Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37199171

RESUMEN

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38385529

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS: FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION: In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION: Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fístula , Venas Pulmonares , Femenino , Humanos , Masculino , Antiarrítmicos , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Constricción Patológica/cirugía , Fístula/cirugía , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Taquicardia/cirugía , Resultado del Tratamiento , Persona de Mediana Edad , Anciano
3.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37379528

RESUMEN

AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Poria , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía , Venas Pulmonares/cirugía , Recurrencia
4.
Am Heart J ; 250: 45-56, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35537503

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) provides an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). In patients with a long-term or permanent contraindication for OAC randomized controlled trial (RCT) data is lacking. STUDY OBJECTIVES: To assess the efficacy and safety of LAAO in AF patients who are ineligible to use OAC. The co-primary efficacy endpoint is (1) time to first occurrence of stroke (ischemic, hemorrhagic, or undetermined) and (2) time to first occurrence of the composite of stroke, transient ischemic attack (TIA), and systemic embolism (SE). The primary safety endpoint is the 30-day rate of peri-procedural complications. STUDY DESIGN: This is a multicenter, investigator-initiated, open-label, blinded endpoint (PROBE), superiority-driven RCT. Patients with AF, a CHA2DS2-VASc score ≥2 for men and ≥3 for women and a long-term or permanent contraindication for OAC will be randomized in a 2:1 fashion to the device- or control arm. Patients in the device arm will undergo percutaneous LAAO and will receive post-procedural dual antiplatelet therapy (DAPT) per protocol, while those in the control arm will continue their current treatment consisting of no antithrombotic therapy or (D)APT as deemed appropriate by the primary responsible physician. In this endpoint-driven trial design, assuming a 50% lower stroke risk of LAAO compared to conservative treatment, 609 patients will be followed for a minimum of 1 and a maximum of 5 years. Cost-effectiveness and budget impact analyses will be performed to allow decision-making on reimbursement of LAAO for the target population in the Netherlands. SUMMARY: The COMPARE LAAO trial will investigate the clinical superiority in preventing thromboembolic events and cost-effectiveness of LAAO in AF patients with a high thromboembolic risk and a contraindication for OAC use. NCT TRIAL NUMBER: NCT04676880.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Anticoagulantes , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Femenino , Humanos , Masculino , Nivel de Atención , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/prevención & control , Tromboembolia/etiología , Tromboembolia/prevención & control , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 33(3): 559-564, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35040534

RESUMEN

BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Parálisis/etiología , Nervio Frénico , Venas Pulmonares/cirugía , Resultado del Tratamiento
6.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35647644

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Accidente Cerebrovascular , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto Joven
7.
Europace ; 23(23 Suppl 2): ii23-ii27, 2021 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-33837757

RESUMEN

Treatment of symptomatic atrial fibrillation has seen important changes in the past decades. Advancements have especially been made in the field of non-pharmacological treatment of this disease. Patients in whom a rhythm control strategy is chosen the place of catheter ablation has become more frontline therapy in the past years. The procedure itself has also seen changes in technologies that can be used, either using point-by-point radiofrequency or one of the single-shot techniques. One of the major limitations that remain is that re-do procedures are often necessary due to incomplete pulmonary vein isolation and/or atrial fibrillation being initiated by other mechanisms than pulmonary vein triggers. Therefore, there is further need for developing ablation tools that reproducibly isolate the pulmonary vein transmurally. Furthermore, addressing the underlying conditions before and after catheter ablation has been shown to be of great importance. In this review, we will give an overview of the evolution of catheter ablation, highlight the latest technologies and their future endeavours, and lifestyle modifications are being discussed as part of the catheter ablation strategy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento
8.
Europace ; 23(10): 1568-1576, 2021 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-34143871

RESUMEN

AIMS: This study evaluates the efficacy and safety of first-line single-stage hybrid ablation of (long-standing) persistent atrial fibrillation (AF), over a follow-up period of 2 years, and provides additional information on arrhythmia recurrences and electrophysiological findings at repeat ablation. METHODS AND RESULTS: This is a prospective cohort study that included 49 patients (65% persistent AF; 35% long-standing persistent AF) who underwent hybrid ablation as first-line ablation treatment (no previous endocardial ablation). Patients were relatively young (57.0 ± 8.5 years) and predominantly male (89.8%). Median CHA2DS2-VASc score was 1.0 (0.5; 2.0) and mean left atrium volume index was 43.7 ± 10.9 mL/m2. Efficacy was assessed by 12-lead electrocardiography and 72-h Holter monitoring after 3, 6, 12, and 24 months. Recurrence was defined as AF/atrial flutter (AFL)/tachycardia (AT) recorded by electrocardiography or Holter monitoring lasting >30 s during 2-year follow-up. At 2-year follow-up, single and multiple procedure success rates were 67% and 82%, respectively. Two (4%) patients experienced a major complication (bleeding) requiring intervention following hybrid ablation. Among the 16 (33%) patients who experienced an AF/AFL/AT recurrence, 13 (81%) were ATs/AFLs and only 3 (19%) were AF. Repeat ablation was performed in 10 (20%) patients and resulted in sinus rhythm in 7 (70%) at 2-year follow-up. CONCLUSION: First-line single-stage hybrid AF ablation is an effective treatment strategy for patients with persistent and long-standing persistent AF with an acceptable rate of major complications. Recurrences are predominantly AFL/AT that can be successfully ablated percutaneously. Hybrid ablation seems a feasible approach for first-line ablation of (long-standing) persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Electrocardiografía Ambulatoria , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento
9.
Europace ; 23(9): 1359-1368, 2021 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-33899093

RESUMEN

AIMS: Maintaining sinus rhythm in patients with persistent atrial fibrillation (AF) is challenging. We explored the efficacy of class I and III antiarrhythmic drugs (AADs) in patients with persistent AF and mild to moderate heart failure (HF). METHODS AND RESULTS: In the RACE 3 trial, patients with early persistent symptomatic AF and short history of mild to moderate HF with preserved or reduced left ventricular ejection fraction (LVEF) were randomized to targeted or conventional therapy. Both groups received AF and HF guideline-driven treatment. Additionally, the targeted-group received mineralocorticoid receptor antagonists, statins, angiotensin-converting enzyme inhibitors and/or receptor blockers, and cardiac rehabilitation. Class I and III AADs could be instituted in case of symptomatic recurrent AF. Eventually, pulmonary vein isolation could be performed. Primary endpoint was sinus rhythm on 7-day Holter after 1-year. Included were 245 patients, age 65 ± 9 years, 193 (79%) men, AF history was 3 (2-6) months, HF history 2 (1-4) months, 72 (29.4%) had HF with reduced LVEF. After baseline electrical cardioversion (ECV), 190 (77.6%) had AF recurrences; 108 (56.8%) received class I/III AADs; 19 (17.6%) flecainide, 36 (33.3%) sotalol, 3 (2.8%) dronedarone, 50 (46.3%) amiodarone. At 1-year 73 of 108 (68.0%) patients were in sinus rhythm, 44 (40.7%) without new AF recurrences. Maintenance of sinus rhythm was significantly better with amiodarone [n = 29/50 (58%)] compared with flecainide [n = 6/19 (32%)] and sotalol/dronedarone [n = 9/39 (23%)], P = 0.0064. Adverse events occurred in 27 (25.0%) patients, were all minor and reversible. CONCLUSION: In stable HF patients with early persistent AF, AAD treatment was effective in nearly half of patients, with no serious adverse effects reported.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Anciano , Antiarrítmicos/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Función Ventricular Izquierda
10.
Europace ; 23(2): 216-225, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33141152

RESUMEN

AIMS: Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1-3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. METHODS AND RESULTS: The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P ≤ 0.001) and vascular complications (C-RF 1.7% vs. Ph-RF 1.2% vs. CB 1.3%, P ≤ 0.001). Ph-RF was associated with fewer bleeding complications (C-RF: 1.0% vs. Ph-RF: 0.4% vs. CB: 0.7%, P = 0.020). Phrenic nerve palsy mainly occurred in patients treated with CB (C-RF: 0.1% vs. Ph-RF: 0.2% vs. CB: 1.5%, P ≤ 0.001). In total, 18.4% of patients were referred for repeat ablation within 1 year. Female sex, age, and CHA2DS2-VASc were independent risk factors for cardiac tamponade and bleeding complications, with an adjusted OR for female patients of 2.97 (95% CI 1.98-4.45) and 2.02 (95% CI 1.03-4.00) respectively. CONCLUSION: The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Países Bajos/epidemiología , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
11.
Europace ; 22(8): 1162-1172, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32642768

RESUMEN

AIMS: Atrial fibrillation (AF) often starts as a paroxysmal self-terminating arrhythmia. Limited information is available on AF patterns and episode duration of paroxysmal AF. In paroxysmal AF patients, we longitudinally studied the temporal AF patterns, the association with clinical characteristics, and prevalence of AF progression. METHODS AND RESULTS: In this interim analysis of the Reappraisal of AF: Interaction Between HyperCoagulability, Electrical Remodelling, and Vascular Destabilisation in the Progression of AF (RACE V) registry, 202 patients with paroxysmal AF were followed with continuous rhythm monitoring (implantable loop recorder or pacemaker) for 6 months. Mean age was 64 ± 9 years, 42% were women. Atrial fibrillation history was 2.1 (0.5-4.4) years, CHA2DS2-VASc 1.9 ± 1.3, 101 (50%) had hypertension, 69 (34%) heart failure. One-third had no AF during follow-up. Patients with long episodes (>12 hours) were often men with more comorbidities (heart failure, coronary artery disease, higher left ventricular mass). Patients with higher AF burden (>2.5%) were older with more comorbidities (worse renal function, higher calcium score, thicker intima media thickness). In 179 (89%) patients, 1-year rhythm follow-up was available. On a quarterly basis, average daily AF burden increased from 3.2% to 3.8%, 5.2%, and 6.1%. Compared to the first 6 months, 111 (62%) patients remained stable during the second 6 months, 39 (22%) showed progression to longer AF episodes, 8 (3%) developed persistent AF, and 29 (16%) patients showed AF regression. CONCLUSIONS: In paroxysmal AF, temporal patterns differ suggesting that paroxysmal AF is not one entity. Atrial fibrillation burden is low and determined by number of comorbidities. Atrial fibrillation progression occurred in a substantial number. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov identifier NCT02726698.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Marcapaso Artificial , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Grosor Intima-Media Carotídeo , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros
13.
Europace ; 17(1): 84-93, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25186457

RESUMEN

AIM: Left ventricular (LV) lead placement in the latest activated region is an important determinant of response to cardiac resynchronization therapy (CRT). We investigated the feasibility of coronary venous electroanatomic mapping (EAM) to guide LV lead placement to the latest activated region. METHODS AND RESULTS: Twenty-five consecutive CRT candidates with left bundle-branch block underwent intra-procedural coronary venous EAM using EnSite NavX. A guidewire was used to map the coronary veins during intrinsic activation, and to test for phrenic nerve stimulation (PNS). The latest activated region, defined as the region with an electrical delay >75% of total QRS duration, was located anterolaterally in 18 (basal, n = 10; mid, n = 8) and inferolaterally in 6 (basal, n = 3; mid, n = 3). In one patient, identification of the latest activated region was impeded by limited coronary venous anatomy. In patients with >1 target vein (n = 12), the anatomically targeted inferolateral vein was rarely the vein with maximal electrical delay (n = 3). A concordant LV lead position was achieved in 18 of 25 patients. In six patients, this was hampered by PNS (n = 4), lead instability (n = 1), and coronary vein stenosis (n = 1). CONCLUSION: Coronary venous EAM can be used intraprocedurally to guide LV lead placement to the latest activated region free of PNS. This approach especially contributes to optimization of LV lead electrical delay in patients with multiple target veins. Conventional anatomical LV lead placement strategy does not target the vein with maximal electrical delay in many of these patients.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Bloqueo de Rama/prevención & control , Cateterismo Cardíaco/métodos , Terapia de Resincronización Cardíaca/métodos , Ventrículos Cardíacos/cirugía , Implantación de Prótesis/métodos , Anciano , Bloqueo de Rama/diagnóstico , Dispositivos de Terapia de Resincronización Cardíaca , Vasos Coronarios , Electrodos Implantados , Femenino , Humanos , Masculino , Resultado del Tratamiento
14.
Europace ; 17(6): 898-901, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26023176

RESUMEN

AIMS: Headache has been reported to occur during cryoballoon ablation for atrial fibrillation (AF). No study has systematically analysed this phenomenon. METHODS AND RESULTS: Twenty consecutive patients with symptomatic AF underwent cryoballoon ablation without sedation. Headache was evaluated before, during, and after the first cryoapplication in every pulmonary vein (PV) using a visual representation of a head for location of the headache, a numerical rating scale (NRS) for measuring pain intensity and the short-form McGill pain questionnaire (MPQ) for qualitative analysis of pain. The order in which the PVs were ablated was randomized. Sixteen (80%) patients perceived mainly frontal headache during cryoablation. The overall NRS scores were significantly higher during (5.1 ± 1.7), compared with before (2.7 ± 1.4), and after (3.5 ± 2.2) a cryoapplication (P < 0.05). The NRS score was significantly higher during ablation of the first PV. The intensity of the perceived headache was not related to the temperature reached 150 s after initiation of a cryoapplication (P = 0.81). Of the MPQ, three sensory adjectives and one affective adjective averaged between scores 1 and 2, representing mild-to-moderate severity of pain. CONCLUSION: The majority of patients treated by balloon cryoablation experienced headache during a cryoapplication. There was no correlation between the temperature reached during a cryoballoon freeze and the intensity of the headache. Cryoballoon ablation of the first PV was significantly more painful than the remaining PVs.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Cefalea/epidemiología , Complicaciones Intraoperatorias/epidemiología , Complicaciones Posoperatorias/epidemiología , Venas Pulmonares/cirugía , Anciano , Estudios de Cohortes , Femenino , Cefalea/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Estudios Prospectivos
15.
Europace ; 17(5): 747-52, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25600767

RESUMEN

AIMS: Transcatheter pulmonary vein ablation is the current treatment of choice for symptomatic drug-refractory atrial fibrillation (AF). Video-assisted surgical pulmonary vein isolation (sPVI) is an alternative therapy to percutaneous ablation for the treatment of AF. Long-term results of sPVI are currently unknown. The aim of this study was to report on the long-term efficacy and safety of sPVI in patients with paroxysmal AF. METHODS AND RESULTS: The study design was observational and retrospective. From July 2005 to January 2011, 42 patients with drug-refractory paroxysmal AF underwent video-assisted sPVI in two different centres. Patients were eligible for sPVI when suffering from symptomatic, drug-refractory paroxysmal AF and they agreed to the alternative of sPVI. The median preoperative AF duration was 24 months (range 3-200). Success was defined as the absence of AF on 24 h or 96 h Holter monitoring during follow-up, off antiarrhythmic drugs (AAD). Adverse events and follow-up monitoring were based on the Heart Rhythm Society Consensus Statement 2012 for the catheter and surgical ablation of AF. Mean age was 55 ± 10 years, and 76% were males. After a mean follow-up of 5 years (SD 1.7), 69% of all patients were free from atrial arrhythmias without the use of AAD, and 83% with the use of AAD. Major peri-procedural adverse events occurred in four (9.5%) patients, no strokes or mortalities were registered during long-term follow-up. CONCLUSION: This retrospective study shows that sPVI for the treatment of paroxysmal AF is effective and that the outcomes are maintained at long-term follow-up.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Cirugía Torácica Asistida por Video/métodos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Inducción de Remisión , Estudios Retrospectivos , Cirugía Torácica Asistida por Video/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
16.
Europace ; 16(11): 1546-53, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24668517

RESUMEN

AIMS: In patients with atrial fibrillation (AF), echocardiographic tissue velocity imaging (TVI) enables assessment of electrical and structural remodelling by measuring, respectively, the AF cycle length (AFCL-TVI) and the atrial fibrillatory wall motion velocity (AFV-TVI). We investigated the clinical and echocardiographic correlates of atrial remodelling assessed by TVI. METHODS AND RESULTS: We studied 215 patients presenting with AF. In all patients, we measured the AFCL-TVI and the AFV-TVI in the left atrium. Standard baseline characteristics were recorded. We divided patients by median value of AFV-TVI and AFCL-TVI to evaluate the determinants of atrial remodelling. A low AFV-TVI was related with a longer median duration of the current AF episode, a higher prevalence of significant mitral regurgitation and a thicker left ventricle (LV). Multivariate analysis revealed that a low AFV-TVI was independently associated with a longer median duration of the current AF episode [OR 0.09 (95% CI 0.03-0.027); P < 0.001]. Univariately, a short AFCL-TVI was associated with a long median duration of the current AF episode, the use of anti-arrhythmic drugs, a lower LV ejection fraction (LVEF) and a smaller left atrial volume index (LAVI). Multivariate analysis revealed that LVEF [OR 1.48 (95% CI 1.09-2.01); P = 0.013] and LAVI [OR 1.37 (95% CI 1.08-1.74); P = 0.010] were independently associated with AFCL-TVI. CONCLUSION: This study investigated the clinical and echocardiographic correlates of atrial remodelling assessed by TVI. The AFV-TVI is reduced in patients with a long AF duration and who have mitral regurgitation. In addition, the AFCL is long if LAVI is high and LVEF preserved. Tissue velocity imaging parameters measured during AF may be helpful to characterize the degree of atrial remodelling and optimize treatment.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Función del Atrio Izquierdo , Remodelación Atrial , Ecocardiografía Doppler en Color , Atrios Cardíacos/diagnóstico por imagen , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo/efectos de los fármacos , Remodelación Atrial/efectos de los fármacos , Estudios Transversales , Femenino , Atrios Cardíacos/efectos de los fármacos , Atrios Cardíacos/fisiopatología , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda
17.
J Electrocardiol ; 47(2): 202-11, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24444866

RESUMEN

Based on existing literature and some new data we propose a simple three-step strategy using the standard 12-lead ECG for patient selection and optimal delivery of cardiac resynchronization therapy (CRT). (1) Complete LBBB with regard to the indication for CRT can probably best be identified by a QRS duration of ≥ 130 ms for women and ≥ 120 ms for men with the presence of mid-QRS notch-/slurring in ≥ 2 contiguous leads of V1, V2, V5, V6, I and aVL. (2) Left ventricular (LV) free wall pacing should result in a positive QRS complex in lead V1, with estimation of the exact LV lead position in the circumferential and apico-basal direction using lead aVF and the precordial leads, respectively. Wide and fractionated LV-paced QRS complexes may indicate pacing in scar tissue. (3) Atrioventricular and interventricular stimulation intervals may be optimized by adjusting them until precordial leads show fusion patterns between left and right ventricular activation wavefronts in the QRS complex.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Electrocardiografía/métodos , Selección de Paciente , Anciano , Bloqueo de Rama/fisiopatología , Femenino , Humanos , Masculino
18.
Indian Pacing Electrophysiol J ; 14(1): 32-6, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24493914

RESUMEN

Approximately one third of patients treated with cardiac resynchronization therapy do not derive any detectable benefit. In these patients, acute invasive hemodynamic evaluation can be used for therapy optimization. This report describes the use of systematic invasive hemodynamic measurements for clinical decision making in a patient who experienced severe ventricular arrhythmias and clinical deterioration following a biventricular upgrade.

19.
J Cardiovasc Dev Dis ; 11(4)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38667734

RESUMEN

Background: In patients with an implantable cardioverter-defibrillator (ICD) for secondary prevention, sex differences may exist in clinical outcomes. We sought to investigate sex differences in appropriate ICD therapy, appropriate and inappropriate shock, and all-cause mortality in this patient population. Methods: A total of 257 patients who received an ICD for a secondary prevention indication in the University Medical Centre Groningen (UMCG) between 1 January 2012 and 31 December 2018 were retrospectively included in a consecutive manner. Appropriate ICD therapy, comprising shock and antitachycardia pacing (ATP) for ventricular fibrillation (VF) or ventricular tachycardia (VT), was the primary outcome. Results: The patient population included 257 patients, of whom 45 (18%) were women and 212 (82%) were men. The median of the age was 64 (interquartile range (IQR) 53-72) years. During follow-up (median duration 6.2 (IQR 4.8-7.8) years), first appropriate device therapy took place in 10 (22%) patients for women and 85 (40%) patients for men. Female sex was negatively associated with the rate of appropriate ICD therapy, univariably (hazard ratio (HR) 0.48 [95% confidence interval (CI) 0.25-0.93]; p = 0.030) and multivariably (HR 0.44 [95% CI 0.20-0.95]; p = 0.036). Conclusions: Women with secondary prevention ICDs were less likely than men to receive appropriate ICD therapy.

20.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38340118

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Sistema de Registros , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Europa (Continente) , Resultado del Tratamiento , Recurrencia , Reoperación/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA