Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am J Physiol Heart Circ Physiol ; 318(4): H747-H755, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32108522

RESUMEN

This study tested the hypothesis that (pyr)apelin-13 dose-dependently augments myocardial contractility and coronary blood flow, irrespective of changes in systemic hemodynamics. Acute effects of intravenous (pyr)apelin-13 administration (10 to 1,000 nM) on blood pressure, heart rate, left ventricular pressure and volume, and coronary parameters were measured in dogs and pigs. Administration of (pyr)apelin-13 did not influence blood pressure (P = 0.59), dP/dtmax (P = 0.26), or dP/dtmin (P = 0.85) in dogs. However, heart rate dose-dependently increased > 70% (P < 0.01), which was accompanied by a significant increase in coronary blood flow (P < 0.05) and reductions in left ventricular end-diastolic volume and stroke volume (P < 0.001). In contrast, (pyr)apelin-13 did not significantly affect hemodynamics, coronary blood flow, or indexes of contractile function in pigs. Furthermore, swine studies found no effect of intracoronary (pyr)apelin-13 administration on coronary blood flow (P = 0.83) or vasorelaxation in isolated, endothelium-intact (P = 0.89) or denuded (P = 0.38) coronary artery rings. Examination of all data across (pyr)apelin-13 concentrations revealed an exponential increase in cardiac output as peripheral resistance decreased across pigs and dogs (P < 0.001; R2 = 0.78). Assessment of the Frank-Starling relationship demonstrated a significant linear relationship between left ventricular end-diastolic volume and stroke volume across species (P < 0.001; R2 = 0.70). Taken together, these findings demonstrate that (pyr)apelin-13 does not directly influence myocardial contractility or coronary blood flow in either dogs or pigs.NEW & NOTEWORTHY Our findings provide much needed insight regarding the pharmacological cardiac and coronary effects of (pyr)apelin-13 in larger animal preparations. In particular, data highlight distinct hemodynamic responses of apelin across species, which are independent of any direct effect on myocardial contractility or perfusion.


Asunto(s)
Circulación Coronaria/efectos de los fármacos , Péptidos y Proteínas de Señalización Intercelular/farmacología , Contracción Miocárdica/efectos de los fármacos , Animales , Presión Sanguínea , Vasos Coronarios/efectos de los fármacos , Perros , Frecuencia Cardíaca , Masculino , Volumen Sistólico , Porcinos , Vasodilatación
2.
Am J Physiol Heart Circ Physiol ; 310(6): H693-704, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26825518

RESUMEN

Hydrogen peroxide (H2O2) and voltage-dependent K(+) (KV) channels play key roles in regulating coronary blood flow in response to metabolic, ischemic, and paracrine stimuli. The KV channels responsible have not been identified, but KV7 channels are possible candidates. Existing data regarding KV7 channel function in the coronary circulation (limited to ex vivo assessments) are mixed. Thus we examined the hypothesis that KV7 channels are present in cells of the coronary vascular wall and regulate vasodilation in swine. We performed a variety of molecular, biochemical, and functional (in vivo and ex vivo) studies. Coronary arteries expressed KCNQ genes (quantitative PCR) and KV7.4 protein (Western blot). Immunostaining demonstrated KV7.4 expression in conduit and resistance vessels, perhaps most prominently in the endothelial and adventitial layers. Flupirtine, a KV7 opener, relaxed coronary artery rings, and this was attenuated by linopirdine, a KV7 blocker. Endothelial denudation inhibited the flupirtine-induced and linopirdine-sensitive relaxation of coronary artery rings. Moreover, linopirdine diminished bradykinin-induced endothelial-dependent relaxation of coronary artery rings. There was no effect of intracoronary flupirtine or linopirdine on coronary blood flow at the resting heart rate in vivo. Linopirdine had no effect on coronary vasodilation in vivo elicited by ischemia, H2O2, or tachycardia. However, bradykinin increased coronary blood flow in vivo, and this was attenuated by linopirdine. These data indicate that KV7 channels are expressed in some coronary cell type(s) and influence endothelial function. Other physiological functions of coronary vascular KV7 channels remain unclear, but they do appear to contribute to endothelium-dependent responses to paracrine stimuli.


Asunto(s)
Circulación Coronaria/fisiología , Vasos Coronarios/metabolismo , Canales de Potasio KCNQ/genética , Comunicación Paracrina/fisiología , Adventicia/metabolismo , Aminopiridinas/farmacología , Animales , Western Blotting , Bradiquinina/farmacología , Circulación Coronaria/efectos de los fármacos , Vasos Coronarios/efectos de los fármacos , Endotelio Vascular/metabolismo , Indoles/farmacología , Canales de Potasio KCNQ/metabolismo , Canal de Potasio KCNQ1/genética , Canal de Potasio KCNQ2/genética , Canal de Potasio KCNQ3/genética , Bloqueadores de los Canales de Potasio/farmacología , Piridinas/farmacología , Reacción en Cadena en Tiempo Real de la Polimerasa , Porcinos , Vasoconstricción/efectos de los fármacos , Vasodilatación/efectos de los fármacos , Vasodilatadores/farmacología
3.
J Biomech Eng ; 138(6): 061003, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27040732

RESUMEN

There is a significant need for fixed biological tissues with desired structural and material constituents for tissue engineering applications. Here, we introduce the lung ligament as a fixed biological material that may have clinical utility for tissue engineering. To characterize the lung tissue for potential clinical applications, we studied glutaraldehyde-treated porcine pulmonary ligament (n = 11) with multiphoton microscopy (MPM) and conducted biaxial planar experiments to characterize the mechanical property of the tissue. The MPM imaging revealed that there are generally two families of collagen fibers distributed in two distinct layers: The first family largely aligns along the longitudinal direction with a mean angle of θ = 10.7 ± 9.3 deg, while the second one exhibits a random distribution with a mean θ = 36.6 ± 27.4. Elastin fibers appear in some intermediate sublayers with a random orientation distribution with a mean θ = 39.6 ± 23 deg. Based on the microstructural observation, a microstructure-based constitutive law was proposed to model the elastic property of the tissue. The material parameters were identified by fitting the model to the biaxial stress-strain data of specimens, and good fitting quality was achieved. The parameter e0 (which denotes the strain beyond which the collagen can withstand tension) of glutaraldehyde-treated tissues demonstrated low variability implying a relatively consistent collagen undulation in different samples, while the stiffness parameters for elastin and collagen fibers showed relatively greater variability. The fixed tissues presented a smaller e0 than that of fresh specimen, confirming that glutaraldehyde crosslinking increases the mechanical strength of collagen-based biomaterials. The present study sheds light on the biomechanics of glutaraldehyde-treated porcine pulmonary ligament that may be a candidate for tissue engineering.


Asunto(s)
Glutaral/farmacología , Ligamentos/efectos de los fármacos , Ligamentos/metabolismo , Pulmón/efectos de los fármacos , Pulmón/metabolismo , Fenómenos Mecánicos/efectos de los fármacos , Porcinos , Animales , Fenómenos Biomecánicos/efectos de los fármacos , Colágeno/metabolismo , Elastina/metabolismo , Ligamentos/fisiología , Pulmón/fisiología , Estrés Mecánico , Ingeniería de Tejidos , Soporte de Peso
4.
Catheter Cardiovasc Interv ; 86(1): 136-43, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25510238

RESUMEN

BACKGROUND: Inaccurate aortic valve sizing and selection is linked to paravalvular leakage in transcatheter aortic valve replacement (TAVR). Here, a novel sizing valvuloplasty conductance balloon (SVCB) catheter is shown to be accurate, reproducible, unbiased, and provides real-time tool for aortic valve sizing that fits within the standard valvuloplasty procedure. METHODS AND RESULTS: The SVCB catheter is a valvuloplasty device that uses real-time electrical conductance measurements based on Ohm's Law to size the balloon opposed against the aortic valve at any given inflation pressure. Accuracy and repeatability of the SVCB catheter was performed on the bench in phantoms of known dimension and ex vivo in three domestic swine aortic annuli with comparison to computed tomography (CT) and dilator measurements. Procedural workflow and safety was demonstrated in vivo in three additional domestic swine. SVCB catheter measurements had negligible bias or error for bench accuracy considered as the gold standard (Bias: -0.11 ± 0.26 mm; Error: 1.2%), but greater disagreement in ex vivo versus dilators (Bias: -0.3 ± 1.1 mm; Error: 4.5%), and ex vivo versus CT (Bias: -1.0 ± 1.6 mm; Error: 8.7%). The dilator versus CT accuracy showed similar agreement (Bias: -0.9 ± 1.5 mm; Error: 7.3%). Repeatability was excellent on the bench (Bias: 0.02 ± 0.12 mm; Error: 0.5%) and ex vivo (Bias: -0.4 ± 0.9 mm; Error: 4.6%). In animal studies, the device fit well within the procedural workflow with no adverse events or complications. CONCLUSIONS: Due to the clinical relevance of this accurate, repeatable, unbiased, and real-time sizing measurement, the SVCB catheter may provide a useful tool prior to TAVR. These findings merit a future human study.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/instrumentación , Prótesis Valvulares Cardíacas , Animales , Estenosis de la Válvula Aórtica/diagnóstico , Modelos Animales de Enfermedad , Ecocardiografía Transesofágica , Diseño de Equipo , Diseño de Prótesis , Porcinos , Tomografía Computarizada por Rayos X
5.
Circulation ; 128(1): 9-18, 2013 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-23685742

RESUMEN

BACKGROUND: This investigation examined the mechanisms by which coronary perivascular adipose tissue (PVAT)-derived factors influence vasomotor tone and the PVAT proteome in lean versus obese swine. METHODS AND RESULTS: Coronary arteries from Ossabaw swine were isolated for isometric tension studies. We found that coronary (P=0.03) and mesenteric (P=0.04) but not subcutaneous adipose tissue augmented coronary contractions to KCl (20 mmol/L). Inhibition of CaV1.2 channels with nifedipine (0.1 µmol/L) or diltiazem (10 µmol/L) abolished this effect. Coronary PVAT increased baseline tension and potentiated constriction of isolated arteries to prostaglandin F2α in proportion to the amount of PVAT present (0.1-1.0 g). These effects were elevated in tissues obtained from obese swine and were observed in intact and endothelium denuded arteries. Coronary PVAT also diminished H2O2-mediated vasodilation in lean and, to a lesser extent, in obese arteries. These effects were associated with alterations in the obese coronary PVAT proteome (detected 186 alterations) and elevated voltage-dependent increases in intracellular [Ca(2+)] in obese smooth muscle cells. Further studies revealed that the Rho-kinase inhibitor fasudil (1 µmol/L) significantly blunted artery contractions to KCl and PVAT in lean but not obese swine. Calpastatin (10 µmol/L) also augmented contractions to levels similar to that observed in the presence of PVAT. CONCLUSIONS: Vascular effects of PVAT vary according to anatomic location and are influenced by an obese phenotype. Augmented contractile effects of obese coronary PVAT are related to alterations in the PVAT proteome (eg, calpastatin), Rho-dependent signaling, and the functional contribution of K(+) and CaV1.2 channels to smooth muscle tone.


Asunto(s)
Enfermedad de la Arteria Coronaria/fisiopatología , Grasa Intraabdominal/fisiopatología , Músculo Liso Vascular/fisiopatología , Obesidad/fisiopatología , Vasoconstricción/fisiología , Animales , Peso Corporal/fisiología , Proteínas de Unión al Calcio/farmacología , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/fisiopatología , Inhibidores de Cisteína Proteinasa/farmacología , Modelos Animales de Enfermedad , Grasa Intraabdominal/patología , Contracción Isométrica/efectos de los fármacos , Contracción Isométrica/fisiología , Arterias Mesentéricas/fisiopatología , Músculo Liso Vascular/patología , Obesidad/patología , Proteómica , Grasa Subcutánea/patología , Grasa Subcutánea/fisiopatología , Sus scrofa , Vasoconstricción/efectos de los fármacos
6.
Microcirculation ; 21(2): 104-11, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24033762

RESUMEN

OBJECTIVE: This study examined the mechanisms by which H2 S modulates coronary microvascular resistance and myocardial perfusion at rest and in response to cardiac ischemia. METHODS: Experiments were conducted in isolated coronary arteries and in open-chest anesthetized dogs. RESULTS: We found that the H2 S substrate l-cysteine (1-10 mM) did not alter coronary tone of isolated arteries in vitro or coronary blood flow in vivo. In contrast, intracoronary (ic) H2 S (0.1-3 mM) increased coronary flow from 0.49 ± 0.08 to 2.65 ± 0.13 mL/min/g (p < 0.001). This increase in flow was unaffected by inhibition of Kv channels with 4-aminopyridine (p = 0.127) but was attenuated (0.23 ± 0.02-1.13 ± 0.13 mL/min/g) by the KATP channel antagonist glibenclamide (p < 0.001). Inhibition of NO synthesis (l-NAME) did not attenuate coronary responses to H2 S. Immunohistochemistry revealed expression of CSE, an endogenous H2 S enzyme, in myocardium. Inhibition of CSE with ß-cyano-l-alanine (10 µM) had no effect on baseline coronary flow or responses to a 15-second coronary occlusion (p = 0.82). CONCLUSIONS: These findings demonstrate that exogenous H2 S induces potent, endothelial-independent dilation of the coronary microcirculation predominantly through the activation of KATP channels, however, our data do not support a functional role for endogenous H2 S in the regulation of coronary microvascular resistance.


Asunto(s)
Circulación Coronaria/efectos de los fármacos , Gasotransmisores/farmacología , Sulfuro de Hidrógeno/farmacología , Microcirculación/efectos de los fármacos , Isquemia Miocárdica , Animales , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Perros , Femenino , Masculino , Isquemia Miocárdica/metabolismo , Isquemia Miocárdica/fisiopatología , Miocardio/metabolismo
7.
Basic Res Cardiol ; 108(4): 365, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23764734

RESUMEN

Glucagon-like peptide 1 (GLP-1) has insulin-like effects on myocardial glucose uptake which may contribute to its beneficial effects in the setting of myocardial ischemia. Whether these effects are different in the setting of obesity or type 2 diabetes (T2DM) requires investigation. We examined the cardiometabolic actions of GLP-1 (7-36) in lean and obese/T2DM humans, and in lean and obese Ossabaw swine. GLP-1 significantly augmented myocardial glucose uptake under resting conditions in lean humans, but this effect was impaired in T2DM. This observation was confirmed and extended in swine, where GLP-1 effects to augment myocardial glucose uptake during exercise were seen in lean but not in obese swine. GLP-1 did not increase myocardial oxygen consumption or blood flow in humans or in swine. Impaired myocardial responsiveness to GLP-1 in obesity was not associated with any apparent alterations in myocardial or coronary GLP1-R expression. No evidence for GLP-1-mediated activation of cAMP/PKA or AMPK signaling in lean or obese hearts was observed. GLP-1 treatment augmented p38-MAPK activity in lean, but not obese cardiac tissue. Taken together, these data provide novel evidence indicating that the cardiometabolic effects of GLP-1 are attenuated in obesity and T2DM, via mechanisms that may involve impaired p38-MAPK signaling.


Asunto(s)
Diabetes Mellitus Tipo 2/metabolismo , Péptido 1 Similar al Glucagón/farmacología , Péptido 1 Similar al Glucagón/uso terapéutico , Glucosa/metabolismo , Incretinas/farmacología , Incretinas/uso terapéutico , Miocardio/metabolismo , Obesidad/metabolismo , Adulto , Animales , Comorbilidad , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Modelos Animales de Enfermedad , Femenino , Hemodinámica/efectos de los fármacos , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Obesidad/epidemiología , Consumo de Oxígeno/efectos de los fármacos , Consumo de Oxígeno/fisiología , Condicionamiento Físico Animal/fisiología , Flujo Sanguíneo Regional/efectos de los fármacos , Flujo Sanguíneo Regional/fisiología , Descanso/fisiología , Transducción de Señal/efectos de los fármacos , Transducción de Señal/fisiología , Porcinos , Resultado del Tratamiento , Proteínas Quinasas p38 Activadas por Mitógenos/metabolismo
8.
Basic Res Cardiol ; 108(5): 370, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23856709

RESUMEN

Previous investigations indicate that diminished functional expression of voltage-dependent K(+) (KV) channels impairs control of coronary blood flow in obesity/metabolic syndrome. The goal of this investigation was to test the hypothesis that KV channels are electromechanically coupled to CaV1.2 channels and that coronary microvascular dysfunction in obesity is related to subsequent increases in CaV1.2 channel activity. Initial studies revealed that inhibition of KV channels with 4-aminopyridine (4AP, 0.3 mM) increased intracellular [Ca(2+)], contracted isolated coronary arterioles and decreased coronary reactive hyperemia. These effects were reversed by blockade of CaV1.2 channels. Further studies in chronically instrumented Ossabaw swine showed that inhibition of CaV1.2 channels with nifedipine (10 µg/kg, iv) had no effect on coronary blood flow at rest or during exercise in lean swine. However, inhibition of CaV1.2 channels significantly increased coronary blood flow, conductance, and the balance between coronary flow and metabolism in obese swine (P < 0.05). These changes were associated with a ~50 % increase in inward CaV1.2 current and elevations in expression of the pore-forming subunit (α1c) of CaV1.2 channels in coronary smooth muscle cells from obese swine. Taken together, these findings indicate that electromechanical coupling between KV and CaV1.2 channels is involved in the regulation of coronary vasomotor tone and that increases in CaV1.2 channel activity contribute to coronary microvascular dysfunction in the setting of obesity.


Asunto(s)
Canales de Calcio Tipo L/metabolismo , Circulación Coronaria/fisiología , Obesidad/metabolismo , Obesidad/fisiopatología , Canales de Potasio/metabolismo , Animales , Hemodinámica/fisiología , Porcinos
9.
J Mol Cell Cardiol ; 52(4): 848-56, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21767548

RESUMEN

Metabolic syndrome (MetS) is a collection of risk factors including obesity, dyslipidemia, insulin resistance/impaired glucose tolerance, and/or hypertension. The incidence of obesity has reached pandemic levels, as ~20-30% of adults in most developed countries can be classified as having MetS. This increased prevalence of MetS is critical as it is associated with a two-fold elevated risk for cardiovascular disease. Although the pathophysiology underlying this increase in disease has not been clearly defined, recent evidence indicates that alterations in the control of coronary blood flow could play an important role. The purpose of this review is to highlight current understanding of the effects of MetS on regulation of coronary blood flow and to outline the potential mechanisms involved. In particular, the role of neurohumoral modulation via sympathetic α-adrenoceptors and the renin-angiotensin-aldosterone system (RAAS) are explored. Alterations in the contribution of end-effector K(+), Ca(2+), and transient receptor potential (TRP) channels are also addressed. Finally, future perspectives and potential therapeutic targeting of the microcirculation in MetS are discussed. This article is part of a Special Issue entitled "Coronary Blood Flow".


Asunto(s)
Circulación Coronaria/fisiología , Síndrome Metabólico/fisiopatología , Animales , Enfermedades Cardiovasculares/metabolismo , Enfermedades Cardiovasculares/fisiopatología , Humanos , Síndrome Metabólico/metabolismo , Obesidad/metabolismo , Obesidad/fisiopatología , Sistema Renina-Angiotensina/fisiología
10.
J Mol Cell Cardiol ; 52(4): 912-9, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21771599

RESUMEN

The purpose of this investigation was to test the hypothesis that K(V) channels contribute to metabolic control of coronary blood flow and that decreases in K(V) channel function and/or expression significantly attenuate myocardial oxygen supply-demand balance in the metabolic syndrome (MetS). Experiments were conducted in conscious, chronically instrumented Ossabaw swine fed either a normal maintenance diet or an excess calorie atherogenic diet that produces the clinical phenotype of early MetS. Data were obtained under resting conditions and during graded treadmill exercise before and after inhibition of K(V) channels with 4-aminopyridine (4-AP, 0.3mg/kg, iv). In lean-control swine, 4-AP reduced coronary blood flow ~15% at rest and ~20% during exercise. Inhibition of K(V) channels also increased aortic pressure (P<0.01) while reducing coronary venous PO(2) (P<0.01) at a given level of myocardial oxygen consumption (MVO(2)). Administration of 4-AP had no effect on coronary blood flow, aortic pressure, or coronary venous PO(2) in swine with MetS. The lack of response to 4-AP in MetS swine was associated with a ~20% reduction in coronary K(V) current (P<0.01) and decreased expression of K(V)1.5 channels in coronary arteries (P<0.01). Together, these data demonstrate that K(V) channels play an important role in balancing myocardial oxygen delivery with metabolism at rest and during exercise-induced increases in MVO(2). Our findings also indicate that decreases in K(V) channel current and expression contribute to impaired control of coronary blood flow in the MetS. This article is part of a Special Issue entitled "Coronary Blood Flow".


Asunto(s)
Circulación Coronaria/fisiología , Vasos Coronarios/metabolismo , Vasos Coronarios/fisiología , Canales de Potasio/metabolismo , 4-Aminopiridina/farmacología , Animales , Western Blotting , Circulación Coronaria/efectos de los fármacos , Vasos Coronarios/efectos de los fármacos , Electrofisiología , Hemodinámica/efectos de los fármacos , Hemodinámica/fisiología , Miocardio/metabolismo , Consumo de Oxígeno/efectos de los fármacos , Consumo de Oxígeno/fisiología , Esfuerzo Físico/fisiología , Bloqueadores de los Canales de Potasio/farmacología , Porcinos
11.
J Pharmacol Exp Ther ; 342(2): 453-60, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22580348

RESUMEN

Large conductance, Ca(2+)/voltage-sensitive K(+) channels (BK channels) are well characterized, but their physiological roles, often determined through pharmacological manipulation, are less clear. Iberiotoxin is considered the "gold standard" antagonist, but cost and membrane-impermeability limit its usefulness. Economical and membrane-permeable alternatives could facilitate the study of BK channels. Thus, we characterized the effect of penitrem A, a tremorigenic mycotoxin, on BK channels and demonstrate its utility for studying vascular function in vitro and in vivo. Whole-cell currents from human embryonic kidney 293 cells transfected with hSlo α or α + ß1 were blocked >95% by penitrem A (IC(50) 6.4 versus 64.4 nM; p < 0.05). Furthermore, penitrem A inhibited BK channels in inside-out and cell-attached patches, whereas iberiotoxin could not. Inhibitory effects of penitrem A on whole-cell K(+) currents were equivalent to iberiotoxin in canine coronary smooth muscle cells. As for specificity, penitrem A had no effect on native delayed rectifier K(+) currents, cloned voltage-dependent Kv1.5 channels, or native ATP-dependent K(ATP) current. Penitrem A enhanced the sensitivity to K(+)-induced contraction in canine coronary arteries by 23 ± 5% (p < 0.05) and increased the blood pressure response to phenylephrine in anesthetized mice by 36 ± 11% (p < 0.05). Our data indicate that penitrem A is a useful tool for studying the role of BK channels in vascular function and is practical for cell and tissue (in vitro) studies as well as anesthetized animal (in vivo) experiments.


Asunto(s)
Canales de Potasio de Gran Conductancia Activados por el Calcio/antagonistas & inhibidores , Músculo Liso Vascular/efectos de los fármacos , Músculo Liso Vascular/fisiología , Micotoxinas/farmacología , Miocitos del Músculo Liso/fisiología , Animales , Presión Sanguínea/efectos de los fármacos , Presión Sanguínea/fisiología , Línea Celular Transformada , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/metabolismo , Vasos Coronarios/fisiología , Perros , Células HEK293 , Humanos , Canales de Potasio de Gran Conductancia Activados por el Calcio/metabolismo , Masculino , Ratones , Ratones Endogámicos C57BL , Músculo Liso Vascular/metabolismo , Miocitos del Músculo Liso/efectos de los fármacos , Miocitos del Músculo Liso/metabolismo , Péptidos/farmacología , Fenilefrina/farmacología , Potasio/metabolismo , Porcinos , Vasoconstricción/efectos de los fármacos , Vasoconstricción/fisiología
12.
Basic Res Cardiol ; 107(3): 264, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22466959

RESUMEN

The mechanisms responsible for coronary pressure-flow autoregulation, a critical physiologic phenomenon that maintains coronary blood flow relatively constant in the presence of changes in perfusion pressure, remain poorly understood. This investigation tested the hypothesis that voltage-sensitive K(+) (K(V)) and Ca(2+) (Ca(V)1.2) channels play a critical role in coronary pressure-flow autoregulation in vivo. Experiments were performed in open-chest, anesthetized Ossabaw swine during step changes in coronary perfusion pressure (CPP) from 40 to 140 mmHg before and during inhibition of K(V) channels with 4-aminopyridine (4AP, 0.3 mM, ic) or Ca(V)1.2 channels with diltiazem (10 µg/min, ic). 4AP significantly decreased vasodilatory responses to H(2)O(2) (0.3-10 µM, ic) and coronary flow at CPPs = 60-140 mmHg. This decrease in coronary flow was associated with diminished ventricular contractile function (dP/dT) and myocardial oxygen consumption. However, the overall sensitivity to changes in CPP from 60 to 100 mmHg (i.e. autoregulatory gain; Gc) was unaltered by 4-AP administration (Gc = 0.46 ± 0.11 control vs. 0.46 ± 0.06 4-AP). In contrast, inhibition of Ca(V)1.2 channels progressively increased coronary blood flow at CPPs > 80 mmHg and substantially diminished coronary Gc to -0.20 ± 0.11 (P < 0.01), with no effect on contractile function or oxygen consumption. Taken together, these findings demonstrate that (1) K(V) channels tonically contribute to the control of microvascular resistance over a wide range of CPPs, but do not contribute to coronary responses to changes in pressure; (2) progressive activation of Ca(V)1.2 channels with increases in CPP represents a critical mechanism of coronary pressure-flow autoregulation.


Asunto(s)
Presión Sanguínea , Canales de Calcio Tipo L/metabolismo , Circulación Coronaria , Vasos Coronarios/metabolismo , Mecanotransducción Celular , Canales de Potasio con Entrada de Voltaje/metabolismo , Animales , Presión Sanguínea/efectos de los fármacos , Bloqueadores de los Canales de Calcio/farmacología , Canales de Calcio Tipo L/efectos de los fármacos , Circulación Coronaria/efectos de los fármacos , Vasos Coronarios/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Homeostasis , Mecanotransducción Celular/efectos de los fármacos , Microcirculación , Contracción Miocárdica , Miocardio/metabolismo , Consumo de Oxígeno , Bloqueadores de los Canales de Potasio/farmacología , Canales de Potasio con Entrada de Voltaje/antagonistas & inhibidores , Porcinos , Factores de Tiempo , Resistencia Vascular , Vasodilatación , Vasodilatadores/farmacología , Función Ventricular
13.
J Pharmacol Exp Ther ; 339(2): 329-40, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21795434

RESUMEN

Circulating hormones stimulate the phospholipase Cß (PLC)/Ca(2+) influx pathway to regulate numerous cell functions, including vascular tone. It was proposed previously that Ca(2+)-independent phospholipase A(2) (iPLA(2))-dependent store-operated Ca(2+) influx channels mediate hormone-induced contractions in isolated arteries, because bromoenol lactone (BEL), a potent irreversible inhibitor of iPLA(2), inhibited such contractions. However, the effects of BEL on other channels implicated in mediating hormone-induced vessel contractions, specifically voltage-gated Ca(2+) (Ca(V)1.2) and transient receptor potential canonical (TRPC) channels, have not been defined clearly. Using isometric tension measurements, we found that thapsigargin-induced contractions were ∼34% of those evoked by phenylephrine or KCl. BEL completely inhibited not only thapsigargin- but also phenylephrine- and KCl-induced ring contractions, suggesting that Ca(V)1.2 and receptor-operated TRPC channels also may be sensitive to BEL. Therefore, we investigated the effects of BEL on heterologously expressed Ca(V)1.2 and TRPC channels in human embryonic kidney cells, a model system that allows probing of individual protein function without interference from other signaling elements of native cells. We found that low micromolar concentrations of BEL inhibited Ca(V)1.2, TRPC5, TRPC6, and heteromeric TRPC1-TRPC5 channels in an iPLA(2)-independent manner. BEL also attenuated PLC activity, suggesting that the compound may inhibit TRPC channel activity in part by interfering with an initial PLC-dependent step required for TRPC channel activation. Conversely, BEL did not affect endogenous voltage-gated K(+) channels in human embryonic kidney cells. Our findings support the hypothesis that iPLA(2)-dependent store-operated Ca(2+) influx channels and iPLA(2)-independent hormone-operated TRPC channels can serve as smooth muscle depolarization triggers to activate Ca(V)1.2 channels and to regulate vascular tone.


Asunto(s)
Canales de Calcio/metabolismo , Naftalenos/farmacología , Inhibidores de Fosfodiesterasa/farmacología , Pironas/farmacología , Canales de Potencial de Receptor Transitorio/metabolismo , Animales , Conducta Adictiva/fisiopatología , Carbazoles/farmacología , Cocaína/efectos adversos , Cocaína/farmacología , Condicionamiento Operante/efectos de los fármacos , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/antagonistas & inhibidores , Inhibidores de Captación de Dopamina/efectos adversos , Inhibidores de Captación de Dopamina/farmacología , Relación Dosis-Respuesta a Droga , Humanos , Masculino , Fosfolipasas/metabolismo , Ensayo de Unión Radioligante , Ratas , Ratas Sprague-Dawley , Receptores sigma/análisis , Receptores sigma/antagonistas & inhibidores , Receptores sigma/efectos de los fármacos , Autoadministración , Porcinos , Tapsigargina/farmacología
14.
Am J Physiol Heart Circ Physiol ; 298(4): H1182-9, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20118408

RESUMEN

This investigation tested the hypothesis that metabolic syndrome decreases the relative contribution of specific K(+) channels to coronary reactive hyperemia. Ca(2+)-activated (BK(Ca)), voltage-activated (K(V)), and ATP-dependent (K(ATP)) K(+) channels were investigated. Studies were conducted in anesthetized miniature Ossabaw swine fed a normal maintenance diet (11% kcal from fat) or an excess calorie atherogenic diet (43% kcal from fat, 2% cholesterol, 20% kcal from fructose) for 20 wk. The latter diet induces metabolic syndrome, increasing body weight, fasting glucose, total cholesterol, and triglyceride levels. Ischemic vasodilation was determined by the coronary flow response to a 15-s occlusion before and after cumulative administration of antagonists for BK(Ca) (penitrem A; 10 microg/kg iv), K(V) (4-aminopyridine; 0.3 mg/kg iv) and K(ATP) (glibenclamide; 1 mg/kg iv) channels. Coronary reactive hyperemia was diminished by metabolic syndrome as the repayment of flow debt was reduced approximately 30% compared with lean swine. Inhibition of BK(Ca) channels had no effect on reactive hyperemia in either lean or metabolic syndrome swine. Subsequent inhibition of K(V) channels significantly reduced the repayment of flow debt ( approximately 25%) in both lean and metabolic syndrome swine. Additional blockade of K(ATP) channels further diminished ( approximately 45%) the repayment of flow debt in lean but not metabolic syndrome swine. These data indicate that the metabolic syndrome impairs coronary vasodilation in response to cardiac ischemia via reductions in the contribution of K(+) channels to reactive hyperemia.


Asunto(s)
Vasos Coronarios/fisiopatología , Síndrome Metabólico/fisiopatología , Isquemia Miocárdica/fisiopatología , Canales de Potasio/fisiología , Vasodilatación/fisiología , Animales , Presión Sanguínea/fisiología , Vasos Coronarios/diagnóstico por imagen , Modelos Animales de Enfermedad , Femenino , Hiperemia/fisiopatología , Canales KATP/fisiología , Subunidades alfa de los Canales de Potasio de Gran Conductancia Activados por Calcio/fisiología , Masculino , Canales de Potasio con Entrada de Voltaje/fisiología , Flujo Sanguíneo Regional/fisiología , Porcinos , Ultrasonografía
15.
Microcirculation ; 17(8): 600-7, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21044214

RESUMEN

This study was designed to elucidate the contribution of adenosine A(2A) and A(2B) receptors to coronary reactive hyperemia and downstream K(+) channels involved. Coronary blood flow was measured in open-chest anesthetized dogs. Adenosine dose-dependently increased coronary flow from 0.72 ± 0.1 to 2.6 ± 0.5 mL/minute/g under control conditions. Inhibition of A(2A) receptors with SCH58261 (1 µm) attenuated adenosine-induced dilation by ∼50%, while combined administration with the A(2B) receptor antagonist alloxazine (3 µm) produced no additional effect. SCH58261 significantly reduced reactive hyperemia in response to a transient 15 second occlusion; debt/repayment ratio decreased from 343 ± 63 to 232 ± 44%. Alloxazine alone attenuated adenosine-induced increases in coronary blood flow by ∼30% but failed to alter reactive hyperemia. A(2A) receptor agonist CGS21680 (10 µg bolus) increased coronary blood flow by 3.08 ± 0.31 mL/minute/g. This dilator response was attenuated to 0.76 ± 0.14 mL/minute/g by inhibition of K(V) channels with 4-aminopyridine (0.3mm) and to 0.11 ± 0.31 mL/minute/g by inhibition of K(ATP) channels with glibenclamide (3 mg/kg). Combined administration abolished vasodilation to CGS21680. These data indicate that A(2A) receptors contribute to coronary vasodilation in response to cardiac ischemia via activation of K(V) and K(ATP) channels.


Asunto(s)
Hiperemia/fisiopatología , Canales KATP/fisiología , Isquemia Miocárdica/fisiopatología , Canales de Potasio con Entrada de Voltaje/fisiología , Receptor de Adenosina A2A/fisiología , Receptor de Adenosina A2B/fisiología , 4-Aminopiridina/farmacología , Adenosina/administración & dosificación , Adenosina/análogos & derivados , Adenosina/farmacología , Adenosina/fisiología , Agonistas del Receptor de Adenosina A2/farmacología , Antagonistas del Receptor de Adenosina A2/farmacología , Animales , Circulación Coronaria/efectos de los fármacos , Circulación Coronaria/fisiología , Modelos Animales de Enfermedad , Perros , Flavinas/farmacología , Gliburida/farmacología , Canales KATP/antagonistas & inhibidores , Masculino , Fenetilaminas/farmacología , Bloqueadores de los Canales de Potasio/farmacología , Canales de Potasio con Entrada de Voltaje/antagonistas & inhibidores , Pirimidinas/farmacología , Triazoles/farmacología , Vasodilatación/efectos de los fármacos , Vasodilatación/fisiología
16.
JACC Basic Transl Sci ; 5(3): 267-278, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32215349

RESUMEN

Mild hypothermia (MH) and retroperfusion are 2 techniques proposed to reduce infarct size due to myocardial infarction. The authors evaluated the effects of focal MH combined with selective coronary venous autoretroperfusion (SARP) as an acute cardioprotective modality before percutaneous coronary intervention (PCI) in a swine model of left ventricular myocardial infarction. Significant reduction in infarct size with preservation of cardiac function and cardiomyocyte viability were achieved. The authors propose that SARP alone or in combination with MH may provide a clinically relevant percutaneous short-term option of cardiac support to high-risk patients undergoing PCI.

17.
Circ Cardiovasc Interv ; 11(1): e005333, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29311285

RESUMEN

BACKGROUND: Proper vessel sizing during endovascular interventions is crucial to avoid adverse procedural and clinical outcomes. LumenRECON (LR) is a novel, nonimaging, 0.035-inch wire-based technology that uses the physics-based principle of Ohm's law to provide a simple, real-time luminal size while also providing a platform for therapy delivery. This study evaluated the accuracy, reliability, and safety of the LR system in patients presenting for a femoropopliteal artery intervention. METHODS AND RESULTS: This multicenter, prospective pilot study of 24 patients presenting for peripheral intervention compared LR measurements of femoropopliteal artery size to angiographic visual estimation, duplex ultrasound, quantitative angiography, and intravascular ultrasound. The primary effectiveness and safety end point was comparison against core laboratory adjudicated intravascular ultrasound values and major adverse events, respectively. Additional preclinical studies were also performed in vitro and in vivo in swine to determine the accuracy of the LR guidewire system. No intra- or postprocedure device-related adverse events occurred. A balloon or stent was successfully delivered in 12 patients (50%) over the LR wire. Differences in repeatability between successive LR measurements was 2.5±0.40% (R2=0.96) with no significant bias. Differences in measurements of LR to other modalities were 0.5±1.7%, 5.0±1.8%, -1.5±2.0%, and 6.8±3.4% for intravascular ultrasound core laboratory, quantitative angiography, angiographic, and duplex ultrasound, respectively. CONCLUSIONS: This study demonstrates that through a physics-based principle, LR provides a real-time, safe, reproducible, and accurate vessel size of the femoropopliteal artery during intervention and can additionally serve as a conduit for therapy delivery over its wire-based platform.


Asunto(s)
Cateterismo Periférico/instrumentación , Procedimientos Endovasculares/instrumentación , Arteria Femoral/cirugía , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/cirugía , Arteria Poplítea/cirugía , Dispositivos de Acceso Vascular , Anciano , Angiografía , Animales , Toma de Decisiones Clínicas , Impedancia Eléctrica , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Modelos Animales , Selección de Paciente , Enfermedad Arterial Periférica/fisiopatología , Proyectos Piloto , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Sus scrofa , Ultrasonografía Doppler Dúplex , Ultrasonografía Intervencional , Estados Unidos
18.
Ann Biomed Eng ; 46(1): 186-196, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29086223

RESUMEN

Mortality during follow-up after acute Type B aortic dissection is substantial with aortic expansion observed in over 59% of the patients. Lumen pressure differential is considered a prime contributing factor for aortic dilation after propagation. The objective of the study was to evaluate the relationship between changes in vessel geometry with and without lumen pressure differential post propagation in an ex vivo porcine model with comparison with patient clinical data. A pulse duplicator system was utilized to propagate the dissection within descending thoracic porcine aortic vessels for set proximal (%circumference of the entry tear: 40%, axial length: 2 cm) and re-entry (50% of distal vessel circumference) tear geometry. Measurements of lumen pressure differential were made along with quantification of vessel geometry (n = 16). The magnitude of mean lumen pressure difference measured after propagation was low (~ 5 mmHg) with higher pressures measured in false lumen and as anticipated the pressure difference approached zero after the creation of distal re-entry tear. False lumen Dissection Ratio (FDR) defined as arc length of dissected wall divided by arc length of dissection flap, had mean value of 1.59 ± 0.01 at pressure of 120/80 mmHg post propagation with increasing values with increase in pulse pressure that was not rescued with the creation of distal re-entry tear (p < 0.01). An average FDR of 1.87 ± 0.27 was measured in patients with acute Type B dissection. Higher FDR value (FDR = 1 implies zero dissection) in the presence of distal re-entry tear demonstrates an acute change in vessel morphology in response to the dissection independent of local pressure changes challenges the re-apposition of the aortic wall.


Asunto(s)
Aneurisma de la Aorta Torácica/fisiopatología , Disección Aórtica/fisiopatología , Adulto , Anciano , Animales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Porcinos
19.
PLoS One ; 12(1): e0168886, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28045933

RESUMEN

Although the clinical range of interventions for coronary arteries is about 2 to 5 mm, the range of diameters of peripheral vasculature is significantly larger (about 10 mm for human iliac artery). When the vessel diameter is increased, the spacing between excitation electrodes on a conductance sizing device must also increase to accommodate the greater range of vessel diameters. The increase in the excitation electrodes distance, however, causes higher parallel conductance or current losses outside of artery lumen. We have previously shown that the conductance catheter/guidewire excitation electrode distances affects the measurement accuracy for the peripheral artery lumen sizing. Here, we propose a simple solution that varies the detection electrode distances to compensate for parallel conductance losses. Computational models were constructed to simulate the conductance guidewire with various electrodes spacing combinations over a range of peripheral artery lumen diameters and surrounding tissue electrical conductivities. The results demonstrate that the measurement accuracy may be significantly improved by increased detection spacing. Specifically, an optimally configured detection/excitation spacing (i.e., 5-5-5 or an equidistant electrode interval with a detection-to-excitation spacing ratio of 0.3) was shown to accurately predict the lumen diameter (i.e., -10% < error < 10%) over a broad range of peripheral artery dimensions (4 mm < diameter < 10 mm). The computational results were substantiated with both ex-vivo and in-vivo measurements of peripheral arteries. The present results support the accuracy of the conductance technique for measurement of peripheral reference vessel diameter.


Asunto(s)
Vasos Sanguíneos/anatomía & histología , Catéteres , Vasos Coronarios/anatomía & histología , Animales , Aterosclerosis , Cateterismo/instrumentación , Simulación por Computador , Conductividad Eléctrica , Electrodos , Diseño de Equipo , Humanos , Arteria Ilíaca , Masculino , Modelos Cardiovasculares , Modelos Teóricos , Enfermedad Arterial Periférica/terapia , Reproducibilidad de los Resultados , Porcinos
20.
Ann Biomed Eng ; 45(3): 592-603, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27510916

RESUMEN

The hemodynamic and geometric factors leading to propagation of acute Type B dissections are poorly understood. The objective is to elucidate whether geometric and hemodynamic parameters increase the predilection for aortic dissection propagation. A pulse duplicator set-up was used on porcine aorta with a single entry tear. Mean pressures of 100 and 180 mmHg were used, with pulse pressures ranging from 40 to 200 mmHg. The propagation for varying geometric conditions (%circumference of the entry tear: 15-65%, axial length: 0.5-3.2 cm) were tested for two flap thicknesses (1/3rd and 2/3rd of the thickness of vessel wall, respectively). To assess the effect of pulse and mean pressure on flap dynamics, the %true lumen (TL) cross-sectional area of the entry tear were compared. The % circumference for propagation of thin flap (47 ± 1%) was not significantly different (p = 0.14) from thick flap (44 ± 2%). On the contrary, the axial length of propagation for thin flap (2.57 ± 0.15 cm) was significantly different (p < 0.05) from the thick flap (1.56 ± 0.10 cm). TL compression was observed during systolic phase. For a fixed geometry of entry tear (%circumference = 39 ± 2%; axial length = 1.43 ± 0.13 cm), mean pressure did not have significant (p = 0.84) effect on flap movement. Increase in pulse pressure resulted in a significant change (p = 0.02) in %TL area (52 ± 4%). The energy acting on the false lumen immediately before propagation was calculated as 75 ± 9 J/m2 and was fairly uniform across different specimens. Pulse pressure had a significant effect on the flap movement in contrast to mean pressure. Hence, mitigation of pulse pressure and restriction of flap movement may be beneficial in patients with type B acute dissections.


Asunto(s)
Aorta Torácica/fisiopatología , Rotura de la Aorta/fisiopatología , Presión Sanguínea , Modelos Cardiovasculares , Pulso Arterial , Animales , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA