers. Major strengths of this study will be the use of mostly validated, standardized questionnaires. Limitations include the cross-sectional and retrospective nature of the study design.

20.
Heliyon ; 9(6): e16568, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37303579

RESUMEN

In this systematic review, the antimicrobial effect of ion-substituted calcium phosphate biomaterials was quantitatively assessed. The literature was systematically searched up to the 6th of December 2021. Study selection and data extraction was performed in duplo by two independent reviewers with a modified version of the OHAT tool for risk of bias assessment. Any differences were resolved by consensus or by a referee. A mixed effects model was used to investigate the relation between the degree of ionic substitution and bacterial reduction. Of 1016 identified studies, 108 were included in the analysis. The methodological quality of included studies ranged from 6 to 16 out of 18 (average 11.4). Selenite, copper, zinc, rubidium, gadolinium, silver and samarium had a clear antimicrobial effect, with a log reduction in bacteria count of 0.23, 1.8, 2.1, 3.6, 5.8, 7.4 and 10 per atomic% of substitution, respectively. There was considerable between-study variation, which could partially be explained by differences in material formulation, study quality and microbial strain. Future research should focus on clinically relevant scenarios in vitro and the translation to in vivo prevention of PJI.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA