Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Blood ; 139(3): 413-423, 2022 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-34570876

RESUMEN

Prophylaxis is commonly used to prevent central nervous sy stem (CNS) relapse in diffuse large B-cell lymphoma (DLBCL), with no clear standard of care. We retrospectively evaluated 1162 adult patients across 21 US academic centers with DLBCL or similar histologies who received single-route CNS prophylaxis as part of frontline therapy between 2013 and 2019. Prophylaxis was administered intrathecally(IT) in 894 (77%) and using systemic high-dose methotrexate (HD-MTX) in 236 (20%); 32 patients (3%) switched route due to toxicity and were assessed separately. By CNS-International Prognostic Index (IPI), 18% were considered low-risk, 51% moderate, and 30% high. Double-hit lymphoma (DHL) was confirmed in 243 of 866 evaluable patients (21%). Sixty-four patients (5.7%) had CNS relapse after median 7.1 months from diagnosis, including 15 of 64 (23%) within the first 6 months. There was no significant difference in CNS relapse between IT and HD-MTX recipients (5.4% vs 6.8%, P = .4), including after propensity score matching to account for differences between respective recipient groups. Weighting by CNS-IPI, expected vs observed CNS relapse rates were nearly identical (5.8% vs 5.7%). Testicular involvement was associated with high risk of CNS relapse (11.3%) despite most having lower CNS-IPI scores. DHL did not significantly predict for CNS relapse after single-route prophylaxis, including with adjustment for treatment regimen and other factors. This large study of CNS prophylaxis recipients with DLBCL found no significant difference in CNS relapse rates between routes of administration. Relapse rates among high-risk subgroups remain elevated, and reconsideration of prophylaxis strategies in DLBCL is of critical need.


Asunto(s)
Antimetabolitos Antineoplásicos/uso terapéutico , Neoplasias del Sistema Nervioso Central/prevención & control , Linfoma de Células B Grandes Difuso/prevención & control , Metotrexato/uso terapéutico , Recurrencia Local de Neoplasia/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Antimetabolitos Antineoplásicos/administración & dosificación , Antimetabolitos Antineoplásicos/efectos adversos , Femenino , Humanos , Inyecciones Espinales , Masculino , Metotrexato/administración & dosificación , Metotrexato/efectos adversos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
2.
Int J Popul Data Sci ; 8(1): 2072, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38414546

RESUMEN

Background: Using routinely collected clinical data for observational research is an increasingly important method for data collection, especially when rare outcomes are being explored. The POOL study was commissioned to evaluate the safety of waterbirth in the UK using routine maternity and neonatal clinical data. This paper describes the design, rationale, set-up and pilot for this data linkage study using bespoke methods. Methods: Clinical maternity information systems hold many data items of value for research purposes, but often lack specific data items required for individual studies. This study used the novel method of amending an existing clinical maternity database for the purpose of collecting additional research data fields. In combination with the extraction of existing data fields, this maximised the potential use of existing routinely collected clinical data for research purposes, whilst reducing NHS staff data collection burden.Wellbeing Software®, provider of the Euroking® Maternity Information System, added new study specific data fields to their information system, extracted data from participating NHS sites and transferred data for matching with the National Neonatal Research Database to ascertain outcomes for babies admitted to neonatal units. Study set-up processes were put in place for all sites. The data extraction, linkage and cleaning processes were piloted with one pre-selected NHS site. Results: Twenty-six NHS sites were set-up over 27 months (January 2019 - April 2021). Twenty-four thousand maternity records were extracted from the one NHS site, pertaining to the period January 2015 to March 2019. Data field completeness for maternal and neonatal primary outcomes were mostly acceptable. Neonatal identifiers flowed to the National Neonatal Research Database for successful matching and linkage between maternity and neonatal unit records. Discussion: Piloting the data extraction and linkage highlighted the need for additional governance arrangements, training at NHS sites and new processes for the study team to ensure data quality and confidentiality are upheld during the study. Amending existing NHS electronic information systems and accessing clinical data at scale, is possible, but continues to be a time consuming and a technically challenging exercise.


Asunto(s)
Parto Normal , Recién Nacido , Lactante , Humanos , Femenino , Embarazo , Recolección de Datos/métodos , Exactitud de los Datos , Sistemas de Información , Reino Unido
3.
BMJ Open ; 11(1): e040684, 2021 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-33419905

RESUMEN

INTRODUCTION: Approximately 60 000 (9/100) infants are born into water annually in the UK and this is likely to increase. Case reports identified infants with water inhalation or sepsis following birth in water and there is a concern that women giving birth in water may sustain more complex perineal trauma. There have not been studies large enough to show whether waterbirth increases these poor outcomes. The POOL Study (ISRCTN13315580) plans to answer the question about the safety of waterbirths among women who are classified appropriate for midwifery-led intrapartum care. METHODS AND ANALYSIS: A cohort study with a nested qualitative component. Objectives will be answered using retrospective and prospective data captured in electronic National Health Service (NHS) maternity and neonatal systems. The qualitative component aims to explore factors influencing pool use and waterbirth; data will be gathered via discussion groups, interviews and case studies of maternity units. ETHICS AND DISSEMINATION: The protocol has been approved by NHS Wales Research Ethics Committee (18/WA/0291) the transfer of identifiable data has been approved by Health Research Authority Confidentiality Advisory Group (18CAG0153).Study findings and innovative methodology will be disseminated through peer-reviewed journals, conferences and events. Results will be of interest to the general public, clinical and policy stakeholders in the UK and will be disseminated accordingly.


Asunto(s)
Parto Normal , Estudios de Cohortes , Femenino , Humanos , Lactante , Recién Nacido , Madres , Embarazo , Estudios Prospectivos , Estudios Retrospectivos , Medicina Estatal , Gales
4.
Front Psychiatry ; 12: 729129, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34992552

RESUMEN

Background: Parents of children with intellectual disabilities are likely to experience poorer mental well-being and face challenges accessing support. Early Positive Approaches to Support (E-PAtS) is a group-based programme, co-produced with parents and professionals, based on existing research evidence and a developmental systems approach to support parental mental well-being. The aim of this study was to assess the feasibility of community service provider organisations delivering E-PAtS to parents/family caregivers of young children with intellectual disability, to inform a potential definitive randomised controlled trial of the effectiveness and cost-effectiveness of E-PAtS. Methods: This study was a feasibility cluster randomised controlled trial, with embedded process evaluation. Up to two parents/family caregivers of a child (18 months to <6 years old) with intellectual disability were recruited at research sites and allocated to intervention (E-PAtS and usual practise) or control (usual practise) on a 1:1 basis at cluster (family) level. Data were collected at baseline and 3 and 12 months' post-randomisation. The following feasibility outcomes were assessed: participant recruitment rates and effectiveness of recruitment pathways; retention rates; intervention adherence and fidelity; service provider recruitment rates and willingness to participate in a future trial; barriers and facilitating factors for recruitment, engagement, and intervention delivery; and feasibility of collecting outcome measures. Results: Seventy-four families were randomised to intervention or control (n = 37). Retention rates were 72% at 12 months post-randomisation, and completion of the proposed primary outcome measure (WEMWBS) was 51%. Recruitment of service provider organisations and facilitators was feasible and intervention implementation acceptable. Adherence to the intervention was 76% and the intervention was well-received by participants; exploratory analyses suggest that adherence and attendance may be associated with improved well-being. Health economic outcome measures were collected successfully and evidence indicates that linkage with routine data would be feasible in a future trial. Conclusions: The E-PAtS Feasibility RCT has demonstrated that the research design and methods of intervention implementation are generally feasible. Consideration of the limitations of this feasibility trial and any barriers to conducting a future definitive trial, do however, need to be considered by researchers. Clinical Trial Registration: https://www.isrctn.com, identifier: ISRCTN70419473.

5.
Midwifery ; 79: 102554, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31610360

RESUMEN

OBJECTIVE: To identify factors influencing the use of birth pools. DESIGN: Online discussion groups and semi-structured interviews, analysed thematically. SETTING: United Kingdom. PARTICIPANTS: 85 women and 21 midwives took part in online discussion groups; 14 medical staff participated in interviews. FINDINGS: Factors influencing the use of birth pools were grouped into three overarching categories: resources, unit culture and guidelines, and staff endorsement. Resources encompassed pool availability, efficiency of pool use and availability of waterproof cardiotocograph equipment. Unit culture and guidelines related to eligibility criteria for pool use, medicalisation of birth and differences between midwifery-led and obstetric-led care. Staff endorsement encompassed attitudes towards pool use. KEY CONCLUSIONS: Accessibility of birth pools was often limited by eligibility criteria. While midwifery-led units were generally supportive of pool use, obstetric-led units were described as an over-medicalised environment in which pool use was restricted and relied on maternal request. IMPLICATIONS FOR PRACTICE: Midwives can improve women's access to birth pools by providing information antenatally and proactively offering this as an option in labour. Maternity units should work to implement evidence-based guidelines on pool use, increase pool availability (even where there appears to be low demand), and enhance awareness amongst medical staff of the benefits of water immersion.


Asunto(s)
Actitud del Personal de Salud , Parto Obstétrico/métodos , Inmersión , Trabajo de Parto , Partería , Madres , Prioridad del Paciente , Atención Prenatal , Femenino , Humanos , Entrevistas como Asunto , Cuerpo Médico , Enfermeras Obstetrices , Embarazo , Medicina Estatal , Reino Unido
6.
BMJ Case Rep ; 20152015 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-26063106

RESUMEN

A 61-year-old Caucasian man with hypertension and hepatitis C presented to the emergency department with 7 days of productive cough and low-grade fevers despite outpatient therapy with oral azithromycin. On initial evaluation, he was lethargic with peripheral cyanosis and oxygen saturation in the low 70 s on room air, necessitating endotracheal intubation. Chest imaging revealed diffuse bilateral infiltrates compatible with the diagnosis of acute respiratory distress syndrome. Patient subsequently developed profound hypoxaemia and on day 2 of admission, veno-veno extracorporeal membrane oxygenation (ECMO) was initiated. Bronchoscopy revealed a necrotic ulcer on the posterior wall of the left mainstem bronchus, compatible with a bronchial-oesophageal fistula, which was later confirmed by endoscopy, and stented. Histology revealed poorly differentiated squamous cell carcinoma of the lung. Despite stenting of the fistula and ECMO support, the patient expired 5 days after admission.


Asunto(s)
Fístula Bronquial/etiología , Carcinoma de Células Escamosas/complicaciones , Fístula Esofágica/etiología , Neoplasias Pulmonares/complicaciones , Pulmón/patología , Bronquios/patología , Broncoscopía , Oxigenación por Membrana Extracorpórea , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Síndrome de Dificultad Respiratoria/etiología , Síndrome de Dificultad Respiratoria/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA