Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 130-135, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37975539

RESUMEN

INTRODUCTION: Cavo-tricuspid isthmus (CTI) dependent atrial flutter (AFL) is one of the most common atrial arrhythmias involving the right atrium (RA) for which radiofrequency catheter ablation has been widely used as a therapy of choice. However, there is limited data on the effect of this intervention on cardiac size and function. METHODS: A retrospective study was conducted on 468 patients who underwent ablation for CTI dependent typical AFL at a single institution between 2010 and 2019. After excluding patients with congenital or rheumatic heart disease, heart transplant recipients, or those without baseline echocardiogram, a total of 130 patients were included in the analysis. Echocardiographic data were analyzed at baseline before ablation, and at early follow-up within 1-year postablation. Follow-up echocardiographic data was available for 55 patients. RESULTS: Of the 55 patients with CTI-AFL, the mean age was 64.2 ± 14.8 years old with 14.5% (n = 8) female. The average left ventricular ejection fraction (LVEF) significantly improved on follow-up echo (40.2 ± 16.9 to 50.4 ± 14.9%, p < .0001), of which 50% of patients had an improvement in LVEF of at least 10%. There was a significant reduction in left atrial volume index (82.74 ± 28.5 to 72.96 ± 28 mL/m2 , p = .008) and RA volume index (70.62 ± 25.6 to 64.15 ± 31 mL/m2 , p = .046), and a significant improvement in left atrial reservoir strain (13.04 ± 6.8 to 19.10 ± 7.7, p < .0001). CONCLUSIONS: Patients who underwent CTI dependent AFL ablation showed an improvement in cardiac size and function at follow-up evaluation. While long-term results are still unknown, these findings indicate that restoration of sinus rhythm in patients with typical AFL is associated with improvement in atrial size and left ventricular function.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
2.
Artículo en Inglés | MEDLINE | ID: mdl-38738814

RESUMEN

INTRODUCTION: Ablation of scar-related reentrant atrial tachycardia (SRRAT) involves identification and ablation of a critical isthmus. A graph convolutional network (GCN) is a machine learning structure that is well-suited to analyze the irregularly-structured data obtained in mapping procedures and may be used to identify potential isthmuses. METHODS: Electroanatomic maps from 29 SRRATs were collected, and custom electrogram features assessing key tissue and wavefront properties were calculated for each point. Isthmuses were labeled off-line. Training data was used to determine the optimal GCN parameters and train the final model. Putative isthmus points were predicted in the training and test populations and grouped into proposed isthmus areas based on density and distance thresholds. The primary outcome was the distance between the centroids of the true and closest proposed isthmus areas. RESULTS: A total of 193 821 points were collected. Thirty isthmuses were detected in 29 tachycardias among 25 patients (median age 65.0, 5 women). The median (IQR) distance between true and the closest proposed isthmus area centroids was 8.2 (3.5, 14.4) mm in the training and 7.3 (2.8, 16.1) mm in the test group. The mean overlap in areas, measured by the Dice coefficient, was 11.5 ± 3.2% in the training group and 13.9 ± 4.6% in the test group. CONCLUSION: A GCN can be trained to identify isthmus areas in SRRATs and may help identify critical ablation targets.

3.
J Cardiovasc Nurs ; 36(5): 470-481, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32675627

RESUMEN

BACKGROUND: Depression and anxiety in patients with atrial fibrillation (AF) and/or atrial flutter may influence the effectiveness of cardioversion and ablation. There is a lack of knowledge related to depressive symptoms and anxiety at the time of these procedures. OBJECTIVE: We aimed to describe the prevalence and explore potential covariates of depressive symptoms and anxiety in patients with AF at the time of cardioversion or ablation. We further explored the influence of depressive symptoms and anxiety on quality of life at the time of procedure and 6-month AF recurrence. METHODS: Depressive symptoms, anxiety, and quality of life were collected at the time of cardioversion or ablation using the Patient Health Questionnaire-9, State-Trait Anxiety Inventory, and Atrial Fibrillation Effect on Quality of Life questionnaire. Presence of AF recurrence within 6 months post procedure was evaluated. RESULTS: Participants (N = 171) had a mean (SD) age of 61.20 (11.23) years and were primarily male (80.1%) and white, non-Hispanic (81.4%). Moderate to severe depressive symptoms (17.2%) and clinically significant state (30.2%) and trait (23.6%) anxiety were reported. Mood/anxiety disorder diagnosis was associated with all 3 symptoms. Atrial fibrillation symptom severity was associated with both depressive symptoms and trait anxiety. Heart failure diagnosis and digoxin use were also associated with depressive symptoms. Trends toward significance between state and trait anxiety and participant race/ethnicity as well as depressive symptoms and body mass index were observed. Study findings support associations between symptoms and quality of life, but not 6-month AF recurrence. CONCLUSION: Depressive symptoms and anxiety are common in patients with AF. Healthcare providers should monitor patients with AF for depressive symptoms and anxiety at the time of procedures and intervene when indicated. Additional investigations on assessment, prediction, treatment, and outcome of depressive symptoms and anxiety in patients with AF are warranted.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ansiedad/epidemiología , Trastornos de Ansiedad , Fibrilación Atrial/complicaciones , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Aleteo Atrial/epidemiología , Aleteo Atrial/terapia , Depresión/epidemiología , Depresión/terapia , Cardioversión Eléctrica , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Recurrencia , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 31(12): 3086-3096, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33022765

RESUMEN

INTRODUCTION: Electrocardiographic characteristics in COVID-19-related mortality have not yet been reported, particularly in racial/ethnic minorities. METHODS AND RESULTS: We reviewed demographics, laboratory and cardiac tests, medications, and cardiac rhythm proximate to death or initiation of comfort care for patients hospitalized with a positive SARS-CoV-2 reverse-transcriptase polymerase chain reaction in three New York City hospitals between March 1 and April 3, 2020 who died. We described clinical characteristics and compared factors contributing toward arrhythmic versus nonarrhythmic death. Of 1258 patients screened, 133 died and were enrolled. Of these, 55.6% (74/133) were male, 69.9% (93/133) were racial/ethnic minorities, and 88.0% (117/133) had cardiovascular disease. The last cardiac rhythm recorded was VT or fibrillation in 5.3% (7/133), pulseless electrical activity in 7.5% (10/133), unspecified bradycardia in 0.8% (1/133), and asystole in 26.3% (35/133). Most 74.4% (99/133) died receiving comfort measures only. The most common abnormalities on admission electrocardiogram included abnormal QRS axis (25.8%), atrial fibrillation/flutter (14.3%), atrial ectopy (12.0%), and right bundle branch block (11.9%). During hospitalization, an additional 17.6% developed atrial ectopy, 14.7% ventricular ectopy, 10.1% atrial fibrillation/flutter, and 7.8% a right ventricular abnormality. Arrhythmic death was confirmed or suspected in 8.3% (11/133) associated with age, coronary artery disease, asthma, vasopressor use, longer admission corrected QT interval, and left bundle branch block (LBBB). CONCLUSIONS: Conduction, rhythm, and electrocardiographic abnormalities were common during COVID-19-related hospitalization. Arrhythmic death was associated with age, coronary artery disease, asthma, longer admission corrected QT interval, LBBB, ventricular ectopy, and usage of vasopressors. Most died receiving comfort measures.


Asunto(s)
Arritmias Cardíacas/mortalidad , COVID-19/mortalidad , Mortalidad Hospitalaria , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etnología , Arritmias Cardíacas/terapia , COVID-19/diagnóstico , COVID-19/etnología , COVID-19/terapia , Causas de Muerte , Comorbilidad , Electrocardiografía , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Mortalidad Hospitalaria/etnología , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Ciudad de Nueva York/epidemiología , Pronóstico , Factores Raciales , Estudios Retrospectivos , Medición de Riesgo , Factores de Tiempo
5.
J Cardiovasc Electrophysiol ; 31(6): 1249-1254, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32281214

RESUMEN

A global coronavirus (COVID-19) pandemic occurred at the start of 2020 and is already responsible for more than 74 000 deaths worldwide, just over 100 years after the influenza pandemic of 1918. At the center of the crisis is the highly infectious and deadly SARS-CoV-2, which has altered everything from individual daily lives to the global economy and our collective consciousness. Aside from the pulmonary manifestations of disease, there are likely to be several electrophysiologic (EP) sequelae of COVID-19 infection and its treatment, due to consequences of myocarditis and the use of QT-prolonging drugs. Most crucially, the surge in COVID-19 positive patients that have already overwhelmed the New York City hospital system requires conservation of hospital resources including personal protective equipment (PPE), reassignment of personnel, and reorganization of institutions, including the EP laboratory. In this proposal, we detail the specific protocol changes that our EP department has adopted during the COVID-19 pandemic, including performance of only urgent/emergent procedures, after hours/7-day per week laboratory operation, single attending-only cases to preserve PPE, appropriate use of PPE, telemedicine and video chat follow-up appointments, and daily conferences to collectively manage the clinical and ethical dilemmas to come. We discuss also discuss how we perform EP procedures on presumed COVID positive and COVID tested positive patients to highlight issues that others in the EP community may soon face in their own institution as the virus continues to spread nationally and internationally.


Asunto(s)
Centros Médicos Académicos/provisión & distribución , Betacoronavirus , Infecciones por Coronavirus/diagnóstico , Electrofisiología/métodos , Equipo de Protección Personal/normas , Neumonía Viral/diagnóstico , COVID-19 , Humanos , Pandemias , SARS-CoV-2
6.
J Cardiovasc Nurs ; 35(4): 327-336, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32015256

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is associated with high recurrence rates and poor health-related quality of life (HRQOL) but few effective interventions to improve HRQOL exist. OBJECTIVE: The aim of this study was to examine the impact of the "iPhone Helping Evaluate Atrial Fibrillation Rhythm through Technology" (iHEART) intervention on HRQOL in patients with AF. METHODS: We randomized English- and Spanish-speaking adult patients with AF to receive either the iHEART intervention or usual care for 6 months. The iHEART intervention used smartphone-based electrocardiogram monitoring and motivational text messages. Three instruments were used to measure HRQOL: the Atrial Fibrillation Effect on Quality of Life (AFEQT), the 36-item Short-Form Health survey, and the EuroQol-5D. We used linear mixed models to compare the effect of the iHEART intervention on HRQOL, quality-adjusted life-years, and AF symptom severity. RESULTS: A total of 238 participants were randomized to the iHEART intervention (n = 115) or usual care (n = 123). Of the participants, 77% were men and 76% were white. More than half (55%) had an AF recurrence. Both arms had improved scores from baseline to follow-up for AFEQT and AF symptom severity scores. The global AFEQT score improved 18.5 and 11.2 points in the intervention and control arms, respectively (P < .05). There were no statistically significant differences in HRQOL, quality-adjusted life-years, or AF symptom severity between groups. CONCLUSIONS: We found clinically meaningful improvements in AF-specific HRQOL and AF symptom severity for both groups. Additional research with longer follow-up should examine the influence of smartphone-based interventions for AF management on HRQOL and address the unique needs of patients diagnosed with different subtypes of AF.


Asunto(s)
Fibrilación Atrial/diagnóstico , Electrocardiografía/instrumentación , Monitoreo Ambulatorio/métodos , Procesamiento de Señales Asistido por Computador/instrumentación , Teléfono Inteligente/estadística & datos numéricos , Anciano , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Calidad de Vida , Encuestas y Cuestionarios , Envío de Mensajes de Texto/estadística & datos numéricos
7.
Indian Pacing Electrophysiol J ; 20(6): 250-256, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32861812

RESUMEN

BACKGROUND: The COVID-19 pandemic has greatly altered the practice of cardiac electrophysiology around the world for the foreseeable future. Professional organizations have provided guidance for practitioners, but real-world examples of the consults and responsibilities cardiac electrophysiologists face during a surge of COVID-19 patients is lacking. METHODS: In this observational case series we report on 29 consecutive inpatient electrophysiology consultations at a major academic medical center in New York City, the epicenter of the pandemic in the United States, during a 2 week period from March 30-April 12, 2020, when 80% of hospital beds were occupied by COVID-19 patients, and the New York City metropolitan area accounted for 10% of COVID-19 cases worldwide. RESULTS: Reasons for consultation included: Atrial tachyarrhythmia (31%), cardiac implantable electronic device management (28%), bradycardia (14%), QTc prolongation (10%), ventricular arrhythmia (7%), post-transcatheter aortic valve replacement conduction abnormality (3.5%), ventricular pre-excitation (3.5%), and paroxysmal supraventricular tachycardia (3.5%). Twenty-four patients (86%) were positive for COVID-19 by nasopharyngeal swab. All elective procedures were canceled, and only one urgent device implantation was performed. Thirteen patients (45%) required in-person evaluation and the remainder were managed remotely. CONCLUSION: Our experience shows that the application of a massive alteration in workflow and personnel forced by the pandemic allowed our team to efficiently address the intersection of COVID-19 with a range of electrophysiology issues. This experience will prove useful as guidance for emerging hot spots or areas affected by future waves of the pandemic.

8.
J Cardiovasc Electrophysiol ; 30(11): 2220-2228, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31507001

RESUMEN

OBJECTIVE: This study evaluated the impact of daily ECG (electrocardiogram) self-recordings on time to documented recurrent atrial fibrillation (AF) or atrial flutter (AFL) and time to treatment of recurrent arrhythmia in patients undergoing catheter radiofrequency ablation (RFA) or direct current cardioversion (DCCV) for AF/AFL. BACKGROUND: AF recurrence rates after RFA and DCCV are 20% to 45% and 60% to 80%, respectively. Randomized trials comparing mobile ECG devices to standard of care have not been performed in an AF/AFL population after treatment. METHODS: Of 262 patients consented, 238 were randomized to either standard of care (123) or to receive the iHEART intervention (115). Patients in the intervention group were provided with and trained to use an AliveCor KardiaMobile ECG monitor, and were instructed to take and transmit daily ECG recordings. Data were collected from transmitted ECG recordings and patients' electronic health records. RESULTS: In a multivariate Cox model, the likelihood of recurrence detection was greater in the intervention group (hazard ratio = 1.56, 95% confidence interval [CI]: 1.06-2.30, P = .024). Hazard ratios did not differ significantly for RFA and DCCV procedures. Recurrence during the first month after ablation strongly predicted later recurrence (hazard ratio = 4.53, 95% CI: 2.05-10.00, P = .0006). Time from detection to treatment was shorter for the control group (hazard ratio = 0.33, 95% CI: 0.57-2.92, P < .0001). CONCLUSIONS: The use of mobile ECG self-recording devices allows for earlier detection of AF/AFL recurrence and may empower patients to engage in shared health decision-making.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/terapia , Aleteo Atrial/terapia , Teléfono Celular , Cardioversión Eléctrica , Electrocardiografía Ambulatoria/instrumentación , Frecuencia Cardíaca , Ablación por Radiofrecuencia , Tecnología de Sensores Remotos/instrumentación , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aplicaciones Móviles , Ciudad de Nueva York , Valor Predictivo de las Pruebas , Estudios Prospectivos , Ablación por Radiofrecuencia/efectos adversos , Recurrencia , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Autocuidado , Factores de Tiempo , Resultado del Tratamiento
9.
Pacing Clin Electrophysiol ; 42(5): 542-547, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30829416

RESUMEN

BACKGROUND: Leadless pacemakers (LPMs) have been shown to have lower postoperative complications than traditional permanent pacemakers but there have been no studies on the outcomes of LPMs in patients with transcatheter heart valve replacements (THVRs). This study determined outcomes of LPMs compared to transvenous single-chamber pacemakers (SCPs) post-THVR. METHODS: This is a retrospective single-center study including 10 patients who received LPMs post-THVR between February 2017 and August 2018 and a comparison group of 23 patients who received SCP post-THVR between July 2008 and August 2018. LPM or SCP was implanted at the discretion of electrophysiologists for atrial fibrillation with slow ventricular response or sinus node dysfunction with need for single-chamber pacing only. RESULTS: LPMs were associated with decreased tricuspid regurgitation (P = 0.04) and decreased blood loss during implantation (7.5 ± 2.5 cc for LPMs vs 16.8 ± 3.2 cc for SCPs, P = 0.03). Five LPM patients had devices positioned in the right ventricular septum as seen on transthoracic echocardiogram. Frequency of ventricular pacing was similar between LPM and SCP groups. In the LPM group, one case was complicated by a pseudoaneurysm and one death was due to noncardiac causes. There was one pneumothorax and one pocket infection in the SCP group. CONCLUSIONS: In this small retrospective study, LPMs were feasible post-THVR and found to perform as well as SCPs, had less intraprocedural blood loss, and were associated with less tricuspid regurgitation. Further, larger studies are required to follow longer-term outcomes and complications.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Procedimientos Quirúrgicos Cardíacos , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide/prevención & control , Anciano de 80 o más Años , Ecocardiografía , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos
12.
Pacing Clin Electrophysiol ; 40(4): 391-400, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28151545

RESUMEN

BACKGROUND: Atrial fibrillation (AF) prevalence increases significantly with age. Little is known about the effect of AF ablation on quality of life and healthcare utilization in the elderly. The objective of this study was to quantify the healthcare utilization and quality of life benefits of catheter ablation for AF, for patients ≥65 years compared to patients <65 years. METHODS: Two multicenter U.S. registry studies enrolled patients with paroxysmal AF. Baseline characteristics and acute outcomes were collected for 736 patients receiving catheter ablation with the Navistar® ThermoCool® SF Catheter (Biosense Webster, Inc., Diamond Bar, CA, USA). Healthcare utilization and quality of life outcomes were collected through 1 year postablation for 508 patients. RESULTS: The rates of acute pulmonary vein isolation were high and similar between patients ≥65 years and <65 years (97.5% vs 95.8%, P = 0.2130). Length of stay for the index procedure was similar between age groups with 82.2% of the older group and 83.2% of the younger group having one-day hospitalization. Disease-specific quality of life instrument scores improved significantly and similarly for older and younger patients at 1 year postablation, compared to baseline. AF-related hospitalizations and emergency department visits were similar or lower in older patients compared to younger patients, as reported at 1 year postablation. CONCLUSION: For older patients undergoing catheter ablation for paroxysmal AF, healthcare utilization parameters were lower or not significantly different than for younger patients, and quality of life outcomes were similarly improved. These findings support the use of catheter ablation as a treatment option in older patients with paroxysmal AF.


Asunto(s)
Fibrilación Atrial/psicología , Fibrilación Atrial/cirugía , Ablación por Catéter/psicología , Ablación por Catéter/estadística & datos numéricos , Accesibilidad a los Servicios de Salud/estadística & datos numéricos , Calidad de Vida/psicología , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Distribución por Sexo , Resultado del Tratamiento , Estados Unidos/epidemiología , Revisión de Utilización de Recursos , Adulto Joven
13.
J Cardiovasc Electrophysiol ; 26(11): 1187-1195, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26228873

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) ablation patients often manifest atrial tachycardias (AT) with atypical ECG morphologies that preclude accurate localization and mechanism. Diagnostic maneuvers used to define ATs during electrophysiology studies can be limited by tachycardia termination or transformation. Additional methods of characterizing post-AF ablation ATs are required. METHODS AND RESULTS: We evaluated the utility of noninvasive ECG signal analytics in postablation AF patients for the following features: (1) Localization of ATs (i.e., right vs. left atrium), and (2) Identification of common left AT mechanisms (i.e., focal vs. macroreentrant). Atrial waveforms from the surface ECG were used to analyze (1) spectral organization, including dominant amplitude (DA) and mean spectral profile (MP), and (2) temporospatial variability, using temporospatial correlation coefficients. We studied 94 ATs in 71 patients who had undergone prior pulmonary vein isolation for AF and returned for a second ablation: (1) right atrial cavotricuspid-isthmus dependent (CTI) ATs (n = 21); (2) left atrial macroreentrant ATs (n = 41) and focal ATs (n = 32). Right CTI ATs manifested higher DAs and lower MPs than left ATs, indicative of greater stability and less complexity in the frequency spectrum. Left macroreentrant ATs possessed higher temporospatial organization than left focal ATs. CONCLUSIONS: Noninvasively recorded atrial waveform signal analyses show that right ATs possess more stable activation properties than left ATs, and left macroreentrant ATs manifest higher temporospatial organization than left focal ATs. Further prospective analyses evaluating the role these novel ECG-derived tools can play to help localize and identify mechanisms of common ATs in AF ablation patients are warranted.

14.
Curr Opin Cardiol ; 30(3): 259-66, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25807223

RESUMEN

PURPOSE OF REVIEW: Patients with atrial fibrillation and heart failure experience an increased morbidity and mortality from the hemodynamic consequences of atrial fibrillation and an increased stroke risk. Consequently, there has been increased attention to procedural alternatives to pharmacologic rhythm control and anticoagulation for stroke prevention. This review aims to evaluate the evidence for atrial fibrillation ablation and left atrial appendage closure in heart failure patients. RECENT FINDINGS: Several randomized control trials and systematic reviews demonstrate the safety and efficacy of atrial fibrillation ablation in patients with heart failure and left ventricular systolic dysfunction. In multiple trials, these patients have shown clinical benefit from atrial fibrillation ablation including improved left ventricular systolic function, quality of life, and clinical heart failure symptoms. The evidence of clinical benefit of atrial fibrillation ablation in heart failure patients with preserved ejection fraction remains limited. Only a handful of randomized controlled trials have been performed evaluating left atrial appendage closure, and there is insufficient data regarding the safety and efficacy of these procedures in heart failure patients. SUMMARY: Atrial fibrillation ablation in heart failure patients remains well tolerated with an overall efficacy comparable to atrial fibrillation ablation in patients without heart failure. There is consistent evidence for the clinical benefit of atrial fibrillation ablation in heart failure patients with left ventricular systolic dysfunction and limited evidence for atrial fibrillation ablation in heart failure patients with preserved ejection fraction. Currently, there is insufficient data regarding the safety and efficacy of left atrial appendage closure devices in heart failure patients.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Insuficiencia Cardíaca/complicaciones , Accidente Cerebrovascular/prevención & control , Disfunción Ventricular Izquierda/complicaciones , Fibrilación Atrial/complicaciones , Humanos , Dispositivo Oclusor Septal , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
15.
Eur Heart J ; 35(2): 69-76, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24144789

RESUMEN

Current interventional procedures in structural heart disease and cardiac arrhythmias require peri-interventional echocardiographic monitoring and guidance to become as safe, expedient, and well-tolerated for patients as possible. Intracardiac echocardiography (ICE) complements and has in part replaced transoesophageal echocardiography (TEE), including real-time three-dimensional (RT-3D) imaging. The latter is still widely accepted as a method to prepare for and to guide interventional treatments. In contrast to TEE, ICE represents a purely intraprocedural guiding and imaging tool unsuitable for diagnostic purposes. Patients tolerate ICE much better, and the method does not require general anaesthesia. Accurate imaging of the particular pathology, its anatomic features, and spatial relation to the surrounding structures is critical for catheter and wire positioning, device deployment, evaluation of the result, and for ruling out complications. This review describes the peri-interventional role of ICE, outlines current limitations, and points out future implications. Two-dimensional ICE has become a suitable guiding tool for a variety of percutaneous treatments in patients who are conscious or under monitored anaesthesia care, whereas RT-3DICE is still undergoing clinical testing. Continuous TEE monitoring under general anaesthesia remains a widely accepted alternative.


Asunto(s)
Ecocardiografía/métodos , Cardiopatías/diagnóstico por imagen , Apéndice Atrial/cirugía , Cateterismo Cardíaco/economía , Cateterismo Cardíaco/métodos , Cardiología/educación , Análisis Costo-Beneficio , Ecocardiografía/economía , Europa (Continente) , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Cuidados Intraoperatorios/métodos , Anuloplastia de la Válvula Mitral/métodos , Dispositivo Oclusor Septal , Ultrasonografía Intervencional/economía , Ultrasonografía Intervencional/métodos , Estados Unidos , Técnicas de Cierre de Heridas
16.
J Cardiovasc Electrophysiol ; 25(8): 852-858, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24602038

RESUMEN

INTRODUCTION: This report presents safety data on the use of a new open-irrigation radiofrequency ablation (RFA) catheter with a 56-hole porous tip in 742 patients enrolled in 2 US prospective, multicenter observational registry studies representing real-world use of the catheter. METHODS: This analysis is comprised of patients who underwent RFA of drug-refractory recurrent symptomatic paroxysmal atrial fibrillation (AF). Acute adverse events (AEs) were collected and categorized by seriousness, timing, and relatedness, with 7 days of follow-up data in one study and at least 120 days of data from a 1-year follow-up in the other. Acute serious adverse events (SAEs) that were identified as potentially related to the device and/or procedure were adjudicated by an independent safety committee. RESULTS: A total of 30 patients (4.0%) in the combined studies experienced an acute SAE related to the device and/or procedure, which was similar in the subset of patients age 65 and over (4.2%). These SAEs included 1.2% cardiac tamponade/perforation, 0.7% pericarditis, 0.5% pulmonary events, and 0.8% vascular access complications. No myocardial infarction, stroke, transient ischemic attack, or atrioesophageal fistulas within 7 days postprocedure were reported. In the study with extended follow-up, 1 pulmonary vein stenosis and 1 esophageal injury were seen beyond 7 days postprocedure (0.2% each). There were no device or procedure related deaths. CONCLUSION: Results from 2 large observational studies demonstrated that a new porous tip RFA catheter was safe for the treatment of drug refractory, recurrent, symptomatic paroxysmal AF, including treatment of older patients (≥65 years).


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Irrigación Terapéutica/instrumentación , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Sistema de Registros , Factores de Riesgo , Irrigación Terapéutica/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
17.
Pacing Clin Electrophysiol ; 37(3): 336-44, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23998759

RESUMEN

BACKGROUND: When atrial fibrillation (AF) is incessant, imaging during a prolonged ventricular RR interval may improve image quality. It was hypothesized that long RR intervals could be predicted from preceding RR values. METHODS: From the PhysioNet database, electrocardiogram RR intervals were obtained from 74 persistent AF patients. An RR interval lengthened by at least 250 ms beyond the immediately preceding RR interval (termed T0 and T1, respectively) was considered prolonged. A two-parameter scatterplot was used to predict the occurrence of a prolonged interval T0. The scatterplot parameters were: (1) RR variability (RRv) estimated as the average second derivative from 10 previous pairs of RR differences, T13-T2, and (2) Tm-T1, the difference between Tm, the mean from T13 to T2, and T1. For each patient, scatterplots were constructed using preliminary data from the first hour. The ranges of parameters 1 and 2 were adjusted to maximize the proportion of prolonged RR intervals within range. These constraints were used for prediction of prolonged RR in test data collected during the second hour. RESULTS: The mean prolonged event was 1.0 seconds in duration. Actual prolonged events were identified with a mean positive predictive value (PPV) of 80% in the test set. PPV was >80% in 36 of 74 patients. An average of 10.8 prolonged RR intervals per 60 minutes was correctly identified. CONCLUSIONS: A method was developed to predict prolonged RR intervals using two parameters and prior statistical sampling for each patient. This or similar methodology may help improve cardiac imaging in many longstanding persistent AF patients.


Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
Pacing Clin Electrophysiol ; 37(1): 79-89, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24033806

RESUMEN

BACKGROUND: Although local electrograms during atrial fibrillation (AF) are often spectrally analyzed over 8-second (8s) intervals, changes may be common over intervals as short as 2s. We sought to determine whether averaged 2s measurements of electrogram spectral parameters were similar to 8s measurements, and whether the 2s intervals could provide an estimate of the temporal stability of the signal frequency content in paroxysmal versus persistent AF. METHODS: Complex fractionated atrial electrograms (CFAEs) were acquired outside the pulmonary vein ostia and from free wall sites in nine paroxysmal and 10 longstanding persistent AF patients. Using a 2s sliding calculation window, a frequency spectrum was computed every 100 ms over an interval of 8.4 seconds (82 spectra in total). The dominant frequency (DF), the dominant amplitude (DA), and the mean spectral profile (MP) were measured. The 2s measurements were compared to single 8.4-second interval measurements. Coefficients of variation (COV) were computed from the 82 spectra for each CFAE recording to determine temporal variability of parameters. RESULTS: Over the sliding 2s computation intervals, as for fixed 8.4-second computation intervals, mean DA and DF were significantly higher in longstanding persistent AF while MP was significantly higher in paroxysmal AF (P ≤ 0.001). The COV was significantly higher for the DF parameter in paroxysmal AF (P < 0.001) and significantly higher for the MP parameter in persistent AF (P < 0.02). CONCLUSIONS: For both paroxysmal and persistent AF data, the 2s sliding window averages provide similar results to single 8.4-second intervals, and information regarding temporal stability was additionally obtained in the process.


Asunto(s)
Algoritmos , Artefactos , Fibrilación Atrial/diagnóstico , Mapeo del Potencial de Superficie Corporal/métodos , Interpretación Estadística de Datos , Diagnóstico por Computador/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
19.
Biomed Eng Online ; 13: 61, 2014 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-24886214

RESUMEN

BACKGROUND: Real-time spectral analyzers can be difficult to implement for PC computer-based systems because of the potential for high computational cost, and algorithm complexity. In this work a new spectral estimator (NSE) is developed for real-time analysis, and compared with the discrete Fourier transform (DFT). METHOD: Clinical data in the form of 216 fractionated atrial electrogram sequences were used as inputs. The sample rate for acquisition was 977 Hz, or approximately 1 millisecond between digital samples. Real-time NSE power spectra were generated for 16,384 consecutive data points. The same data sequences were used for spectral calculation using a radix-2 implementation of the DFT. The NSE algorithm was also developed for implementation as a real-time spectral analyzer electronic circuit board. RESULTS: The average interval for a single real-time spectral calculation in software was 3.29 µs for NSE versus 504.5 µs for DFT. Thus for real-time spectral analysis, the NSE algorithm is approximately 150× faster than the DFT. Over a 1 millisecond sampling period, the NSE algorithm had the capability to spectrally analyze a maximum of 303 data channels, while the DFT algorithm could only analyze a single channel. Moreover, for the 8 second sequences, the NSE spectral resolution in the 3-12 Hz range was 0.037 Hz while the DFT spectral resolution was only 0.122 Hz. The NSE was also found to be implementable as a standalone spectral analyzer board using approximately 26 integrated circuits at a cost of approximately $500. The software files used for analysis are included as a supplement, please see the Additional files 1 and 2. CONCLUSIONS: The NSE real-time algorithm has low computational cost and complexity, and is implementable in both software and hardware for 1 millisecond updates of multichannel spectra. The algorithm may be helpful to guide radiofrequency catheter ablation in real time.


Asunto(s)
Algoritmos , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Procesamiento de Señales Asistido por Computador , Programas Informáticos , Equipos y Suministros Eléctricos , Electrocardiografía/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Diseño de Equipo , Humanos
20.
J Interv Card Electrophysiol ; 67(2): 409-424, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38038816

RESUMEN

BACKGROUND: Esophageal perforation and fistula formation are rare but serious complications following atrial fibrillation ablation. In this review article, we outline the incidence, pathophysiology, predictors, and preventative strategies of this dreaded complication. METHODS: We conducted an electronic search in 10 databases/electronic search engines to access relevant publications. All articles reporting complications following atrial fibrillation ablation, including esophageal injury and fistula formation, were included for systematic review. RESULTS: A total of 130 manuscripts were identified for the final review process. The overall incidence of esophageal injury following atrial fibrillation ablation was significantly higher with thermal ablation modalities (radiofrequency 5-40%, cryoballoon 3-25%, high-intensity focused ultrasound < 10%) as opposed to non-thermal ablation modalities (no cases reported to date). The incidence of esophageal perforation and fistula formation with the use of thermal ablation modalities is estimated to occur in less than 0.25% of all atrial fibrillation ablation procedures. The use of luminal esophageal temperature monitoring probe and mechanical esophageal deviation showed protective effect toward reducing the incidence of this complication. The prognosis is very poor for patients who develop atrioesophageal fistula, and the condition is rapidly fatal without surgical intervention. CONCLUSIONS: Esophageal perforation and fistula formation following atrial fibrillation ablation are rare complications with poor prognosis. Various strategies have been proposed to protect the esophagus and reduce the incidence of this fearful complication. Pulsed field ablation is a promising new ablation technology that may be the future answer toward reducing the incidence of esophageal complications.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fístula Esofágica , Perforación del Esófago , Humanos , Perforación del Esófago/complicaciones , Perforación del Esófago/cirugía , Fístula Esofágica/epidemiología , Fístula Esofágica/etiología , Fístula Esofágica/cirugía , Pronóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA