Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Artif Organs ; 41(7): E52-E65, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27935084

RESUMEN

With the growth and diversity of mechanical circulatory support (MCS) systems entering clinical use, a need exists for a robust mock circulation system capable of reliably emulating and reproducing physiologic as well as pathophysiologic states for use in MCS training and inter-device comparison. We report on the development of such a platform utilizing the SynCardia Total Artificial Heart and a modified Donovan Mock Circulation System, capable of being driven at normal and reduced output. With this platform, clinically relevant heart failure hemodynamics could be reliably reproduced as evidenced by elevated left atrial pressure (+112%), reduced aortic flow (-12.6%), blunted Starling-like behavior, and increased afterload sensitivity when compared with normal function. Similarly, pressure-volume relationships demonstrated enhanced sensitivity to afterload and decreased Starling-like behavior in the heart failure model. Lastly, the platform was configured to allow the easy addition of a left ventricular assist device (HeartMate II at 9600 RPM), which upon insertion resulted in improvement of hemodynamics. The present configuration has the potential to serve as a viable system for training and research, aimed at fostering safe and effective MCS device use.


Asunto(s)
Simulación por Computador , Insuficiencia Cardíaca/fisiopatología , Corazón Artificial , Corazón/fisiopatología , Hemodinámica , Modelos Cardiovasculares , Presión Atrial , Diseño de Equipo , Corazón Auxiliar , Humanos , Función Ventricular Izquierda
2.
Perfusion ; 31(4): 349-52, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26531760

RESUMEN

This case study reports the operative management of a 63-year-old male patient following implantation of the HeartMate II (HMII) left ventricular assist device (LVAD), with a non-compliant left ventricle (LV) and a reduced right ventricular (RV) end-diastolic volume. Intraoperatively, the patient had a thin, fragile LV wall with laminated clot; a ventricular septal defect was encountered during removal of the clot. Along with an aortic valve repair, the LV and the septum were reconstructed with multiple bovine pericardium patches, thus, moderately reducing the RV and LV stroke volume. A difference in cardiac output via a Swan-Ganz catheter (approximately 1.5 l/min) was observed as opposed to the HMII's estimated flow. The result was later replicated and verified ITALIC! in vitrovia the Donovan Mock Circulation System (DMCS), where about 2 l/min lower flow on the HMII system was observed. In conclusion, the HMII flow rate displayed can be inaccurate and should only be used for trending.


Asunto(s)
Defectos del Tabique Interventricular , Ventrículos Cardíacos , Corazón Auxiliar , Falla de Prótesis , Animales , Bovinos , Defectos del Tabique Interventricular/fisiopatología , Defectos del Tabique Interventricular/cirugía , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad
3.
Front Cardiovasc Med ; 10: 1098348, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36910539

RESUMEN

Aortic valve disorders are important considerations in advanced heart failure patients being evaluated for left ventricular assist devices (LVAD) and those on LVAD support. Aortic insufficiency (AI) can be present prior to LVAD implantation or develop de novo during LVAD support. It is usually a progressive disorder and can lead to impaired LVAD effectiveness and heart failure symptoms. Severe AI is associated with worsening hemodynamics, increased hospitalizations, and decreased survival in LVAD patients. Diagnosis is made with echocardiographic, device assessment, and/or catheterization studies. Standard echocardiographic criteria for AI are insufficient for accurate diagnosis of AI severity. Management of pre-existing AI includes aortic repair or replacement at the time of LVAD implant. Management of de novo AI on LVAD support is challenging with increased risks of repeat surgical intervention, and percutaneous techniques including transcatheter aortic valve replacement are assuming greater importance. In this manuscript, we provide a comprehensive approach to contemporary diagnosis and management of aortic valve disorders in the setting of LVAD therapy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA