Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 34(2): 1146-1154, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37615760

RESUMEN

OBJECTIVES: To investigate whether baseline 18F-sodium fluoride (NaF) and 18F-choline PET activity is associated with metastatic castration-resistant prostate cancer (mCRPC) global and individual bone metastases' DWI MR imaging response to radium-223 treatment. METHODS: Thirty-six bone-only mCRPC patients were prospectively recruited from three centers. Whole-body (WB)-MRI with DWI and 18F-NaF and 18F-choline PET/CT were performed at therapy baseline and 8-week intervals. In each patient, bone disease median global (g)ADC change between baseline and follow-up was calculated. Additionally, up to five bone target lesions per patient were delineated and individual median ADC change recorded. An ADC increase > 30% defined response per-patient and per-lesion. For the same targets, baseline 18F-NaF and 18F-choline PET SUVmax were recorded. Mean SUVmax across patient targets was correlated with gADC change and lesion SUVmax with per-lesion ADC change. RESULTS: A total of 133 lesions in 36 patients (14 responders) were analyzed. 18F-NaF PET per-patient mean SUVmax was significantly higher in responders (median = 56.0 versus 38.7 in non-responders; p = 0.008), with positive correlation between SUVmax and gADC increase (rho = 0.42; p = 0.015). A 48.7 SUVmax threshold identified responders with 77% sensitivity and 75% specificity. Baseline 18F-NaF PET per-lesion SUVmax was higher in responding metastases (median = 51.6 versus 31.8 in non-responding metastases; p = 0.001), with positive correlation between baseline lesion SUVmax and ADC increase (rho = 0.39; p < 0.001). A 36.8 SUVmax threshold yielded 72% sensitivity and 63% specificity. No significant association was found between baseline 18F-choline PET SUVmax and ADC response on a per-patient (p = 0.164) or per-lesion basis (p = 0.921). CONCLUSION: 18F-NaF PET baseline SUVmax of target mCRPC bone disease showed significant association with response to radium-223 defined by ADC change. CLINICAL RELEVANCE STATEMENT: 18F-sodium fluoride PET/CT baseline maximum SUV of castration-resistant prostate cancer bone metastases could be used as a predictive biomarker for response to radium-223 therapy. KEY POINTS: • 18F-sodium fluoride PET baseline SUVmax of castration-resistant prostate cancer bone metastases showed significant association with response to radium-223. • Baseline 18F-sodium fluoride PET can improve patient selection for radium-223 therapy. • Change in whole-body DWI parameters can be used for response correlation with baseline 18F-sodium fluoride PET SUVmax in castration-resistant prostate cancer bone metastases.


Asunto(s)
Neoplasias Óseas , Colina/análogos & derivados , Neoplasias de la Próstata Resistentes a la Castración , Radio (Elemento) , Humanos , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluoruro de Sodio/uso terapéutico , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Radioisótopos de Flúor , Neoplasias Óseas/tratamiento farmacológico
2.
Eur Radiol ; 33(2): 863-871, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36169688

RESUMEN

OBJECTIVE: To establish optimised diffusion weightings ('b-values') for acquisition of whole-body diffusion-weighted MRI (WB-DWI) for estimation of the apparent diffusion coefficient (ADC) in patients with metastatic melanoma (MM). Existing recommendations for WB-DWI have not been optimised for the tumour properties in MM; therefore, evaluation of acquisition parameters is essential before embarking on larger studies. METHODS: Retrospective clinical data and phantom experiments were used. Clinical data comprised 125 lesions from 14 examinations in 11 patients with multifocal MM, imaged before and/or after treatment with immunotherapy at a single institution. ADC estimates from these data were applied to a model to estimate the optimum b-value. A large non-diffusing phantom was used to assess eddy current-induced geometric distortion. RESULTS: Considering all tumour sites from pre- and post-treatment examinations together, metastases exhibited a large range of mean ADC values, [0.67-1.49] × 10-3 mm2/s, and the optimum high b-value (bhigh) for ADC estimation was 1100 (10th-90th percentile: 740-1790) s/mm2. At higher b-values, geometric distortion increased, and longer echo times were required, leading to reduced signal. CONCLUSIONS: Theoretical optimisation gave an optimum bhigh of 1100 (10th-90th percentile: 740-1790) s/mm2 for ADC estimation in MM, with the large range of optimum b-values reflecting the wide range of ADC values in these tumours. Geometric distortion and minimum echo time increase at higher b-values and are not included in the theoretical optimisation; bhigh in the range 750-1100 s/mm2 should be adopted to maintain acceptable image quality but performance should be evaluated for a specific scanner. KEY POINTS: • Theoretical optimisation gave an optimum high b-value of 1100 (10th-90th percentile: 740-1790) s/mm2 for ADC estimation in metastatic melanoma. • Considering geometric distortion and minimum echo time (TE), a b-value in the range 750-1100 s/mm2 is recommended. • Sites should evaluate the performance of specific scanners to assess the effect of geometric distortion and minimum TE.


Asunto(s)
Melanoma , Neoplasias Primarias Secundarias , Humanos , Estudios Retrospectivos , Imagen de Difusión por Resonancia Magnética/métodos , Melanoma/diagnóstico por imagen , Fantasmas de Imagen , Reproducibilidad de los Resultados
3.
Radiology ; 291(1): 5-13, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30806604

RESUMEN

Acknowledging the increasingly important role of whole-body MRI for directing patient care in myeloma, a multidisciplinary, international, and expert panel of radiologists, medical physicists, and hematologists with specific expertise in whole-body MRI in myeloma convened to discuss the technical performance standards, merits, and limitations of currently available imaging methods. Following guidance from the International Myeloma Working Group and the National Institute for Clinical Excellence in the United Kingdom, the Myeloma Response Assessment and Diagnosis System (or MY-RADS) imaging recommendations are designed to promote standardization and diminish variations in the acquisition, interpretation, and reporting of whole-body MRI in myeloma and allow response assessment. This consensus proposes a core clinical protocol for whole-body MRI and an extended protocol for advanced assessments. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Asunto(s)
Mieloma Múltiple/diagnóstico , Guías de Práctica Clínica como Asunto , Consenso , Recolección de Datos , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Proyectos de Investigación , Imagen de Cuerpo Entero/métodos , Imagen de Cuerpo Entero/normas
4.
Eur Radiol ; 28(4): 1687-1691, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29134357

RESUMEN

OBJECTIVES: The aim of this study was to identify apparent diffusion coefficient (ADC) values for typical haemangiomas in the spine and to compare them with active malignant focal deposits. METHODS: This was a retrospective single-institution study. Whole-body magnetic resonance imaging (MRI) scans of 106 successive patients with active multiple myeloma, metastatic prostate or breast cancer were analysed. ADC values of typical vertebral haemangiomas and malignant focal deposits were recorded. RESULTS: The ADC of haemangiomas (72 ROIs, median ADC 1,085×10-6mm2s-1, interquartile range 927-1,295×10-6mm2s-1) was significantly higher than the ADC of malignant focal deposits (97 ROIs, median ADC 682×10-6mm2s-1, interquartile range 583-781×10-6mm2s-1) with a p-value < 10-6. Receiver operating characteristic (ROC) analysis produced an area under the curve of 0.93. An ADC threshold of 872×10-6mm2s-1 separated haemangiomas from malignant focal deposits with a sensitivity of 84.7 % and specificity of 91.8 %. CONCLUSIONS: ADC values of classical vertebral haemangiomas are significantly higher than malignant focal deposits. The high ADC of vertebral haemangiomas allows them to be distinguished visually and quantitatively from active sites of disease, which show restricted diffusion. KEY POINTS: • Whole-body diffusion-weighted MRI is becoming widely used in myeloma and bone metastases. • ADC values of vertebral haemangiomas are significantly higher than malignant focal deposits. • High ADCs of haemangiomas allows them to be distinguished from active disease.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Hemangioma/diagnóstico por imagen , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/secundario , Imagen de Cuerpo Entero/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mieloma Múltiple/diagnóstico por imagen , Mieloma Múltiple/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
Radiology ; 284(1): 88-99, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28301311

RESUMEN

Purpose To assess the repeatability of apparent diffusion coefficient (ADC) estimates in extracranial soft-tissue diffusion-weighted magnetic resonance imaging across a wide range of imaging protocols and patient populations. Materials and Methods Nine prospective patient studies and one prospective volunteer study, performed between 2006 and 2016 with research ethics committee approval and written informed consent from each subject, were included in this single-institution study. A total of 141 tumors and healthy organs were imaged twice (interval between repeated examinations, 45 minutes to 10 days, depending the on study) to assess the repeatability of median and mean ADC estimates. The Levene test was used to determine whether ADC repeatability differed between studies. The Pearson linear correlation coefficient was used to assess correlation between coefficient of variation (CoV) and the year the study started, study size, and volumes of tumors and healthy organs. The repeatability of ADC estimates from small, medium, and large tumors and healthy organs was assessed irrespective of study, and the Levene test was used to determine whether ADC repeatability differed between these groups. Results CoV aggregated across all studies was 4.1% (range for each study, 1.7%-6.5%). No correlation was observed between CoV and the year the study started or study size. CoV was weakly correlated with volume (r = -0.5, P = .1). Repeatability was significantly different between small, medium, and large tumors (P < .05), with the lowest CoV (2.6%) for large tumors. There was a significant difference in repeatability between studies-a difference that did not persist after the study with the largest tumors was excluded. Conclusion ADC is a robust imaging metric with excellent repeatability in extracranial soft tissues across a wide range of tumor sites, sizes, patient populations, and imaging protocol variations. Online supplemental material is available for this article.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de los Tejidos Blandos/diagnóstico por imagen , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados
6.
Radiology ; 283(1): 168-177, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27875103

RESUMEN

Purpose To determine the usefulness of whole-body diffusion-weighted imaging (DWI) to assess the response of bone metastases to treatment in patients with metastatic castration-resistant prostate cancer (mCRPC). Materials and Methods A phase II prospective clinical trial of the poly-(adenosine diphosphate-ribose) polymerase inhibitor olaparib in mCRPC included a prospective magnetic resonance (MR) imaging substudy; the study was approved by the institutional research board, and written informed consent was obtained. Whole-body DWI was performed at baseline and after 12 weeks of olaparib administration by using 1.5-T MR imaging. Areas of abnormal signal intensity on DWI images in keeping with bone metastases were delineated to derive total diffusion volume (tDV); five target lesions were also evaluated. Associations of changes in volume of bone metastases and median apparent diffusion coefficient (ADC) with response to treatment were assessed by using the Mann-Whitney test and logistic regression; correlation with prostate-specific antigen level and circulating tumor cell count were assessed by using Spearman correlation (r). Results Twenty-one patients were included. All six responders to olaparib showed a decrease in tDV, while no decrease was observed in all nonresponders; this difference between responders and nonresponders was significant (P = .001). Increases in median ADC were associated with increased odds of response (odds ratio, 1.08; 95% confidence interval [CI]: 1.00, 1.15; P = .04). A positive association was detected between changes in tDV and best percentage change in prostate-specific antigen level and circulating tumor cell count (r = 0.63 [95% CI: 0.27, 0.83] and r = 0.77 [95% CI: 0.51, 0.90], respectively). When assessing five target lesions, decreases in volume were associated with response (odds ratio for volume increase, 0.89; 95% CI: 0.80, 0.99; P = .037). Conclusion This pilot study showed that decreases in volume and increases in median ADC of bone metastases assessed with whole-body DWI can potentially be used as indicators of response to olaparib in mCRPC. Online supplemental material is available for this article.


Asunto(s)
Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/secundario , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de la Próstata/patología , Adulto , Anciano , Antineoplásicos/uso terapéutico , Biomarcadores de Tumor , Neoplasias Óseas/tratamiento farmacológico , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Ftalazinas/uso terapéutico , Proyectos Piloto , Piperazinas/uso terapéutico , Estudios Prospectivos , Resultado del Tratamiento , Imagen de Cuerpo Entero
7.
Radiology ; 280(1): 151-60, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26807894

RESUMEN

Purpose To determine the correlation between the volume of bone metastasis as assessed with diffusion-weighted (DW) imaging and established prognostic factors in metastatic castration-resistant prostate cancer (mCRPC) and the association with overall survival (OS). Materials and Methods This retrospective study was approved by the institutional review board; informed consent was obtained from all patients. The authors analyzed whole-body DW images obtained between June 2010 and February 2013 in 53 patients with mCRPC at the time of starting a new line of anticancer therapy. Bone metastases were identified and delineated on whole-body DW images in 43 eligible patients. Total tumor diffusion volume (tDV) was correlated with the bone scan index (BSI) and other prognostic factors by using the Pearson correlation coefficient (r). Survival analysis was performed with Kaplan-Meier analysis and Cox regression. Results The median tDV was 503.1 mL (range, 5.6-2242 mL), and the median OS was 12.9 months (95% confidence interval [CI]: 8.7, 16.1 months). There was a significant correlation between tDV and established prognostic factors, including hemoglobin level (r = -0.521, P < .001), prostate-specific antigen level (r = 0.556, P < .001), lactate dehydrogenase level (r = 0.534, P < .001), alkaline phosphatase level (r = 0.572, P < .001), circulating tumor cell count (r = 0.613, P = .004), and BSI (r = 0.565, P = .001). A higher tDV also showed a significant association with poorer OS (hazard ratio, 1.74; 95% CI: 1.02, 2.96; P = .035). Conclusion Metastatic bone disease from mCRPC can be evaluated and quantified with whole-body DW imaging. Whole-body DW imaging-generated tDV showed correlation with established prognostic biomarkers and is associated with OS in mCRPC. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/secundario , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de la Próstata Resistentes a la Castración/patología , Imagen de Cuerpo Entero/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias Óseas/patología , Huesos/diagnóstico por imagen , Huesos/patología , Supervivencia sin Enfermedad , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Reproducibilidad de los Resultados , Estudios Retrospectivos , Carga Tumoral
8.
Bioengineering (Basel) ; 11(2)2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38391616

RESUMEN

BACKGROUND: Whole-Body Diffusion-Weighted Imaging (WBDWI) is an established technique for staging and evaluating treatment response in patients with multiple myeloma (MM) and advanced prostate cancer (APC). However, WBDWI scans show inter- and intra-patient intensity signal variability. This variability poses challenges in accurately quantifying bone disease, tracking changes over follow-up scans, and developing automated tools for bone lesion delineation. Here, we propose a novel automated pipeline for inter-station, inter-scan image signal standardisation on WBDWI that utilizes robust segmentation of the spinal canal through deep learning. METHODS: We trained and validated a supervised 2D U-Net model to automatically delineate the spinal canal (both the spinal cord and surrounding cerebrospinal fluid, CSF) in an initial cohort of 40 patients who underwent WBDWI for treatment response evaluation (80 scans in total). Expert-validated contours were used as the target standard. The algorithm was further semi-quantitatively validated on four additional datasets (three internal, one external, 207 scans total) by comparing the distributions of average apparent diffusion coefficient (ADC) and volume of the spinal cord derived from a two-component Gaussian mixture model of segmented regions. Our pipeline subsequently standardises WBDWI signal intensity through two stages: (i) normalisation of signal between imaging stations within each patient through histogram equalisation of slices acquired on either side of the station gap, and (ii) inter-scan normalisation through histogram equalisation of the signal derived within segmented spinal canal regions. This approach was semi-quantitatively validated in all scans available to the study (N = 287). RESULTS: The test dice score, precision, and recall of the spinal canal segmentation model were all above 0.87 when compared to manual delineation. The average ADC for the spinal cord (1.7 × 10-3 mm2/s) showed no significant difference from the manual contours. Furthermore, no significant differences were found between the average ADC values of the spinal cord across the additional four datasets. The signal-normalised, high-b-value images were visualised using a fixed contrast window level and demonstrated qualitatively better signal homogeneity across scans than scans that were not signal-normalised. CONCLUSION: Our proposed intensity signal WBDWI normalisation pipeline successfully harmonises intensity values across multi-centre cohorts. The computational time required is less than 10 s, preserving contrast-to-noise and signal-to-noise ratios in axial diffusion-weighted images. Importantly, no changes to the clinical MRI protocol are expected, and there is no need for additional reference MRI data or follow-up scans.

9.
Cancers (Basel) ; 16(9)2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38730599

RESUMEN

(1) Background: We assessed the test-re-test repeatability of radiomics in metastatic castration-resistant prostate cancer (mCPRC) bone disease on whole-body diffusion-weighted (DWI) and T1-weighted Dixon MRI. (2) Methods: In 10 mCRPC patients, 1.5 T MRI, including DWI and T1-weighted gradient-echo Dixon sequences, was performed twice on the same day. Apparent diffusion coefficient (ADC) and relative fat-fraction-percentage (rFF%) maps were calculated. Per study, up to 10 target bone metastases were manually delineated on DWI and Dixon images. All 106 radiomic features included in the Pyradiomics toolbox were derived for each target volume from the ADC and rFF% maps. To account for inter- and intra-patient measurement repeatability, the log-transformed individual target measurements were fitted to a hierarchical model, represented as a Bayesian network. Repeatability measurements, including the intraclass correlation coefficient (ICC), were derived. Feature ICCs were compared with mean ADC and rFF ICCs. (3) Results: A total of 65 DWI and 47 rFF% targets were analysed. There was no significant bias for any features. Pairwise correlation revealed fifteen ADC and fourteen rFF% feature sub-groups, without specific patterns between feature classes. The median intra-patient ICC was generally higher than the inter-patient ICC. Features that describe extremes in voxel values (minimum, maximum, range, skewness, and kurtosis) showed generally lower ICCs. Several mostly shape-based texture features were identified, which showed high inter- and intra-patient ICCs when compared with the mean ADC or mean rFF%, respectively. (4) Conclusions: Pyradiomics texture features of mCRPC bone metastases varied greatly in inter- and intra-patient repeatability. Several features demonstrated good repeatability, allowing for further exploration as diagnostic parameters in mCRPC bone disease.

10.
Sci Rep ; 13(1): 10568, 2023 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-37386097

RESUMEN

Handcrafted and deep learning (DL) radiomics are popular techniques used to develop computed tomography (CT) imaging-based artificial intelligence models for COVID-19 research. However, contrast heterogeneity from real-world datasets may impair model performance. Contrast-homogenous datasets present a potential solution. We developed a 3D patch-based cycle-consistent generative adversarial network (cycle-GAN) to synthesize non-contrast images from contrast CTs, as a data homogenization tool. We used a multi-centre dataset of 2078 scans from 1,650 patients with COVID-19. Few studies have previously evaluated GAN-generated images with handcrafted radiomics, DL and human assessment tasks. We evaluated the performance of our cycle-GAN with these three approaches. In a modified Turing-test, human experts identified synthetic vs acquired images, with a false positive rate of 67% and Fleiss' Kappa 0.06, attesting to the photorealism of the synthetic images. However, on testing performance of machine learning classifiers with radiomic features, performance decreased with use of synthetic images. Marked percentage difference was noted in feature values between pre- and post-GAN non-contrast images. With DL classification, deterioration in performance was observed with synthetic images. Our results show that whilst GANs can produce images sufficient to pass human assessment, caution is advised before GAN-synthesized images are used in medical imaging applications.


Asunto(s)
COVID-19 , Aprendizaje Profundo , Humanos , Inteligencia Artificial , COVID-19/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Aprendizaje Automático
11.
Diagnostics (Basel) ; 13(21)2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37958277

RESUMEN

T2-weighted magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) are essential components of cervical cancer diagnosis. However, combining these channels for the training of deep learning models is challenging due to image misalignment. Here, we propose a novel multi-head framework that uses dilated convolutions and shared residual connections for the separate encoding of multiparametric MRI images. We employ a residual U-Net model as a baseline, and perform a series of architectural experiments to evaluate the tumor segmentation performance based on multiparametric input channels and different feature encoding configurations. All experiments were performed on a cohort of 207 patients with locally advanced cervical cancer. Our proposed multi-head model using separate dilated encoding for T2W MRI and combined b1000 DWI and apparent diffusion coefficient (ADC) maps achieved the best median Dice similarity coefficient (DSC) score, 0.823 (confidence interval (CI), 0.595-0.797), outperforming the conventional multi-channel model, DSC 0.788 (95% CI, 0.568-0.776), although the difference was not statistically significant (p > 0.05). We investigated channel sensitivity using 3D GRAD-CAM and channel dropout, and highlighted the critical importance of T2W and ADC channels for accurate tumor segmentation. However, our results showed that b1000 DWI had a minor impact on the overall segmentation performance. We demonstrated that the use of separate dilated feature extractors and independent contextual learning improved the model's ability to reduce the boundary effects and distortion of DWI, leading to improved segmentation performance. Our findings could have significant implications for the development of robust and generalizable models that can extend to other multi-modal segmentation applications.

12.
JNCI Cancer Spectr ; 7(6)2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37788117

RESUMEN

BACKGROUND: Radium-223 is a bone-seeking, ɑ-emitting radionuclide used to treat men with bone metastases from castration-resistant prostate cancer. Sclerotic bone lesions cannot be evaluated using Response Evaluation Criteria in Solid Tumors. Therefore, imaging response biomarkers are needed. METHODS: We conducted a phase 2 randomized trial to assess disease response to radium-223. Men with metastatic castration-resistant prostate cancer and bone metastases were randomly allocated to 55 or 88 kBq/kg radium-223 every 4 weeks for 6 cycles. Whole-body diffusion-weighted magnetic resonance imaging (DWI) was performed at baseline, at cycles 2 and 4, and after treatment. The primary endpoint was defined as a 30% increase in global median apparent diffusion coefficient. RESULTS: Disease response on DWI was seen in 14 of 36 evaluable patients (39%; 95% confidence interval = 23% to 56%), with marked interpatient and intrapatient heterogeneity of response. There was an association between prostate-specific antigen response and MRI response (odds ratio = 18.5, 95% confidence interval = 1.32 to 258, P = .013). Mean administered activity of radium-223 per cycle was not associated with global MRI response (P = .216) but was associated with DWI response using a 5-target-lesion evaluation (P = .007). In 26 of 36 (72%) patients, new bone metastases, not present at baseline, were seen on DWI scans during radium-223 treatment. CONCLUSIONS: DWI is useful for assessment of disease response in bone. Response to radium-223 is heterogeneous, both between patients and between different metastases in the same patient. New bone metastases appear during radium-223 treatment.The REASURE trial is registered under ISRCTN17805587.


Asunto(s)
Neoplasias Óseas , Neoplasias de la Próstata Resistentes a la Castración , Radio (Elemento) , Masculino , Humanos , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Radioisótopos/uso terapéutico , Radio (Elemento)/uso terapéutico , Antígeno Prostático Específico , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/radioterapia , Neoplasias Óseas/patología
13.
Comput Biol Med ; 149: 106091, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36115298

RESUMEN

PURPOSE: To use deep learning to calculate the uncertainty in apparent diffusion coefficient (σADC) voxel-wise measurements to clinically impact the monitoring of treatment response and improve the quality of ADC maps. MATERIALS AND METHODS: We use a uniquely designed diffusion-weighted imaging (DWI) acquisition protocol that provides gold-standard measurements of σADC to train a deep learning model on two separate cohorts: 16 patients with prostate cancer and 28 patients with mesothelioma. Our network was trained with a novel cost function, which incorporates a perception metric and a b-value regularisation term, on ADC maps calculated by combinations of 2 or 3 b-values (e.g. 50/600/900, 50/900, 50/600, 600/900 s/mm2). We compare the accuracy of the deep-learning based approach for estimation of σADC with gold-standard measurements. RESULTS: The model accurately predicted the σADC for every b-value combination in both cohorts. Mean values of σADC within areas of active disease deviated from those measured by the gold-standard by 4.3% (range, 2.87-6.13%) for the prostate and 3.7% (range, 3.06-4.54%) for the mesothelioma cohort. We also showed that the model can easily be adapted for a different DWI protocol and field-of-view with only a few images (as little as a single patient) using transfer learning. CONCLUSION: Deep learning produces maps of σADC from standard clinical diffusion-weighted images (DWI) when 2 or more b-values are available.


Asunto(s)
Mesotelioma , Neoplasias de la Próstata , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Masculino , Mesotelioma/diagnóstico por imagen , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Incertidumbre
14.
Front Oncol ; 12: 892620, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35847882

RESUMEN

A shift in radiology to a data-driven specialty has been unlocked by synergistic developments in imaging biomarkers (IB) and computational science. This is advancing the capability to deliver "virtual biopsies" within oncology. The ability to non-invasively probe tumour biology both spatially and temporally would fulfil the potential of imaging to inform management of complex tumours; improving diagnostic accuracy, providing new insights into inter- and intra-tumoral heterogeneity and individualised treatment planning and monitoring. Soft tissue sarcomas (STS) are rare tumours of mesenchymal origin with over 150 histological subtypes and notorious heterogeneity. The combination of inter- and intra-tumoural heterogeneity and the rarity of the disease remain major barriers to effective treatments. We provide an overview of the process of successful IB development, the key imaging and computational advancements in STS including quantitative magnetic resonance imaging, radiomics and artificial intelligence, and the studies to date that have explored the potential biological surrogates to imaging metrics. We discuss the promising future directions of IBs in STS and illustrate how the routine clinical implementation of a virtual biopsy has the potential to revolutionise the management of this group of complex cancers and improve clinical outcomes.

15.
Front Oncol ; 12: 899180, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35924167

RESUMEN

Background: Size-based assessments are inaccurate indicators of tumor response in soft-tissue sarcoma (STS), motivating the requirement for new response imaging biomarkers for this rare and heterogeneous disease. In this study, we assess the test-retest repeatability of radiomic features from MR diffusion-weighted imaging (DWI) and derived maps of apparent diffusion coefficient (ADC) in retroperitoneal STS and compare baseline repeatability with changes in radiomic features following radiotherapy (RT). Materials and Methods: Thirty patients with retroperitoneal STS received an MR examination prior to treatment, of whom 23/30 were investigated in our repeatability analysis having received repeat baseline examinations and 14/30 patients were investigated in our post-treatment analysis having received an MR examination after completing pre-operative RT. One hundred and seven radiomic features were extracted from the full manually delineated tumor region using PyRadiomics. Test-retest repeatability was assessed using an intraclass correlation coefficient (baseline ICC), and post-radiotherapy variance analysis (post-RT-IMS) was used to compare the change in radiomic feature value to baseline repeatability. Results: For the ADC maps and DWI images, 101 and 102 features demonstrated good baseline repeatability (baseline ICC > 0.85), respectively. Forty-three and 2 features demonstrated both good baseline repeatability and a high post-RT-IMS (>0.85), respectively. Pearson correlation between the baseline ICC and post-RT-IMS was weak (0.432 and 0.133, respectively). Conclusions: The ADC-based radiomic analysis shows better test-retest repeatability compared with features derived from DWI images in STS, and some of these features are sensitive to post-treatment change. However, good repeatability at baseline does not imply sensitivity to post-treatment change.

16.
Radiology ; 261(2): 573-81, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21852566

RESUMEN

PURPOSE: To describe computed diffusion weighted (DW) magnetic resonance (MR) imaging as a method for obtaining high-b-value images from DW MR imaging performed at lower b values and to investigate the feasibility of the technique to improve lesion detection in oncologic cases. MATERIALS AND METHODS: The study was approved by the institutional and research committee, and written informed consent was obtained from all patients. DW MR imaging was performed on a CuSO(4) phantom at 1.5 T with a range of b values and compared with computed DW MR imaging images synthesized from lower b values (0 and 600 sec/mm(2)). The signal-to-noise ratio (SNR) was compared, and agreement between the SNR of computed DW MR imaging and theoretical estimation assessed. Computed DW MR imaging was evaluated in 10 oncologic patients who underwent whole-body DW MR imaging with b values of 0 and 900 sec/mm(2). Computed DW MR images at computed b values of 1500 and 2000 sec/mm(2) were generated. The image quality and background suppression of acquired and computed images were rated by a radiologist using a four-point scale. The diagnostic performance for malignant lesion detection using these images was evaluated and compared by using the McNemar Test. RESULTS: The SNR of computed DW MR imaging of the phantom conformed closely to theoretical predictions. Computed DW MR imaging resulted in a higher SNR compared with acquired DW MR imaging, especially at b values greater than 840 sec/mm(2). In patients, images with a computed b value of 2000 sec/mm(2) produced good image quality and high background suppression (mean scores of 2.8 and 4.0, respectively). Evaluation of images with a computed b value of 2000 sec/mm(2) resulted in higher overall diagnostic sensitivity (96.0%) and specificity (96.6%) compared with images with an acquired b value of 900 sec/mm(2) (sensitivity, 89.4%; specificity, 87.5%; P < .01). CONCLUSION: Computed DW MR imaging in the body allows higher-b-value images to be obtained with a good SNR. Clinical computed DW MR imaging is feasible and may improve disease detection. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101919/-/DC1.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Linfoma/diagnóstico , Neoplasias de la Próstata/diagnóstico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Imagen de Cuerpo Entero
17.
Diagnostics (Basel) ; 11(11)2021 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-34829310

RESUMEN

The recent rise of deep learning (DL) and its promising capabilities in capturing non-explicit detail from large datasets have attracted substantial research attention in the field of medical image processing. DL provides grounds for technological development of computer-aided diagnosis and segmentation in radiology and radiation oncology. Amongst the anatomical locations where recent auto-segmentation algorithms have been employed, the pelvis remains one of the most challenging due to large intra- and inter-patient soft-tissue variabilities. This review provides a comprehensive, non-systematic and clinically-oriented overview of 74 DL-based segmentation studies, published between January 2016 and December 2020, for bladder, prostate, cervical and rectal cancers on computed tomography (CT) and magnetic resonance imaging (MRI), highlighting the key findings, challenges and limitations.

18.
Quant Imaging Med Surg ; 11(8): 3549-3561, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34341730

RESUMEN

BACKGROUND: Morphologic features yield low diagnostic accuracy to distinguish between diseased and normal lymph nodes. The purpose of this study was to compare diseased lymphomatous and normal lymph nodes using global apparent diffusion coefficient (gADC) histogram parameters derived from whole-body diffusion-weighted MRI (WB-DWI). METHODS: 1.5 Tesla WB-DWI of 23 lymphoma patients and 20 healthy volunteers performed between 09/2010 and 07/2015 were retrospectively reviewed. All diseased nodal groups in the lymphoma cohort and all nodes visible on b900 images in healthy volunteers were segmented from neck to groin to generate a total diffusion volume (tDV). A connected component-labelling algorithm separated spatially distinct nodes. Mean, median, skewness, kurtosis, minimum, maximum, interquartile range (IQR), standard deviation (SD), 10th and 90th centile of the gADC distribution were derived from the tDV of each patient/volunteer and from spatially distinct nodes. gADC and regional nodal ADC parameters were compared between malignant and normal nodes using t-tests and ROC curve analyses. A P value ≤0.05 was deemed statistically significant. RESULTS: Mean, median, IQR, 10th and 90th centiles of gADC and regional nodal ADC values were significantly lower in diseased compared with normal lymph nodes. Skewness, kurtosis and tDV were significantly higher in lymphoma. The SD, min and max gADC showed no significant difference between the two groups (P>0.128). The diagnostic accuracies of gADC parameters by AUC from highest to lowest were: 10th centile, mean, median, 90th centile, skewness, kurtosis and IQR. A 10th centile gADC threshold of 0.68×10-3 mm2/s identified diseased lymphomatous nodes with 91% sensitivity and 95% specificity. CONCLUSIONS: WB-DWI derived gADC histogram parameters can distinguish between malignant lymph nodes of lymphoma patients and normal lymph nodes of healthy individuals.

19.
Radiol Artif Intell ; 3(5): e200279, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34617028

RESUMEN

PURPOSE: To use deep learning to improve the image quality of subsampled images (number of acquisitions = 1 [NOA1]) to reduce whole-body diffusion-weighted MRI (WBDWI) acquisition times. MATERIALS AND METHODS: Both retrospective and prospective patient groups were used to develop a deep learning-based denoising image filter (DNIF) model. For initial model training and validation, 17 patients with metastatic prostate cancer with acquired WBDWI NOA1 and NOA9 images (acquisition period, 2015-2017) were retrospectively included. An additional 22 prospective patients with advanced prostate cancer, myeloma, and advanced breast cancer were used for model testing (2019), and the radiologic quality of DNIF-processed NOA1 (NOA1-DNIF) images were compared with NOA1 images and clinical NOA16 images by using a three-point Likert scale (good, average, or poor; statistical significance was calculated by using a Wilcoxon signed ranked test). The model was also retrained and tested in 28 patients with malignant pleural mesothelioma (MPM) who underwent lung MRI (2015-2017) to demonstrate feasibility in other body regions. RESULTS: The model visually improved the quality of NOA1 images in all test patients, with the majority of NOA1-DNIF and NOA16 images being graded as either "average" or "good" across all image-quality criteria. From validation data, the mean apparent diffusion coefficient (ADC) values within NOA1-DNIF images of bone disease deviated from those within NOA9 images by an average of 1.9% (range, 1.1%-2.6%). The model was also successfully applied in the context of MPM; the mean ADCs from NOA1-DNIF images of MPM deviated from those measured by using clinical-standard images (NOA12) by 3.7% (range, 0.2%-10.6%). CONCLUSION: Clinical-standard images were generated from subsampled images by using a DNIF.Keywords: Image Postprocessing, MR-Diffusion-weighted Imaging, Neural Networks, Oncology, Whole-Body Imaging, Supervised Learning, MR-Functional Imaging, Metastases, Prostate, Lung Supplemental material is available for this article. Published under a CC BY 4.0 license.

20.
Front Oncol ; 11: 665807, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34395244

RESUMEN

BACKGROUND: Computed tomography (CT) and magnetic resonance imaging (MRI) are the mainstay imaging modalities in radiotherapy planning. In MR-Linac treatment, manual annotation of organs-at-risk (OARs) and clinical volumes requires a significant clinician interaction and is a major challenge. Currently, there is a lack of available pre-annotated MRI data for training supervised segmentation algorithms. This study aimed to develop a deep learning (DL)-based framework to synthesize pelvic T1-weighted MRI from a pre-existing repository of clinical planning CTs. METHODS: MRI synthesis was performed using UNet++ and cycle-consistent generative adversarial network (Cycle-GAN), and the predictions were compared qualitatively and quantitatively against a baseline UNet model using pixel-wise and perceptual loss functions. Additionally, the Cycle-GAN predictions were evaluated through qualitative expert testing (4 radiologists), and a pelvic bone segmentation routine based on a UNet architecture was trained on synthetic MRI using CT-propagated contours and subsequently tested on real pelvic T1 weighted MRI scans. RESULTS: In our experiments, Cycle-GAN generated sharp images for all pelvic slices whilst UNet and UNet++ predictions suffered from poorer spatial resolution within deformable soft-tissues (e.g. bladder, bowel). Qualitative radiologist assessment showed inter-expert variabilities in the test scores; each of the four radiologists correctly identified images as acquired/synthetic with 67%, 100%, 86% and 94% accuracy. Unsupervised segmentation of pelvic bone on T1-weighted images was successful in a number of test cases. CONCLUSION: Pelvic MRI synthesis is a challenging task due to the absence of soft-tissue contrast on CT. Our study showed the potential of deep learning models for synthesizing realistic MR images from CT, and transferring cross-domain knowledge which may help to expand training datasets for 21 development of MR-only segmentation models.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA