Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 216
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anesthesiology ; 140(3): 578-584, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38349754

RESUMEN

Extracorporeal Circulation in Neonatal Respiratory Failure: A Prospective Randomized Study. By RH Bartlett, DW Roloff, RG Cornell, AF Andrews, PW Dillon, JB Zwischenberger. Pediatrics 1985; 76:479-87. Extracorporeal membrane oxygenation (ECMO) is the use of mechanical devices to replace cardiac and pulmonary function in critical care. In the 1960s, laboratory research showed that extracorporeal circulation could be maintained for days using a membrane oxygenator. In the 1970s, the first clinical trials showed that ECMO could sustain life in severe cardiac and pulmonary failure for days or weeks, leading to organ recovery. From 1980 to 2000, ECMO became standard practice for neonatal and pediatric respiratory and cardiac failure. The critical clinical trial was a prospective randomized trial of ECMO in newborn respiratory failure, published in 1985. This is the classic article reviewed in this publication. This was the first use of a randomized, adaptive design trial to minimize the potential ethical dilemma inherent to clinical trials in which the endpoint is death. Other randomized trials followed, and ECMO is now standard practice for severe respiratory and cardiac failure in all age groups.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Insuficiencia Respiratoria , Recién Nacido , Humanos , Niño , Estudios Prospectivos , Corazón , Insuficiencia Cardíaca/terapia , Insuficiencia Respiratoria/terapia , Ensayos Clínicos Controlados Aleatorios como Asunto
2.
Pediatr Res ; 95(1): 93-101, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37087539

RESUMEN

BACKGROUND: Clinical translation of the extracorporeal artificial placenta (AP) is impeded by the high risk for intracranial hemorrhage in extremely premature newborns. The Nitric Oxide Surface Anticoagulation (NOSA) system is a novel non-thrombogenic extracorporeal circuit. This study aims to test the NOSA system in the AP without systemic anticoagulation. METHODS: Ten extremely premature lambs were delivered and connected to the AP. For the NOSA group, the circuit was coated with DBHD-N2O2/argatroban, 100 ppm nitric oxide was blended into the sweep gas, and no systemic anticoagulation was given. For the Heparin control group, a non-coated circuit was used and systemic anticoagulation was administered. RESULTS: Animals survived 6.8 ± 0.6 days with normal hemodynamics and gas exchange. Neither group had any hemorrhagic or thrombotic complications. ACT (194 ± 53 vs. 261 ± 86 s; p < 0.001) and aPTT (39 ± 7 vs. 69 ± 23 s; p < 0.001) were significantly lower in the NOSA group than the Heparin group. Platelet and leukocyte activation did not differ significantly from baseline in the NOSA group. Methemoglobin was 3.2 ± 1.1% in the NOSA group compared to 1.6 ± 0.6% in the Heparin group (p < 0.001). CONCLUSIONS: The AP with the NOSA system successfully supported extremely premature lambs for 7 days without significant bleeding or thrombosis. IMPACT: The Nitric Oxide Surface Anticoagulation (NOSA) system provides effective circuit-based anticoagulation in a fetal sheep model of the extracorporeal artificial placenta (AP) for 7 days. The NOSA system is the first non-thrombogenic circuit to consistently obviate the need for systemic anticoagulation in an extracorporeal circuit for up to 7 days. The NOSA system may allow the AP to be implemented clinically without systemic anticoagulation, thus greatly reducing the intracranial hemorrhage risk for extremely low gestational age newborns. The NOSA system could potentially be applied to any form of extracorporeal life support to reduce or avoid systemic anticoagulation.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Nacimiento Prematuro , Trombosis , Embarazo , Humanos , Femenino , Ovinos , Animales , Óxido Nítrico , Placenta/fisiología , Heparina , Hemorragia/complicaciones , Trombosis/prevención & control , Anticoagulantes/farmacología , Hemorragias Intracraneales/complicaciones
3.
Perfusion ; : 2676591241240725, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38519444

RESUMEN

INTRODUCTION: A radical paradigm shift in the treatment of premature infants failing conventional treatment is to recreate fetal physiology using an extracorporeal Artificial Placenta (AP). The aim of this study is to evaluate the effects of changing fetal hemoglobin percent (HbF%) on physiology and circuit function during AP support in an ovine model. METHODS: Extremely premature lambs (n = 5) were delivered by cesarean section at 117-121 d estimated gestational age (EGA) (term = 145d), weighing 2.5 ± 0.35 kg. Lambs were cannulated using 10-14Fr cannulae for drainage via the right jugular vein and reinfusion via the umbilical vein. Lambs were intubated and lungs were filled with perfluorodecalin to a meniscus with a pressure of 5-8 cm H2O. The first option for transfusion was fetal whole blood from twins followed by maternal red blood cells. Arterial blood gases were used to titrate AP support to maintain fetal blood gas values. RESULTS: The mean survival time on circuit was 119.6 ± 39.5 h. Hemodynamic parameters and lactate were stable throughout. As more adult blood transfusions were given to maintain hemoglobin at 10 mg/dL, the HbF% declined, reaching 40% by post operative day 7. The HbF% was inversely proportional to flow rates as higher flows were required to maintain adequate oxygen saturation and perfusion. CONCLUSIONS: Transfusion of adult blood led to decreased fetal hemoglobin concentration during AP support. The HbF% was inversely proportional to flow rates. Future directions include strategies to decrease the priming volume and establishing a fetal blood bank to have blood rich in HbF.

4.
Crit Care Med ; 51(2): 164-181, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36661447

RESUMEN

On the 50th anniversary of the Society of Critical Care Medicine's journal Critical Care Medicine, critical care pioneers reflect on the importance of the journal to their careers and to the development of the field of adult and pediatric critical care.


Asunto(s)
Cuidados Críticos , Publicaciones Periódicas como Asunto , Sociedades Médicas , Adulto , Niño , Humanos , Aniversarios y Eventos Especiales
5.
Lancet ; 396(10257): 1071-1078, 2020 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-32987008

RESUMEN

BACKGROUND: Multiple major health organisations recommend the use of extracorporeal membrane oxygenation (ECMO) support for COVID-19-related acute hypoxaemic respiratory failure. However, initial reports of ECMO use in patients with COVID-19 described very high mortality and there have been no large, international cohort studies of ECMO for COVID-19 reported to date. METHODS: We used data from the Extracorporeal Life Support Organization (ELSO) Registry to characterise the epidemiology, hospital course, and outcomes of patients aged 16 years or older with confirmed COVID-19 who had ECMO support initiated between Jan 16 and May 1, 2020, at 213 hospitals in 36 countries. The primary outcome was in-hospital death in a time-to-event analysis assessed at 90 days after ECMO initiation. We applied a multivariable Cox model to examine whether patient and hospital factors were associated with in-hospital mortality. FINDINGS: Data for 1035 patients with COVID-19 who received ECMO support were included in this study. Of these, 67 (6%) remained hospitalised, 311 (30%) were discharged home or to an acute rehabilitation centre, 101 (10%) were discharged to a long-term acute care centre or unspecified location, 176 (17%) were discharged to another hospital, and 380 (37%) died. The estimated cumulative incidence of in-hospital mortality 90 days after the initiation of ECMO was 37·4% (95% CI 34·4-40·4). Mortality was 39% (380 of 968) in patients with a final disposition of death or hospital discharge. The use of ECMO for circulatory support was independently associated with higher in-hospital mortality (hazard ratio 1·89, 95% CI 1·20-2·97). In the subset of patients with COVID-19 receiving respiratory (venovenous) ECMO and characterised as having acute respiratory distress syndrome, the estimated cumulative incidence of in-hospital mortality 90 days after the initiation of ECMO was 38·0% (95% CI 34·6-41·5). INTERPRETATION: In patients with COVID-19 who received ECMO, both estimated mortality 90 days after ECMO and mortality in those with a final disposition of death or discharge were less than 40%. These data from 213 hospitals worldwide provide a generalisable estimate of ECMO mortality in the setting of COVID-19. FUNDING: None.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/terapia , Oxigenación por Membrana Extracorpórea , Neumonía Viral/terapia , Insuficiencia Respiratoria/terapia , Adulto , COVID-19 , Estudios de Cohortes , Infecciones por Coronavirus/complicaciones , Infecciones por Coronavirus/mortalidad , Cuidados Críticos , Femenino , Mortalidad Hospitalaria , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/complicaciones , Neumonía Viral/mortalidad , Sistema de Registros , Insuficiencia Respiratoria/mortalidad , Insuficiencia Respiratoria/virología , SARS-CoV-2 , Resultado del Tratamiento
6.
Crit Care Med ; 49(9): 1375-1388, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34259654

RESUMEN

The history of cardiopulmonary resuscitation and the Society of Critical Care Medicine have much in common, as many of the founders of the Society of Critical Care Medicine focused on understanding and improving outcomes from cardiac arrest. We review the history, the current, and future state of cardiopulmonary resuscitation.


Asunto(s)
Reanimación Cardiopulmonar/historia , Reanimación Cardiopulmonar/métodos , Reanimación Cardiopulmonar/tendencias , Cuidados Críticos/métodos , Cuidados Críticos/organización & administración , Historia del Siglo XX , Humanos
7.
Ann Emerg Med ; 78(1): 92-101, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33541748

RESUMEN

STUDY OBJECTIVE: Outcomes of extracorporeal cardiopulmonary resuscitation (ECPR) for out-of-hospital cardiac arrest depend on time to therapy initiation. We hypothesize that it would be feasible to select refractory out-of-hospital cardiac arrest patients for expedited transport based on real-time estimates of the 911 call to the emergency department (ED) arrival interval, and for emergency physicians to rapidly initiate ECPR in eligible patients. METHODS: In a 2-tiered emergency medical service with an ECPR-capable primary destination hospital, adults with refractory shockable or witnessed out-of-hospital cardiac arrest were randomized 4:1 to expedited transport or standard care if the predicted 911 call to ED arrival interval was less than or equal to 30 minutes. The primary outcomes were the proportion of subjects with 911 call to ED arrival less than or equal to 30 minutes and ED arrival to ECPR flow less than or equal to 30 minutes. RESULTS: Of 151 out-of-hospital cardiac arrest 911 calls, 15 subjects (10%) were enrolled. Five of 12 subjects randomized to expedited transport had an ED arrival time of less than or equal to 30 minutes (overall mean 32.5 minutes [SD 7.1]), and 5 were eligible for and treated with ECPR. Three of 5 ECPR-treated subjects had flow initiated in less than or equal to 30 minutes of ED arrival (overall mean 32.4 minutes [SD 10.9]). No subject in either group survived with a good neurologic outcome. CONCLUSION: The Extracorporeal Cardiopulmonary Resuscitation for Refractory Out-of-Hospital Cardiac Arrest trial did not meet predefined feasibility outcomes for selecting out-of-hospital cardiac arrest patients for expedited transport and initiating ECPR in the ED. Additional research is needed to improve the accuracy of predicting the 911 call to ED arrival interval, optimize patient selection, and reduce the ED arrival to ECPR flow interval.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Servicios Médicos de Urgencia , Paro Cardíaco Extrahospitalario/terapia , Servicio de Urgencia en Hospital , Estudios de Factibilidad , Femenino , Humanos , Masculino , Michigan , Persona de Mediana Edad , Tiempo de Tratamiento
8.
Anal Chem ; 92(20): 13641-13646, 2020 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-32955253

RESUMEN

In this letter, the innate ability of nitric oxide (NO) to inhibit platelet activation/adhesion/thrombus formation is employed to improve the hemocompatibility and in vivo accuracy of an intravascular (IV) potentiometric PCO2 (partial pressure of carbon dioxide) sensor. The catheter-type sensor is fabricated by impregnating a segment of dual lumen silicone tubing with a proton ionophore, plasticizer, and lipophilic cation-exchanger. Subsequent filling of bicarbonate and strong buffer solutions and placement of Ag/AgCl reference electrode wires within each lumen, respectively, enables measurement of the membrane potential difference across the inner wall of the tube, with this potential changing as a function of the logarithm of sample PCO2. The dual lumen device is further encapsulated within a S-nitroso-N-acetyl-DL-penicillamine (SNAP)-doped silicone tube that releases physiological levels of NO. The NO releasing sensor exhibits near-Nernstian sensitivity toward PCO2 (slope = 59.31 ± 0.78 mV/decade) and low drift rates (<2 mV/24 h after initial equilibration). In vivo evaluation of the NO releasing sensors, performed in the arteries and veins of anesthetized pigs for 20 h, shows enhanced accuracy (vs non-NO releasing sensors) when benchmarked to measurements of discrete blood samples made with a commercial blood gas analyzer. The accurate, continuous monitoring of blood PCO2 levels achieved with this new IV NO releasing PCO2 sensor configuration could help better manage hospitalized patients in critical care units.


Asunto(s)
Materiales Biocompatibles/química , Dióxido de Carbono/análisis , Óxido Nítrico/metabolismo , Potenciometría/métodos , Animales , Vasos Sanguíneos/química , Electrodos , Resinas de Intercambio Iónico/química , Potenciometría/instrumentación , S-Nitroso-N-Acetilpenicilamina/química , Siliconas/química , Porcinos
9.
Anesthesiology ; 132(5): 1257-1276, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32149776

RESUMEN

This review focuses on the use of veno-venous extracorporeal membrane oxygenation for respiratory failure across all blood flow ranges. Starting with a short overview of historical development, aspects of the physiology of gas exchange (i.e., oxygenation and decarboxylation) during extracorporeal circulation are discussed. The mechanisms of phenomena such as recirculation and shunt playing an important role in daily clinical practice are explained.Treatment of refractory and symptomatic hypoxemic respiratory failure (e.g., acute respiratory distress syndrome [ARDS]) currently represents the main indication for high-flow veno-venous-extracorporeal membrane oxygenation. On the other hand, lower-flow extracorporeal carbon dioxide removal might potentially help to avoid or attenuate ventilator-induced lung injury by allowing reduction of the energy load (i.e., driving pressure, mechanical power) transmitted to the lungs during mechanical ventilation or spontaneous ventilation. In the latter context, extracorporeal carbon dioxide removal plays an emerging role in the treatment of chronic obstructive pulmonary disease patients during acute exacerbations. Both applications of extracorporeal lung support raise important ethical considerations, such as likelihood of ultimate futility and end-of-life decision-making. The review concludes with a brief overview of potential technical developments and persistent challenges.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Intercambio Gaseoso Pulmonar/fisiología , Insuficiencia Respiratoria/fisiopatología , Insuficiencia Respiratoria/terapia , Animales , Dióxido de Carbono/fisiología , Circulación Extracorporea/métodos , Humanos , Respiración Artificial/métodos , Lesión Pulmonar Inducida por Ventilación Mecánica/etiología , Lesión Pulmonar Inducida por Ventilación Mecánica/fisiopatología
10.
Crit Care ; 23(1): 36, 2019 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-30736845

RESUMEN

BACKGROUND: The Extracorporeal Life Support Organization (ELSO) Maastricht Treaty for Nomenclature in Extracorporeal Life Support (ECLS) established consensus nomenclature and abbreviations for ECLS to ensure accurate, concise communication. METHODS: We build on this consensus nomenclature by layering a framework of precise and efficient abbreviations for cannula configuration that describe flow direction, number of cannulae used, any additional ECLS-related catheters, and cannulation sites. This work is a consensus of international representatives of the ELSO, including those from the North American, Latin American, European, South and West Asian, and Asian-Pacific chapters of ELSO. RESULTS: The classification increases in descriptive capability by introducing a third (cannula tip position) and fourth (cannula dimension) level to those provided in the previous consensus on ECLS cannulation configuration nomenclature. This expansion offers the simplest level needed to convey cannulation information yet allows for more details when required. CONCLUSIONS: A complete nomenclature for ECLS cannulation configurations accommodating future revisions was developed to facilitate ability to compare practices and results, to promote efficient communication, and to improve quality of registry data.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Oxigenación por Membrana Extracorpórea/tendencias , Sociedades/tendencias , Cateterismo/métodos , Cateterismo/tendencias , Oxigenación por Membrana Extracorpórea/clasificación , Humanos , Terminología como Asunto
11.
Am J Respir Crit Care Med ; 198(4): 447-451, 2018 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-29614239

RESUMEN

Extracorporeal life support (ECLS) was developed more than 50 years ago, initially with venoarterial and subsequently with venovenous configurations. As the technique of ECLS significantly improved and newer skills developed, complexity in terminology and advances in cannula design led to some misunderstanding of and inconsistency in definitions, both in clinical practice and in scientific research. This document is a consensus of multispecialty international representatives of the Extracorporeal Life Support Organization, including the North America, Latin America, EuroELSO, South West Asia and Africa, and Asia-Pacific chapters, imparting a global perspective on ECLS. The goal is to provide a consistent and unambiguous nomenclature for ECLS and to overcome the inconsistent use of abbreviations for ECLS cannulation. Secondary benefits are ease of multicenter collaboration in research, improved registry data quality, and clear communication among practitioners and researchers in the field.


Asunto(s)
Oxigenación por Membrana Extracorpórea/clasificación , Oxigenación por Membrana Extracorpórea/métodos , Terminología como Asunto , Consenso , Humanos
12.
Perfusion ; 33(4): 249-253, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29090614

RESUMEN

INTRODUCTION: Commercial membrane lungs are designed to transfer a specific amount of oxygen per unit of venous blood flow. Membrane lungs are much more efficient at removing CO2 than adding oxygen, but the range of CO2 transfer is rarely reported. METHODS: Commercial membrane lungs were studied with the goal of evaluating CO2 removal capacity. CO2 removal was measured in 4 commercial membrane lungs under standardized conditions. CONCLUSION: CO2 clearance can be greater than 4 times that of oxygen at a given blood flow when the gas to blood flow ratio is elevated to 4:1 or 8:1. The CO2 clearance was less dependent on surface area and configuration than oxygen transfer. Any ECMO system can be used for selective CO2 removal.


Asunto(s)
Dióxido de Carbono/aislamiento & purificación , Oxigenación por Membrana Extracorpórea/instrumentación , Velocidad del Flujo Sanguíneo , Dióxido de Carbono/sangre , Diseño de Equipo , Humanos , Oxígeno/sangre
13.
Perfusion ; 33(7): 538-545, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29638199

RESUMEN

INTRODUCTION: Cardiopulmonary bypass (CPB) is known to cause a systemic inflammatory and immune response. OBJECTIVE: An in-vitro model of cardiotomy suction was designed to quantify the effects of incrementally increased air-blood exposure on leucocyte marker CD11b and cytokine activation in two common anticoagulants, heparin and citrate. METHODS: Fresh human blood was exposed to increasing amounts of air flow for ten minutes. Leucocyte and cytokine levels were measured prior to and after ten minutes of air flow. Cytokine levels were also measured after air exposure when incubated for 24 hours at 37oC. RESULTS: Leucocyte activation, measured by CD11b, was elevated between baseline and air flow rates up to 50 mL/min. After 10 minutes of air exposure, no measured cytokine levels were elevated. After 24 hours of incubation, cytokine levels of TNFα, IL-10, IL-6, and IL-8 were elevated. However, only IL-8 was significantly elevated in citrated blood, but not in heparinized blood, when compared to baseline samples that were also incubated for 24 hours. CONCLUSION: This study investigates CD11b levels in response to an air stimulus in blood that was anticoagulated with citrate or heparin. Exposure to an air stimulus activates leucocytes. Activation of CD11b was less when using heparin as an anticoagulant compared to citrate. Cytokine activation occurs with air stimulation, but levels do not immediately rise, indicating that time is required to generate free cytokines.


Asunto(s)
Puente Cardiopulmonar/métodos , Citocinas/metabolismo , Leucocitos/metabolismo , Succión/métodos , Humanos
14.
J Pediatr ; 182: 107-113, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28041665

RESUMEN

OBJECTIVES: To assess the current attitudes of extracorporeal membrane oxygenation (ECMO) program directors regarding eligibility for ECMO among children with cardiopulmonary failure. STUDY DESIGN: Electronic cross-sectional survey of ECMO program directors at ECMO centers worldwide within the Extracorporeal Life Support Organization directory (October 2015-December 2015). RESULTS: Of 733 eligible respondents, 226 (31%) completed the survey, 65% of whom routinely cared for pediatric patients. There was wide variability in whether respondents would offer ECMO to any of the 5 scenario patients, ranging from 31% who would offer ECMO to a child with trisomy 18 to 76% who would offer ECMO to a child with prolonged cardiac arrest and indeterminate neurologic status. Even physicians practicing the same specialty sometimes held widely divergent opinions, with 50% of pediatric intensivists stating they would offer ECMO to a child with severe developmental delay and 50% stating they would not. Factors such as quality of life and neurologic status influenced decision making and were used to support decisions for and against offering ECMO. CONCLUSIONS: ECMO program directors vary widely in whether they would offer ECMO to various children with cardiopulmonary failure. This heterogeneity in physician decision making underscores the need for more evidence that could eventually inform interinstitutional guidelines regarding patient selection for ECMO.


Asunto(s)
Actitud del Personal de Salud , Oxigenación por Membrana Extracorpórea/métodos , Paro Cardíaco/terapia , Adolescente , Estudios Transversales , Toma de Decisiones , Femenino , Humanos , Lactante , Masculino , Encuestas y Cuestionarios
15.
Mol Pharm ; 14(11): 3762-3771, 2017 11 06.
Artículo en Inglés | MEDLINE | ID: mdl-29020775

RESUMEN

A new portable gas phase nitric oxide (NO) generator is described for potential applications in inhaled NO (INO) therapy and during cardiopulmonary bypass (CPB) surgery. In this system, NO is produced at the surface of a large-area mesh working electrode by electrochemical reduction of nitrite ions in the presence of a soluble copper(II)-ligand electron transfer mediator complex. The NO generated is then transported into gas phase by either direct purging with nitrogen/air or via circulating the electrolyte/nitrite solution through a gas extraction silicone fiber-based membrane-dialyzer assembly. Gas phase NO concentrations can be tuned in the range of 5-1000 ppm (parts per million by volume for gaseous species), in proportion to a constant cathodic current applied between the working and counter electrodes. This new NO generation process has the advantages of rapid production times (5 min to steady-state), high Faraday NO production efficiency (ca. 93%), excellent stability, and very low cost when using air as the carrier gas for NO (in the membrane dialyzer configuration), enabling the development of potentially portable INO devices. In this initial work, the new system is examined for the effectiveness of gaseous NO to reduce the systemic inflammatory response (SIR) during CPB, where 500 ppm of NO added to the sweep gas of the oxygenator or to the cardiotomy suction air in a CPB system is shown to prevent activation of white blood cells (granulocytes and monocytes) during extracorporeal circulation with cardiotomy suction conducted with five pigs.


Asunto(s)
Puente Cardiopulmonar/métodos , Óxido Nítrico/uso terapéutico , Administración por Inhalación , Animales , Electroquímica/métodos , Pulmón/metabolismo , Nitritos/química , Porcinos
16.
J Intensive Care Med ; 32(4): 243-248, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27040797

RESUMEN

Management of gas exchange using extracorporeal membrane oxygenation (ECMO) in respiratory failure is very different than management when the patient is dependent on mechanical ventilation. All the gas exchange occurs in the membrane lung, and the arterial oxygenation is the result of mixing the ECMO blood with the native venous blood. To manage patients on ECMO, it is essential to understand the physiology described in this essay.


Asunto(s)
Anemia/terapia , Análisis de los Gases de la Sangre/métodos , Oxigenación por Membrana Extracorpórea , Pulmón/metabolismo , Intercambio Gaseoso Pulmonar/fisiología , Insuficiencia Respiratoria/terapia , Anemia/metabolismo , Anemia/fisiopatología , Humanos , Pulmón/fisiopatología , Respiración Artificial , Insuficiencia Respiratoria/metabolismo , Insuficiencia Respiratoria/fisiopatología
17.
J Intensive Care Med ; 32(7): 411-420, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27509917

RESUMEN

In the past the only option for the treatment of respiratory failure due to acute exacerbation of chronic obstructive pulmonary disease (aeCOPD) was invasive mechanical ventilation. In recent decades, the potential for extracorporeal carbon dioxide (CO2) removal has been realized. We review the various types of extracorporeal CO2 removal, outline the optimal use of these therapies for aeCOPD, and make suggestions for future controlled trials. We also describe the advantages and requirements for an ideal long-term ambulatory CO2 removal system for palliation of COPD.


Asunto(s)
Dióxido de Carbono/sangre , Circulación Extracorporea/tendencias , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Insuficiencia Respiratoria/terapia , Progresión de la Enfermedad , Circulación Extracorporea/métodos , Oxigenación por Membrana Extracorpórea , Predicción , Humanos , Insuficiencia Respiratoria/sangre , Insuficiencia Respiratoria/etiología
18.
Compos B Eng ; 121: 23-33, 2017 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-28989300

RESUMEN

Stable and long-term nitric oxide (NO) releasing polymeric materials have many potential biomedical applications. Herein, we report the real-time observation of the crystallization process of the NO donor, S-nitroso-N-acetylpenicillamine (SNAP), within a thermoplastic silicone-polycarbonate-urethane biomedical polymer, CarboSil 20 80A. It is demonstrated that the NO release rate from this composite material is directly correlated with the surface area that the CarboSil polymer film is exposed to when in contact with aqueous solution. The decomposition of SNAP in solution (e.g. PBS, ethanol, THF, etc.) is a pseudo-first-order reaction proportional to the SNAP concentration. Further, catheters fabricated with this novel NO releasing composite material are shown to exhibit significant effects on preventing biofilm formation on catheter surface by Pseudomonas aeruginosa and Proteus mirabilis grown in CDC bioreactor over 14 days, with a 2 and 3 log-unit reduction in number of live bacteria on their surfaces, respectively. Therefore, the SNAP-CarboSil composite is a promising new material to develop antimicrobial catheters, as well as other biomedical devices.

19.
Ann Surg ; 263(3): 573-81, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26625136

RESUMEN

OBJECTIVE: To examine the outcomes of prolonged (≥14 days) extracorporeal membrane oxygenation (P-ECMO) for adult severe respiratory failure and to assess characteristics associated with survival. BACKGROUND: The use of ECMO for treatment of severe respiratory adult patients is associated with overall survival rates of 50% to 70% with median ECMO duration of 10 days. No prior multi-institutional studies have examined outcomes of P-ECMO for severe respiratory failure. METHODS: Data on all adult (≥18 years) patients who required P-ECMO for severe respiratory failure from 1989 to 2013 were extracted from the Extracorporeal Life Support Organization international multi-institutional registry. We examined outcomes over 23 years and compared the 2 more recent time periods of 1989 to 2006 versus 2007 to 2013. RESULTS: Up to 974 patients, mean age 40.2 (18-83) years, had ECMO duration of mean 25.2 days/median 21.0 days (range: 14-208 days). Venovenous ECMO support was most common (venovenous: 79.5%, venoarterial: 9.9%). Reason for ECMO discontinuation included native lung recovery (54%), organ failure (23.7%), family request (6.7%), hemorrhage (2.7%), and diagnosis incompatible with life (5.6%). Forty patients (4.1%) underwent lung transplant with 50% postoperative in-hospital mortality. Increased prevalence of P-ECMO was noted with 72% (701/974) of all cases reported since 2008. Survival to hospital discharge was 45.4% (443/974) and did not vary with ECMO duration. Multivariate logistic regression analysis confirmed that P-ECMO patients 2007 to 2013 had a lower risk of death [odds ratio (OR): 0.650; 95% confidence interval (CI), 0.454-0.929; P = 0.010] compared with 1989 to 2006. Factors independently associated with survival were younger age (OR: 0.983; 95% CI, 0.974-0.993; P < 0.001) and lower PaCO2 (OR, 0.991; 95% CI, 0.986-0.996; P < 0.001). CONCLUSIONS: Prolonged ECMO use for adult respiratory failure was associated with a lower (45.4%) hospital survival rate, compared with prior reported survival rates of short duration ECMO. Prolonged ECMO survival significantly increased in recent years, and increasing ECMO duration did not alter the survival fraction in the 1989 to 2013 study cohort. Although P-ECMO survival rates are less than short ECMO runs, P-ECMO support is justified.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Respiratoria/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Riesgo , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
20.
Crit Care Med ; 44(2): e58-69, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26488218

RESUMEN

OBJECTIVE: To investigate the effects of the combination of extracorporeal cardiopulmonary resuscitation and thrombolytic therapy on the recovery of vital organ function after prolonged cardiac arrest. DESIGN: Laboratory investigation. SETTING: University laboratory. SUBJECTS: Pigs. INTERVENTIONS: Animals underwent 30-minute untreated ventricular fibrillation cardiac arrest followed by extracorporeal cardiopulmonary resuscitation for 6 hours. Animals were allocated into two experimental groups: t-extracorporeal cardiopulmonary resuscitation (t-ECPR) group, which received streptokinase 1 million units, and control extracorporeal cardiopulmonary resuscitation (c-ECPR), which did not receive streptokinase. In both groups, the resuscitation protocol included the following physiologic targets: mean arterial pressure greater than 70 mm Hg, cerebral perfusion pressure greater than 50 mm Hg, PaO2 150 ± 50 torr (20 ± 7 kPa), PaCO2 40 ± 5 torr (5 ± 1 kPa), and core temperature 33°C ± 1°C. Defibrillation was attempted after 30 minutes of extracorporeal cardiopulmonary resuscitation. MEASUREMENTS AND MAIN RESULTS: A cardiac resuscitability score was assessed on the basis of success of defibrillation, return of spontaneous heart beat, weanability from extracorporeal cardiopulmonary resuscitation, and left ventricular systolic function after weaning. The addition of thrombolytic to extracorporeal cardiopulmonary resuscitation significantly improved cardiac resuscitability (3.7 ± 1.6 in t-ECPR vs 1.0 ± 1.5 in c-ECPR). Arterial lactate clearance was higher in t-ECPR than in c-ECPR (40% ± 15% vs 18% ± 21%). At the end of the experiment, the intracranial pressure was significantly higher in c-ECPR than in t-ECPR. Recovery of brain electrical activity, as assessed by quantitative analysis of electroencephalogram signal, and ischemic neuronal injury on histopathologic examination did not differ between groups. Animals in t-ECPR group did not have increased bleeding complications, including intracerebral hemorrhages. CONCLUSIONS: In a porcine model of prolonged cardiac arrest, t-ECPR improved cardiac resuscitability and reduced brain edema, without increasing bleeding complications. However, early electroencephalogram recovery and ischemic neuronal injury were not improved.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Oxigenación por Membrana Extracorpórea/métodos , Fibrinolíticos/administración & dosificación , Paro Cardíaco/terapia , Estreptoquinasa/administración & dosificación , Animales , Temperatura Corporal , Terapia Combinada , Electroencefalografía , Fibrinolíticos/uso terapéutico , Paro Cardíaco/tratamiento farmacológico , Hemodinámica , Presión Intracraneal , Estreptoquinasa/uso terapéutico , Porcinos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA