Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Endovasc Ther ; 30(3): 449-460, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35297713

RESUMEN

PURPOSE: The purpose of the study was to provide a consensus definition of the infrarenal sealing zone and develop an algorithm to determine when and if adjunctive procedure(s) or reintervention should be considered in managing patients undergoing endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm (AAA). METHODS: A European Advisory Board (AB), made up of 11 vascular surgeons with expertise in EVAR for AAA, was assembled to share their opinion regarding the definition of preoperative and postoperative infrarenal sealing zone. Information on their current clinical practice and level of agreement on proposed reintervention paths was used to develop an algorithm. The process included 2 virtual meetings and 2 rounds of online surveys completed by the AB (Delphi method). Consensus was defined as reached when ≥ 8 of 11 (73%) respondents agreed or were neutral. RESULTS: The AB reached complete consensus on definitions and measurement of the pre-EVAR target anticipated sealing zone (TASZ) and the post-EVAR real achieved sealing zone (RASZ), namely, the shortest length between the proximal and distal reference points as defined by the AB, in case of patients with challenging anatomies. Also, agreement was achieved on a list of 4 anatomic parameters and 3 prosthesis-/procedure-related parameters, considered to have the most significant impact on preoperative and postoperative sealing zones. Furthermore, the agreement was reached that in the presence of visible neck-related complications, both adjunctive procedure(s) and reintervention should be contemplated (100% consensus). In addition, adjunctive procedure(s) or reintervention can be considered in the following cases (% consensus): insufficient sealing zone on completion imaging (91%) or on the first postoperative computed tomography (CT) scan (91%), suboptimal sealing zone on completion imaging (73%) or postoperative CT scan (82%), and negative evolution of the actual sealing zone over time (91%), even in the absence of visible complications. CONCLUSIONS: AB members agreed on definitions of the pre- and post-EVAR infrarenal sealing zone, as well as factors of influence. Furthermore, a clinical decision algorithm was proposed to determine the timing and necessity of adjunctive procedure(s) and reinterventions.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Reparación Endovascular de Aneurismas , Técnica Delphi , Consenso , Testimonio de Experto , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Factores de Riesgo , Estudios Retrospectivos , Prótesis Vascular
2.
Ann Surg ; 274(6): e1030-e1037, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31851006

RESUMEN

BACKGROUND: SSMD are used to enhance transparency, improve quality and facilitate patient choice. The use of SSMD is controversial, but patients' views on such data are largely unknown. OBJECTIVES: The aim of this study was therefore to explore the views of patients and to identify their priorities for outcome reporting in vascular surgery. METHODS: A prospective questionnaire study of 165 patients receiving care in a single academic vascular unit was performed. Data on patients' current understanding and use of SSMD, together with future priorities were collected. RESULTS: Of the 165 patients 80% were unaware of SSMD. 72% thought they should be made aware of the data, although 63% thought they were likely to misinterpret the results. The majority recognized the utility of SSMD to inform treatment (60%) and surgeon (53%) choice. The majority prioritize the patient-surgeon relationship (90%) and past experiences of care (71%) when making treatment decisions. A significant majority (66% vs 49%; P < 0.005) would favour hospital-level to surgeon-level data. The main patient priorities for future outcome reporting were waiting list length (56%), the quality of hospital facilities (55%), and patient satisfaction (54%). CONCLUSIONS: The aims of SSMD reporting are not currently being met, and both patients and healthcare professionals have shared concerns over the nature and usefulness of the data. Patients express a preference for hospital-level outcomes and prioritize the experience of receiving care over outcomes when making treatment decisions. Future outcome reporting should include patient-directed hospital-level metrics that are readily accessible and understood by all.


Asunto(s)
Medición de Resultados Informados por el Paciente , Encuestas y Cuestionarios , Procedimientos Quirúrgicos Vasculares , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Psicometría , Reino Unido
3.
J Vasc Surg ; 69(5): 1482-1489, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30527939

RESUMEN

OBJECTIVE: Video motion analysis (VMA) uses fluoroscopic sequences to derive information on catheter and guidewire movement and is able to calculate two-dimensional catheter tip path length (PL) on the basis of frame-by-frame pixel coordinates. The objective of this study was to evaluate the effect of anatomic complexity on the efficiency of completion of defined stages of simulated carotid artery stenting as measured by VMA. METHODS: Twenty interventionists each performed a standardized easy, medium, and difficult carotid artery stenting case in random order on an ANGIO Mentor (Simbionix, Airport City, Israel) simulator. Videos of all procedures were analyzed using VMA software, and performance was expressed in terms of two-dimensional guidewire tip trajectory distance (PL). Comparisons of PL were used to identify differences in cannulation performance of the participants between the three cases of varying difficulty. The procedure was subdivided into four procedural phases: arch navigation, common carotid artery (CCA) cannulation, external carotid manipulation, and carotid lesion crossing. Comparisons of PL were used to identify differences in performance between the three cases of varying difficulty for each of the procedural phases. RESULTS: There were significant differences in PL in relation to anatomic complexity, with a stepwise increase in PL from easy to difficult cases: easy, median of 5000 pixels (interquartile range, 4075-5403 pixels); intermediate, 9059 (5974-14,553) pixels; difficult, 17,373 (11,495-26,594) pixels (P < .001). Similarly, during CCA cannulation, there was a stepwise increase in PL from easy to difficult cases: easy, 749 (603-1403) pixels; intermediate, 3274 (1544-8142) pixels; difficult, 8845 (5954-15,768) pixels (P < .001). There were no observed differences across the groups of anatomic difficulty for the phases of arch navigation, external carotid manipulation, and carotid lesion crossing. CONCLUSIONS: Increasing anatomic complexity leads to significant increases in PL of endovascular tools, in particular during CCA cannulation. This increase in tool movement may have a bearing on clinical outcome.


Asunto(s)
Angioplastia/educación , Estenosis Carotídea/terapia , Cateterismo Periférico , Competencia Clínica , Educación de Postgrado en Medicina/métodos , Destreza Motora , Entrenamiento Simulado , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia/instrumentación , Estenosis Carotídea/diagnóstico por imagen , Cateterismo Periférico/instrumentación , Femenino , Humanos , Masculino , Estudios Prospectivos , Distribución Aleatoria , Índice de Severidad de la Enfermedad , Stents , Análisis y Desempeño de Tareas , Dispositivos de Acceso Vascular , Grabación en Video
5.
Eur J Vasc Endovasc Surg ; 65(5): 719, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36894125
6.
Eur J Vasc Endovasc Surg ; 54(6): 778-786, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29150228

RESUMEN

BACKGROUND: System factors contributing to preventable harm in vascular patients have not been previously reported in detail. The aim of this exploratory mixed-methods study was to describe vascular surgeons' perceptions of factors contributing to adverse events (AEs) in arterial surgery. A secondary aim was to report recommendations to improve patient safety. METHODS: Vascular consultants/registrars working in the British National Health Service were questioned about the causes of preventable AEs through survey and semi-structured interview (response rates 77% and 83%, respectively). Survey respondents considered a recent AE, indicating on a 5 point Likert scale the extent to which various factors from a validated framework contributed toward the incident. Semi-structured interviews were conducted to obtain detailed accounts of contributory factors, and to elicit recommendations to improve safety. RESULTS: Seventy-seven surgeons completed the survey on 77 separate AEs occurring during open surgery (n = 41) and in endovascular procedures (n = 36). Ten interviewees described 15 AEs. The causes of AEs were multifactorial (median number of factors/AE = 5, IQR 3-9, range 0-25). Factors frequently reported by survey respondents were communication failures (36.4%; n = 28/77); inadequate staffing levels/skill mix (32.5%; n = 25/77); lack of knowledge/skill (37.3%; n = 28/75). Themes emerging from interviews were team factors (communication failure, lack of team continuity, lack of clarity over roles/responsibilities); work environment factors (poor staffing levels, equipment problems, distractions); inadequate training/supervision. Knowledge/skill (p = .034) and competence (p = .018) appeared to be more prominent in causing AEs in open procedures compared with endovascular procedures; organisational structure was more frequently implicated in AEs occurring in endovascular procedures (p = .017). To improve safety, interviewees proposed team training programmes (5/10 interviewees); additional protocols/checklists (4/10); improved escalation procedures (3/10). CONCLUSION: Vascular surgeons believe that AEs in arterial operations are caused by multiple, modifiable system factors. Larger studies are needed to establish the relative importance of these factors and to determine strategies that can effectively address system failures.


Asunto(s)
Actitud del Personal de Salud , Complicaciones Intraoperatorias/etiología , Complicaciones Intraoperatorias/prevención & control , Errores Médicos/prevención & control , Procedimientos Quirúrgicos Vasculares/efectos adversos , Competencia Clínica , Comunicación , Humanos , Complicaciones Intraoperatorias/diagnóstico , Factores de Riesgo , Encuestas y Cuestionarios , Reino Unido , Carga de Trabajo
7.
Eur Heart J ; 37(42): 3213-3221, 2016 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-27371719

RESUMEN

AIMS: The AARDVARK (Aortic Aneurysmal Regression of Dilation: Value of ACE-Inhibition on RisK) trial investigated whether ACE-inhibition reduces small abdominal aortic aneurysms (AAA) growth rate, independent of blood pressure (BP) lowering. METHODS AND RESULTS: A three-arm, multi-centre, single-blind, and randomized controlled trial (ISRCTN51383267) was conducted in 14 hospitals in England. Subjects aged ≥55 years with AAA diameter 3.0-5.4 cm were randomized 1:1:1 to receive perindopril arginine 10 mg, or amlodipine 5 mg, or placebo and followed 3-6 monthly over 2 years. The primary outcome was aneurysm growth rate (based on external antero-posterior ultrasound measurements in the longitudinal plane), determined by multi-level modelling to provide maximum likelihood estimates. Two hundred and twenty-four subjects were randomized (2011-2013) to placebo (n = 79), perindopril (n = 73), or amlodipine (n = 72). Mean (SD) changes in mid-trial systolic BP (12 months) were 0.5 (14.3) mmHg, P = 0.78 compared with baseline, -9.5 (13.1) mmHg (P < 0.001), and -6.7 (12.0) mmHg (P < 0.001), respectively. No significant differences in the modelled annual growth rates were apparent [1.68 mm (SE 0.2), 1.77 mm (0.2), and 1.81 mm (0.2), respectively]. The estimated difference in annual growth between the perindopril and placebo groups was 0.08 mm (CI -0.50, 0.65). Similar numbers of AAAs in each group reached 5.5 cm diameter and/or underwent elective surgery: 11 receiving placebo, 10 perindopril, and 11 amlodipine. CONCLUSION: Small AAA growth rates were lower than anticipated, but there was no significant impact of perindopril compared with placebo or placebo and amlodipine, combined despite more effective BP lowering.


Asunto(s)
Aneurisma de la Aorta Abdominal , Inhibidores de la Enzima Convertidora de Angiotensina , Antihipertensivos , Presión Sanguínea , Método Doble Ciego , Inglaterra , Humanos , Hipertensión , Funciones de Verosimilitud , Persona de Mediana Edad , Método Simple Ciego
8.
Ann Surg ; 264(5): 703-709, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27429036

RESUMEN

OBJECTIVE: To assess the effect of patient-specific virtual reality rehearsal (PsR) before endovascular infrarenal aneurysm repair (EVAR) on technical performance and procedural errors. BACKGROUND: Endovascular procedures, including EVAR, are executed in a complex multidisciplinary environment, often treating high-risk patients. Consequently, this may lead to patient harm and procedural inefficiency. PsR enables the endovascular team to evaluate and practice the case in a virtual environment before treating the real patient. METHODS: A multicenter, prospective, randomized controlled trial recruited 100 patients with a nonruptured infrarenal aortic or iliac aneurysm between September 2012 and June 2014. Cases were randomized to preoperative PsR or standard care (no PsR). Primary outcome measures were errors during the real procedure and technical operative metrics (total endovascular and fluoroscopy time, contrast volume, number of angiograms, and radiation dose). RESULTS: There was a 26% [95% confidence interval (CI) 9%-40%, P = 0.004) reduction in minor errors, a 76% (95% CI 30%-92%, P = 0.009) reduction in major errors, and a 27% (95% CI 8.2%-42%, P = 0.007) reduction in errors causing procedural delay in the PsR group. The number of angiograms performed to visualize proximal and distal landing zones was 23% (95% CI 8%-36%, P = 0.005) and 21% (95% CI 7%-32%, P = 0.004) lower in the PsR group. CONCLUSIONS: PsR before EVAR can be used in different hospital settings by teams with various EVAR experience. It reduces perioperative errors and the number of angiograms required to deploy the stent graft, thereby reducing delays. Ultimately, it may improve patient safety and procedural efficiency.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/efectos adversos , Aneurisma Ilíaco/cirugía , Complicaciones Intraoperatorias/prevención & control , Modelación Específica para el Paciente , Complicaciones Posoperatorias/prevención & control , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Seguridad del Paciente , Práctica Psicológica , Estudios Prospectivos , Resultado del Tratamiento
9.
J Vasc Surg ; 64(5): 1422-1432, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26386511

RESUMEN

OBJECTIVE: Conventional catheter manipulation in the arch and supra-aortic trunks carries a risk of cerebral embolization. This study proposes a platform for detailed quantitative analysis of contact forces (CF) exerted on the vasculature, in order to investigate the potential advantages of robotic navigation. METHODS: An anthropomorphic phantom representing a type I bovine arch was mounted and coupled onto a force/torque sensor. Three-axis force readings provided an average root-mean-square modulus, indicating the total forces exerted on the phantom. Each of the left subclavian, left common carotid, and right common carotid arteries was cannulated within a simulated endovascular suite with conventional (n = 42) vs robotic techniques (n = 30) by two operator groups: experts and novices. The procedure path was divided into three phases, and performance metrics corresponding to mean and maximum forces, force impact over time, standard deviation of forces, and number of significant catheter contacts with the arterial wall were extracted. RESULTS: Overall, median CF were reduced from 1.20 N (interquartile range [IQR], 0.98-1.56 N) to 0.31 N (IQR, 0.26-0.40 N; P < .001) for the right common carotid artery; 1.59 N (IQR, 1.11-1.85 N) to 0.33 N (IQR, 0.29-0.43 N; P < .001) for the left common carotid artery; and 0.84 N (IQR, 0.47-1.08 N) to 0.10 N (IQR, 0.07-0.17 N; P < .001) for the left subclavian artery. Robotic navigation resulted in significant reductions for the mean and maximum forces for each procedural phase. Significant improvements were also seen in other metrics, particularly at the target vessel ostium and for the more anatomically challenging procedural phases. Force reductions using robotic technology were evident for both novice and expert groups. CONCLUSIONS: Robotic navigation can potentially reduce CF and catheter-tissue contact points in an in vitro model, by enhancing catheter stability and control during endovascular manipulation.


Asunto(s)
Aorta Torácica/cirugía , Cateterismo Periférico/instrumentación , Embolia/prevención & control , Procedimientos Endovasculares/instrumentación , Procedimientos Quirúrgicos Robotizados/instrumentación , Accidente Cerebrovascular/prevención & control , Dispositivos de Acceso Vascular , Aorta Torácica/anomalías , Aorta Torácica/fisiopatología , Cateterismo Periférico/efectos adversos , Competencia Clínica , Embolia/etiología , Embolia/fisiopatología , Procedimientos Endovasculares/efectos adversos , Diseño de Equipo , Humanos , Modelos Anatómicos , Destreza Motora , Factores de Riesgo , Procedimientos Quirúrgicos Robotizados/efectos adversos , Estrés Mecánico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/fisiopatología , Análisis y Desempeño de Tareas , Factores de Tiempo , Torque
11.
12.
Ann Vasc Surg ; 29(4): 841.e1-3, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25744231

RESUMEN

We report a case of leiomyosarcoma of the thoracic aorta in a 49-year-old male patient with history of hypertrophic cardiomyopathy. The only presenting symptom was back pain localized under the left scapula with the frequency and severity of the pain increasing with time. Imaging studies detected the presence of an aortic tumor. The tumor was excised en bloc, and an interposition graft was implanted. The histology showed a fully excised grade 3 leiomyosarcoma. This article discusses features of this rare condition.


Asunto(s)
Aorta Torácica/patología , Cardiomiopatía Hipertrófica/complicaciones , Leiomiosarcoma/patología , Neoplasias Vasculares/patología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aortografía/métodos , Dolor de Espalda/etiología , Implantación de Prótesis Vascular , Cardiomiopatía Hipertrófica/diagnóstico , Humanos , Leiomiosarcoma/complicaciones , Leiomiosarcoma/cirugía , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Neoplasias Vasculares/complicaciones , Neoplasias Vasculares/cirugía
13.
J Vasc Surg ; 59(3): 615-22, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24342068

RESUMEN

OBJECTIVE: Fenestrated stent grafting has become increasingly popular as a means to manage complex aortic pathology, including juxta- and pararenal aneurysms. The design of a recently developed custom-made fenestrated stent graft, in theory, confers advantages when managing anatomically challenging aortic morphology. This study evaluated its feasibility in anatomically challenging scenarios. METHODS: Over a 12-month period, 20 patients received fenestrated stent grafts. Among those, 13 patients with juxtarenal or type IV thoracoabdominal aortic aneurysms underwent endovascular repair with the novel fenestrated stent graft at a single UK institution. Data on aneurysm morphology and immediate and short-term results were collected prospectively. RESULTS: The mean aneurysmal sac size was 7.3 cm (range, 5.5-10.0 cm). The mean infrarenal neck length was 4.4 mm (range, 0-9 mm), and in three cases was lined by a pre-existing infrarenal stent graft. Nine cases had an infrarenal neck angulation of 60(°) or more in either the anteroposterior or coronal planes. Five cases had ≥50% thrombus at the proximal landing zone. A total of 35 target vessels were cannulated, of which six right renal and four left renal arteries were angulated ≥120(°). Two-thirds of cannulated celiac trunks were angulated ≥120(°), and one cannulated superior mesenteric artery was angulated ≥ 140(°). Seven of the cannulated targets were stenosed more than 60%. One patient had two right renal arteries arising 3 mm from each other. Four right and four left common iliac arteries were angulated ≥90(°) in relation to the infrarenal aorta. Technical success was 100%. Median time from date of procedure to most recent follow-up with computed tomography scanning was 33 weeks. There was no type I or III endoleak. One type II endoleak was observed at the time of most recent computed tomography scanning and treated expectantly. There was a single incident of left renal artery occlusion. One patient required repair of a brachial artery, fasciotomies, and temporary haemofiltration. One patient died from ischemic heart disease 77 weeks after the procedure. CONCLUSIONS: The use of the novel fenestrated stent graft system in patients with hostile aortic aneurysmal morphology is feasible with acceptable short-term outcomes.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Diseño de Prótesis , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Endofuga/terapia , Procedimientos Endovasculares/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Londres , Masculino , Estudios Prospectivos , Obstrucción de la Arteria Renal/etiología , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
14.
J Vasc Surg ; 60(2): 330-6, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24767711

RESUMEN

OBJECTIVE: Late thoracic aneurysms develop in 5% to 12% of patients having undergone open repair for coarctation of the aorta (CoA). We report our early results for thoracic endovascular aortic repair for pseudoaneurysms after CoA repair. METHODS: From 2008 to 2013, data regarding demographics, aneurysm morphology, procedure, and follow-up were collected prospectively on all patients treated for pseudoaneurysms after CoA repair. Retrospective analysis of identified patients was then performed. RESULTS: Thirteen patients (six men, seven women) were treated. Patients were a median age, 45 years (interquartile range (IQR), 39-56; range, 27-66 years, and the median time after CoA repair to aneurysm treatment was 34 years (IQR, 24-40 years). All patients had saccular pseudoaneurysms of the aortic arch, with a median aneurysm size of 4.1 cm (IQR, 3.4-5.1 cm). The left subclavian artery (LSCA) was involved in 10 patients and was occluded at presentation in three. Four patients had concurrent LSCA revascularization with carotid-subclavian bypass, one had aortic arch hybrid repair, and the LSCA was intentionally covered in two patients. Patients underwent thoracic endovascular aortic repair using the conformable TAG (6 of 13; W. L. Gore & Associates, Flagstaff, Ariz), Valiant device (4 of 13; Medtronic, Minneapolis, Minn), and a custom-made Relay endograft with LSCA scallop (4 of 13; Bolton Medical, Barcelona, Spain). Technical success was 100%, with satisfactory deployment of the stent grafts in all patients. There was no 30-day mortality, stroke, or paraplegia. Median follow-up was 15 months (IQR, 9-19 months; range, 1-67 months). Two type II endoleaks from an intercostal artery were managed conservatively, and one type Ib endoleak was treated successfully with distal stent extension. CONCLUSIONS: In this cohort, new-generation stent grafts have good early clinical and radiologic outcomes, avoiding the need for redo open surgery. Management of the LSCA can be tailored to individual patients with new stent graft technology. Long-term follow-up of these patients is crucial to understanding whether endovascular management of this cohort is acceptable.


Asunto(s)
Aneurisma Falso/cirugía , Aneurisma de la Aorta Torácica/cirugía , Coartación Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Adulto , Aneurisma Falso/diagnóstico , Aneurisma Falso/etiología , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/etiología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Endofuga/terapia , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
J Vasc Surg ; 60(6): 1499-506, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25264365

RESUMEN

BACKGROUND: The suitability of the proximal landing zone remains one of the main limitations to thoracic endovascular aortic repair (TEVAR). The advent of custom-made scalloped stent grafts widens the endovascular options for patients with challenging anatomy. The objective of this study was to present our early and midterm results of custom-made scalloped thoracic stent grafts. METHODS: Prospectively acquired data relating to patient demographics, procedure details, clinical outcome, and complications were analyzed. In addition, we analyzed preoperative and postoperative computed tomography scans to evaluate aneurysm morphology, graft placement, side-vessel patency, and endoleaks. RESULTS: Twenty-one patients with a median age of 71 years (range, 35-81 years) underwent custom-made scalloped TEVAR, eight of whom had a concomitant hybrid repair. Procedural success was achieved in all cases. Proximal seal was achieved in all cases, with no type I endoleaks. There were no cases of retrograde dissection and no conversions to open repair. The median follow-up period was 36 weeks (range, 3-183 weeks). Two patients died in the hospital. Three patients suffered a stroke. Three patients had a type II endoleak, one of whom had significant sac enlargement requiring reintervention. One patient had a type III endoleak requiring reintervention. There were no cases of graft migration. CONCLUSIONS: Our midterm results show that custom-made scalloped TEVAR is an acceptable treatment of thoracic aortic aneurysms with a short proximal landing zone. Longer term outcome data are required to establish wider use of scalloped thoracic endografts.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Grado de Desobstrucción Vascular
16.
J Vasc Interv Radiol ; 25(12): 1841-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25000827

RESUMEN

PURPOSE: To provide a technical description of robot-assisted uterine artery embolization and to investigate the safety and feasibility of the Magellan (Hansen Medical, Mountain View, California, USA) robotic catheter in this complex arterial bed. MATERIALS AND METHODS: Five women (mean age, 48.8 y) underwent robot-assisted bilateral uterine artery embolization over a 10-month period using the Magellan robotic catheter. Demographic, clinicopathologic, and endovascular performance metric data (fluoroscopy and cannulation times) were recorded as well as short-term outcomes. RESULTS: Robotic cannulation of bilateral internal iliac and uterine arteries was successful in all cases. Median right and left internal iliac artery cannulation and total fluoroscopy times were 3 minutes (interquartile range [IQR], 1.5-4 min), 2 minutes (IQR, 1.5-4 min), and 11 minutes (IQR, 9.5-14 min). Median right and left uterine artery cannulation times were both 11 minutes (IQR, 6.5-15 min and 8-12 min, respectively). Technical success was 100%. All patients were discharged on postoperative day 1, and there were no major or access site complications. At 6 months after the procedure, all patients reported significant improvement of symptoms, with a median increase in health-related quality-of-life score of 58% (48.5%-61.75%). CONCLUSIONS: The use of the new-generation Magellan system in uterine artery embolization is feasible and appears to be safe. The additional navigational capability and added maneuverability of the NorthStar catheter (Hansen Medical, Mountain View, California) may facilitate selective catheterization of small iliac artery divisions and may be useful in any procedure where complex arterial selection is needed.


Asunto(s)
Menorragia/cirugía , Robótica/instrumentación , Embolización de la Arteria Uterina/instrumentación , Salud de la Mujer , Adulto , Catéteres , Diseño de Equipo , Estudios de Factibilidad , Femenino , Fluoroscopía/métodos , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Robótica/métodos , Resultado del Tratamiento , Embolización de la Arteria Uterina/efectos adversos , Embolización de la Arteria Uterina/métodos
17.
J Ultrasound ; 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39292370

RESUMEN

We report a case of a 67-year-old woman suffering from intermittent claudication secondary to severe popliteal stenosis due to compression by a popliteal ganglion cyst extending into the adventitia of the popliteal artery. After declining vein bypass grafting, this patient was successfully treated using ultrasound-guided aspiration of the cyst, which restored normal flow to the popliteal artery. Whilst aspiration of Baker's cysts causing claudication has been attempted before, this represents the first reported case of successful recanalization of the popliteal artery by ganglion cyst aspiration and further supports an important possible aetiology and treatment for cystic adventitial disease.

18.
BJS Open ; 8(5)2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39270744

RESUMEN

BACKGROUND: A surgeon experiences elevated stress levels when operating. Acute stress is linked to cognitive overload, worsening surgical performance. Chronic stress poses a significant risk to a surgeon's health. Identifying intraoperative stress may allow for preventative strategies that reduce surgeons' stress and subsequently improve patient outcomes. The aim of this study was to assess the feasibility of using heart rate variability as a marker of stress during vascular surgery. METHODS: A total of 11 senior surgeons were evaluated performing three different vascular surgery procedures. Heart rate variability metrics (low-frequency to high-frequency ratio and standard deviation of the normal-normal interval) were determined from single-lead ECG traces at predetermined procedural performance points. State-Trait Anxiety Inventory-6, a validated stress tool, was used to assess surgeon-reported stress. Subjective reports of procedural difficulty were also collected. One-way ANOVA compared heart rate variability at key performance points with baseline. Pearson's coefficient assessed correlation between heart rate variability and subjective stress. RESULTS: Data were collected for six carotid endarterectomies, six open abdominal aortic aneurysm repairs, and five lower limb bypasses. Heart rate variability metrics indicating markedly greater stress were observed at key performance points across all procedures. Peaks in stress were consistent across different surgeons performing the same procedure. A significant correlation was observed between heart rate variability metrics and subjective State-Trait Anxiety Inventory-6 stress reports (r = 0.768, P =<0.001). The most difficult procedural steps reported corresponded with heart rate variability metrics displaying the greatest stress. CONCLUSION: Heart rate variability may be a viable approach to assess intraoperative stress and cognitive load during vascular surgery and could be used to evaluate whether a theatre intervention (for example timeout) could reduce stress in areas of surgical difficulty.


Asunto(s)
Frecuencia Cardíaca , Estrés Laboral , Cirujanos , Procedimientos Quirúrgicos Vasculares , Humanos , Frecuencia Cardíaca/fisiología , Cirujanos/psicología , Procedimientos Quirúrgicos Vasculares/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Electrocardiografía , Estrés Psicológico , Adulto , Estudios de Factibilidad
19.
J Vasc Surg ; 57(3): 842-4, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23218412

RESUMEN

This report describes a patient with pseudoxanthoma elasticum (PXE) who presented with an incidental finding of a renal artery aneurysm. PXE is a rare genetic condition. It is associated with calcification of elastin fibers and is characterized by skin, eye, and cardiovascular complications. Our patient was previously treated for retinal and gastrointestinal hemorrhage and coronary artery disease, and is under surveillance for cerebral aneurysms. Five reports in the published literature have described aneurysms in patients with PXE, but, to our knowledge, this is the first report of a patient with PXE and renal artery aneurysm. The literature on PXE and aneurysms is reviewed.


Asunto(s)
Aneurisma/etiología , Seudoxantoma Elástico/complicaciones , Arteria Renal , Anastomosis Quirúrgica , Aneurisma/diagnóstico , Aneurisma/patología , Aneurisma/terapia , Biopsia , Embolización Terapéutica , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Hallazgos Incidentales , Angiografía por Resonancia Magnética , Persona de Mediana Edad , Seudoxantoma Elástico/diagnóstico , Seudoxantoma Elástico/genética , Arteria Renal/patología , Arteria Renal/cirugía , Stents , Resultado del Tratamiento
20.
J Endovasc Ther ; 20(4): 536-43, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23914863

RESUMEN

PURPOSE: To investigate the quality of stent-graft fenestrations created in vitro using different needle puncture and balloon dilation angles in different commercial endografts. METHODS: Fenestrations were made in a standardized fashion in 3 different endograft types: Talent monofilament twill woven polyester, Zenith multifilament tubular woven polyester, and Endofit thin-walled expanded polytetrafluoroethylene (PTFE). Punctures were made at 30°, 60°, and 90° angles using a 20-G needle and dilated using 6-mm standard and 7-mm cutting balloons; at least 6 fenestrations were made at each angle with standard balloons and at least 6 with cutting balloons. The 137 fenestrations were examined under light microscopy; quantitative and qualitative digital image analysis was performed to determine size, shape, and fenestration quality. RESULTS: PTFE grafts were easier to puncture/dilate, resulting in larger, elliptical fenestrations with overall better quality than the Dacron grafts; however, the puncture/dilation angle made an impact on the shape and quality of fenestrations. A significant number of fabric tears were observed in PTFE fabric at <90° puncture/dilation angles compared to Dacron grafts. In Dacron grafts, fenestration quality was significantly higher with 90° puncture/dilation angles (higher in Talent grafts). Cutting balloon use resulted in significantly more fabric tears and poor quality fenestrations in all graft types. CONCLUSION: Different endografts behave significantly differently when fenestrations are fashioned. Optimum puncture/dilation is important when considering in vivo fenestration techniques. Improvements in instrumentation, materials, and techniques are required to make this a reliable and reproducible endovascular option.


Asunto(s)
Prótesis Vascular , Stents , Aorta/cirugía , Ensayo de Materiales , Diseño de Prótesis , Punciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA