Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Vet Res ; 14(1): 72, 2018 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-29510691

RESUMEN

BACKGROUND: Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during anaesthesia would be beneficial for both the anaesthesia management and its outcome. New techniques for the monitoring of CO are aimed at finding methods which are non invasive, accurate and with good trending ability, which can be used in a clinical setting. The aim of this study was to compare the Pressure Recording Analytical Method (PRAM) with the pulmonary artery thermodilution (TD) for the measurement of cardiac output in 6 anaesthetized critically ill dogs. RESULTS: Fifty-four pairs of CO measurements were obtained with a median (range) of 3.33 L/min (0.81-7.21) for PRAM-CO and 3.48 L/min (1.41-6.56) for TD-CO. The Bland-Altman analysis showed a mean bias of 0.17 L/min with limits of agreement (LoA) of - 0.46 to 0.81 L/min. The percentage error resulted 18.2%. The 4-quadrant plot analysis showed an acceptable concordance (93%) between the 2 methods. The polar plot showed a good trending ability with the mean angular bias of 3.9° and radial LoA ± 12.1°. CONCLUSIONS: The PRAM resulted in good precision, acceptable concordance and good trending ability for the measure of CO in the anaesthetized dog, representing a promising alternative to thermodilution for the measurement of CO. Among all the pulse contour methods available on the market it is the only one that does not require any calibration or adjustment of the measurement. Further studies are required to verify the ability of this method to accurately measure cardiac output even during unstable hemodynamic conditions.


Asunto(s)
Gasto Cardíaco/fisiología , Perros/fisiología , Monitoreo Fisiológico/veterinaria , Anestesia General/métodos , Anestesia General/veterinaria , Animales , Presión Sanguínea/fisiología , Perros/cirugía , Femenino , Monitoreo Fisiológico/métodos , Pulso Arterial/veterinaria , Sepsis/fisiopatología , Sepsis/cirugía , Sepsis/veterinaria , Termodilución/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA