1.
Catheter Cardiovasc Interv ; 101(5): 932-942, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36924015

RESUMEN

BACKGROUND: With expansion of transcatheter aortic valve implantation (TAVI) into younger patients, valve durability is critically important. AIMS: We aimed to evaluate long-term valve function and incidence of severe structural valve deterioration (SVD) among patients ≥ 10-years post-TAVI and with echocardiographic follow-up at least 5-years postprocedure. METHODS: Data on patients who underwent TAVI from 2007 to 2011 were obtained from the UK TAVI registry. Patients with paired echocardiograms postprocedure and ≥5-years post-TAVI were included. Severe SVD was determined according to European task force guidelines. RESULTS: 221 patients (79.4 ± 7.3 years; 53% male) were included with median echocardiographic follow-up 7.0 years (range 5-13 years). Follow-up exceeded 10 years in 43 patients (19.5%). Valve types were the supra-annular self-expanding CoreValve (SEV; n = 143, 67%), balloon-expandable SAPIEN/XT (BEV; n = 67, 31%), Portico (n = 4, 5%) and unknown (n = 7, 3%). There was no difference between postprocedure and follow-up peak gradient in the overall cohort (19.3 vs. 18.4 mmHg; p = NS) or in those with ≥10-years follow-up (21.1 vs. 21.1 mmHg; p = NS). Severe SVD occurred in 13 patients (5.9%; median 7.8-years post-TAVI). Three cases (23.1%) were due to regurgitation and 10 (76.9%) to stenosis. Valve-related reintervention/death occurred in 5 patients (2.3%). Severe SVD was more frequent with BEV than SEV (11.9% vs. 3.5%; p = 0.02), driven by a difference in patients treated with small valves (BEV 28.6% vs. SEV 3.0%; p < 0.01). CONCLUSIONS: Hemodynamic function of transcatheter heart valves remains stable up to more than 10 years post-TAVI. Severe SVD occurred in 5.9%, and valve-related death/reintervention in 2.3%. Severe SVD was more common with BEV than SEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros , Reino Unido , Diseño de Prótesis
3.
Postgrad Med J ; 92(1090): 450-4, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26896441

RESUMEN

BACKGROUND: The epidemiology of heart disease is changing, with rheumatic heart disease becoming less common but degenerative valve disorders, heart failure and atrial fibrillation (AF) increasing. OBJECTIVE: We sought to determine the prevalence of structural cardiac abnormalities in the apparently symptom-free adult population within our prospective echocardiography (echo) registry. METHODS: Our echo registry comprised echo studies and associated demographic and clinical data obtained prospectively from 362 consecutive asymptomatic subjects aged 50-74 years and without known heart disease referred between 2011 and 2012 from general practices in the South East of England. RESULTS: 221 echo abnormalities were detected in 178 (49%) subjects (46% men; mean (±SD) age 63.9±9.2 years; 98% Caucasian). A major abnormality was detected in seven subjects: four had a large secundum atrial septal defect, one had critical aortic stenosis, one severe mitral regurgitation and one features of hypertrophic cardiomyopathy. Twelve subjects had left ventricular systolic dysfunction with an ejection fraction (EF) <50% (of whom 10 had EF <40%). Four subjects had AF. Minor echo abnormalities were evident in the remaining 171 (47%) subjects. Abnormalities were commoner in patients with cardiovascular risk factors or a history of cardiac disease than in those without (53% vs 38%). In multivariate analyses stratified by gender, for women, increased age (F=33.3, p<0.001) and systolic blood pressure (F=9.2, p=0.003) were associated with abnormal echo findings; for men, increased age (F=12.0, p<0.001) and lower cholesterol (F=4.2, p=0.042) predicted an increase in abnormal findings on echo. CONCLUSIONS: Unrecognised cardiac abnormalities are very common in middle-aged men and women with no overt symptoms. Echo offers the potential to identify the need for early intervention and treatment to improve cardiovascular outcomes.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Ecocardiografía , Soplos Cardíacos/diagnóstico por imagen , Tamizaje Masivo , Sistema de Registros , Anciano , Enfermedades Cardiovasculares/epidemiología , Análisis Costo-Beneficio , Ecocardiografía/economía , Inglaterra/epidemiología , Femenino , Soplos Cardíacos/epidemiología , Humanos , Masculino , Tamizaje Masivo/economía , Tamizaje Masivo/métodos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Estudios Prospectivos , Factores de Riesgo
5.
Am J Cardiol ; 222: 23-28, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692400

RESUMEN

The Navitor transcatheter heart valve (THV) is the latest iteration of the Portico self-expanding valve system. Early prospective studies have shown promising outcomes, however, there is a lack of complementary 'real-world' data. This study aimed to assess early safety and efficacy outcomes of the Navitor THV using registry data from 6 high-volume United Kingdom transcatheter aortic valve replacement (TAVR) centers. Demographic, procedural, and in-hospital outcome data were retrieved from 6 United Kingdom centers. The primary safety end point was 30-day mortality. Primary efficacy end points were procedural success, mean aortic gradient, and ≥moderate paravalvular leak. Secondary end points included rates of new permanent pacemaker implantation, stroke, and vascular injury. A total of 574 patients (mean age 83.4 years; 54.5% female) underwent Navitor TAVR between January 2020 and May 2023. The 30-day mortality in this patient cohort was 1.6%. Procedural success was 98.1%, mean echo-derived gradient post-TAVR was 7.7 ± 4.8 mm Hg (95% confidence interval [CI] 7.2 to 8.3, p <0.001) and 5.1% of patients had ≥moderate paravalvular leak (sample proportion estimate [p̂] = 0.051, 95% CI [0.035, 0.073], p <0.001). New permanent pacemaker implantation to discharge was required in 11% (p̂ = 0.119, 95% CI 0.088 to 0.158, p <0.001), stroke occurred in 1.2% of patients (p̂ = 0.017, 95% CI 0.006 to 0.036, p <0.001) and significant vascular injury in 1.6% (p̂ = 0.014, 95% CI 0.005 to 0.032, p <0.001). In conclusion, early procedural outcomes with Navitor TAVR compare favorably to new-generation THVs. Procedural success was high with a low incidence of complications.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Reino Unido/epidemiología , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Anciano , Complicaciones Posoperatorias/epidemiología , Resultado del Tratamiento , Válvula Aórtica/cirugía
6.
Echo Res Pract ; 10(1): 12, 2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37528494

RESUMEN

Mitral interventions remain technically challenging owing to the anatomical complexity and heterogeneity of mitral pathologies. As such, multi-disciplinary pre-procedural planning assisted by advanced cardiac imaging is pivotal to successful outcomes. Modern imaging techniques offer accurate 3D renderings of cardiac anatomy; however, users are required to derive a spatial understanding of complex mitral pathologies from a 2D projection thus generating an 'imaging gap' which limits procedural planning. Physical mitral modelling using 3D printing has the potential to bridge this gap and is increasingly being employed in conjunction with other transformative technologies to assess feasibility of intervention, direct prosthesis choice and avoid complications. Such platforms have also shown value in training and patient education. Despite important limitations, the pace of innovation and synergistic integration with other technologies is likely to ensure that 3D printing assumes a central role in the journey towards delivering personalised care for patients undergoing mitral valve interventions.

7.
Br J Cardiol ; 28(1): 3, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35747485

RESUMEN

We describe a case of pneumopericardium following emergency pericardiocentesis in a patient with coronavirus disease 2019 (COVID-19).