Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Angew Chem Int Ed Engl ; 62(26): e202305282, 2023 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-37186156

RESUMEN

Tough and self-healable substrates can enable stretchable electronics long service life. However, for substrates, it still remains a challenge to achieve both high toughness and autonomous self-healing ability at room temperature. Herein, a strategy by using the combined effects between quadruple H-bonding and slidable cross-links is proposed to solve the above issues in the elastomer. The elastomer exhibits high toughness (77.3 MJ m-3 ), fracture energy (≈127.2 kJ m-2 ), and good healing efficiency (91 %) at room temperature. The superior performance is ascribed to the inter and intra crosslinking structures of quadruple H-bonding and polyrotaxanes in the dual crosslinking system. Strain-induced crystallization of PEG in polyrotaxanes also contributes to the high fracture energy of the elastomers. Furthermore, based on the dual cross-linked supramolecular elastomer, a highly stretchable and self-healable electrode containing liquid metal is also fabricated, retaining resistance stability (0.16-0.26 Ω) even at the strain of 1600 %.


Asunto(s)
Rotaxanos , Cristalización , Elastómeros , Electrodos , Electrónica
2.
Small ; 18(19): e2200533, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35388964

RESUMEN

The demand for stretchable electronics with a broader working range is increasing for wide application in wearable sensors and e-skin. However, stretchable conductors based on soft elastomers always exhibit low working range due to the inhomogeneous breakage of the conductive network when stretched. Here, a highly stretchable and self-healable conductor is reported by adopting polyrotaxane and disulfide bonds into the binding layer. The binding layer (PR-SS) builds the bridge between polymer substrates (PU-SS) and silver nanowires (AgNWs). The incorporation of sliding molecules endows the stretchable conductor with a long sensing range (190%) due to the energy dissipation derived from the sliding nature of polyrotaxanes, which is two times higher than the working range (93%) of conductors based on AP-SS without polyrotaxanes. Furthermore, the mechanism of sliding effect for the polyrotaxanes in the elastomers is investigated by SEM for morphological change of AgNWs, in situ small-angle x-ray scattering, as well as stress relaxation experiments. Finally, human-body-related sensing tests and a self-correction system in fitness are designed and demonstrated.


Asunto(s)
Ciclodextrinas , Rotaxanos , Elastómeros/química , Conductividad Eléctrica , Humanos , Polímeros/química
3.
Chempluschem ; 89(7): e202300706, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38567455

RESUMEN

The concept of polyrotaxane comes from the rotaxane structure in the supramolecular field. It is a mechanically interlocked supramolecular assembly composed of linear polymer chains and cyclic molecules. Over recent decades, the synthesis and application of polyrotaxanes have seen remarkable growth. Particularly, cyclodextrin-based polyrotaxanes have been extensively reported due to the low-price raw materials, good biocompatibility, and ease of modification. Hence, it is also one of the most promising mechanically interlocking supramolecules for wide industrialization in the future. Polyrotaxanes are widely introduced into materials such as elastomers, hydrogels, and engineering polymers to improve their mechanical properties or impart functionality to the materials. In these materials, polyrotaxane acts as a slidable cross-linker to dissipate energy through sliding or assist in dispersing stress concentration in the cross-linked network, thereby enhancing the toughness of the materials. Further, the unique sliding-ring effect of cyclodextrin-based polyrotaxanes has pioneered advancements in stretchable electronics and energy storage materials. This includes their innovative use in stretchable conductive composite and binders for anodes, addressing critical challenges in these fields. In this mini-review, our focus is to highlight the current progress and potential wider applications in the future, underlining their transformative impact across various domains of material science.

4.
Phys Med Biol ; 66(22)2021 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-34666327

RESUMEN

Objective.For certain radionuclides that decay through emitting two or more gamma photons consecutively within a short time interval-called cascade gamma-rays, the location where a radiopharmaceutical molecule emits cascade gamma-rays can be identified through coincidence detection of the photons. If each cascade photon is detected through a collimation mechanism, the location of the molecule can be inferred from the intersection of the back-projections of the two photons.Approach.In this work, we report the design and evaluation of a three-dimensional stationary imager based on this concept for imaging distributions of cascade-emitting radionuclides in radiopharmaceutical therapy. The imager was composed of two gamma-ray cameras assembled in an L-shape. Both cameras were NaI(Tl) scintillator based, one with a multi-slit collimator, the other with a multi-pinhole collimator. The field of view (FOV) was 100 mm (∅) × 100 mm (L). Based on the unique characteristics of the cascade coincidence events, we used a direct back-projection algorithm to reconstruct point source images for assessing the imager's intrinsic spatial resolution and the standard maximum likelihood expectation maximization algorithm for reconstructing phantom images.Main results.We evaluated the performance of the imager in both simulated and prototype form with radionuclide177Lu (cascade photon emitter). On the simulated imager, the coincidence detection efficiency at the center of FOV was 3.85 × 10-6, the spatial resolution was 7.0 mm. On the prototype imager, the corresponding values were 3.20 × 10-6and 6.7 mm, respectively. Simulated hot-rod and experimental cardiac phantom studies demonstrate the first three-dimensional cascade gamma coincidence imager is fully functional.


Asunto(s)
Cámaras gamma , Radiofármacos , Fantasmas de Imagen , Fotones , Radioisótopos , Tomografía Computarizada de Emisión de Fotón Único/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA