Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anal Chem ; 94(1): 41-58, 2022 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-34870427

RESUMEN

Rapid and low-cost molecular analysis is especially required for early and specific diagnostics, quick decision-making, and sparing patients from unnecessary tests and hospitals from extra costs. One way to achieve this objective is through automated molecular diagnostic devices. Thus, sample-to-answer microfluidic devices are emerging with the promise of delivering a complete molecular diagnosis system that includes nucleic acid extraction, amplification, and detection steps in a single device. The biggest issue in such equipment is the extraction process, which is normally laborious and time-consuming but extremely important for sensitive and specific detection. Therefore, this Review focuses on automated or semiautomated extraction methodologies used in lab-on-a-chip devices. More than 15 different extraction methods developed over the past 10 years have been analyzed in terms of their advantages and disadvantages to improve extraction procedures in future studies. Herein, we are able to explain the high applicability of the extraction methodologies due to the large variety of samples in which different techniques were employed, showing that their applications are not limited to medical diagnosis. Moreover, we are able to conclude that further research in the field would be beneficial because the methodologies presented can be affordable, portable, time efficient, and easily manipulated, all of which are strong qualities for point-of-care technologies.


Asunto(s)
Dispositivos Laboratorio en un Chip , Ácidos Nucleicos , Humanos , Técnicas de Amplificación de Ácido Nucleico , Patología Molecular , Sistemas de Atención de Punto , Manejo de Especímenes
2.
Cancer Invest ; 40(9): 750-759, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35950647

RESUMEN

Seroconversion rates were compared between oncological and nononcological patients infected with SARS-CoV-2 during a 14-day hospitalization time. All COVID-19 non-oncological and solid malignancies patients reached 100% seroconversion at day 14, while less than half of the hematological patients were seroconverted at the same time point. Despite the limited number and variability of the patient's cohort, we conclude that there is a delayed seroconversion in the hematological malignancies group, which may be linked to changes in the hematological parameters, immune suppression and/or oncological treatments that are typically associated with these patients.


Asunto(s)
COVID-19 , Neoplasias , Anticuerpos Antivirales , Humanos , Inmunidad , SARS-CoV-2
3.
Anal Biochem ; 641: 114541, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-34971572

RESUMEN

The detection of BCR-ABL1 mRNA transcripts is essential to molecular chronic myeloid leukemia (CML) diagnosis. In most cases, the RT-qPCR technique is performed as the gold standard diagnosis tool for clinical cases. However, this method requires expensive reagents and equipment, such as a real-time thermal cycler, probes and master mix. Consequently, the development and validation of simple and low-cost methods are essential for a rapid CML diagnosis in less specialized and equipped centers. In this study, we develop and demonstrate an accessible, rapid, and low-cost method using RT-LAMP for BCR-ABL1 detection in both cell lines and CML clinical samples, using fluorescent and colorimetric assays. Both methods demonstrated diagnostic specificity of 100% and while diagnostic sensitivity reaches more than 90% in samples with RT-qPCR cycle threshold above 31. The obtained data indicates that the proposed method here described is robust, specific and rapid approach for CML diagnosis with outstanding performance, especially for CML diagnostic procedure where present high BCR-ABL1 expression.


Asunto(s)
Colorimetría , Proteínas de Fusión bcr-abl/genética , Leucemia Mielógena Crónica BCR-ABL Positiva/diagnóstico , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Línea Celular Tumoral , Proteínas de Fusión bcr-abl/metabolismo , Humanos , Leucemia Mielógena Crónica BCR-ABL Positiva/genética , ARN Mensajero/genética , ARN Mensajero/metabolismo , Espectrometría de Fluorescencia
4.
Microchem J ; 180: 107600, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35620142

RESUMEN

This work describes the development of a Point-of-Care (POC) Lab-on-a-Chip (LOC) instrument for diagnosis of SARS-CoV-2 by Reverse-Transcription Loop-mediated isothermal amplification (RT-LAMP). The hardware is based on a Raspberry Pi computer ($35), a video camera, an Arduino Nano microcontroller, a printed circuit board as a heater and a 3D printed housing. The chips were manufactured in polymethyl methacrylate (PMMA) using a CO2 laser cutting machine and sealed with a PCR optic plastic film. The chip temperature is precisely controlled by a proportional-integral-derivative (PID) algorithm. During the RT-LAMP amplifications the chip was maintained at ∼ (65.0 ± 0.1) °C for 25 minutes and 5 minutes cooling down, totaling a 30 minutes of reaction .The software interpretation occurs in less than a second. The chip design has four 25 µL chambers, two for clinical samples and two for positive and negative control-samples. The RT-LAMP master mix solution added in the chip chambers contains the pH indicator Phenol Red, that is pink (for pH ∼ 8.0) before amplification and becomes yellow (pH ∼ 6.0) if the genetic material is amplified. The RT-LAMP SARS-CoV-2 diagnostic was made by color image recognition using the OpenCV machine vision software library. The software was programmed to automatically distinguish the HSV color parameter distribution in each one of the four chip chambers. The instrument was successfully tested for SARS-CoV-2 diagnosis, in 22 clinic samples, 11 positives and 11 negatives, achieving an assertiveness of 86% when compared to the results obtained by RT-LAMP standard reactions performed in conventional PCR equipment.

5.
Mol Med ; 27(1): 30, 2021 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-33771097

RESUMEN

BACKGROUND: SARS-CoV-2 Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP) colorimetric detection is a sensitive and specific point-of-care molecular biology technique used to detect the virus in only 30 min. In this manuscript we have described a few nuances of the technique still not properly described in the literature: the presence of three colors clusters; the correlation of the viral load with the color change; and the importance of using an internal control to avoid false-negative results. METHODS: To achieve these findings, we performed colorimetric RT-LAMP assays of 466 SARS-CoV-2 RT-qPCR validated clinical samples, with color quantification measured at 434 nm and 560 nm. RESULTS: First we determinate a sensitivity of 93.8% and specificity of 90.4%. In addition to the pink (negative) and yellow (positive) produced colors, we report for the first time the presence of an orange color cluster that may lead to wrong diagnosis. We also demonstrated using RT-qPCR and RT-LAMP that low viral loads are related to Ct values > 30, resulting in orange colors. We also demonstrated that the diagnosis of COVID-19 by colorimetric RT-LAMP is efficient until the fifth symptoms day when the viral load is still relatively high. CONCLUSION: This study reports properties and indications for colorimetric RT-LAMP as point-of-care for SARS-CoV-2 diagnostic, reducing false results, interpretations and optimizing molecular diagnostics tests application.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Pruebas en el Punto de Atención , COVID-19/virología , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa , Transcripción Reversa , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Carga Viral
6.
Biomed Microdevices ; 23(2): 24, 2021 04 14.
Artículo en Inglés | MEDLINE | ID: mdl-33855638

RESUMEN

This article describes the fabrication of a low-cost Polymerase Chain Reaction (PCR) instrument to detect diseases. In order to reduce the instrument price and simplify construction we developed an alternative fabrication process, transforming conventional printed circuit boards (PCB) in heating elements, avoiding the use of aluminum heating/cooling blocks and Peltier devices. To cool down the reaction a simple computer fan was used. The vial holder was fabricated using two double side PCB boards assembled in a sandwich-like configuration. The bottom PCB has a resistance of 0.9 Ω used to heat the reaction mix, while the top layer has a resistance of 1.1 Ω to heat the vial body, preventing vapor condensation. The top board was maintained at ~ 110 ± 1 °C during all cycles. The final device was able to heat and cool down the reaction at rates of ~ 2.0 °C/s, a rate comparable to commercial thermocyclers. An SMD NTC thermistor was used as temperature sensors, and a PID (proportional-integral-derivative) control algorithm was implemented to acquire and precisely control the temperature. We also discuss how the instrument is calibrated. The device was tested successfully for the amplification of T. pallidum (Syphilis) bacterial DNA and Zika virus RNA samples, showing similar performance to a commercial PCR instrument.


Asunto(s)
Infección por el Virus Zika , Virus Zika , Algoritmos , Calefacción , Calor , Humanos , Reacción en Cadena de la Polimerasa , Temperatura
7.
Virol J ; 18(1): 222, 2021 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-34789293

RESUMEN

BACKGROUND: We report a genomic surveillance of SARS-CoV-2 lineages circulating in Paraná, southern Brazil, from March 2020 to April 2021. Our analysis, based on 333 genomes, revealed that the first variants detected in the state of Paraná in March 2020 were the B.1.1.33 and B.1.1.28 variants. The variants B.1.1.28 and B.1.1.33 were predominant throughout 2020 until the introduction of the variant P.2 in August 2020 and a variant of concern (VOC), Gamma (P.1), in January 2021. The VOC Gamma, a ramification of the B.1.1.28 lineage first detected in Manaus (northern Brazil), has grown rapidly since December 2020 and was thought to be responsible for the deadly second wave of COVID-19 throughout Brazil. METHODS: The 333 genomic sequences of SARS-CoV-2 from March 2020 to April 2021 were generated as part of the genomic surveillance carried out by Fiocruz in Brazil Genomahcov Fiocruz. SARS-CoV-2 sequencing was performed using representative samples from all geographic areas of Paraná. Phylogenetic analyses were performed using the 333 genomes also included other SARS-CoV-2 genomes from the state of Paraná and other states in Brazil that were deposited in the GISAID. In addition, the time-scaled phylogenetic tree was constructed with up to 3 random sequences of the Gamma variant from each state in Brazil in each month of 2021. In this analysis we also added the sequences identified as the B.1.1.28 lineage of the Amazonas state and and the Gamma-like-II (P.1-like-II) lineage identified in different regions of Brazil. RESULTS: Phylogenetic analyses of the SARS-CoV-2 genomes that were previously classified as the VOC Gamma lineage by WHO/PANGO showed that some genomes from February to April 2021 branched in a monophyletic clade and that these samples grouped together with genomes recently described with the lineage Gamma-like-II. Additionally, a new mutation (E661D) in the spike (S) protein has been identified in nearly 10% of the genomes classified as the VOC Gamma from Paraná in March and April 2021.Finally, we analyzed the correlation between the lineage and the Gamma variant frequency, age group (patients younger or older than 60 years old) and the clinical data of 86 cases from the state of Paraná. CONCLUSIONS: Our results provided a reliable picture of the evolution of the SARS-CoV-2 pandemic in the state of Paraná characterized by the dominance of the Gamma strain, as well as a high frequencies of the Gamma-like-II lineage and the S:E661D mutation. Epidemiological and genomic surveillance efforts should be continued to unveil the biological relevance of the novel mutations detected in the VOC Gamma in Paraná.


Asunto(s)
COVID-19/virología , SARS-CoV-2 , Brasil/epidemiología , COVID-19/epidemiología , Brotes de Enfermedades , Humanos , Persona de Mediana Edad , Mutación , Filogenia , Vigilancia de la Población , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Glicoproteína de la Espiga del Coronavirus/química , Glicoproteína de la Espiga del Coronavirus/genética , Secuenciación Completa del Genoma
8.
Sensors (Basel) ; 20(17)2020 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-32877999

RESUMEN

This article shows the development of a computer-controlled lab-on-a-chip device with three magnetohydrodynamic (MHD) pumps and a pneumatic valve. The chip was made of a stack of layers of polymethylmethacrylate (PMMA), cut using a laser engraver and thermally bonded. The MHD pumps were built using permanent magnets (neodymium) and platinum electrodes, all of them controlled by an Arduino board and a set of relays. The implemented pumps were able to drive solutions in the open channels with a flow rate that increased proportionally with the channel width and applied voltage. To address the characteristic low pressures generated by this kind of pump, all channels were interconnected. Because the electrodes were immersed in the electrolyte, causing electrolysis and pH variations, the composition and ionic strength of the electrolyte solution were controlled. Additionally, side structures for releasing bubbles were integrated. With this multi-pump and valve solution, the device was used to demonstrate the possibility of performing an injection sequence in a system that resembles a traditional flow injection analysis system. Ultimately, the results demonstrate the possibility of performing injection sequences using an array of MHD pumps that can perform fluid handling in the 0-5 µL s-1 range.

9.
Anal Bioanal Chem ; 408(10): 2567-76, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26873197

RESUMEN

The detection and interpretation of gunshot residues (GSR) plays an important role in the investigation of firearm-related events. Commonly, the analysis focuses on inorganic particles incorporating elements derived from the primer. However, recent changes in ammunition formulations and possibility that particles from non-firearm sources can be indistinguishable from certain primer particles challenge the standard operational protocol and call for adjustments, namely the combination of inorganic and organic GSR analysis. Two protocols for the combined collection and subsequent analysis of inorganic and organic GSR were developed and optimised for 15 compounds potentially present in organic GSR (OGSR). These protocols were conceptualised to enable OGSR analysis by ultrahigh-performance liquid chromatography (UHPLC) coupled with UV detection and triple quadrupole tandem mass spectrometry (confirmation) and IGSR analysis by scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDX). Using liquid extraction, the extraction recoveries from spiked swabs and stubs were ~80 % (50-98 % for swabs, 64-98 % for stubs). When the mixed OGSR standard was applied to the hands and recovered in the way that is usual for IGSR collection, GSR stubs performed significantly better than swabs (~30 %) for the collection of OGSR. The optimised protocols were tested and compared for combined OGSR and inorganic GSR analysis using samples taken at a shooting range. The most suitable protocol for combined collection and analysis of IGSR and OGSR involved collection using GSR stubs followed by SEM-EDX analysis and liquid extraction using acetone followed by analysis with UHPLC.


Asunto(s)
Armas de Fuego , Compuestos Inorgánicos/análisis , Compuestos Orgánicos/análisis , Cromatografía Líquida de Alta Presión/métodos , Microscopía Electrónica de Rastreo , Espectrometría por Rayos X , Espectrofotometría Ultravioleta
10.
Anal Chem ; 86(10): 4707-14, 2014 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-24766256

RESUMEN

A new microfluidic paper-based analytical device (µPAD) in conjunction with confirmation by a lab on chip analysis was developed for detection of three trinitro aromatic explosives. Potassium hydroxide was deposited on the µPADs (0.5 µL, 1.5 M), creating a color change reaction when explosives are present, with detection limits of approximately 7.5 ± 1.0 ng for TNB, 12.5 ± 2.0 ng for TNT and 15.0 ± 2.0 ng for tetryl. For confirmatory analysis, positive µPADs were sampled using a 5 mm hole-punch, followed by extraction of explosives from the punched chad in 30 s using 20 µL borate/SDS buffer. The extractions had efficiencies of 96.5 ± 1.7%. The extracted explosives were then analyzed with the Agilent 2100 Bioanalyzer lab on a chip device with minimum detectable amounts of 3.8 ± 0.1 ng for TNB, 7.0 ± 0.9 ng for TNT, and 4.7 ± 0.2 ng for tetryl. A simulated in-field scenario demonstrated the feasibility of coupling the µPAD technique with the lab on a chip device to detect and identify 1 µg of explosives distributed on a surface of 100 cm(2).

11.
Biosensors (Basel) ; 14(3)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38534235

RESUMEN

This work presents a low-cost transcription loop-mediated isothermal amplification (RT-LAMP) instrument for nucleic acid detection, employing an Arduino Nano microcontroller. The cooling system includes customized printed circuit boards (PCBs) that serve as electrical resistors and incorporate fans. An aluminum block is designed to accommodate eight vials. The system also includes two PCB heaters-one for sample heating and the other for vial lid heating to prevent condensation. The color detection system comprises a TCS3200 color 8-sensor array coupled to one side of the aluminum heater body and a white 8-LED array coupled to the other side, controlled by two Multiplexer/Demultiplexer devices. LED light passes through the sample, reaching the color sensor and conveying color information crucial for detection. The top board is maintained at 110 ± 2 °C, while the bottom board is held at 65 ± 0.5 °C throughout the RT-LAMP assay. Validation tests successfully demonstrated the efficacy of the colorimetric RT-LAMP reactions using SARS-CoV-2 RNA amplification as a sample viability test, achieving 100% sensitivity and 97.3% specificity with 66 clinical samples. Our instrument offers a cost-effective (USD 100) solution with automated result interpretation and superior sensitivity compared to visual inspection. While the prototype was tested with SARS-CoV-2 RNA samples, its versatility extends to detecting other pathogens using alternative primers, showcasing its potential for broader applications in biosensing.


Asunto(s)
ARN Viral , ADN Polimerasa Dirigida por ARN , ADN Polimerasa Dirigida por ARN/genética , ARN Viral/genética , Aluminio , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , ARN Polimerasas Dirigidas por ADN , Sensibilidad y Especificidad
12.
Sci Rep ; 14(1): 10612, 2024 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-38719936

RESUMEN

Molecular diagnostics involving nucleic acids (DNA and RNA) are regarded as extremely functional tools. During the 2020 global health crisis, efforts intensified to optimize the production and delivery of molecular diagnostic kits for detecting SARS-CoV-2. During this period, RT-LAMP emerged as a significant focus. However, the thermolability of the reagents used in this technique necessitates special low-temperature infrastructure for transport, storage, and conservation. These requirements limit distribution capacity and necessitate cost-increasing adaptations. Consequently, this report details the development of a lyophilization protocol for reagents in a colorimetric RT-LAMP diagnostic kit to detect SARS-CoV-2, facilitating room-temperature transport and storage. We conducted tests to identify the ideal excipients that maintain the molecular integrity of the reagents and ensure their stability during room-temperature storage and transport. The optimal condition identified involved adding 5% PEG 8000 and 75 mM trehalose to the RT-LAMP reaction, which enabled stability at room temperature for up to 28 days and yielded an analytical and diagnostic sensitivity and specificity of 83.33% and 90%, respectively, for detecting SARS-CoV-2. This study presents the results of a lyophilized colorimetric RT-LAMP COVID-19 detection assay with diagnostic sensitivity and specificity comparable to RT-qPCR, particularly in samples with high viral load.


Asunto(s)
COVID-19 , Colorimetría , Liofilización , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , ARN Viral , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/virología , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/genética , Colorimetría/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Técnicas de Diagnóstico Molecular/métodos , ARN Viral/análisis , ARN Viral/genética , Sensibilidad y Especificidad , Juego de Reactivos para Diagnóstico/normas , Prueba de Ácido Nucleico para COVID-19/métodos
13.
Anal Methods ; 15(30): 3610-3630, 2023 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-37489903

RESUMEN

Lateral flow assays (LFAs) have emerged as one of the most prominent paper-based biosensor platforms for rapidly detecting and quantifying analytes. Their selectivity, cost-effectiveness, efficiency, and simplicity make them ideal candidates for point-of-care (POC) applications, particularly when time-sensitive decisions are needed, such as cardiovascular events. The profound impact of cardiovascular diseases (CVDs), characterized by their high morbidity, mortality, and rehospitalization rates, necessitates an optimized approach for the early detection of cardiac muscle damage. This comprehensive review aims to consolidate the existing scientific literature on LFAs that specifically target cardiovascular biomarkers, including myoglobin and cardiac troponin I, over the past decade. By examining the advancements and findings in this field, valuable insights can be gained regarding the potential and future directions of LFAs in cardiovascular diagnostics.


Asunto(s)
Enfermedades Cardiovasculares , Sistemas de Atención de Punto , Humanos , Biomarcadores , Troponina I , Enfermedades Cardiovasculares/diagnóstico
14.
Mini Rev Med Chem ; 23(4): 480-496, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35927908

RESUMEN

Molecular biology is a widely used and widespread technique in research and as a laboratory diagnostic tool, aiming to investigate targets of interest from the obtainment, identification, and analysis of genetic material. In this context, methods, such as Polymerase Chain Reaction (PCR), Reverse Transcription Polymerase Chain Reaction (RT-PCR), real-time PCR, loopmediated isothermal amplification (LAMP), and loop-mediated isothermal amplification with reverse transcription (RT-LAMP), can be cited. Such methods use enzymes, buffers, and thermosensitive reagents, which require specific storage conditions. In an attempt to solve this problem, the lyophilization procedure (dehydration process by sublimation) can be applied, aiming to preserve and prolong the useful life of the reaction components in cases of temperature variation. In this review, we present a synthesis of the lyophilization process, describing the events of each step of the procedure and providing general information about the technique. Moreover, we selected lyophilization protocols found in the literature, paying attention to the conditions chosen by the authors for each step of the procedure, and structured the main data in tables, facilitating access to information for researchers who need material to produce new functional protocols.


Asunto(s)
Liofilización , Biología Molecular , Humanos , Biología Molecular/instrumentación , Biología Molecular/métodos , Agua/química , Liofilización/instrumentación , Liofilización/métodos , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/métodos , Criopreservación , Sistemas de Atención de Punto
15.
J Anal Toxicol ; 46(9): 991-998, 2023 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-34792146

RESUMEN

Urine is initially collected from athletes to screen for the presence of illicit drugs. Sweat is an alternative sample matrix that provides advantages over urine including reduced opportunity for sample adulteration, longer detection-time window and non-invasive collection. Sweat is suitable for analysis of the parent drug and metabolites. In this study, a method was developed and validated to determine the presence of 13 amphetamine- and cocaine-related substances and their metabolites in sweat and urine using disposable pipette extraction (DPX) by gas chromatography coupled to mass spectrometry. The DPX extraction was performed using 0.1 M HCl and dichloromethane:isopropanol:ammonium hydroxide (78:20:2, v/v/v) followed by derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide at 90°C for 20 min. DPX extraction efficiencies ranged between 65.0% and 96.0% in urine and 68.0% and 101.0% in sweat. Method accuracy was from 90.0% to 104.0% in urine and from 89.0% to 105.0% in sweat. Intra-assay precision in urine and in sweat were <15.6% and <17.8%, respectively, and inter-assay precision ranged from 4.70% to 15.3% in urine and from 4.05% to 15.4% in sweat. Calibration curves presented a correlation coefficient -0.99 for all analytes in both matrices. The validated method was applied to urine and sweat samples collected from 40 professional athletes who knowingly took one or more of the target illicit drugs. Thirteen of 40 athletes were positive for at least one drug. All the drugs detected in the urine were also detected in sweat samples indicating that sweat is a viable matrix for screening or confirmatory drug testing.


Asunto(s)
Estimulantes del Sistema Nervioso Central , Cocaína , Doping en los Deportes , Drogas Ilícitas , Humanos , Sudor/química , Cromatografía de Gases y Espectrometría de Masas/métodos , Espectrometría de Masas , Estimulantes del Sistema Nervioso Central/análisis , Cocaína/análisis , Drogas Ilícitas/análisis
16.
Anal Chim Acta ; 1258: 341169, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37087292

RESUMEN

3D-printing has shown an outstanding performance for the production of versatile electrochemical devices. However, there is a lack of studies in the field of 3D-printed miniaturized settings for multiplex biosensing. In this work, we propose a fully 3D-printed micro-volume cell containing six working electrodes (WEs) that operates with 250 µL of sample. A polylactic acid/carbon black conductive filament (PLA/CB) was used to print the WEs and subsequently modified with graphene oxide (GO), to support protein binding. Cyclic voltammetry was employed to investigate the electrochemical behaviour of the novel multi-electrode cell. In the presence of K3[Fe(CN)6], PLA/CB/GO showed adequate peak resolution for subsequent label-free immunosensing. The innovative 3D-printed cell was applied for multiplex voltammetric detection of three COVID-19 biomarkers as a proof-of-concept. The multiple sensors showed a wide linear range with detection limits of 5, 1 and 1 pg mL-1 for N-protein, SRBD-protein, and anti-SRBD, respectively. The sensor performance enabled the selective sequential detection of N protein, SRBD protein, and anti-SRBD at biological levels in saliva and serum. In summary, the miniaturized six-electrode cell presents an alternative for the low-cost and fast production of customizable devices for multi-target sensing with promising application in the development of point-of-care sensors.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , Electrodos , Microelectrodos , Poliésteres , Impresión Tridimensional , Biomarcadores
17.
Electrophoresis ; 33(6): 893-8, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22528408

RESUMEN

Over the past years, the development of capillary electrophoresis (CE) and microchip electrophoresis (ME) systems has grown due to instrumental simplicity and wide application. In both CE and ME, the application of a high voltage (HV) is a crucial step in the electrokinetic (EK) injection and separation processes. Particularly on ME devices, EK injection is often performed with three different modes: gated, pinched, and unpinched. In all these cases, different potential values may be applied to one or multiple channels to control the injection of small sample volumes as well as the separation process. For this reason, the construction of reliable HV power supplies (HVPS) is required. This review covers the advances of the development of commercial and laboratory-built HVPS for CE and ME. Moreover, it intends to be a guide for new developers of electrophoresis instrumentation.


Asunto(s)
Suministros de Energía Eléctrica , Electroforesis Capilar/instrumentación , Electroforesis por Microchip/instrumentación , Miniaturización
18.
Sci Rep ; 11(1): 9026, 2021 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-33907239

RESUMEN

The use of RT-LAMP (reverse transcriptase-loop mediated isothermal amplification) has been considered as a promising point-of-care method to diagnose COVID-19. In this manuscript we show that the RT-LAMP reaction has a sensitivity of only 200 RNA virus copies, with a color change from pink to yellow occurring in 100% of the 62 clinical samples tested positive by RT-qPCR. We also demonstrated that this reaction is 100% specific for SARS-CoV-2 after testing 57 clinical samples infected with dozens of different respiratory viruses and 74 individuals without any viral infection. Although the majority of manuscripts recently published using this technique describe only the presence of two-color states (pink = negative and yellow = positive), we verified by naked-eye and absorbance measurements that there is an evident third color cluster (orange), in general related to positive samples with low viral loads, but which cannot be defined as positive or negative by the naked eye. Orange colors should be repeated or tested by RT-qPCR to avoid a false diagnostic. RT-LAMP is therefore very reliable for samples with a RT-qPCR Ct < 30 being as sensitive and specific as a RT-qPCR test. All reactions were performed in 30 min at 65 °C. The use of reaction time longer than 30 min is also not recommended since nonspecific amplifications may cause false positives.


Asunto(s)
COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/metabolismo , SARS-CoV-2/genética , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19 , Colorimetría , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa , SARS-CoV-2/aislamiento & purificación , Carga Viral
19.
Anal Chim Acta ; 1166: 338548, 2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34022998

RESUMEN

Human immunodeficiency virus (HIV) is still considered a pandemic, and the detection of p24-HIV protein has an important role in the early diagnosis of HIV in adults and newborns. The accessibility of these trials depends on the price and execution difficulty of the method, which can be reduced using electrochemical methods by using enzymeless approaches, disposable and accurate devices. In this work, graphene quantum dots were acquired by a simple synthesis and employed as an electrochemical signal amplifier and support for the aptamer immobilization through a feasible and stable modification of disposable screen-printed electrodes. The device has been easily assembled and used to detect p24-HIV protein without the interference of similar proteins or sample matrix. Using the best set of experimental conditions, a linear correlation between analytical signal and log of p24-HIV concentration from 0.93 ng mL-1 to 93 µg mL-1 and a limit of detection of 51.7 pg mL-1 were observed. The developed device was applied to p24 determination in spiked human serum and provided distinct levels of signal for positive and negative samples, successfully identifying real samples with the target protein. This sensor is a step towards the development of point-of-care devices and the popularization of electrochemical methods for trials and diagnostics of relevant diseases.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Grafito , Infecciones por VIH , Puntos Cuánticos , Adulto , Técnicas Electroquímicas , Electrodos , Infecciones por VIH/diagnóstico , Proteínas del Virus de la Inmunodeficiencia Humana , Humanos , Recién Nacido , Límite de Detección
20.
Electrophoresis ; 31(15): 2469-86, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20665910

RESUMEN

Over the last years, there has been an explosion in the number of developments and applications of CE and microchip-CE. In part, this growth has been the direct consequence of recent developments in instrumentation associated with CE. This review, which is focused on the contributions published in the last 5 years, is intended to complement the articles presented in this special issue dedicated to instrumentation and to provide an overview of the general trends and some of the most remarkable developments published in the areas of high-voltage power supplies, detectors, auxiliary components, and compact systems. It also includes a few examples of alternative uses of and modifications to traditional CE instruments.


Asunto(s)
Electroforesis Capilar/instrumentación , Electroforesis Capilar/tendencias , Electroforesis por Microchip/instrumentación , Electroforesis por Microchip/tendencias , Diseño de Equipo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA