Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Thorac Cardiovasc Surg ; 59(5): 268-73, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21557162

RESUMEN

BACKGROUND: The Aristotle score quantifies the complexity involved in congenital heart surgery. It defines surgical performance as complexity score times hospital survival. We studied how expected and observed surgical performance evolved over time. METHODS: 2312 main procedures carried out between 2006 and 2010 were analyzed. The Aristotle basic score, corresponding hospital survival and related observed surgical performance were estimated. Expected survival was based on the mortality risks published by O'Brien and coauthors. Observed performance divided by expected performance was called the standardized ratio of performance. This should trend towards a figure above 100%. Survival rates and performance are given with 95% confidence intervals. RESULTS: The mean Aristotle basic score was 7.88 ± 2.68. 51 patients died: observed hospital survival was 97.8 % (97.1 %-98.3%). 115 deaths were anticipated: expected survival was 95.2% (93.5%-96.3%). Observed and expected surgical performance reached 7.71 (7.65-7.75) and 7.49 (7.37-7.59), respectively. Therefore the overall standardized ratio of performance was 102.94%. The ratio increased from 2006 (ratio = 101.60%) to 2009 (103.92%) and was 103.42% in 2010. Performance was high for the repair of congenital corrected transposition of the great arteries and ventricular septal defect (VSD) by atrial switch and Rastelli procedure, the Norwood procedure, repair of truncus arteriosus, aortic arch repair and VSD closure, and the Ross-Konno procedure, with corresponding standardized ratios of 123.30%, 116.83%, 112.99%, 110.86% and 110.38%, respectively. With a ratio of 82.87%, performance was low for repair of Ebstein's anomaly. CONCLUSION: The standardized ratio of surgical performance integrates three factors into a single value: procedure complexity, postoperative observed survival, and comparison with expected survival. It constitutes an excellent instrument for quality monitoring of congenital heart surgery programs over time. It allows an accurate comparison of surgical performance across institutions with different case mixes.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas/cirugía , Evaluación de Procesos y Resultados en Atención de Salud , Indicadores de Calidad de la Atención de Salud , Análisis de Varianza , Benchmarking , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Competencia Clínica , Alemania , Cardiopatías Congénitas/mortalidad , Mortalidad Hospitalaria , Humanos , Evaluación de Procesos y Resultados en Atención de Salud/estadística & datos numéricos , Indicadores de Calidad de la Atención de Salud/estadística & datos numéricos , Medición de Riesgo , Factores de Riesgo , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
2.
Ultrasound Obstet Gynecol ; 35(2): 183-90, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20101636

RESUMEN

OBJECTIVE: To evaluate the intrauterine course and outcome of tricuspid atresia detected in the fetus. METHODS: This was a retrospective review of all confirmed cases of tricuspid atresia detected prenatally between 1998 and 2006 in three tertiary referral centers in Germany. RESULTS: Fifty-four cases of tricuspid atresia were detected prenatally during the study period and confirmed postnatally: 28 (51.9%) cases had a concordant ventriculoarterial connection of which 14 also had pulmonary outflow obstruction; 25 (46.3%) cases had a discordant ventriculoarterial connection of which 14 also had aortic outflow obstruction, six had pulmonary outflow tract obstruction and two had other associated intracardiac anomalies; and one (1.9%) had a common arterial trunk. The peak velocity index for veins in the ductus venosus was significantly elevated in 19 of the 37 (51.4%) cases assessed; however, this finding did not correlate with adverse intrauterine outcome. There were associated extracardiac anomalies in 12 cases: five with chromosomal anomalies, two with VACTERL association, one with unilateral renal agenesis, one with hypospadia, one with hydrothorax, one with megacystis and one with agenesis of the ductus venosus. Seventeen of the 54 (31.5%) cases underwent termination of pregnancy, two (3.7%) died in utero, two (3.7%) died in infancy and 33 (61.1%) children survived with a median follow-up of 26 (range, 12-120) months. Prenatal echocardiography correctly anticipated the postnatal course and the need for neonatal intervention in 29/35 (82.9%) continued pregnancies; in the remaining six (17.1%) cases the right outflow tract obstruction had been underestimated. CONCLUSIONS: Tricuspid atresia and the frequently associated intracardiac anomalies can be diagnosed in the fetus with considerable accuracy. A thorough search for extracardiac malformations should be performed in order to rule out chromosomal anomalies and multiple malformation syndromes. Elevated pulsatility in the ductus venosus does not indicate cardiac failure. The short-term overall survival in continued pregnancies in our study exceeded 89%, with the greatest rate of loss being in the first year of postnatal life.


Asunto(s)
Anomalías Múltiples/diagnóstico por imagen , Enfermedades Fetales/diagnóstico por imagen , Corazón Fetal/diagnóstico por imagen , Atresia Tricúspide/diagnóstico por imagen , Anomalías Múltiples/genética , Anomalías Múltiples/mortalidad , Aborto Inducido , Femenino , Enfermedades Fetales/epidemiología , Enfermedades Fetales/genética , Alemania/epidemiología , Edad Gestacional , Humanos , Recién Nacido , Masculino , Embarazo , Resultado del Embarazo , Estudios Retrospectivos , Atresia Tricúspide/genética , Atresia Tricúspide/mortalidad , Ultrasonografía Prenatal
3.
Thorac Cardiovasc Surg ; 58(6): 322-7, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20824582

RESUMEN

BACKGROUND: Hospital costs are expected to correlate with clinical complexity. Do costs for congenital heart surgery correlate with Aristotle complexity scores? METHODS: 442 inpatient stays in 2008 were evaluated. Aristotle scores and levels were determined. Costs were estimated according to the German Institute for Hospital Reimbursement system. Pearson and Spearman R correlation coefficients and corresponding goodness-of-fit regression coefficients R2 were calculated. RESULTS: Mean basic and comprehensive Aristotle scores were 7.60 +/- 2.74 and 9.23 +/- 2.94 points, respectively. Mean expenses per hospital stay amounted to 29,369 +/- 30,823 Euros. Aristotle basic and comprehensive scores and levels were positively correlated with hospital costs. With a Spearman R of 1 and related R2 of 0.9436, scores of the 6 Aristotle comprehensive levels correlated best. Mean hospital reimbursement was 26,412 +/- 17,962 Euros. Compensation was higher than expenses for patients in comprehensive levels 1 to 3, but much lower for those in levels 4 to 6. CONCLUSIONS: Aristotle comprehensive complexity scores were highly correlated with hospital costs. The Aristotle score could be used as a scale to establish the correct reimbursement after congenital heart surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/economía , Cardiopatías Congénitas/economía , Cardiopatías Congénitas/cirugía , Costos de Hospital , Reembolso de Seguro de Salud/economía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Cuidados Críticos/economía , Alemania , Cardiopatías Congénitas/mortalidad , Mortalidad Hospitalaria , Humanos , Lactante , Recién Nacido , Pacientes Internos , Tiempo de Internación/economía , Modelos Económicos , Respiración Artificial/economía , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
4.
Thorac Cardiovasc Surg ; 58(6): 328-32, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20824583

