Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Science ; 357(6348): 287-290, 2017 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-28663438

RESUMEN

Quantum spin Hall materials hold the promise of revolutionary devices with dissipationless spin currents but have required cryogenic temperatures owing to small energy gaps. Here we show theoretically that a room-temperature regime with a large energy gap may be achievable within a paradigm that exploits the atomic spin-orbit coupling. The concept is based on a substrate-supported monolayer of a high-atomic number element and is experimentally realized as a bismuth honeycomb lattice on top of the insulating silicon carbide substrate SiC(0001). Using scanning tunneling spectroscopy, we detect a gap of ~0.8 electron volt and conductive edge states consistent with theory. Our combined theoretical and experimental results demonstrate a concept for a quantum spin Hall wide-gap scenario, where the chemical potential resides in the global system gap, ensuring robust edge conductance.

2.
Eur J Clin Chem Clin Biochem ; 31(3): 165-72, 1993 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8490063

RESUMEN

The following analytes were determined with the automated enzyme immunoassay unit, Enzymun-Test System ES 300, and by routine in-house tests, and the results were compared: thyrotropin, free thyroxine, cortisol, immunoglobulin E, digoxin, digitoxin, insulin and carcinoembryonic antigen. The methods used for comparison included two radioimmunoassays, one with enzyme labelling, two with fluorescence enhanced enzyme reactions and 3 luminescence immunoassays. In most cases, the precision of the ES 300 lay between 2 and 5% in all assays in the concentration ranges of clinical interest. The inter-assay variation was almost identical to the intra-assay precision, which reflects the constancy of reagent quality and machine performance. The correlation between in-house and Enzymun-Test was excellent, even though the slope of the regression line was sometimes far from unity, due to the calibration materials used. ES 300 can be used as a stand alone unit and connected to a host computer. As a "walk-away" machine, it is suitable for laboratories with medium length series. It is a multi-batch analyser capable of taking 12 analytes and a maximal series length of 136 tubes excluding standards and controls.


Asunto(s)
Análisis Químico de la Sangre/métodos , Técnicas para Inmunoenzimas , Antígeno Carcinoembrionario/sangre , Digitoxina/sangre , Digoxina/sangre , Estudios de Evaluación como Asunto , Humanos , Hidrocortisona/sangre , Inmunoensayo , Inmunoglobulina E/sangre , Insulina/sangre , Mediciones Luminiscentes , Radioinmunoensayo , Análisis de Regresión , Reproducibilidad de los Resultados , Tirotropina/sangre , Tiroxina/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA