Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Heart Fail Rev ; 29(2): 559-569, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38329583

RESUMEN

The use of left ventricular assist devices (LVAD) has significantly increased in the last years, trying to offer a therapeutic alternative to heart transplantation, in light also to the significant heart donor shortage compared to the growing advanced heart failure population. Despite technological improvements in the devices, LVAD-related mortality is still fairly high, with right heart failure being one of the predominant predictors. Therefore, many efforts have been made toward a thorough right ventricular (RV) evaluation prior to LVAD implant, considering clinical, laboratory, echocardiographic, and invasive hemodynamic parameters. However, there is high heterogeneity regarding both which predictor is the strongest as well as the relative cut-off values, and a consensus has not been reached yet, increasing the risk of facing patients in which the distinction between good or poor RV function cannot be surely reached. In parallel, due to technological development and availability of mechanical circulatory support of the RV, LVADs are being considered even in patients with suboptimal RV function. The aim of our review is to analyze the current evidence regarding the role of RV function prior to LVAD and its evaluation, pointing out the extreme variability in parameters that are currently assessed and future prospective regarding new diagnostic tools. Finally, we attempt to gather the available information on the therapeutic strategies to use in the peri-operative phase, in order to reduce the incidence of RV failure, especially in patients in which the preoperative evaluation highlighted some conflicting results with regard to ventricular function.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Disfunción Ventricular Derecha , Humanos , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/etiología , Trasplante de Corazón/efectos adversos , Ecocardiografía , Estudios Retrospectivos
2.
Artif Organs ; 46(12): 2486-2492, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35866429

RESUMEN

BACKGROUND: We investigated the synergistic effect of the new cone-bearing design of Jarvik 2000 (Jarvik Heart Inc., NY) together with a minimally-invasive approach to outcomes of LVAD patients. METHODS: We retrospectively reviewed all patients from 5 institutions involved in the Jarvik 2000 Italian Registry, from October 2008 to October 2016. Patients were divided into three groups according to pump design and implantation technique: pin-bearing design and conventional approach (Group 1); cone-bearing and conventional approach (Group 2); cone-bearing and minimally-invasive implantation (Group 3). RESULTS: A total of 150 adult patients with end-stage heart failure were enrolled: 26 subjects in Group 1, 74 in Group 2, and 50 in Group 3. Nineteen patients (73%) in Group 1, 51 (69%) in Group 2, and 36 (72%) in Group 3 were discharged. During follow-up, 22 patients underwent transplantation, while in 3 patients the LVAD was explanted. The overall 1-year survival was 58 ± 10%, 64 ± 6%, and 74% ± 7% in Groups 1, 2, and 3, respectively (p = 0.034). The competing-risks-adjusted cumulative incidence rate for adverse events was 42.1 [27-62.7] per 100 patient-years in Group 1, 35.4 [25.3-48.2] in Group 2, and 22.1 [12.4-36.4] in Group 3 (p = 0.046 for Group 1 vs. 3). CONCLUSIONS: The association of the modern cone-bearing configuration of Jarvik 2000 and minimally invasive surgery improved survival and minimized the risk for cardiovascular events, as a result of combining technology and technique.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Adulto , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Insuficiencia Cardíaca/cirugía , Sistema de Registros , Tecnología , Resultado del Tratamiento
3.
Transpl Infect Dis ; 23(1): e13428, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32743882

RESUMEN

BACKGROUND: The risk of COVID-19 is expected to be higher among solid organ transplant. The aim of the present study was to evaluate the incidence of COVID-19 and the impact of the SARS-CoV-2 outbreak on the personal hygiene and expectations in heart and lung transplant recipients. METHODS: A telephone survey of heart (n = 69) and lung (n = 41) transplant patients and a group of controls (n = 41) was conducted concerning personal hygiene before and after the outbreak; the impact on subjective expectations regarding graft outcome; symptoms possibly associated with SARS-CoV-2 infection; and diagnosis of COVID-19. RESULTS: Seventy nine percent of the patients declared they increased the use of face masks and handwash. Behavior at home regarding self-isolation did not change. About half the patients said they were afraid of the virus. A higher percentage of Lung transplant (LTX) were convinced that SARS-CoV-2 could have a negative impact on the outcome of their graft. 28% declared that they were afraid to come to the hospital for routine examinations and asked to postpone. Nine LTX and five Heart transplant (HTX) patients experienced symptoms that could have been associated with SARS-CoV-2 infection, but none of them underwent a nasopharyngeal swab. Only one LTX was diagnosed with the infection. CONCLUSIONS: In our study, we observed a low incidence of COVID-19 in heart and lung transplant patients (0.9%), similar to that of the general population of our Region. Isolation measures were already observed before the pandemic and were further strengthened in most cases. Particular attention should also be paid to new psychological and physical complications indirectly linked to the COVID-19 pandemic.


Asunto(s)
COVID-19/complicaciones , Desinfección de las Manos , Trasplante de Corazón-Pulmón , Máscaras , Prioridad del Paciente , SARS-CoV-2 , Adulto , Estudios de Casos y Controles , Control de Enfermedades Transmisibles , Recolección de Datos , Femenino , Guantes Quirúrgicos , Humanos , Entrevistas como Asunto , Masculino , Persona de Mediana Edad
4.
Artif Organs ; 45(3): 236-243, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32860268

RESUMEN

Continuous flow left ventricular assist devices (LVADs) have become a valuable therapy for end-stage heart failure. In vitro research highlighted a role of outflow cannula position on the pattern of blood flow in the aorta. However, the clinical effects of the alterations of flow remain unclear. We investigate short- and long-term outcomes of patients implanted with Jarvik 2000 LVAD, according to the ascending (Group 1) versus descending (Group 2) outflow graft connection to the aorta in a multicenter study. From May 2008 to October 2014, 140 consecutive end-stage heart failure patients underwent Jarvik 2000 LVAD implantation in 17 Italian centers. According with a preliminary multivariate analysis, we selected the 90 patients implanted in the four high-volume centers to avoid bias (Group 1 n = 39, Group 2 n = 51). Among the groups, no differences were recorded in the hospital mortality and the main complications occurring after LVAD implantation were similar. In multivariable analysis, the ascending aorta outflow cannula position and higher creatinine at discharge were significant predictors for long-term survival. Postimplant hemolysis was more pronounced in descending aorta outflow graft anastomosis. Outflow graft anastomosis to the ascending aorta is associated with better long-term survival, independent of age and perfusion techniques, reflecting the previous in vitro results.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis/efectos adversos , Anciano , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Aorta/fisiopatología , Aorta/cirugía , Creatinina/sangre , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Hemodinámica/fisiología , Hemólisis/fisiología , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Resultado del Tratamiento
5.
Cardiovasc Ultrasound ; 12: 20, 2014 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-24935114

RESUMEN

BACKGROUND: Heart transplantation is limited by severe donor organ shortage. Regardless of the changes made in the acceptance of marginal donors, any such mechanism cannot be considered successful unless recipient graft survival rates remain acceptable. A stress echo-driven selection of donors has proven successful in older donors with normal left ventricular resting function and in standard donors with reversible resting left ventricular dysfunction acutely improving during stress, or slowly improving (over hours) during intensive hormonal treatment. Aim of this study is to assess the medium-term outcome of recipients of marginal donor hearts selected with new echocardiographic techniques over standard criteria. METHODS AND RESULTS: We enrolled 43 recipients of marginal donor hearts: age > 55 years, or < 55 years but with concomitant risk factors, n = 32; acutely improving during stress, n = 3; or slowly improving during hormonal treatment, n = 8. At follow-up (median, 30 months; interquartile range, 21-52 months), 37 of the recipients were still alive. One-year survival was 93%. CONCLUSION: The strict use of new stress-echocardiographic techniques over standard criteria of marginal donor management, together with comprehensive monitoring of the donor, has the potential to substantially increase the number of donor hearts without adverse effects on recipient medium-term outcome.


Asunto(s)
Ecocardiografía de Estrés/métodos , Trasplante de Corazón/mortalidad , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad , Anciano , Angiografía Coronaria , Femenino , Estudios de Seguimiento , Supervivencia de Injerto , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Donantes de Tejidos , Obtención de Tejidos y Órganos , Resultado del Tratamiento
6.
Heart Fail Clin ; 10(1 Suppl): S39-45, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24262351

RESUMEN

The authors herein review the rationale and indications for the use of ventricular assistance devices as a bridge to heart transplantation and discuss the current evidence on the subject. The potential effects of device implantation on posttransplant outcomes and the therapeutic strategies in acute and elective cases are revised and illustrated.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Corazón Auxiliar , Insuficiencia Cardíaca/mortalidad , Humanos , Donantes de Tejidos/provisión & distribución , Resultado del Tratamiento
7.
Diagnostics (Basel) ; 14(11)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38893722

RESUMEN

BACKGROUND: An increasing proportion of heart failure (HF) patients progress to the advanced stage (AdHF) with high event rates and limited treatment options. Echocardiography, particularly Speckle Tracking-derived myocardial work (MW), is useful for HF diagnosis and prognosis. We aimed to assess MW's feasibility in the prognostic stratification of AdHF. METHODS: We retrospectively screened patients with AdHF who accessed our hospital in 2018-2022. We excluded subjects with inadequate acoustic windows; unavailable brachial artery cuff pressure at the time of the echocardiography; atrial fibrillation; and mitral or aortic regurgitation. We measured standard parameters and left ventricular (LV) strain (LS) and MW. The population was followed up to determine the composite outcomes of all-cause mortality, left ventricular assist device implantation and heart transplantation (primary endpoint), as well as unplanned HF hospitalization (secondary endpoint). RESULTS: We enrolled 138 patients, prevalently males (79.7%), with a median age of 58 years (IQR 50-62). AdHF etiology was predominantly non-ischemic (65.9%). Thirty-five patients developed a composite event during a median follow-up of 636 days (IQR 323-868). Diastolic function, pulmonary pressures, and LV GLS and LV MW indices were not associated with major events. Contrarily, for the secondary endpoint, the hazard ratio for each increase in global work index (GWI) by 50 mmHg% was 0.90 (p = 0.025) and for each increase in global constructive work (GCW) by 50 mmHg% was 0.90 (p = 0.022). Kaplan-Meier demonstrated better endpoint-free survival, with an LV GWI ≥ 369 mmHg%. CONCLUSIONS: GWI and GCW, with good feasibility, can help in the better characterization of patients with AdHF at higher risk of HF hospitalization and adverse events, identifying the need for closer follow-up or additional HF therapy.

8.
Eur Heart J Cardiovasc Imaging ; 25(4): 446-453, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38109280

RESUMEN

AIMS: Advanced heart failure (AdHF) is characterized by variable degrees of left ventricular (LV) dysfunction, myocardial fibrosis, and raised filling pressures which lead to left atrial (LA) dilatation and cavity dysfunction. This study investigated the relationship between LA peak atrial longitudinal strain (PALS), assessed by speckle-tracking echocardiography (STE), and invasive measures of LV filling pressures and fibrosis in a group of AdHF patients undergoing heart transplantation (HTX). METHODS AND RESULTS: We consecutively enrolled patients with AdHF who underwent HTX at our Department. Demographic and basic echocardiographic data were registered, then invasive intracardiac pressures were obtained from right heart catheterization, and STE was also performed. After HTX, biopsy specimens from explanted hearts were collected to quantify the degree of LV myocardial fibrosis. Sixty-four patients were included in the study (mean age 62.5 ± 11 years, 42% female). The mean LV ejection fraction (LVEF) was 26.7 ± 6.1%, global PALS was 9.65 ± 4.5%, and mean pulmonary capillary wedge pressure (PCWP) was 18.8 ± 4.8 mmHg. Seventy-three % of patients proved to have severe LV fibrosis. Global PALS was inversely correlated with PCWP (R = -0.83; P < 0.0001) and with LV fibrosis severity (R = -0.78; P < 0.0001) but did not correlate with LVEF (R = 0.15; P = 0.2). Among echocardiographic indices of LV filling pressures, global PALS proved the strongest [area under the curve 0.955 (95% confidence interval 0.87-0.99)] predictor of raised (>18 mmHg) PCWP. CONCLUSION: In patients with AdHF, reduced global PALS strongly correlated with the invasively assessed LV filling pressure and degree of LV fibrosis. Such relationship could be used as non-invasive indicator for optimum patient stratification for therapeutic strategies.


Asunto(s)
Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Función del Atrio Izquierdo , Función Ventricular Izquierda , Ventrículos Cardíacos , Volumen Sistólico , Fibrosis
9.
Pharmacology ; 92(5-6): 281-5, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24296902

RESUMEN

OBJECTIVES: The dual endothelin receptor antagonist bosentan improves pulmonary vascular resistance (PVR) in patients with primary pulmonary hypertension (PH). The effects of bosentan on secondary PH due to systolic heart failure (HF) are not well defined. This study evaluates the effect and tolerability of bosentan in patients with PH secondary to HF. METHODS: Seventeen adult HF patients with PH and New York Heart Association class III-IV symptoms were treated with bosentan, 62.5 mg twice daily, for 1 month, which was gradually increased to 125 mg twice daily thereafter. Right heart catheterization (RHC), a clinical evaluation and echocardiographic measurements were performed at baseline and at 4 ± 3 (mean ± SD) months of follow-up. Response to bosentan was defined as an improvement in clinical, echocardiographic and RHC parameters. RESULTS: Six patients did not complete the study (therapy was discontinued due to hypotension, elevated liver enzymes or acute decompensation of HF), 11 patients completed the follow-up; 9 patients responded to therapy. Systemic arterial pressures, pulmonary pressures, PVR and the transpulmonary gradient significantly decreased compared with baseline levels in 9 responders (p = 0.05, 0.05, 0.01 and 0.004, respectively), and 4 became eligible for heart transplantation and 3 for left ventricular assist device implantation. CONCLUSIONS: Bosentan decreased pulmonary pressures and PVR in the majority of patients with PH secondary to systolic HF, thereby allowing them to be considered candidates for heart transplantation.


Asunto(s)
Antihipertensivos/uso terapéutico , Insuficiencia Cardíaca Sistólica/complicaciones , Hipertensión Pulmonar/tratamiento farmacológico , Sulfonamidas/uso terapéutico , Bosentán , Cateterismo Cardíaco/métodos , Ecocardiografía , Antagonistas de los Receptores de Endotelina , Femenino , Estudios de Seguimiento , Humanos , Hipertensión Pulmonar/etiología , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Resistencia Vascular/efectos de los fármacos
10.
Eur Heart J Cardiovasc Imaging ; 25(1): 105-115, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-37542478

RESUMEN

AIMS: Right heart failure (RHF) after left ventricular assist device (LVAD) implant is burdened by high morbidity and mortality rates and should be prevented by appropriate patient selection. Adequate right ventricular function is of paramount importance but its assessment is complex and cannot disregard afterload. Myocardial work (MW) is a non-invasive Speckle Tracking Echocardiography-derived method to estimate pressure-volume loops. The aim of this study was to evaluate the performance of right ventricular myocardial work to predict RHF and long-term mortality after LVAD implant. METHODS AND RESULTS: Consecutive patients from May 2017 to February 2022 undergoing LVAD implant were retrospectively reviewed. Patients without a useful echocardiographic exam prior to LVAD implant were excluded. MW analysis was performed. The primary endpoints were early RHF (<30 days from LVAD implant) and death at latest available follow-up. We included 23 patients (mean age 64 ± 8 years, 91% men). Median follow-up was 339 days (IQR: 30-1143). Early RHF occurred in six patients (26%). A lower right ventricular global work efficiency [RVGWE, OR 0.86, 95% confidence intervals (CI) 0.76-0.97, P = 0.014] was associated with the occurrence of early RHF. Among MW indices, the performance for early RHF prediction was greatest for RVGWE [area under the curve (AUC) 0.92] and a cut-off of 77% had a 100% sensitivity and 82% specificity. At long-term follow-up, death occurred in 4 of 14 patients (28.6%) in the RVGWE > 77% group and in 6 of 9 patients (66.7%) in the RVGWE < 77% group (HR 0.25, 95% CI 0.07-0.90, P = 0.033). CONCLUSION: RVGWE was a predictor of early RHF after LVAD implant and brought prognostic value in terms of long-term mortality.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Disfunción Ventricular Derecha , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Estudios Retrospectivos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/epidemiología , Pronóstico , Ecocardiografía , Disfunción Ventricular Derecha/diagnóstico por imagen
11.
ESC Heart Fail ; 10(5): 2853-2864, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37415291

RESUMEN

AIMS: The presence of anti-human leucocyte antigen (HLA) antibodies has been implicated in a higher incidence of complications as well as mortality rate in heart transplantation. The aim of the study was to identify through non-invasive parameters early signs of myocardial dysfunction in the presence of anti-HLA antibodies but without evidence of antibody-mediated rejection (AMR) and its possible prognostic impact. METHODS AND RESULTS: A total of 113 heart-transplanted patients without acute cellular rejection (ACR) and AMR or cardiac allograft vasculopathy (CAV) were prospectively enrolled and divided into two groups ['HLA+' (50 patients) and 'HLA-' (63 patients)], based on the presence of anti-HLA antibodies. Each patient was followed for 2 years after the enrolment, recording episodes of AMR, ACR, CAV, and mortality. Clinical characteristics were similar between the two groups. Among laboratory data, N-terminal pro-B-type natriuretic peptide and high-sensitivity cardiac troponin values were significantly higher in the presence of anti-HLA antibodies (P < 0.001 and P = 0.003, respectively). The echocardiographic parameters that showed a statistically significant difference between the two groups were deceleration time of E wave (DecT E, P < 0.001), left ventricular global longitudinal strain (P < 0.001), tricuspid annular plane systolic excursion (P = 0.011), tricuspid S' wave (P = 0.002), and free wall right ventricular longitudinal strain (fwRVLS, P = 0.027), whereas left atrial strain did not differ significantly (P = 0.408). Univariate analysis showed that anti-HLA antibodies were associated with the development of CAV at both 1 and 2 year follow-up [odds ratio (OR) 11.90, 95% confidence interval (CI) 1.43-90.79, P = 0.022 and OR 3.37, 95% CI 1.78-9.67, P = 0.024, respectively]. Bivariate analysis demonstrated that both fwRVLS and DecT E were predictors of CAV development independently from HLA status. CONCLUSIONS: The presence of circulating anti-HLA antibodies is correlated with a mild cardiac dysfunction, even in the absence of AMR, and CAV development. Interestingly, reduced values of DecT E and fwRVLS were predictors of future development of CAV, independently from anti-HLA antibody.


Asunto(s)
Trasplante de Corazón , Humanos , Trasplante de Corazón/efectos adversos , Trasplante de Corazón/métodos , Anticuerpos , Pronóstico , Rechazo de Injerto/diagnóstico , Ecocardiografía
12.
Diagnostics (Basel) ; 13(16)2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37627879

RESUMEN

BACKGROUND: The hemodynamic definition of PH has recently been revised with unchanged threshold of peak tricuspid regurgitation velocity (TRV). The aim of this study was to evaluate the predictive accuracy of peak TRV for PH based on the new (>20 mmHg) and the old (>25 mmHg) cut-off value for mean pulmonary artery pressure (mPAP) and to compare it with the mean right ventricular-right atrial (RV-RA) pressure gradient. METHODS: Patients with advanced heart failure were screened from 2016 to 2021. The exclusion criteria were absent right heart catheterization (RHC) results, chronic obstructive pulmonary disease, any septal defect, inadequate acoustic window or undetectable TR. The mean RV-RA gradient was calculated from the velocity-time integral of TR. RESULTS: The study included 41 patients; 34 (82.9%) had mPAP > 20 mmHg and 24 (58.5%) had mPAP > 25 mmHg. The AUC for the prediction of PH with mPAP > 20 mmHg was 0.855 for peak TRV and mean RV-RA gradient was 0.811. AUC for the prediction of PH defined as mPAP > 25 mmHg for peak TRV was 0.860 and for mean RV-RA gradient was 0.830. A cutoff value of 2.4 m/s for peak TRV had 65% sensitivity and 100% positive predictive value for predicting PH according to the new definition. CONCLUSIONS: Peak TRV performed better than mean RV-RA pressure gradient in predicting PH irrespective of hemodynamic definitions. Peak TRV performed similarly with the two definitions of PH, but a lower cutoff value had higher sensitivity and equal positive predictive value for PH.

13.
J Clin Med ; 12(10)2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37240611

RESUMEN

Background: The gold-standard treatment for end-stage heart failure is heart transplantation, but the lack of organ donors remains an important limitation in this field. An accurate selection of marginal hearts is fundamental to increase organ availability. Purpose: In our study we analyzed if recipients receiving marginal donor (MD) hearts, selected by dipyridamole stress echocardiography according to the ADOHERS national protocol, had different outcomes compared to recipients with acceptable donor (AD) hearts. Methods: Data were collected and retrospectively analyzed from patients who received an orthotopic heart transplant at our institution between 2006 and 2014. Dipyridamole stress echo was performed on identified marginal donors and selected hearts were eventually transplanted. Clinical, laboratory and instrumental features of the recipients were evaluated and patients with homogenous baseline characteristics were selected. Results: Eleven recipients transplanted with a selected marginal heart and eleven recipients transplanted with an acceptable heart were included. Mean donor age was 41 ± 23. The median follow-up was 113 months (IQR 86-146 months). Age, cardiovascular risk and morpho-functional characteristics of the left ventricle were comparable between the two populations (p > 0.05). Left atrial size was significantly higher in patients with marginal hearts (acceptable atrial volume: 23 ± 5 mL; marginal atrial volume: 38 ± 5 mL; p = 0.003). Acceptable donor recipients showed a higher impact of Cardiac Allograph Vasculopathy (p = 0.019). No rejection differences were found between the two groups. Four patients deceased, three were standard donor recipients and one was from the marginal donor group. Conclusions: Our study shows how cardiac transplant (Htx) from selected marginal donor hearts through a non-invasive bedside technique can alleviate the shortage of organs without a difference in survival compared to acceptable donor hearts.

14.
ESC Heart Fail ; 10(4): 2607-2620, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37345220

RESUMEN

AIMS: Mechanical circulatory support (MCS) systems are increasingly employed in cardiogenic shock and advanced heart failure. A thorough understanding of the complex interactions occurring among heart, vasculature, and device is essential to optimize patient's management. The aim of this study is to explore non-invasive haemodynamic profiling of patients undergoing MCS based on pressure-strain (PS) analysis. METHODS: Clinical and echocardiographic data from consecutive patients undergoing different MCS systems positioning/implantation admitted to the third level cardiological intensive care unit of Siena Hospital from August 2021 to November 2021 were retrospectively reviewed. Patients without a useful echocardiographic exam or without arterial blood pressure recording at the time of echocardiography were excluded. Myocardial work analysis was performed in the included patients. RESULTS: We reviewed 18 patients, of which nine were excluded. Included patients were three patients with intra-aortic balloon pump (IABP), two patients with durable left ventricular assist device (dLVAD), two patients with Impella®, one patient with extracorporeal membrane oxygenation (ECMO), and one patient with ECMO and IABP. Myocardial work analysis was feasible in each included patient. The use of IABP shifted the PS curve rightward and downward. Global work index (GWI) and global wasted work (GWW) decreased after IABP positioning, whereas global work efficiency (GWE) increased. The use of continuous-flow pumps, whether temporaneous (Impella®) or long term (dLVAD), induced a change in the PS loop morphology, with a shift towards a triangular shape. ECMO positioning alone resulted in a narrowing of the PS loop, with a decrease in GWI and GWE and an increase in GWW and mean arterial pressure. The combined used of IABP with ECMO widened the PS loop and improved GWI and GWE. CONCLUSIONS: PS loops analysis in patients undergoing MCS seems to be feasible and may unveil MCS-induced haemodynamic variations. Myocardial work could be used to monitor ventricular-arterial-device coupling and guide tailored MCS management.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Estudios Retrospectivos , Choque Cardiogénico/terapia , Insuficiencia Cardíaca/terapia , Hemodinámica
15.
J Card Fail ; 18(3): 208-15, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22385941

RESUMEN

BACKGROUND: Right ventricular (RV) systolic function has a critical role in determining the clinical outcome and success of using left ventricular assist devices (LVADs) in patients with refractory heart failure. Tissue Doppler and M-mode measurements of tricuspid systolic motion (tricuspid S' and tricuspid annular plane systolic excursion [TAPSE]) are the most currently used methods for the quantification of RV longitudinal function; RV deformation analysis by speckle-tracking echocardiography (STE) has recently allowed the analysis of global RV longitudinal function. Using cardiac catheterization as the reference standard, this study aimed at exploring the correlation between RV longitudinal function by STE and RV stroke work index (RVSWI) in patients referred for cardiac transplantation. METHODS AND RESULTS: Right-side heart catheterization and transthoracic echo Doppler were simultaneously performed in 41 patients referred for cardiac transplantation evaluation for advanced systolic heart failure. Thermodilution RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. RV longitudinal strain (RVLS) by STE was assessed averaging all segments in apical 4-chamber view (global RVLS) and by averaging RV free-wall segments (free-wall RVLS). Tricuspid S' and TAPSE were also calculated. No significant correlations were found for TAPSE or tricuspid S' with RVSWI (r = 0.14; r = 0.06; respectively). Close negative correlations between global RVLS and free-wall RVLS with the RVSWI were found (r = -0.75; r = -0.82; respectively; both P < .0001). Furthermore, free-wall RVLS demonstrated the highest diagnostic accuracy (area under the receiver operating characteristic (ROC) curve 0.90) and good sensitivity and specificity of 92% and 86%, respectively, to predict depressed RVSWI using a cutoff value of less than -11.8%. CONCLUSIONS: In a group of patients referred for heart transplantation, TAPSE and tricuspid S' did not correlate with invasively obtained RVSWI. RV longitudinal deformation analysis by STE correlated well with RVSWI, providing a better estimation of RV systolic performance.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Trasplante de Corazón , Volumen Sistólico , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Derecha , Cateterismo Cardíaco/métodos , Ecocardiografía/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Derivación y Consulta , Índice de Severidad de la Enfermedad , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/cirugía
16.
Front Cardiovasc Med ; 9: 923544, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36072858

RESUMEN

The use of a left ventricular assist device (LVAD) as a bridge-to-transplantation or destination therapy to support cardiac function in patients with end-stage heart failure (HF) is increasing in all developed countries. However, the expertise needed to implant and manage patients referred for LVAD treatment is limited to a few reference centers, which are often located far from the patient's home. Although patients undergoing LVAD implantation should be permanently referred to the LVAD center for the management and follow-up of the device also after implantation, they would refer to the local healthcare service for routine assistance and urgent health issues related to the device or generic devices. Therefore, every clinician, from a bigger to a smaller center, should be prepared to manage LVAD carriers and the possible risks associated with LVAD management. Particularly, emergency treatment of patients with LVAD differs slightly from conventional emergency protocols and requires specific knowledge and a multidisciplinary approach to avoid ineffective treatment or dangerous consequences. This review aims to provide a standard protocol for managing emergency and urgency in patients with LVAD, elucidating the role of each healthcare professional and emphasizing the importance of collaboration between the emergency department, in-hospital ward, and LVAD reference center, as well as algorithms designed to ensure timely, adequate, and effective treatment to patients with LVAD.

17.
Eur Heart J Cardiovasc Imaging ; 23(6): 829-835, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34118154

RESUMEN

AIMS: In patients with heart failure (HF), chronically raised left ventricular (LV) filling pressures lead to progressive left atrial (LA) dysfunction and fibrosis. We aimed to assess the correlation of LA reservoir strain (peak atrial longitudinal strain, PALS) by speckle tracking echocardiography (STE) and LA fibrosis assessed by myocardial biopsy in patients undergoing heart transplantation (HTx). METHODS AND RESULTS: Forty-eight patients with advanced HF [mean age 51.2 ± 8.1 years, 29% females; LV ejection fraction ≤25% and New York Heart Association (NYHA) class III-IV] referred for HTx were enrolled and underwent pre-operative echocardiographic evaluation, right heart catheterization, and cardiopulmonary exercise testing. Exclusion criteria were non-sinus rhythm, mechanical ventilation, severe mitral/tricuspid regurgitation, or other valvular disease and poor acoustic window. After HTx, LA bioptic samples were collected and analysed to determine the extent of myocardial fibrosis (%). LA fibrosis showed correlation with PALS (R = -0.88, P < 0.0001), VO2max (R = -0.68, P < 0.0001), NYHA class (R = 0.66, P < 0.0001), LA stiffness (R = 0.58, P = 0.0002), and E/e' (R = 0.44, P = 0.005), while poorly correlated with E/A ratio (R = 0.23, P = 0.21). PALS had a good correlation with NYHA class (R = -0.64, P < 0.0001), PAoP (R = -0.61, P = 0.03) and VO2max (R = 0.57, P = 0.0001). Multivariate regression analysis identified PALS (beta = -0.91, P < 0.001) and LA Volume (beta = -0.19, P = 0.03) as predictors of LA Fibrosis, while E/e' was not a significant predictor (beta = 0.15, P = 0.08). CONCLUSION: Emerging as a possible index of myocardial fibrosis in patients with advanced HF, PALS could help to optimize the management and the selection of those patients with irreversible LA structural damage for advanced therapeutic strategies.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Adulto , Ecocardiografía/métodos , Femenino , Fibrosis , Atrios Cardíacos/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico
18.
Front Cardiovasc Med ; 9: 946540, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36324748

RESUMEN

Objectives: This study aimed to explore the correlation between left ventricular (LV) myocardial work (MW) indices and invasively-derived LV stroke work index (SWI) in a cohort of patients with advanced heart failure (AHF) considered for heart transplantation. Background: Left ventricular MW has emerged as a promising tool for diagnostic and prognostic purposes in heart failure (HF) but its relationship with hemodynamic data derived from right heart catheterization (RHC) has not been assessed in patients with advanced heart failure yet. Materials and methods: Consecutive patients with AHF considered for heart transplantation from 2016 to 2021 performing RHC and echocardiography as part of the workup were included. Conventional LV functional parameters and LV MW indices, including LV global work index (GWI), LV global constructive work (GCW), LV global wasted work (GWW), LV global work efficiency (GWE), and other were calculated and compared with invasively-measured LV SWI. Results: The population included 44 patients. Median time between RHC and echocardiography was 0 days (IQR: 0-24). Median age was 60 years (IQR: 54-63). For the most part, etiology of HF was non-ischemic (61.4%) and all patients were either on class NYHA II (61.4%) or III (27.3%). Median left ventricular ejection fraction was 25% (IQR: 22.3-32.3), median NT-proBNP 1,377 pg/ml (IQR: 646-2570). LV global longitudinal strain (GLS) significantly correlated with LV SWI (r = -0.337; p = 0.031), whereas, LV ejection fraction (EF) did not (r = 0.308; p = 0.050). With regard to LV MW indices, some of them demonstrated correlation with LV SWI, particularly LV GWI (r = 0.425; p = 0.006), LV GCW (r = 0.506; p = 0.001), LV global positive work (LV GPW; r = 0.464; p = 0.003) and LV global systolic constructive work (GSCW; r = 0.471; p = 0.002). Conclusion: Among LV MW indices, LV GCW correlated better with invasively-derived SWI, potentially representing a powerful tool for a more comprehensive evaluation of myocardial function.

19.
Echocardiography ; 28(6): 658-64, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21676018

RESUMEN

BACKGROUND: The right atrium (RA) plays multiple roles in the cardiac cycle. The reservoir phase of the RA is a dynamic rather than a static phase of cardiac cycle and RA deformation is dependent on pulmonary pressures exerted on the right ventricle and, therefore, backwards on the RA. The purpose of this study was to assess the accuracy and the clinical applicability of the speckle tracking echocardiography (STE) evaluation of the RA in predicting the invasive systolic pulmonary artery pressure (SPAP) in patients with systolic heart failure (HF) undergoing right heart catheterization (RHC). METHODS: Thirty-one hemodynamically stable, in-clinic HF patients who were undergoing RHC were included. Doppler echocardiography and RHC catheterization were simultaneously performed. Echocardiographic measures and STE where obtained as peak atrial longitudinal strain (PALS), RA strain rate, and time to peak longitudinal strain (TPLS). RA PALS was inversely correlated with invasively assessed SPAP (r =-0.81; P < 0.001) while RA strain directly correlated with SPAP (r = 0.82; P < 0.001). RA PALS and strain rate retained this correlation even after nitroprusside challenge test (r =-0.81; P < 0.001 and r = 0.91; P < 0.001, respectively). Area under the curve optimal cutoffs for predicting the SPAP > 50 mmHg were for RA PALS 10.3% (AUC:0.93, sensitivity: 100%, specificity: 78%). CONCLUSION: RA STE showed a significant correlation with pulmonary pressure. RA assessment with STE can predict pulmonary artery hypertension in HF patients. This result is consistent with nitroprusside challenge test. Although RA STE is not routinely used, its evaluation may implement right heart evaluation in HF patients.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Atrios Cardíacos/diagnóstico por imagen , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico por imagen , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/etiología , Determinación de la Presión Sanguínea/métodos , Enfermedad Crónica , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
J Cardiol Cases ; 24(3): 106-109, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34466171

RESUMEN

Despite the exponential increase in venoarterial extracorporeal membrane oxygenation (VA-ECMO) use during the past decade, adult cardiac ECMO is still accompanied by a high mortality rate. Moreover, although left ventricular distension is now a well-known drawback of VA-ECMO, there seems to be great variability in the hemodynamic management strategies and in the results reported among the various centers. Hemodynamic management of VA-ECMO can be even more challenging when complex configurations are deployed. Here we present and discuss an interesting case of a modified VA-ECMO that although it occurred a few years ago it is instructive for its hemodynamic implications and pitfalls. VA-ECMO can either save the patient or catalyze the deterioration of a compromised clinical condition and thus a close multiparametric monitoring is mandatory especially with complex ECMO arrangements. A thorough understanding of the hemodynamic changes and problems that may occur during these cases is necessary too. Ultimately, critical thinking along with a proactive approach for early referral to more specialized centers and immediate unloading of the left ventricle whenever it is deemed necessary, together may contribute to reduce the relatively high mortality rate with this type of support. .

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA