Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BMC Musculoskelet Disord ; 20(1): 293, 2019 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-31215422

RESUMEN

BACKGROUND: The objective of this pilot study was to identify biological, clinical or structural biomarkers of an intra-articular hyaluronic acid injection efficacy (HYMOVIS®) for the design of a larger placebo-controlled clinical trial studying the disease-modifying activity of this treatment. METHODS: Forty six patients with symptomatic knee Osteoarthritis (OA) were enrolled in this open-label, prospective, multicenter, pilot study. Patients received two treatment cycles of intra-articular injections (3 mL) of HYMOVIS® (8 mg/mL of hyaluronic acid hexadecylamide) at 6 months interval. Each treatment cycle involved two intra-articular injections 1 week apart. All patients had Magnetic Resonance Imaging (MRI) of the target knee at baseline and 1 year, and blood samples to assess joint biomarkers. The primary outcome was the change in type II collagen-specific biomarkers (Coll2-1, Coll2-1NO2 and CTX-II) after HYMOVIS® treatment versus baseline. Secondary endpoints included levels changes in aggrecan chondroitin sulfate 846 epitope (CS-846), Cartilage Oligomeric Matrix Protein (COMP), procollagen type II N-terminal propeptide (PIIANP), Matrix Metalloprotease (MMP)-3, Myeloperoxidase (MPO) and Interleukin (IL)-6 serum biomarkers, the ratio Coll2-1/PIIANP, CTX-II/PIIANP, variation of MRI cartilage volume, and Knee injury and Osteoarthritis Outcome Score (KOOS) index. RESULTS: Coll2-1 serum levels significantly increased overtime while Coll2-1NO2 levels were only increased at D360. Serum PIIANP levels also progressively and significantly enhanced with time. In contrast, other serum biomarker levels including CTX-II, CS-846, COMP, MMP-3, MPO or IL-6 did not change significantly overtime. Interestingly, the ratios Coll2-1/PIIANP and CTX-II/PIIANP decreased, indicating a decrease of cartilage catabolism. Compared to baseline value, MRI cartilage volume and thickness increased in lateral femoral and lateral trochlea compartments and not in medial compartment. These results, in addition to an improvement of T2 mapping score suggest a positive structural effect of the product. Interestingly, WORMS effusion score, an indicator of synovitis, significantly decreased. Finally, global KOOS score and subscales significantly increased overtime while pain at rest, walking pain and patients or investigators global assessment of disease activity decreased. The safety profile was favorable with a low incidence of injection-site pain. CONCLUSION: HYMOVIS®, a well-tolerated intra-articular treatment, significantly enhanced type II collagen turnover as suggested by the increase in Coll2-1 and PIIANP levels and cartilage volume observed by MRI in lateral knee compartment. Importantly, this study provides critical information for the design of a larger phase III clinical trial investigating Disease Modifying effect of HYMOVIS®. TRIAL REGISTRATION: http://www.isrctn.com/ISRCTN12227846 11/02/2015.


Asunto(s)
Cartílago Articular/efectos de los fármacos , Colágeno Tipo II/metabolismo , Ácido Hialurónico/administración & dosificación , Osteoartritis de la Rodilla/tratamiento farmacológico , Fragmentos de Péptidos/metabolismo , Viscosuplementos/administración & dosificación , Anciano , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/metabolismo , Colágeno Tipo II/sangre , Femenino , Humanos , Ácido Hialurónico/análogos & derivados , Hidrogeles/administración & dosificación , Inyecciones Intraarticulares , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/efectos de los fármacos , Articulación de la Rodilla/metabolismo , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/sangre , Osteoartritis de la Rodilla/diagnóstico por imagen , Fragmentos de Péptidos/sangre , Proyectos Piloto , Procolágeno/sangre , Procolágeno/metabolismo , Estudios Prospectivos , Resultado del Tratamiento
2.
Ann Rheum Dis ; 72(5): 665-71, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-22679298

RESUMEN

OBJECTIVES: To evaluate synovitis (clinical vs ultrasound (US)) to predict structural progression in rheumatoid arthritis (RA). METHODS: Patients with RA. STUDY DESIGN: Prospective, 2-year follow-up. DATA COLLECTED: Synovitis (32 joints (2 wrists, 10 metacarpophalangeal, 10 proximal interphalangeal, 10 metatarsophalangeal)) at baseline and after 4 months of therapy by clinical, US grey scale (GS-US) and power doppler (PD-US); x-rays at baseline and at year 2. ANALYSIS: Measures of association (OR) were tested between structural deterioration and the presence of baseline synovitis, or its persistence, after 4 months of therapy using generalised estimating equation analysis. RESULTS: Structural deterioration was observed in 9% of the 1888 evaluated joints in 59 patients. Baseline synovitis increased the risk of structural progression: OR=2.01 (1.36-2.98) p<0.001 versus 1.61 (1.06-2.45) p=0.026 versus 1.75 (1.18-2.58) p=0.005 for the clinical versus US-GS versus US-PD evaluation, respectively. In the joints with normal baseline examination (clinical or US), an increased probability for structural progression in the presence of synovitis for the other modality was also observed (OR=2.16 (1.16-4.02) p=0.015 and 3.50 (1.77-6.95) p<0.001 for US-GS and US-PD and 2.79 (1.35-5.76) p=0.002) for clinical examination. Persistent (vs disappearance) synovitis after 4 months of therapy was also predictive of subsequent structural progression. CONCLUSIONS: This study confirms the validity of synovitis for predicting subsequent structural deterioration irrespective of the modality of examination of joints, but also suggests that both clinical and ultrasonographic examinations may be relevant to optimally evaluate the risk of subsequent structural deterioration.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/patología , Examen Físico/normas , Sinovitis/diagnóstico por imagen , Sinovitis/patología , Ultrasonografía Doppler/normas , Adulto , Anciano , Artritis Reumatoide/epidemiología , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Articulaciones/diagnóstico por imagen , Articulaciones/patología , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Riesgo , Sinovitis/epidemiología
3.
Ann Rheum Dis ; 69(5): 828-33, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-19740905

RESUMEN

OBJECTIVES: To evaluate different global ultrasonographic (US) synovitis scoring systems as potential outcome measures of rheumatoid arthritis (RA) according to the Outcome Measures in Rheumatoid Arthritis Clinical Trials (OMERACT) filter. METHODS: To study selected global scoring systems, for the clinical, B mode and power Doppler techniques, the following joints were evaluated: 28 joints (28-joint Disease Activity Score (DAS28)), 20 joints (metacarpophalangeals (MCPs) + metatarsophalangeals (MTPs)) and 38 joints (28 joints + MTPs) using either a binary (yes/no) or a 0-3 grade. The study was a prospective, 4-month duration follow-up of 76 patients with RA requiring anti-tumour necrosis factor (TNF) therapy (complete follow-up data: 66 patients). Intraobserver reliability was evaluated using the intraclass correlation coefficient (ICC), construct validity was evaluated using the Cronbach alpha test and external validity was evaluated using level of correlation between scoring system and C reactive protein (CRP). Sensitivity to change was evaluated using the standardised response mean. Discriminating capacity was evaluated using the standardised mean differences in patients considered by the doctor as significantly improved or not at the end of the study. RESULTS: Different clinimetric properties of various US scoring systems were at least as good as the clinical scores with, for example, intraobserver reliability ranging from 0.61 to 0.97 versus from 0.53 to 0.82, construct validity ranging from 0.76 to 0.89 versus from 0.76 to 0.88, correlation with CRP ranging from 0.28 to 0.34 versus from 0.28 to 0.35 and sensitivity to change ranging from 0.60 to 1.21 versus from 0.96 to 1.36 for US versus clinical scoring systems, respectively. CONCLUSION: This study suggests that US evaluation of synovitis is an outcome measure at least as relevant as physical examination. Further studies are required in order to achieve optimal US scoring systems for monitoring patients with RA in clinical trials and in clinical practice.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Sinovitis/diagnóstico por imagen , Adulto , Anciano , Antirreumáticos/uso terapéutico , Artritis Reumatoide/tratamiento farmacológico , Artritis Reumatoide/patología , Métodos Epidemiológicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Examen Físico/métodos , Sinovitis/tratamiento farmacológico , Sinovitis/patología , Resultado del Tratamiento , Factor de Necrosis Tumoral alfa/antagonistas & inhibidores , Ultrasonografía Doppler/métodos
4.
J Rheumatol ; 40(3): 244-52, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23322464

RESUMEN

OBJECTIVE: Clinical joint examination (CJE) is less time-consuming than ultrasound (US) in rheumatoid arthritis (RA). Low concordance between CJE and US would indicate that the 2 tests provide different types of information. Knowledge of factors associated with CJE/US concordance would help to select patients and joints for US. Our objective was to identify factors associated with CJE/US concordance. METHODS: Seventy-six patients with RA requiring tumor necrosis factor-α (TNF-α) antagonist therapy were included in a prospective, multicenter cohort. In each patient, 38 joints were evaluated. Synovitis was scored using CJE, B-mode US (B-US), and power Doppler US (PDUS). Joints whose kappa coefficient (κ) for agreement CJE/US was < 0.1 were considered discordant. Multivariate analysis was performed to identify factors independently associated with CJE/US concordance, defined as factors yielding p < 0.05 and OR > 2. RESULTS: Concordance before TNF-α antagonist therapy varied across joints for CJE/US (κ = -0.08 to 0.51) and B-US/PDUS (κ = 0.30 to 0.67). CJE/US concordance was low at the metatarsophalangeal joints and shoulders (κ < 0.1). Before TNF-α antagonist therapy, a low 28-joint Disease Activity Score (DAS28) was associated with good CJE/B-US concordance, and no factors were associated with CJE/PDUS concordance. After TNF-α antagonist therapy, only the joint site was associated with CJE/B-US concordance; joint site and short disease duration were associated with CJE/PDUS concordance. CONCLUSION: Concordance between CJE and US is poor overall. US adds information to CJE, most notably at the metatarsophalangeal joints and shoulders. Usefulness is decreased for B-US when DAS28 is low and for PDUS when disease duration is short.


Asunto(s)
Artritis Reumatoide/diagnóstico , Articulaciones/diagnóstico por imagen , Articulaciones/patología , Examen Físico , Sinovitis/diagnóstico , Adulto , Anciano , Antirreumáticos/uso terapéutico , Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/tratamiento farmacológico , Artritis Reumatoide/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sinovitis/diagnóstico por imagen , Sinovitis/tratamiento farmacológico , Sinovitis/patología , Factor de Necrosis Tumoral alfa/antagonistas & inhibidores , Ultrasonografía
5.
J Rheumatol ; 37(5): 932-7, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20360184

RESUMEN

OBJECTIVES: To evaluate the reproducibility of clinical synovitis assessments in rheumatoid arthritis and the effect of variability on the Disease Activity Score-28 (DAS28). METHODS: Seven healthcare professionals from different cities examined the same patients with active non-early rheumatoid arthritis (RA; duration > 4 yrs), for whom a treatment change was being considered. There was no training session and the examination was to be performed as quickly as possible. The healthcare professionals assessed the 28 joints of the DAS28 in 7 patients (196 joints), then reexamined the same 28 joints in 4 of these 7 patients (112 joints), who had been rendered unrecognizable. Then 7 sonographers examined each of the 7 patients twice, using B-mode and power Doppler ultrasound (PD). The reference standards were presence of synovitis according to at least 50% of clinical examiners and 50% of sonographers. Agreement was assessed by Cohen's kappa statistic. RESULTS: Intraobserver reliability ranged from 0.31 (least experienced research technician) to 0.77 (most experienced physician). Interobserver reliability ranged from 0.18 to 0.62. The largest difference between the lowest and the highest swollen joint counts in the same patient was 15, and the greatest variation in the DAS28 score was 0.92. Agreement between clinical and sonographic reference standards was 0.46, 0.37, and 0.36 for B-mode, PD, and both, respectively. CONCLUSION: Clinical inter- and intraobserver reliability is highly dependent on the examiner. Consequences on the DAS28 score can be substantial. Agreement with sonography is poor when both B-mode and PD are used but seems better, although low, when B-mode is used alone.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Articulaciones/diagnóstico por imagen , Sinovitis/diagnóstico por imagen , Anciano , Artritis Reumatoide/complicaciones , Artritis Reumatoide/fisiopatología , Femenino , Humanos , Articulaciones/fisiopatología , Masculino , Persona de Mediana Edad , Estándares de Referencia , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Sinovitis/complicaciones , Sinovitis/fisiopatología , Ultrasonografía
6.
J Rheumatol ; 37(5): 938-45, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20231197

RESUMEN

OBJECTIVE: To evaluate the intraobserver and interobserver reproducibility of B-mode and power Doppler (PD) sonography in patients with active long-standing rheumatoid arthritis (RA) comparatively with clinical data. METHODS: In each of 7 patients being considered for a change in their RA treatment regimen, 7 healthcare professionals examined the 28 joints used in the Disease Activity Score 28-joint count (DAS28). Then 7 sonographers examined each of the 7 patients twice, using previously published B-mode and PD grading systems. The clinical reference standard was presence of synovitis according to at least 4/7 examiners. The sonographic reference standard was at least grade 1 (ALG1) or 2 (ALG2) synovitis according to at least 4/7 sonographers. Interobserver reproducibility of sonography was assessed versus the sonographer having the best intraobserver reproducibility. Agreement was measured by Cohen's kappa statistic. RESULTS: Intraobserver and interobserver reproducibility of B-mode and PD used separately was fair to good. Agreement between clinicians and sonographers at all sites using B-mode, PD, and both was 0.46, 0.37, and 0.36, respectively, for grade 1 synovitis; and 0.58, 0.19, and 0.19 for grade 2 synovitis. The number of joints with synovitis was smaller by physical examination (36.7%) than by B-mode with ALG1 (58.6%; p < 0.001). The number of joints with synovitis was higher by physical examination than by PD with both ALG1 (17.8%; p < 0.0001) and ALG2 (6.6%; p < 0.0001). CONCLUSION: PD findings explain most of the difference between clinical and sonographic joint assessments for synovitis in patients with long-standing RA.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Articulaciones/diagnóstico por imagen , Sinovitis/diagnóstico por imagen , Anciano , Artritis Reumatoide/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Sinovitis/complicaciones , Ultrasonografía Doppler
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA