RESUMEN
In this Letter, we present the design and performance of the frequency-dependent squeezed vacuum source that will be used for the broadband quantum noise reduction of the Advanced Virgo Plus gravitational-wave detector in the upcoming observation run. The frequency-dependent squeezed field is generated by a phase rotation of a frequency-independent squeezed state through a 285 m long, high-finesse, near-detuned optical resonator. With about 8.5 dB of generated squeezing, up to 5.6 dB of quantum noise suppression has been measured at high frequency while close to the filter cavity resonance frequency, the intracavity losses limit this value to about 2 dB. Frequency-dependent squeezing is produced with a rotation frequency stability of about 6 Hz rms, which is maintained over the long term. The achieved results fulfill the frequency dependent squeezed vacuum source requirements for Advanced Virgo Plus. With the current squeezing source, considering also the estimated squeezing degradation induced by the interferometer, we expect a reduction of the quantum shot noise and radiation pressure noise of up to 4.5 dB and 2 dB, respectively.
RESUMEN
OBJECTIVE: Major salivary gland ultrasonography (SGUS) is widely used for the diagnosis of primary Sjögren's syndrome (pSS). Our objective was to assess the contribution of SGUS compared to other items of the 2016 ACR/EULAR pSS classification criteria, based on expert opinion. METHODS: A secure web-based relational database was used by 24 experts from 14 countries to assess 512 realistic vignettes developed from data of patients with suspected pSS. Each vignette provided classification criteria items and information on history, clinical symptoms and SGUS findings. Each expert assessed 64 vignettes, and each vignette was assessed by 3 experts. A diagnosis of pSS was defined according to at least 2 of 3 experts. Validation was performed in the independent French DiapSS cohort of patients with suspected pSS. RESULTS: A criteria-based pSS diagnosis and SGUS findings were independently associated with an expert diagnosis of pSS (P < 0.001). The derived diagnostic weights of individual items in the 2016 ACR/EULAR criteria including SGUS were as follows: anti-SSA, 3; focus score ≥ 1, 3; SGUS score ≥ 2, 1; positive Schirmer's test, 1; dry mouth, 1; and salivary flow rate < 0.1 mL/min, 1. The corrected C statistic area under the curve for the new weighted score was 0.96. Adding SGUS improves the sensitivity from 90.2 % to 95.6% with a quite similar specificity 84.1% versus 82.6%. Results were similar in the DiapSS cohort: adding SGUS improves the sensitivity from 87% to 93%. CONCLUSION: SGUS had similar weight compared to minor items, and its addition improves the performance of the 2016 ACR/EULAR classification criteria.
Asunto(s)
Glándulas Salivales/diagnóstico por imagen , Síndrome de Sjögren/clasificación , Síndrome de Sjögren/diagnóstico por imagen , Ultrasonografía/métodos , Algoritmos , HumanosRESUMEN
The quantum radiation pressure and the quantum shot noise in laser-interferometric gravitational wave detectors constitute a macroscopic manifestation of the Heisenberg inequality. If quantum shot noise can be easily observed, the observation of quantum radiation pressure noise has been elusive, so far, due to the technical noise competing with quantum effects. Here, we discuss the evidence of quantum radiation pressure noise in the Advanced Virgo gravitational wave detector. In our experiment, we inject squeezed vacuum states of light into the interferometer in order to manipulate the quantum backaction on the 42 kg mirrors and observe the corresponding quantum noise driven displacement at frequencies between 30 and 70 Hz. The experimental data, obtained in various interferometer configurations, is tested against the Advanced Virgo detector quantum noise model which confirmed the measured magnitude of quantum radiation pressure noise.
RESUMEN
Current interferometric gravitational-wave detectors are limited by quantum noise over a wide range of their measurement bandwidth. One method to overcome the quantum limit is the injection of squeezed vacuum states of light into the interferometer's dark port. Here, we report on the successful application of this quantum technology to improve the shot noise limited sensitivity of the Advanced Virgo gravitational-wave detector. A sensitivity enhancement of up to 3.2±0.1 dB beyond the shot noise limit is achieved. This nonclassical improvement corresponds to a 5%-8% increase of the binary neutron star horizon. The squeezing injection was fully automated and over the first 5 months of the third joint LIGO-Virgo observation run O3 squeezing was applied for more than 99% of the science time. During this period several gravitational-wave candidates have been recorded.
RESUMEN
At sites of chronic inflammation, recruited immune cells form structures that resemble secondary lymphoid organs (SLOs). Those are characterized by segregated areas of prevalent T- or B-cell aggregation, differentiation of high endothelial venules (HEVs) and local activation of resident stromal cells. B-cell proliferation and affinity maturation towards locally displayed autoantigens have been demonstrated at those sites, known as tertiary lymphoid structures (TLSs). TLS formation has been associated with local disease persistence and progression as well as increased systemic manifestations. While bearing a similar histological structure to SLO, the signals that regulate TLS and SLO formation can diverge, and a series of pro-inflammatory cytokines has been ascribed as responsible for TLS formation at different anatomical sites. Here we review the structural elements as well as the signals responsible for TLS aggregation, aiming to provide an overview to this complex immunological phenomenon.
Asunto(s)
Estructuras Linfoides Terciarias/metabolismo , Estructuras Linfoides Terciarias/patología , Animales , Humanos , Terapia Molecular Dirigida , Estructuras Linfoides Terciarias/inmunologíaRESUMEN
Following a major upgrade, the two advanced detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO) held their first observation run between September 2015 and January 2016. With a strain sensitivity of 10^{-23}/sqrt[Hz] at 100 Hz, the product of observable volume and measurement time exceeded that of all previous runs within the first 16 days of coincident observation. On September 14, 2015, the Advanced LIGO detectors observed a transient gravitational-wave signal determined to be the coalescence of two black holes [B. P. Abbott et al., Phys. Rev. Lett. 116, 061102 (2016)], launching the era of gravitational-wave astronomy. The event, GW150914, was observed with a combined signal-to-noise ratio of 24 in coincidence by the two detectors. Here, we present the main features of the detectors that enabled this observation. At full sensitivity, the Advanced LIGO detectors are designed to deliver another factor of 3 improvement in the signal-to-noise ratio for binary black hole systems similar in mass to GW150914.
RESUMEN
The LIGO detection of the gravitational wave transient GW150914, from the inspiral and merger of two black holes with masses â³30M_{â}, suggests a population of binary black holes with relatively high mass. This observation implies that the stochastic gravitational-wave background from binary black holes, created from the incoherent superposition of all the merging binaries in the Universe, could be higher than previously expected. Using the properties of GW150914, we estimate the energy density of such a background from binary black holes. In the most sensitive part of the Advanced LIGO and Advanced Virgo band for stochastic backgrounds (near 25 Hz), we predict Ω_{GW}(f=25 Hz)=1.1_{-0.9}^{+2.7}×10^{-9} with 90% confidence. This prediction is robustly demonstrated for a variety of formation scenarios with different parameters. The differences between models are small compared to the statistical uncertainty arising from the currently poorly constrained local coalescence rate. We conclude that this background is potentially measurable by the Advanced LIGO and Advanced Virgo detectors operating at their projected final sensitivity.
RESUMEN
On September 14, 2015 at 09:50:45 UTC the two detectors of the Laser Interferometer Gravitational-Wave Observatory simultaneously observed a transient gravitational-wave signal. The signal sweeps upwards in frequency from 35 to 250 Hz with a peak gravitational-wave strain of 1.0×10(-21). It matches the waveform predicted by general relativity for the inspiral and merger of a pair of black holes and the ringdown of the resulting single black hole. The signal was observed with a matched-filter signal-to-noise ratio of 24 and a false alarm rate estimated to be less than 1 event per 203,000 years, equivalent to a significance greater than 5.1σ. The source lies at a luminosity distance of 410(-180)(+160) Mpc corresponding to a redshift z=0.09(-0.04)(+0.03). In the source frame, the initial black hole masses are 36(-4)(+5)Mâ and 29(-4)(+4)Mâ, and the final black hole mass is 62(-4)(+4)Mâ, with 3.0(-0.5)(+0.5)Mâc(2) radiated in gravitational waves. All uncertainties define 90% credible intervals. These observations demonstrate the existence of binary stellar-mass black hole systems. This is the first direct detection of gravitational waves and the first observation of a binary black hole merger.
RESUMEN
On September 14, 2015, the Laser Interferometer Gravitational-Wave Observatory (LIGO) detected a gravitational-wave transient (GW150914); we characterize the properties of the source and its parameters. The data around the time of the event were analyzed coherently across the LIGO network using a suite of accurate waveform models that describe gravitational waves from a compact binary system in general relativity. GW150914 was produced by a nearly equal mass binary black hole of masses 36_{-4}^{+5}M_{â} and 29_{-4}^{+4}M_{â}; for each parameter we report the median value and the range of the 90% credible interval. The dimensionless spin magnitude of the more massive black hole is bound to be <0.7 (at 90% probability). The luminosity distance to the source is 410_{-180}^{+160} Mpc, corresponding to a redshift 0.09_{-0.04}^{+0.03} assuming standard cosmology. The source location is constrained to an annulus section of 610 deg^{2}, primarily in the southern hemisphere. The binary merges into a black hole of mass 62_{-4}^{+4}M_{â} and spin 0.67_{-0.07}^{+0.05}. This black hole is significantly more massive than any other inferred from electromagnetic observations in the stellar-mass regime.
RESUMEN
We report the observation of a gravitational-wave signal produced by the coalescence of two stellar-mass black holes. The signal, GW151226, was observed by the twin detectors of the Laser Interferometer Gravitational-Wave Observatory (LIGO) on December 26, 2015 at 03:38:53 UTC. The signal was initially identified within 70 s by an online matched-filter search targeting binary coalescences. Subsequent off-line analyses recovered GW151226 with a network signal-to-noise ratio of 13 and a significance greater than 5σ. The signal persisted in the LIGO frequency band for approximately 1 s, increasing in frequency and amplitude over about 55 cycles from 35 to 450 Hz, and reached a peak gravitational strain of 3.4_{-0.9}^{+0.7}×10^{-22}. The inferred source-frame initial black hole masses are 14.2_{-3.7}^{+8.3}M_{â} and 7.5_{-2.3}^{+2.3}M_{â}, and the final black hole mass is 20.8_{-1.7}^{+6.1}M_{â}. We find that at least one of the component black holes has spin greater than 0.2. This source is located at a luminosity distance of 440_{-190}^{+180} Mpc corresponding to a redshift of 0.09_{-0.04}^{+0.03}. All uncertainties define a 90% credible interval. This second gravitational-wave observation provides improved constraints on stellar populations and on deviations from general relativity.
RESUMEN
The LIGO detection of GW150914 provides an unprecedented opportunity to study the two-body motion of a compact-object binary in the large-velocity, highly nonlinear regime, and to witness the final merger of the binary and the excitation of uniquely relativistic modes of the gravitational field. We carry out several investigations to determine whether GW150914 is consistent with a binary black-hole merger in general relativity. We find that the final remnant's mass and spin, as determined from the low-frequency (inspiral) and high-frequency (postinspiral) phases of the signal, are mutually consistent with the binary black-hole solution in general relativity. Furthermore, the data following the peak of GW150914 are consistent with the least-damped quasinormal mode inferred from the mass and spin of the remnant black hole. By using waveform models that allow for parametrized general-relativity violations during the inspiral and merger phases, we perform quantitative tests on the gravitational-wave phase in the dynamical regime and we determine the first empirical bounds on several high-order post-Newtonian coefficients. We constrain the graviton Compton wavelength, assuming that gravitons are dispersed in vacuum in the same way as particles with mass, obtaining a 90%-confidence lower bound of 10^{13} km. In conclusion, within our statistical uncertainties, we find no evidence for violations of general relativity in the genuinely strong-field regime of gravity.
RESUMEN
We present a possible observing scenario for the Advanced LIGO and Advanced Virgo gravitational-wave detectors over the next decade, with the intention of providing information to the astronomy community to facilitate planning for multi-messenger astronomy with gravitational waves. We determine the expected sensitivity of the network to transient gravitational-wave signals, and study the capability of the network to determine the sky location of the source. We report our findings for gravitational-wave transients, with particular focus on gravitational-wave signals from the inspiral of binary neutron-star systems, which are considered the most promising for multi-messenger astronomy. The ability to localize the sources of the detected signals depends on the geographical distribution of the detectors and their relative sensitivity, and 90% credible regions can be as large as thousands of square degrees when only two sensitive detectors are operational. Determining the sky position of a significant fraction of detected signals to areas of 5 deg2 to 20 deg2 will require at least three detectors of sensitivity within a factor of â¼ 2 of each other and with a broad frequency bandwidth. Should the third LIGO detector be relocated to India as expected, a significant fraction of gravitational-wave signals will be localized to a few square degrees by gravitational-wave observations alone.
RESUMEN
Artificial insemination is extensively performed in pig farms in Europe, the United States and Canada. Antibiotics are typically added to the inseminating dose to limit bacterial growth during liquid phase storage at 16°C, as bacterial contamination is unavoidable. The World Organization for Animal Health (OIE) and the Food and Agriculture Organization (FAO) take action to control and reduce antibiotic use in animals as more bacteria are becoming resistant to antimicrobials. To avoid the use of antibiotics, we prepared inseminating doses using microfiltered seminal plasma (SP). Microfiltration is a common technology used to reduce bacterial contamination but may retain seminal substances, influencing sperm quality during storage. Therefore, the aim of this study was to evaluate the morphofunctional parameters of spermatozoa during storage at 16°C in doses prepared with or without microfiltered SP, with or without the addition of antibiotics, in a Latin square design. Artificial insemination doses with microfiltered SP and without antibiotic addition preserved spermatozoa viability, mitochondrial membrane potential, acrosome integrity and objective motility, with absolute values equal or even better than those observed in conventional doses. In conclusion, although the results could be considered preliminary due to the small sample size, this study suggests that microfiltration of SP can be a simple method, feasible on farms, to replace antibiotic use in extended doses stored in the liquid phase at 16°C for up to 7 days.
Asunto(s)
Antibacterianos , Filtración/métodos , Semen , Espermatozoides/efectos de los fármacos , Porcinos , Animales , Masculino , Preservación de Semen/métodos , Preservación de Semen/veterinaria , Espermatozoides/fisiologíaRESUMEN
Bleeding phenotype in factor XI (FXI)-deficient patients is variable, and not related to baseline FXI:Act. Aims of our study were to describe the characteristics and the management of surgery and deliveries in FXI-deficient patients, and to investigate the relationship between the haemorrhagic phenotype and the baseline FXI:Act. Ninety-five patients were diagnosed and followed in our centre for a median follow-up of 0.9 years (0.1-36.2); median FXI:Act of all patients: 38% (0.5-69%). Fifty-six patients (59%) experienced bleeding episodes not surgery-related. Prior to diagnosis, 64 patients underwent 132 surgeries, and after diagnosis, 23 patients underwent 36 surgeries. Globally 26 of 168 surgeries were prophylactically treated, whereas 142 of 168 were not. As regard as surgeries performed without prophylaxis, 30 bleeding events (21%) occurred in 21 patients. At diagnosis, the median FXI:Act of bleeding and non-bleeding patients was 28% and 37%, respectively, without statistically significant difference between the two groups (P = 0.26). As regard as surgeries performed under prophylactic treatment just 1 bleeding event occurred. Prior to diagnosis, 31 spontaneous deliveries (SD) and eight caesarian sections (CS) were performed without prophylaxis: 4 postpartum haemorrhages (10.5%) occurred (patients FXI:Act: 2%, 6%, 27%, 52.3% respectively). After diagnosis, four SD and five CS were performed with prophylaxis: no postpartum haemorrhages occurred. We confirm the wide bleeding phenotype variability in FXI-deficient patients, not related to the baseline FXI:Act levels. We highlight the importance of performing a correct diagnosis and follow-up, because a good management of prophylactic treatment, dramatically reduces the bleeding rate in case of surgery or deliveries.
Asunto(s)
Deficiencia del Factor XI/tratamiento farmacológico , Factor XI/uso terapéutico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Pérdida de Sangre Quirúrgica/prevención & control , Cesárea , Niño , Preescolar , Femenino , Hemostasis Quirúrgica , Humanos , Lactante , Masculino , Persona de Mediana Edad , Fenotipo , Hemorragia Posparto/prevención & control , Embarazo , Estudios Retrospectivos , Adulto JovenRESUMEN
A stochastic background of gravitational waves is expected to arise from a superposition of a large number of unresolved gravitational-wave sources of astrophysical and cosmological origin. It should carry unique signatures from the earliest epochs in the evolution of the Universe, inaccessible to standard astrophysical observations. Direct measurements of the amplitude of this background are therefore of fundamental importance for understanding the evolution of the Universe when it was younger than one minute. Here we report limits on the amplitude of the stochastic gravitational-wave background using the data from a two-year science run of the Laser Interferometer Gravitational-wave Observatory (LIGO). Our result constrains the energy density of the stochastic gravitational-wave background normalized by the critical energy density of the Universe, in the frequency band around 100 Hz, to be <6.9 x 10(-6) at 95% confidence. The data rule out models of early Universe evolution with relatively large equation-of-state parameter, as well as cosmic (super)string models with relatively small string tension that are favoured in some string theory models. This search for the stochastic background improves on the indirect limits from Big Bang nucleosynthesis and cosmic microwave background at 100 Hz.
RESUMEN
We present the results of a search for gravitational waves associated with 223 γ-ray bursts (GRBs) detected by the InterPlanetary Network (IPN) in 2005-2010 during LIGO's fifth and sixth science runs and Virgo's first, second, and third science runs. The IPN satellites provide accurate times of the bursts and sky localizations that vary significantly from degree scale to hundreds of square degrees. We search for both a well-modeled binary coalescence signal, the favored progenitor model for short GRBs, and for generic, unmodeled gravitational wave bursts. Both searches use the event time and sky localization to improve the gravitational wave search sensitivity as compared to corresponding all-time, all-sky searches. We find no evidence of a gravitational wave signal associated with any of the IPN GRBs in the sample, nor do we find evidence for a population of weak gravitational wave signals associated with the GRBs. For all IPN-detected GRBs, for which a sufficient duration of quality gravitational wave data are available, we place lower bounds on the distance to the source in accordance with an optimistic assumption of gravitational wave emission energy of 10(-2)Mâc(2) at 150 Hz, and find a median of 13 Mpc. For the 27 short-hard GRBs we place 90% confidence exclusion distances to two source models: a binary neutron star coalescence, with a median distance of 12 Mpc, or the coalescence of a neutron star and black hole, with a median distance of 22 Mpc. Finally, we combine this search with previously published results to provide a population statement for GRB searches in first-generation LIGO and Virgo gravitational wave detectors and a resulting examination of prospects for the advanced gravitational wave detectors.
RESUMEN
Gravitational waves from a variety of sources are predicted to superpose to create a stochastic background. This background is expected to contain unique information from throughout the history of the Universe that is unavailable through standard electromagnetic observations, making its study of fundamental importance to understanding the evolution of the Universe. We carry out a search for the stochastic background with the latest data from the LIGO and Virgo detectors. Consistent with predictions from most stochastic gravitational-wave background models, the data display no evidence of a stochastic gravitational-wave signal. Assuming a gravitational-wave spectrum of Ω_{GW}(f)=Ω_{α}(f/f_{ref})^{α}, we place 95% confidence level upper limits on the energy density of the background in each of four frequency bands spanning 41.5-1726 Hz. In the frequency band of 41.5-169.25 Hz for a spectral index of α=0, we constrain the energy density of the stochastic background to be Ω_{GW}(f)<5.6×10^{-6}. For the 600-1000 Hz band, Ω_{GW}(f)<0.14(f/900 Hz)^{3}, a factor of 2.5 lower than the best previously reported upper limits. We find Ω_{GW}(f)<1.8×10^{-4} using a spectral index of zero for 170-600 Hz and Ω_{GW}(f)<1.0(f/1300 Hz)^{3} for 1000-1726 Hz, bands in which no previous direct limits have been placed. The limits in these four bands are the lowest direct measurements to date on the stochastic background. We discuss the implications of these results in light of the recent claim by the BICEP2 experiment of the possible evidence for inflationary gravitational waves.
RESUMEN
Cosmic strings can give rise to a large variety of interesting astrophysical phenomena. Among them, powerful bursts of gravitational waves (GWs) produced by cusps are a promising observational signature. In this Letter we present a search for GWs from cosmic string cusps in data collected by the LIGO and Virgo gravitational wave detectors between 2005 and 2010, with over 625 days of live time. We find no evidence of GW signals from cosmic strings. From this result, we derive new constraints on cosmic string parameters, which complement and improve existing limits from previous searches for a stochastic background of GWs from cosmic microwave background measurements and pulsar timing data. In particular, if the size of loops is given by the gravitational backreaction scale, we place upper limits on the string tension Gµ below 10(-8) in some regions of the cosmic string parameter space.