RESUMEN

BACKGROUND: Scores of Aristotle comprehensive complexity (ACC) levels have been demonstrated to correlate with the case-mix index (CMI) (cost-weights) generated by the German Diagnosis-Related Groups (DRG) 2009 version (G-DRG 2009). The equation used was "y = 0.5591 + 0.939 x" whereby y stands for cost-weight and x for ACC score. We hypothesised that each ACC level could be assigned a DRG (ACC DRG) and be used to determine hospital reimbursement. METHODS: 185 patients underwent cardiac surgery between January and June 2009. The ACC scores of these 185 patients were grouped in ACC levels, based on the basic cost-weight value of their DRG. One ACC DRG was assigned to each group and a corresponding cost-weight calculated based on the aforementioned equation. The resulting ACC CMI was compared with the CMI generated by the G-DRG 2009 (G-DRG 2009 CMI). Finally, the ACC surgical performance (complexity x hospital survival) was used to calculate the cost-weight; the obtained CMI was called "effective ACC CMI". RESULTS: Mean ACC score was 9.515 +/- 3.611 points. Derived ACC CMI and related G-DRG 2009 CMI were 9.494 and 8.438, respectively. Hospital survival was 97.8 % (181/184). Therefore ACC surgical performance and "effective ACC CMI" were 9.306 and 9.297, respectively. For each ACC level, the number of patients (n), mean ACC score, ACC CMI and related G-DRG 2009 CMI were as follows: Level 1: n = 25, 4.024 +/- 0.879, 4.338 and 5.911; Level 2: n = 30, 6.563 +/- 0.574, 6.722 and 6.602; Level 3: n = 43, 8.665 +/- 0.540, 8.695 and 8.088; Level 4: n = 73, 11.730 +/- 1.690, 11.574 and 9.612; Level 5: n = 14, 16.710 +/- 1.380, 16.249 and 11.843, respectively. CONCLUSIONS: The Aristotle score can be used to adjust hospital reimbursement by assigning a DRG and cost-weight value to each ACC level. Missing figures for level 6 can be obtained from a previous study which showed a mean score of 22.11 +/- 1.24: the ACC CMI would be 21.320. The 6 ACC DRGs indicate the correct compensation based on the complexity of the procedure. Reimbursement using the German DRG 2009 appears to favour less complex cases, while procedures with a higher complexity are penalised. Reimbursement according to "effective ACC CMIs" would have a strong impact by supporting units providing high-quality care.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/economía , Cardiopatías Congénitas/economía , Cardiopatías Congénitas/cirugía , Costos de Hospital , Reembolso de Seguro de Salud/economía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Alemania , Cardiopatías Congénitas/mortalidad , Mortalidad Hospitalaria , Humanos , Lactante , Recién Nacido , Pacientes Internos , Tiempo de Internación/economía , Modelos Económicos , Respiración Artificial/economía , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
5.
Circulation ; 104(15): 1757-60, 2001 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-11591610

RESUMEN

BACKGROUND: The overall performance of available mechanical intravascular ultrasound catheters for fetal transesophageal echocardiography during fetoscopic fetal cardiac interventions in sheep has been limited by radioelectronic interference, low system frame rates, and low acoustic outputs. Therefore, a more reliable device is desired for human fetoscopic surgical procedures. METHODS AND RESULTS: We assessed the potential of a newly available 10-French phased-array intravascular ultrasound catheter for multimodal fetal transesophageal echocardiography in 5 fetal sheep between 78 and 98 days of gestation (term, 145 to 150 d). The intravascular ultrasound catheter was easily inserted through the mouth into the esophagus in all 5 sheep fetuses (mean weight, 600 g), and it permitted high-quality 2D imaging of the fetal heart in vertical imaging planes that were validated by MRI. Color Doppler and pulsed Doppler imaging permitted clear assessment of fetal cardiovascular flows and recording of velocity-time integral tracings of the fetal heart and great vessels. The vertical imaging planes were particularly useful to demonstrate interventional material inside the fetal heart and great vessels. CONCLUSIONS: Our early experience with the phased-array intravascular ultrasound catheter indicates that multimodal fetal transesophageal echocardiography has now become possible in these smallest of patients.


Asunto(s)
Cateterismo/instrumentación , Ecocardiografía Transesofágica/métodos , Corazón Fetal/diagnóstico por imagen , Feto , Ultrasonografía Prenatal/métodos , Animales , Ecocardiografía Doppler/instrumentación , Ecocardiografía Doppler/métodos , Ecocardiografía Transesofágica/instrumentación , Femenino , Imagen por Resonancia Magnética , Embarazo , Reproducibilidad de los Resultados , Ultrasonografía Doppler en Color/instrumentación , Ultrasonografía Doppler en Color/métodos , Ultrasonografía Prenatal/instrumentación
6.
Circulation ; 100(7): 772-6, 1999 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-10449702

RESUMEN

BACKGROUND: Therapy-refractory supraventricular tachycardia commonly results in hydrops and death in human fetuses. The purpose of this study in fetal sheep was to assess the feasibility of a minimally invasive fetoscopic approach for fetal transesophageal electrocardiography and stimulation aimed at diagnosis and termination of these tachycardias. METHODS AND RESULTS: We studied a total of 10 fetal sheep (87 to 103 days of gestation; term=145 days). We entered the amniotic cavity using a percutaneous fetoscopic approach and placed various electrophysiology catheters into the fetal esophagus. We recorded the number of animals in which fetoscopic transesophageal electrocardiography and stimulation were successful and assessed pacing success and thresholds for different catheters. In addition, we monitored for potential adverse effects from stimulation and for other complications of the operation. Recording of transesophageal electrocardiograms was successful in all fetal sheep. Capture during stimulation was successfully documented by additional fetal bipolar surface electrocardiograms in 7 fetuses. In fetuses in which fetal surface electrocardiograms were not recorded, pacing stimulus artifacts interfered with documentation of capture. Although stimulation thresholds were high, the maternal rhythm was not affected by fetal stimulation. CONCLUSIONS: Fetoscopic fetal transesophageal electrocardiography and stimulation are feasible in fetal sheep. This minimally invasive approach might have the potential to improve diagnosis and management of therapy-refractory supraventricular tachycardias in human fetuses.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Ecocardiografía Transesofágica/métodos , Enfermedades Fetales/diagnóstico por imagen , Corazón Fetal/diagnóstico por imagen , Taquicardia Supraventricular/diagnóstico por imagen , Animales , Estimulación Eléctrica , Estudios de Factibilidad , Femenino , Fetoscopía , Ovinos/embriología , Taquicardia Supraventricular/embriología , Taquicardia Supraventricular/terapia
7.
Circulation ; 102(14): 1602-4, 2000 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-11015334

RESUMEN

BACKGROUND: Fetal cardiac interventions by direct ultrasound-guided approaches or open fetal cardiac surgery have been fraught with technical difficulties, as well as with significant maternal and fetal morbidity in humans. Therefore, the purpose of our study in sheep was to assess the feasibility and potential of fetoscopic direct fetal cardiac access. METHODS AND RESULTS: In 15 anesthetized pregnant ewes (88 to 109 days of gestation; term, 145 days), 3 to 4 trocars were percutaneously placed in the uterus. Using videofetoscopic equipment, we assessed the feasibility of achieving direct fetal cardiac access. Minimally invasive direct fetal cardiac access by operative fetoscopy was achieved in 10 of the 15 fetal sheep. In 7 fetuses, the approach was successfully tested for fetal cardiac pacing (n=5) or antegrade fetal cardiac catheterization (n=2). Access was not achieved in 5 fetuses because of bleeding complications (n=2) or because the fetoscopic setup could not be established (n=3). All but 2 fetal sheep were alive at the end of the procedure. Acute fetal demise resulted from maternal hypotension or kinking of the fetal inferior caval vein by sternal suspension. Six ewes continued gestation; 3 of these went to term, with a normal fetal outcome. Two ewes died from septicemia 3 and 7 days after the procedure, and 1 ewe aborted 1 month after the procedure. CONCLUSIONS: Minimally invasive direct fetal cardiac access by operative fetoscopy is feasible in fetal sheep. The fetoscopic approach carries important potential for fetal cardiac pacing, antegrade fetal valvuloplasties, and resection of fetal intrapericardial teratomas in human fetuses.


Asunto(s)
Corazón Fetal/cirugía , Fetoscopía/métodos , Animales , Cateterismo , Estudios de Factibilidad , Femenino , Ovinos
8.
Am J Cardiol ; 83(5B): 158D-160D, 1999 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-10089859

RESUMEN

Implantable cardioverter defibrillators (ICDs) and ventricular assist devices (VADs) have been used as a bridge to cardiac transplantation. In selected patients, the combined implantation may be required. This study was motivated by a case of a 33-year-old female patient with giant cell myocarditis who died of ventricular tachyarrhythmias after having been placed on a VAD with which she had been treated on an out-of-hospital basis for a prolonged period of time. A subsequent retrospective analysis of our data showed that, of 73 patients who had to be bridged mechanically (54 Novacor, 12 TCI Heartmate, 4 Thoratec, 3 Medos) in our institution between 1993 and 1998, 10 patients had undergone defibrillator implantation either before (n = 8) or after (n = 2) implantation of a VAD. The cases are presented, and the feasibility of the combination therapy discussed.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Trasplante de Corazón , Corazón Auxiliar , Adulto , Terapia Combinada , Muerte Súbita Cardíaca/prevención & control , Femenino , Alemania , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia , Listas de Espera
9.
J Heart Lung Transplant ; 18(10): 927-36, 1999 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10561102

RESUMEN

BACKGROUND: The widely used non-volume-loaded abdominal heterotopic heart transplant (NL) in rats undergoes atrophy after transplantation. Various techniques have been designed to load the transplanted heart because of its potential immunological impact. Our aim was to create a volume-loaded heterotopic heart transplantation model (VL) capable of ejection and practical for routine studies. Using this model, we tested the hypothesis that VL isografts would retain myocardial performance comparable to native hearts (NH). METHODS: Heterotopic hearts were transplanted using and end-to-side anastomosis between the donor's superior vena cava and the recipient's abdominal inferior vena cava. The right ventricle loads the left ventricle (LV) via a direct anastomosis of the pulmonary artery to the left atrium. The LV ejects volume through an end-to-side anastomosis of the donor's aorta to the recipient's abdominal aorta. Hemodynamic data (systolic and diastolic LV pressures, dP/dt max and min, tau) were studied in-situ (at baseline and after adding volume) and in a Langendorff perfusion system (at baseline and after stimulation with isoproterenol) 2 weeks after transplantation. RESULTS: In situ systolic pressure and diastolic function of VL was superior to NL, and beta-adrenergic stimulated performance in the Langendorff perfusion of VL showed hemodynamic performance equivalent to NH, unlike NL which had a diminished response. CONCLUSION: This technique results in a volume-loaded ejecting heart transplant model that preserves anatomical structures. The VL can be evaluated in situ and after explantation in Langendorff perfusion system and may offer advantages if workload of the graft is of significance to the study performed.


Asunto(s)
Trasplante de Corazón/fisiología , Modelos Cardiovasculares , Trasplante Heterotópico/fisiología , Abdomen , Análisis de Varianza , Anastomosis Quirúrgica/métodos , Animales , Cardiotónicos/farmacología , Electrocardiografía/estadística & datos numéricos , Trasplante de Corazón/métodos , Trasplante de Corazón/estadística & datos numéricos , Hemodinámica/efectos de los fármacos , Hemodinámica/fisiología , Isoproterenol/farmacología , Masculino , Ratas , Ratas Endogámicas Lew , Técnicas de Sutura
10.
Ann Thorac Surg ; 70(2): 538-41, 2000 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10969676

RESUMEN

BACKGROUND: Wound necrosis and infection pose a tremendous risk for patients with left ventricular assist devices. METHODS: We analyzed our database of patients with left ventricular assist devices for those who developed wound dehiscence and concomitant infection after left ventricular assist device implantation. RESULTS: Three of our 66 patients (4.5%) with implantable ventricular assist devices had had severe wound complications with necrosis of the abdominal or thoracic wall uncovering part of the device. The predominant impact on the development of these complications was presumably related to multiple surgical interventions on the same site. CONCLUSIONS: Nevertheless, these patients can recover and undergo successful heart transplantation if adequately managed.


Asunto(s)
Corazón Auxiliar , Dehiscencia de la Herida Operatoria/etiología , Infección de la Herida Quirúrgica/etiología , Músculos Abdominales/patología , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Necrosis , Factores de Riesgo
11.
Ann Thorac Surg ; 55(3): 685-93, 1993 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8452431

RESUMEN

Between October 10, 1989, and June 17, 1991, 109 patients with life-threatening ventricular arrhythmias received an implantable cardioverter-defibrillator at our institution. In 50 patients, nonthoracotomy lead systems consisting of a subcutaneous chest wall patch electrode near the cardiac apex and one (Cardiac Pacemakers, Inc: Endotak C) or two (Medtronic: Transvene) transvenous electrodes were tested. The mean ejection fraction was 0.44 +/- 0.15 with a range from 0.19 to 0.81. Twenty-four patients had a history of open heart operation. In 43 patients the nonthoracotomy lead system was implanted, whereas in 7 patients epicardial patch lead systems were required due to elevated defibrillation thresholds during nonthoracotomy lead testing. There was one perioperative death unrelated to the operative procedure (hydrocephalus internus). Hemorrhage from the subcutaneous patch pocket or the device pocket that required reintervention occurred in 4 patients. During a mean follow-up of 13 +/- 5 months (range, 4 to 26 months) no dislocation of an endocardial lead, insulation defect, or lead fracture has been observed. In 1 patient, the lead system had to be removed due to infection of the subcutaneous patch pocket. The cardiovascular survival rate was 98% at 12 and 18 months, and freedom from sudden cardiac death was 100% at 6 and 12 months. In conclusion, defibrillator implantation using nonthoracotomy lead systems is feasible with a success rate of 86%, and during short-term follow-up no problems related to the lead system such as dislocation, fracture, or insulation defect have occurred.


Asunto(s)
Desfibriladores Implantables , Adolescente , Adulto , Anciano , Estimulación Cardíaca Artificial , Enfermedades Cardiovasculares/mortalidad , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Métodos , Persona de Mediana Edad , Complicaciones Posoperatorias , Análisis de Supervivencia , Toracotomía
12.
Clin Nephrol ; 46(1): 59-63, 1996 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8832154

RESUMEN

Renal failure after cardiac surgery using cardiopulmonary bypass (CPB) is well understood for infants, children and adults. The perioperative risk factors after CPB for immature kidneys in newborns are not well known. This retrospective study investigates perioperative risk factors for renal insufficiency in neonates. I) Preoperative: Age; weight, performed angiography, amount of dye used in angiography, renal disease and creatinine. II) Intraoperative: Duration of operation, duration of MAP < 40 mmHg, use of deep hypothermia, in-out fluid balance, duration of CPB, duration of circulatory arrest and cross-clamp time. III) Postoperative: Creatinine, use of catecholamines, use of nitroglycerine (NG) or phosphodiesterase inhibitors (PDI) and additional antibiotics. From Jan. 1990 to Dec. 1994 50 neonates underwent cardiac surgery using CPB (n = 23 transposition of the great arteries; n = 4 pulmonary atresia; n = 6 critical pulmonary stenosis; n = 5 hypoplastic left heart syndrome; n = 3 Ebstein's anomaly; n = 2 interrupted arch with hypoplastic left ventricle; n = 2 single ventricle; n = 1 each: double outlet right ventricle, tricuspid atresia, critical aortic stenosis, rhabdo-myosarkoma, corrected transposition of the great arteries.) Thirty-one patients entered the study. Depending on the postoperative creatinine level two groups (group I: creatinine <1 mg/dl and group II: >1 mg/dl) were created. The diureses between the two groups did not differ. Comparing the patients of group I vs. group II, patients of group I were younger (mean age: 7.7 d. vs. 11.4 d), lighter (mean weight: 3260 g vs. 3430 g), less had angiography (44% vs. 77%), received more dye (mean amount: 14 ml vs. 7 ml), the duration of MAP < 40 mmHg while on CPB was longer (mean duration 3 min vs. 21 min), more patients were operated on using deep hypothermia (55% vs. 27%), the postoperative in-out-fluid balance was more positive (mean balance +413 ml vs. +221 ml), received postop. more frequently high doses of catocholamines and less common NG or PDI, but more often additional antibiotics. The duration of circulatory arrest (mean time: 60 min vs. 55 min) and cross clamp time (mean time: 68 min vs. 65 min) seems not to be a risk factor and vasodilators given simultaneously with catecholamines may have preventive effects on postoperative renal insufficiency. Immature kidneys may play an outstanding role in the susceptibility of damaging factors. Further investigation with a larger number of patients allowing to obtain statistical significant risk factors are required.


Asunto(s)
Puente Cardiopulmonar/efectos adversos , Cardiopatías Congénitas/cirugía , Complicaciones Posoperatorias/etiología , Insuficiencia Renal/etiología , Antibacterianos/uso terapéutico , Catecolaminas/uso terapéutico , Creatinina/metabolismo , Humanos , Recién Nacido , Complicaciones Posoperatorias/metabolismo , Complicaciones Posoperatorias/prevención & control , Insuficiencia Renal/metabolismo , Insuficiencia Renal/prevención & control , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Vasodilatadores/uso terapéutico
13.
Surg Technol Int ; 2: 89-91, 1993 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25951547

RESUMEN

There is no consensus in treating relapsing pneumothorax and pleural effusion. Various types of treatment exist. While open chest surgery with mechanical pleurodesis or pleurectomy is effective, with a recurrence rate close to zero, for patients in poor conditions this treatment may be disadvantageous because of its invasiveness. Therefore minimally invasive techniques using antibiotics, fibrin glue, talcum, kaolin, blood and silver nitrate have been described. Several side effects accompany these agents, and the recurrence rate is between 5-39%. New video-assisted thoracoscopic techniques have enabled surgeons to combine the effectiveness of pleurectomy with minimal invasiveness. Results using these techniques are encouraging. As with open pleurectomy, bleeding complications have been reported, Further disadvantages have to be considered, such as the effect of destroying the parietal layer of the pleura, which may complicate subsequent operations in the thoracic cavity. A technique for avoiding this pleural injury, while maintaining the same efficiency as open pleural abrasion and coagulation is described below.

16.
Arch Dis Child Fetal Neonatal Ed ; 93(4): F261-4, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18252817

RESUMEN

BACKGROUND: Surgical closure of a patent ductus arteriosus (PDA) in very low birth weight (VLBW) infants has been associated with impaired neurodevelopmental outcome. Surgical PDA closure may result in abrupt changes of cerebral haemodynamics. OBJECTIVE: To examine the cerebral blood volume changes occurring after surgical closure of PDA. DESIGN: Continuous cerebral near-infrared spectroscopy (NIRS) recording throughout PDA surgery. SETTING: Tertiary neonatal intensive care unit, with PDA surgery performed on the ward. PATIENTS: Ten VLBW infants, median birth weight 748 g (range 590-1070), gestational age 24 (23-27) weeks, chronological age 14 (12-22) days. INTERVENTION: Surgical closure of PDA. MAIN OUTCOME MEASURES: Changes in cerebral oxygenated haemoglobin, cerebral deoxygenated haemoglobin, and tissue oxygenation index (measured), changes in cerebral blood volume (CBV) and cerebral haemoglobin difference (calculated) as measured by NIRS. RESULTS: During the first 2 minutes after closure of the PDA, CBV increased significantly (mean (SD) 0.14 (0.12) ml/100 g tissue; p = 0.01) and returned to baseline within 2-5 minutes. Cerebral oxygenation did not change. CONCLUSIONS: There is a short-lasting increase in CBV immediately after surgical closure of PDA, but no change in cerebral oxygenation. These transient changes are unlikely to cause harm.


Asunto(s)
Volumen Sanguíneo/fisiología , Encéfalo/irrigación sanguínea , Conducto Arterioso Permeable/fisiopatología , Hemoglobinas/metabolismo , Oxígeno/sangre , Circulación Cerebrovascular/fisiología , Conducto Arterioso Permeable/metabolismo , Conducto Arterioso Permeable/cirugía , Frecuencia Cardíaca , Humanos , Recién Nacido , Recién Nacido de muy Bajo Peso/fisiología , Espectroscopía Infrarroja Corta
17.
Thorac Cardiovasc Surg ; 56(7): 401-5, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18810697

RESUMEN

BACKGROUND: Can Contegra grafts withstand high pressure? METHODS: The function of Contegra grafts implanted after unifocalization of major aortopulmonary collateral arteries (MAPCAs) in 10 patients was evaluated. Median age at repair was 194 days and two conduit sizes were used: 12 mm (n = 8) and 14 mm (n = 2). Echocardiography and heart catheterization findings were reviewed. RESULTS: Two patients died: one early after repair, one late. Death was not graft related. The median duration of observation for survivors was 31 (range 4 - 42) months. The postoperative right ventricular/left ventricular pressure ratio was greater than 75 % in 9 patients. High pressures persisted in 6 survivors. Seven patients underwent interventional dilatation/stenting of pulmonary arteries on 19 occasions. No obstruction was detected in the conduit. Graft valve regurgitation increased in 5 patients, but never exceeded grade 2 (n = 4). Freedom from reoperation for conduit dysfunction/failure was 100 % at month 42. CONCLUSION: At mid-term follow-up, the Contegra grafts withstood high pressure without significant dysfunction or aneurysmal dilatation requiring surgery. Contegra appears to be an acceptable alternative to the aortic homograft for use after unifocalization of MAPCAs in infancy.


Asunto(s)
Bioprótesis , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Venas Yugulares/trasplante , Arteria Pulmonar/cirugía , Anastomosis Quirúrgica , Animales , Presión Sanguínea , Implantación de Prótesis Vascular/efectos adversos , Bovinos , Preescolar , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Lactante , Diseño de Prótesis , Falla de Prótesis , Arteria Pulmonar/fisiopatología , Reoperación , Factores de Tiempo , Resultado del Tratamiento , Presión Ventricular
18.
Pediatr Cardiol ; 24(3): 304-6, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12522653

RESUMEN

Congenital absence of aortic cusps leads to severe aortic regurgitation. We present a newborn with this rare entity with extreme mitral stenosis. Hemodynamic features were those of hypoplastic left heart syndrome. Surgical management consisted of initial modified Norwood procedure followed by orthotopic heart transplantation.


Asunto(s)
Insuficiencia de la Válvula Aórtica/congénito , Insuficiencia de la Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Estenosis de la Válvula Mitral/congénito , Estenosis de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/diagnóstico , Trasplante de Corazón , Humanos , Recién Nacido , Masculino , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico , Reoperación , Resultado del Tratamiento
19.
Pediatr Cardiol ; 24(4): 397-9, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12399906

RESUMEN

The absence of the right superior vena cava (SVC) is usually associated with the presence of a left SVC. This is the first report of a case of systemic venous return without the presence of either upper caval veins. The blood of the upper half of the body was collected into a vessel located on the left side of the spine behind the heart. This vessel crossed over to the right side at the level of the kidneys, draining directly into the inferior vena cava. During correction of tetralogy of Fallot, these findings were confirmed. The terminology and the bearing on interventional planning are discussed.


Asunto(s)
Tetralogía de Fallot/diagnóstico , Tetralogía de Fallot/cirugía , Vena Cava Superior/anomalías , Anomalías Múltiples/diagnóstico , Anomalías Múltiples/cirugía , Angiografía/métodos , Cateterismo Cardíaco/métodos , Puente Cardiopulmonar/métodos , Ecocardiografía Doppler , Electrocardiografía , Estudios de Seguimiento , Hemodinámica/fisiología , Humanos , Lactante , Masculino , Medición de Riesgo , Resultado del Tratamiento
20.
Surg Endosc ; 8(10): 1243-5, 1994 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7809816

RESUMEN

Mainly incited by the bushfirelike spread of endoscopic operative techniques in general surgery, thoracoscopy has become the object of new interest in the field of thoracic surgery. Location and resection of lung tumors are problematic for several reasons and so far not standardized. The main problems are pointed out. A new technique together with the instruments and their advantages is demonstrated. Future aspects are discussed.


Asunto(s)
Neoplasias Pulmonares/cirugía , Toracoscopía/métodos , Humanos , Engrapadoras Quirúrgicas , Toracoscopios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA