Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Emerg Med J ; 38(2): 111-117, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33219133

RESUMEN

BACKGROUND: Concerns over high transmission risk of SARS-CoV-2 have led to innovation and usage of an aerosol box to protect healthcare workers during airway intubation in patients with COVID-19. Its efficacy as a barrier protection in addition to the use of a standard personal protective equipment (PPE) is not fully known. We performed a simulated study to investigate the relationship between aerosol box usage during intubation and contaminations on healthcare workers pre-doffing and post-doffing of PPE. METHODS: This was a randomised cross-over study conducted between 9 April to 5 May 2020 in the ED of University Malaya Medical Centre. Postgraduate Emergency Medicine trainees performed video laryngoscope-assisted intubation on an airway manikin with and without an aerosol box in a random order. Contamination was simulated by nebulised Glo Germ. Primary outcome was number of contaminated front and back body regions pre-doffing and post-doffing of PPE of the intubator and assistant. Secondary outcomes were intubation time, Cormack-Lehane score, number of intubation attempts and participants' feedback. RESULTS: Thirty-six trainees completed the study interventions. The number of contaminated front and back body regions pre-doffing of PPE was significantly higher without the aerosol box (all p values<0.001). However, there was no significant difference in the number of contaminations post-doffing of PPE between using and not using the aerosol box, with a median contamination of zero. Intubation time was longer with the aerosol box (42.5 s vs 35.5 s, p<0.001). Cormack-Lehane scores were similar with and without the aerosol box. First-pass intubation success rate was 94.4% and 100% with and without the aerosol box, respectively. More participants reported reduced mobility and visibility when intubating with the aerosol box. CONCLUSIONS: An aerosol box may significantly reduce exposure to contaminations but with increased intubation time and reduced operator's mobility and visibility. Furthermore, the difference in degree of contamination between using and not using an aerosol box could be offset by proper doffing of PPE.


Asunto(s)
Aerosoles , COVID-19/prevención & control , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Intubación Intratraqueal/instrumentación , Simulación de Paciente , Adulto , Estudios Cruzados , Femenino , Personal de Salud , Humanos , Laringoscopía , Malasia , Masculino , Maniquíes , Equipo de Protección Personal
2.
PLoS One ; 15(4): e0228923, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32236132

RESUMEN

Dengue diagnostics have come a long way. Attempts at breaking away from lab-oriented dengue detection, such as NS1 antigen, IgM or IgG antibodies detection have extensively received numerous coverage. As a result, rapid detection tests (RDTs) have started to gain inroads in medical practice. Rapid detection tests notwithstanding, analysis of blood serum is still a relatively complicated task. This includes the necessity of phlebotomy, centrifugation for blood serum, and other reagent-based tests. Therefore, a non-invasive method of dengue detection was considered. In this study, we present the utility of diffuse reflectance skin spectroscopy (bandwidth of 200-2500nm) on the forearm during the triaging period for dengue screening potential. This is performed with multivariate analysis of 240 triaged febrile/suspected dengue patients. The data is then scrutinized for its clinical validity to be included as either confirmed or probable dengue, or a control group. Based on discriminant analysis of several data normalization models, we can predict the patients' clinical dengue-positivity at ranges of accuracy between ~93-98% depending on mode of the data, with a probably optimal sensitivity and specificity to the clinical diagnosis of ~89% and ~100% respectively. From the outcomes of this study, we recommend further trials with cautious optimism. With these findings, it is hoped that the elusive non-invasive detection of tropical diseases may gain platform in the near future.


Asunto(s)
Dengue/diagnóstico por imagen , Tamizaje Masivo/métodos , Piel/diagnóstico por imagen , Análisis Espectral/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Malasia , Masculino , Persona de Mediana Edad , Análisis Multivariante , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA