Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Anat Rec (Hoboken) ; 298(8): 1408-15, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25810349

RESUMEN

The hyoid bone anchors and supports the vocal tract. Its complex shape is best studied in three dimensions, but it is difficult to capture on computed tomography (CT) images and three-dimensional volume renderings. The goal of this study was to determine the optimal CT scanning and rendering parameters to accurately measure the growth and developmental anatomy of the hyoid and to determine whether it is feasible and necessary to use these parameters in the measurement of hyoids from in vivo CT scans. Direct linear and volumetric measurements of skeletonized hyoid bone specimens were compared with corresponding CT images to determine the most accurate scanning parameters and three-dimensional rendering techniques. A pilot study was undertaken using in vivo scans from a retrospective CT database to determine feasibility of quantifying hyoid growth. Scanning parameters and rendering technique affected accuracy of measurements. Most linear CT measurements were within 10% of direct measurements; however, volume was overestimated when CT scans were acquired with a slice thickness greater than 1.25 mm. Slice-by-slice thresholding of hyoid images decreased volume overestimation. The pilot study revealed that the linear measurements tested correlate with age. A fine-tuned rendering approach applied to small slice thickness CT scans produces the most accurate measurements of hyoid bones. However, linear measurements can be accurately assessed from in vivo CT scans at a larger slice thickness. Such findings imply that investigation into the growth and development of the hyoid bone, and the vocal tract as a whole, can now be performed using these techniques.


Asunto(s)
Desarrollo Óseo , Hueso Hioides/diagnóstico por imagen , Imagenología Tridimensional , Interpretación de Imagen Radiográfica Asistida por Computador , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Factores de Edad , Bases de Datos Factuales , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Hueso Hioides/crecimiento & desarrollo , Modelos Lineales , Masculino , Persona de Mediana Edad , Proyectos Piloto , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
2.
Indian J Plast Surg ; 41(2): 200, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19753264
3.
Artículo en Inglés | MEDLINE | ID: mdl-23601224

RESUMEN

OBJECTIVES: This study investigates the effect of scanning parameters on the accuracy of measurements from three-dimensional (3D), multi-detector computed tomography (MDCT) mandible renderings. A broader range of acceptable parameters can increase the availability of computed tomographic (CT) studies for retrospective analysis. STUDY DESIGN: Three human mandibles and a phantom object were scanned using 18 combinations of slice thickness, field of view (FOV), and reconstruction algorithm and 3 different threshold-based segmentations. Measurements of 3D computed tomography (3DCT) models and specimens were compared. RESULTS: Linear and angular measurements were accurate, irrespective of scanner parameters or rendering technique. Volume measurements were accurate with a slice thickness of 1.25 mm, but not 2.5 mm. Surface area measurements were consistently inflated. CONCLUSIONS: Linear, angular, and volumetric measurements of mandible 3D MDCT models can be confidently obtained from a range of parameters and rendering techniques. Slice thickness is the primary factor affecting volume measurements. These findings should also apply to 3D rendering using cone-beam CT (CBCT).


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Mandíbula/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Tomógrafos Computarizados por Rayos X , Adulto , Algoritmos , Proceso Alveolar/anatomía & histología , Proceso Alveolar/diagnóstico por imagen , Puntos Anatómicos de Referencia/anatomía & histología , Puntos Anatómicos de Referencia/diagnóstico por imagen , Cefalometría/métodos , Cefalometría/estadística & datos numéricos , Niño , Mentón/anatomía & histología , Mentón/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Imagenología Tridimensional/estadística & datos numéricos , Mandíbula/anatomía & histología , Cóndilo Mandibular/anatomía & histología , Cóndilo Mandibular/diagnóstico por imagen , Tomografía Computarizada Multidetector/instrumentación , Tomografía Computarizada Multidetector/estadística & datos numéricos , Fantasmas de Imagen , Polímeros , Estándares de Referencia , Estudios Retrospectivos
4.
J Craniofac Surg ; 17(1): 162-6, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16432426

RESUMEN

Midline dermoid cysts, although rare, typically present as nasal or glabellar masses with potential sinus tract extension to the skin or to the central nervous system. Craniofacial dermoid cysts present in varied ways, including asymptomatic puncti, infection, or seizure secondary to intracranial invasion. This article describes the previously unreported occurrence of a midline dermoid within the labial frenulum diagnosed on surgical excision of the cyst and its orocutaneous sinus tract, which extended to the skin at the base of the columella.


Asunto(s)
Fístula Cutánea/patología , Quiste Dermoide/patología , Frenillo Labial/patología , Enfermedades de los Labios/patología , Neoplasias de los Labios/patología , Fístula Oral/patología , Humanos , Lactante , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA