Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 21(23)2021 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-34884134

RESUMEN

Conventional means of data extraction using optical fiber interrogators are not adequate for fast-paced detection of a target parameter. In this instance, the relationship between the critical meniscus heights (CMH) of several liquids to the extraction speed of a rod submerged in them, have been analyzed. A limitation of a previous interrogator used for the purpose had been light absorption by the liquid due to the used bandwidth of the readily-available light source, i.e., C-band. The newly proposed technique addresses this limitation by utilizing a broadband light source instead, with a Si-photodetector and an Arduino. In addition, the Arduino is capable of extracting data at a relatively faster rate with respect to the conventional optical interrogator. The use of a different operational wavelength (850 nm instead of 1550 nm) increased the r2 and the sensitivity of the sensor. The new setup can measure surface chemistry properties, with the advantage of being comparatively cheaper than the conventionally available interrogator units, thereby providing a suitable alternative to conventional measurement techniques of liquid surface properties, while reducing material waste, i.e., in terms of the required volume for detection of a target parameter, through the use of optical fiber.

2.
Sci Rep ; 9(1): 17469, 2019 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-31767883

RESUMEN

Knowledge of the distribution of the aspect ratios (ARs) in a chemically-synthesized colloidal solution of Gold Nano Rods (GNRs) is an important measure in determining the quality of synthesis, and consequently the performance of the GNRs generated for various applications. In this work, an algorithm has been developed based on the Bellman Principle of Optimality to readily determine the AR distribution of synthesized GNRs in colloidal solutions. This is achieved by theoretically fitting the longitudinal plasmon resonance of GNRs obtained by UV-visible spectroscopy. The AR distribution obtained from the use of the algorithm developed have shown good agreement with those theoretically generated one as well as with the previously reported results. After bench-marking, the algorithm has been applied to determine the mean and standard deviation of the AR distribution of two GNRs solutions synthesized and examined in this work. The comparison with experimentally derived results from the use of expensive Transmission Electron Microscopic images and Dynamic Light Scattering technique shows that the algorithm developed offers a fast and thus potentially cost-effective solution to determine the quality of the synthesized GNRs specifically needed for many potential applications for the advanced sensor systems.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA