1.
Phenomics ; 4(1): 72-80, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38605911

RESUMEN

This study aims to introduce the protocol for ultrasonic backscatter measurements of musculoskeletal properties based on a novel ultrasonic backscatter bone diagnostic (UBBD) instrument. Dual-energy X-ray absorptiometry (DXA) can be adopted to measure bone mineral density (BMD) in the hip, spine, legs and the whole body. The muscle and fat mass in the legs and the whole body can be also calculated by DXA body composition analysis. Based on the proposed protocol for backscatter measurements by UBBD, ultrasonic backscatter signals can be measured in vivo, deriving three backscatter parameters [apparent integral backscatter (AIB), backscatter signal peak amplitude (BSPA) and the corresponding arrival time (BSPT)]. AIB may provide important diagnostic information about bone properties. BSPA and BSPT may be important indicators of muscle and fat properties. The standardized backscatter measurement protocol of the UBBD instrument may have the potential to evaluate musculoskeletal characteristics, providing help for promoting the application of the backscatter technique in the clinical diagnosis of musculoskeletal disorders (MSDs), such as osteoporosis and muscular atrophy.

2.
Ultrasound Med Biol ; 49(1): 347-355, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36266143

RESUMEN

The study described here was aimed at investigating the feasibility of using the ultrasonic through-transmission technique to estimate human musculoskeletal and fat properties. Five hundred eighty-two volunteers were assessed by dual-energy X-ray absorptiometry (DXA) and ultrasonic transmission techniques. Bone mineral density (BMD), muscle and fat mass were measured for both legs and the whole body. Hip BMD and spine BMD were also measured. Ultrasonic transmission measurements were performed on the heel, and the measured parameters were broadband ultrasound attenuation (BUA), speed of sound (SOS), ultrasonic stiffness index (SI), T-score and Z-score, which were significantly correlated with all measured BMDs. The optimal correlation was observed between SI and left-leg BMD (p < 0.001) before and after adjustment for age, sex and body mass index (BMI). The linear and partial correlation analyses revealed that BUA and SOS were closely associated with muscle and fat mass, respectively. Multiple regressions revealed that muscle and fat mass significantly contributed to the prediction of transmission parameters, explaining up to 17.83% (p < 0.001) variance independently of BMD. The results suggest that the ultrasonic through-transmission technique could help in the clinical diagnosis of skeletal and muscular system diseases.


Asunto(s)
Calcáneo , Sistema Musculoesquelético , Humanos , Ultrasonido , Ultrasonografía , Absorciometría de Fotón/métodos , Densidad Ósea/fisiología , Calcáneo/diagnóstico por imagen
3.
Front Oncol ; 12: 799207, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35372054

RESUMEN

Background: The accurate definition of gross tumor volume (GTV) of esophageal squamous cell carcinoma (ESCC) can promote precise irradiation field determination, and further achieve the radiotherapy curative effect. This retrospective study is intended to assess the applicability of leveraging deep learning-based method to automatically define the GTV from 3D 18F-FDG PET/CT images of patients diagnosed with ESCC. Methods: We perform experiments on a clinical cohort with 164 18F-FDG PET/CT scans. The state-of-the-art esophageal GTV segmentation deep neural net is first employed to delineate the lesion area on PET/CT images. Afterwards, we propose a novel equivalent truncated elliptical cone integral method (ETECIM) to estimate the GTV value. Indexes of Dice similarity coefficient (DSC), Hausdorff distance (HD), and mean surface distance (MSD) are used to evaluate the segmentation performance. Conformity index (CI), degree of inclusion (DI), and motion vector (MV) are used to assess the differences between predicted and ground truth tumors. Statistical differences in the GTV, DI, and position are also determined. Results: We perform 4-fold cross-validation for evaluation, reporting the values of DSC, HD, and MSD as 0.72 ± 0.02, 11.87 ± 4.20 mm, and 2.43 ± 0.60 mm (mean ± standard deviation), respectively. Pearson correlations (R2) achieve 0.8434, 0.8004, 0.9239, and 0.7119 for each fold cross-validation, and there is no significant difference (t = 1.193, p = 0.235) between the predicted and ground truth GTVs. For DI, a significant difference is found (t = -2.263, p = 0.009). For position assessment, there is no significant difference (left-right in x direction: t = 0.102, p = 0.919, anterior-posterior in y direction: t = 0.221, p = 0.826, and cranial-caudal in z direction: t = 0.569, p = 0.570) between the predicted and ground truth GTVs. The median of CI is 0.63, and the gotten MV is small. Conclusions: The predicted tumors correspond well with the manual ground truth. The proposed GTV estimation approach ETECIM is more precise than the most commonly used voxel volume summation method. The ground truth GTVs can be solved out due to the good linear correlation with the predicted results. Deep learning-based method shows its promising in GTV definition and clinical radiotherapy application.

4.
Front Physiol ; 13: 976254, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36003640

RESUMEN

Background: Electrocardiogram (ECG) and carotid ultrasound (CUS) are important tools for the diagnosis and prediction of cardiovascular disease (CVD). This study aimed to investigate the associations between ECG and CUS parameters and explore the feasibility of assessing carotid health with ECG. Methods: This cross-sectional cohort study enrolled 319 healthy Chinese subjects. Standard 12-lead ECG parameters (including the ST-segment amplitude [STA]), CUS parameters (intima-media thickness [IMT] and blood flow resistance index [RI]), and CVD risk factors (including sex, age, and systolic blood pressure [SBP]) were collected for analysis. Participants were divided into the high-level RI group (average RI ≥ 0.76, n = 171) and the normal RI group (average RI < 0.76, n = 148). Linear and stepwise multivariable regression models were performed to explore the associations between ECG and CUS parameters. Results: Statistically significant differences in sex, age, SBP, STA and other ECG parameters were observed in the normal and the high-level RI group. The STA in lead V3 yielded stronger significant correlations (r = 0.27-0.42, p < 0.001) with RI than STA in other leads, while ECG parameters yielded weak correlations with IMT (|r| ≤ 0.20, p < 0.05). STA in lead V2 or V3, sex, age, and SBP had independent contributions (p < 0.01) to predicting RI in the stepwise multivariable models, although the models for IMT had only CVD risk factors (age, body mass index, and triglyceride) as independent variables. The prediction model for RI in the left proximal common carotid artery (CCA) had higher adjusted R2 (adjusted R2 = 0.31) than the model for RI in the left middle CCA (adjusted R2 = 0.29) and the model for RI in the right proximal CCA (adjusted R2 = 0.20). Conclusion: In a cohort of healthy Chinese individuals, the STA was associated with the RI of CCA, which indicated that ECG could be utilized to assess carotid health. The utilization of ECG might contribute to a rapid screening of carotid health with convenient operations.

5.
Ultrasound Med Biol ; 47(8): 2404-2415, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34052063

RESUMEN

This study aims to investigate the feasibility of quantitative ultrasonic backscatter in evaluating human cortical and trabecular bone densities in vivo based on a head-down-tilt bed rest study, with 36 participants tested through 90 d of bed rest and 180 d of recovery. Backscatter measurements were performed using an ultrasonic backscatter bone diagnostic instrument. Backscatter parameters were calculated with a dynamic signal-of-interest method, which was proposed to ensure the same ultrasonic interrogated volume in cortical and trabecular bones. The backscatter parameters exhibited significant correlations with site-matched bone densities provided by high-resolution peripheral quantitative computed tomography (0.33 < |R| < 0.72, p < 0.05). Some bone densities and backscatter parameters exhibited significant changes after the 90-d bed rest. The proposed method can be used to characterize bone densities, and the portable ultrasonic backscatter bone diagnostic device might be used to non-invasively reveal mean bone loss (across a group of people) after long-term bed rest and microgravity conditions of spaceflight missions.


Asunto(s)
Densidad Ósea , Hueso Esponjoso/diagnóstico por imagen , Hueso Cortical/diagnóstico por imagen , Dispersión de Radiación , Ondas Ultrasónicas , Adulto , Reposo en Cama , Inclinación de Cabeza , Humanos , Masculino
SELECCIÓN DE REFERENCIAS