RESUMEN
INTRODUCTION: High-molecular-weight (HMW) von Willebrand factor (VWF) multimer deficiency occurs in classical low-flow, low-gradient (LF/LG) aortic stenosis (AS) due to shear force-induced proteolysis. The prognostic value of HMW VWF multimer deficiency is unknown. Therefore, we sought to evaluate the impact of HMW VWF multimer deficiency on clinical outcome. METHODS: In this prospective research study, a total of 83 patients with classical LF/LG AS were included. All patients underwent dobutamine stress echocardiography to distinguish true-severe (TS) from pseudo-severe (PS) classical LF/LG AS. HMW VWF multimer ratio was calculated using densitometric Western blot band quantification. The primary endpoint was all-cause mortality. RESULTS: Mean age was 79 ± 9 years, and TS classical LF/LG AS was diagnosed in 73% (n = 61) and PS classical LF/LG AS in 27% (n = 22) of all patients. Forty-six patients underwent aortic valve replacement (AVR) and 37 were treated conservatively. During a mean follow-up of 27 ± 17 months, 47 deaths occurred. Major bleeding complications after AVR (10/46; 22%) were more common in patients with HMW VWF multimer ratio <1 (8/17; 47%) in comparison to patients with a normal multimer pattern (2/29; 7%) at baseline (p = 0.003). In a multivariable Cox regression analysis, HMW VWF multimer deficiency was a predictor of all-cause mortality (HR: 3.02 [95% CI: 1.31-6.96], p = 0.009) in the entire cohort. This association was driven by higher mortality rates in the AVR group (multivariable-adjusted HR: 9.4; 95% CI 2.0-43.4, p = 0.004). CONCLUSIONS: This is the first study to demonstrate the predictive value of HMW VWF multimer ratio for risk stratification in patients with classical LF/LG AS. HMW VWF multimer deficiency was associated with an increased risk of all-cause mortality and major bleeding complications after AVR.
RESUMEN
Models of the human body representing digital twins of patients have attracted increasing interest in clinical research for the delivery of personalized diagnoses and treatments to patients. For example, noninvasive cardiac imaging models are used to localize the origin of cardiac arrhythmias and myocardial infarctions. The precise knowledge of a few hundred electrocardiogram (ECG) electrode positions is essential for their diagnostic value. Smaller positional errors are obtained when extracting the sensor positions, along with the anatomical information, for example, from X-ray Computed Tomography (CT) slices. Alternatively, the amount of ionizing radiation the patient is exposed to can be reduced by manually pointing a magnetic digitizer probe one by one to each sensor. An experienced user requires at least 15 min. to perform a precise measurement. Therefore, a 3D depth-sensing camera system was developed that can be operated under adverse lighting conditions and limited space, as encountered in clinical settings. The camera was used to record the positions of 67 electrodes attached to a patient's chest. These deviate, on average, by 2.0 mm ±1.5 mm from manually placed markers on the individual 3D views. This demonstrates that the system provides reasonable positional precision even when operated within clinical environments.
Asunto(s)
Tórax , Tomografía Computarizada por Rayos X , Humanos , Electrodos , Tomografía Computarizada por Rayos X/métodos , Electrocardiografía/métodos , Imagenología Tridimensional/métodosRESUMEN
Background: Patients with severe aortic valve stenosis (AS) frequently present with pulmonary hypertension (PH). The gold standard for detection of pulmonary hypertension is right heart catheterization, which is not routinely performed as a preoperative standard in cardiology centers today, neither before surgical valve replacement nor before transcatheter aortic valve replacement (TAVR) procedure. Echocardiographic determination of systolic pulmonary artery pressure (sPAP) provides an opportunity to assess the presence or absence of PH. The aim of the present study was to investigate the extent to which plasma levels of common cardiovascular biomarkers behave in patients with severe AS and an sPAP < 40 mmHg in comparison to patients with an sPAP ≥ 40 mmHg. Methods: 179 patients with echocardiographic evidence of severe AS before TAVR procedure were divided into 2 groups based on sPAP. An sPAP of 40 mmHg was considered the cut-off value, with absence of PH defined by an sPAP < 40 mmHg (n = 82) and presence of PH defined by an sPAP ≥ 40 mmHg (n = 97). Directly before TAVR, a blood sample was drawn from each patient, and plasma concentrations of the cardiovascular biomarkers Soluble Suppression of Tumorigenicity-2 (sST2), Growth/Differentiation of Factor-15 (GDF-15), Heart-Type Fatty-Acid Binding Protein (H-FABP), Insulin Like Growth Factor Binding Protein 2 (IGF-BP2), Soluble Urokinase-Type Plasminogen Activator Receptor (suPAR), Brain Natriuretic Peptide (BNP) and Cardiac Troponin I (cTnI) were determined. Results: Patients with an sPAP ≥ 40 mmHg had significantly higher sST2 (p = 0.010), GDF-15 (p = 0.005), IGF-BP2 (p = 0.029), suPAR (p = 0.018), BNP (p < 0.001) and cTnI (p = 0.039) plasma levels. Only for H-FABP (p = 0.069), no significant differences were discernible between the two groups. In addition, cut-off values were calculated to predict an sPAP ≥ 40 mmHg. Significant results were shown with 16045.84 pg/mL for sST2 (p = 0.010), with 1117.54 pg/mL for GDF-15 (p = 0.005), with 107028.43 pg/mL for IGF-BP2 (p = 0.029), with 3782.84 pg/mL for suPAR (p = 0.018), with 2248.00 pg/mL for BNP (p < 0.001) and with 20.50 pg/mL for cTnI (p = 0.002). Conclusions: sPAP as an echocardiographic parameter in combination with supplementary use of cardiovascular biomarkers presented here have the potential to provide more detailed information about the presence or absence of PH in a non-invasive way.
RESUMEN
BACKGROUND: Temporary transvenous pacing in critically ill patients requiring prolonged cardiac pacing is associated with a high risk of complications. We sought to evaluate the safety and efficacy of self-contained intracardiac leadless pacemaker (LPM) implantation in this population. METHODS AND RESULTS: Consecutive patients implanted with a Micra LPM during the hospitalization in an intensive care unit were retrospectively included. Inclusion criteria were: more than or equal to 1 supracaval central venous line, or a ventilation tube, or intravenous antibiotic therapy for ongoing sepsis or bacteremia. Patients with a history of the previous implantation of a pacemaker were excluded. Out of 1016 patients implanted with an LPM, 99 met the inclusion criteria. Mean age was 75 years and Charlson comorbidity index 7. LPM implantation was successfully performed in 98% of cases, with a perioperative complication rate of 5%, mainly cardiac injuries. In-hospital mortality rate was 6%. No late (>30 days) device-related complication occurred, especially no infection. CONCLUSIONS: LPM appears as an acceptable alternative to conventional temporary transvenous pacing in selected critically ill patients requiring prolonged cardiac pacing, especially regarding the risk of infection.
Asunto(s)
Enfermedad Crítica , Marcapaso Artificial , Anciano , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Diseño de Equipo , Humanos , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND AND AIMS: Oral anticoagulation is effective for stroke prevention in atrial fibrillation (AF). However, strokes may still occur in high-risk individuals. We conducted a prospective trial to assess the association between adipocytokine serum levels and surrogate parameters for thromboembolic events. METHODS AND RESULTS: In this cross-sectional multicenter trial, we enrolled 189 patients with AF who were on oral anticoagulation. The primary endpoint was defined as either the presence of spontaneous echo contrast (SEC), a left atrial appendage (LAA), or a left atrial (LA) thrombus on transesophageal echocardiography. We investigated the association of adipocytokine serum levels with the combined endpoint using logistic regression analysis. Forty-eight individuals (25%) were assigned to group 1 (G1) due to the occurrence of at least one of the components of the combined endpoint (41 [21.7%] SEC, 3 [1.6%] LA thrombus, 13 [6.9%] LAA thrombus), whereas the remaining patients formed group 2 (G2). The BMI, logarithmized (loge) leptin (G1: 2.0 ± 1.3 µg/ml, G2: 2.0 ± 1.1 µg/ml, p = 0.746) and visfatin serum levels (G1: 3.4 ± 0.3 ng/ml, G2: 3.4 ± 0.5 ng/ml, p = 0.900) did not significantly differ between the groups. Conversely, logarithmized adiponectin (G1: 3.3 ± 0.6 ng/ml, G2: 3.1 ± 0.7 ng/ml, p = 0.036) and resistin levels (G1: 1.8 ± 0.5 ng/ml, G2: 1.6 ± 0.5 ng/ml, p = 0.009) were higher in patients with the primary endpoint. Multivariate logistic regression analysis using a score that combined the individual adiponectin and resistin values in each patient corroborated this association. CONCLUSIONS: Our results suggest that adiponectin and resistin may act as potential biomarkers to identify individuals with AF who are at high thromboembolic risk.
Asunto(s)
Adipoquinas/sangre , Anticoagulantes/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/prevención & control , Tromboembolia/prevención & control , Trombosis/prevención & control , Adiponectina/sangre , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Fibrilación Atrial/sangre , Fibrilación Atrial/diagnóstico por imagen , Biomarcadores/sangre , Índice de Masa Corporal , Estudios Transversales , Citocinas/sangre , Ecocardiografía Transesofágica , Femenino , Alemania , Humanos , Leptina/sangre , Masculino , Persona de Mediana Edad , Nicotinamida Fosforribosiltransferasa/sangre , Estudios Prospectivos , Resistina/sangre , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/sangre , Accidente Cerebrovascular/diagnóstico , Tromboembolia/sangre , Tromboembolia/diagnóstico , Trombosis/sangre , Trombosis/diagnóstico por imagen , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Systemic inflammation has been identified as a major cardiovascular risk factor in patients undergoing transcatheter aortic valve replacement (TAVR), yet currently, it is not adequately portrayed in scores for pre-interventional risk assessment. The aim of this study was to investigate the predictive ability of TNF-α in TAVR. METHODS: A total of 431 patients undergoing transfemoral TAVR were enrolled in this study. Blood samples were drawn prior to intervention, 24 h post-intervention, 4, 5, and 7 days post-intervention, and 1, 3, and 6 months post-TAVR. RESULTS: In a univariate Cox proportional hazard analysis, plasma concentrations of TNF-α after 24 h and after 5 days were associated with mortality after 12 months (after 24 h: HR 1.002 (1.000-1.004), p = 0.028; after 5d: HR 1.003 (1.001-1.005), p = 0.013). This association remained significant even after correction for confounders in a multivariate Cox regression analysis. Additionally, cut-offs were calculated. Patients above the cut-off for TNF-α after 5d had a significantly worse 12-month mortality than patients below the cut-off (18.8% vs. 2.8%, p = 0.046). CONCLUSION: Plasma levels of TNF-α after 24 h and 5 days were independently associated with 12-month mortality in patients undergoing TAVR. Thus, TNF-α could represent a novel biomarker for enhanced risk stratification in these patients.
Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Factor de Necrosis Tumoral alfa/sangre , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Humanos , Inflamación , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidadRESUMEN
AIMS: Atrial fibrillation (AF) is the most prevalent arrhythmia in western countries. It is associated with increased mortality and morbidity and responsible for hospitalization rates of 10-40% per patient per year. Studies from the UK and the USA have shown that AF is responsible for â¼1% of the total healthcare expenditures in these countries. The only potentially curative treatment is pulmonary vein isolation (PVI). Published health economic data on the impact of PVI mainly consist of simulations of expenditures with assumed efficacy taken from ablation studies. Real expenditure data are missing as well as pre-ablation period data and long-term data. METHODS AND RESULTS: We analyse true healthcare expenditures based on inpatient and outpatient data from the Upper Austrian Health Insurance Fund social security system of patients undergoing PVI during 2005 to 2015. We identified 1135 patients undergoing PVI with 268 having multiple procedures. Days of hospitalization and days of sick leave started to rise in the year before ablation. PVI was able to lower both parameters to the level of 1 year before ablation. Comparing four quarters before and after a single-index ablation, a highly significant reduction in inpatient healthcare expenditures was documented. There was a significant, but numerically small increase in outpatient expenditures, resulting in a significant reduction in overall healthcare expenditures. CONCLUSION: Analysing a cohort of the Upper Austrian Health Insurance Fund undergoing PVI, we found significant cost-saving effects on post-interventional healthcare expenditures and a reduction in days of sick leave.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Gastos en Salud , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/economía , Fibrilación Atrial/cirugía , Austria , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del TratamientoRESUMEN
AIMS: As in vivo real-life data are still scarce, we conducted a study to assess the safety and feasibility of cardiac magnetic resonance imaging (MRI) in patients with a leadless pacemaker system. METHODS AND RESULTS: In this prospective non-randomized interventional trial, we enrolled 15 patients with an MRI conditional Micra® leadless pacemaker system to undergo either a 1.5 T or 3.0 T cardiac MRI scan. Clinical adverse events as well as device parameters such as pacing threshold, sensing, impedance, and battery life were assessed at baseline as well as 1 and 3 months after the scan. Device parameter changes between different time points were tested for statistical significance and compared with pre-set cut-off values. Fourteen patients underwent the cardiac MRI scan according to the protocol as well as the scheduled follow-up visits. One participant was excluded from analysis, as the MRI scan was not possible because of severe claustrophobia. Other clinical events did not occur during the scan and the follow-up period. Device parameters stayed stable and changes during the observational period were statistically not significant (changes vs. baseline: pacing threshold: 0.01 ± 0.05 V, P = 0.308, 0.01 ± 0.07 V, P = 0.419, sensing: -0.15 ± 1.11 mV, P = 0.658, -0.19 ± 1.17 mV, P = 0.800, impedance: -7.86 ± 30.7 Ohm, P = 0.447, -7.86 ± 25.77 Ohm, P = 0.183, at 1 and 3 months follow-up, respectively). Parameter changes were not statistically different between patients who underwent imaging at 1.5 T (n = 7) or 3.0 T (n = 7). CONCLUSION: In our set of patients with a Micra® leadless pacemaker, cardiac magnetic resonance imaging at either 1.5 T or 3.0 T proved feasible and safe with no relevant changes in device parameters within 3 months of follow-up.
Asunto(s)
Estimulación Cardíaca Artificial , Imagen por Resonancia Magnética , Marcapaso Artificial , Adulto , Anciano , Anciano de 80 o más Años , Austria , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Magnética/efectos adversos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Falla de Prótesis , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Factores de TiempoRESUMEN
BACKGROUND: Randomized controlled trials (RCTs) have yielded conflicting results regarding the ability of beta-blockers to influence perioperative cardiovascular morbidity and mortality. Thus routine prescription of these drugs in unselected patients remains a controversial issue. A previous version of this review assessing the effectiveness of perioperative beta-blockers in cardiac and non-cardiac surgery was last published in 2018. The previous review has now been split into two reviews according to type of surgery. This is an update and assesses the evidence in cardiac surgery only. OBJECTIVES: To assess the effectiveness of perioperatively administered beta-blockers for the prevention of surgery-related mortality and morbidity in adults undergoing cardiac surgery. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, CINAHL, Biosis Previews and Conference Proceedings Citation Index-Science on 28 June 2019. We searched clinical trials registers and grey literature, and conducted backward- and forward-citation searching of relevant articles. SELECTION CRITERIA: We included RCTs and quasi-randomized studies comparing beta-blockers with a control (placebo or standard care) administered during the perioperative period to adults undergoing cardiac surgery. We excluded studies in which all participants in the standard care control group were given a pharmacological agent that was not given to participants in the intervention group, studies in which all participants in the control group were given a beta-blocker, and studies in which beta-blockers were given with an additional agent (e.g. magnesium). We excluded studies that did not measure or report review outcomes. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed studies for inclusion, extracted data, and assessed risks of bias. We assessed the certainty of evidence with GRADE. MAIN RESULTS: We included 63 studies with 7768 participants; six studies were quasi-randomized and the remaining were RCTs. All participants were undergoing cardiac surgery, and in most studies, at least some of the participants were previously taking beta-blockers. Types of beta-blockers were: propranolol, metoprolol, sotalol, esmolol, landiolol, acebutolol, timolol, carvedilol, nadolol, and atenolol. In twelve studies, beta-blockers were titrated according to heart rate or blood pressure. Duration of administration varied between studies, as did the time at which drugs were administered; in nine studies this was before surgery, in 20 studies during surgery, and in the remaining studies beta-blockers were started postoperatively. Overall, we found that most studies did not report sufficient details for us to adequately assess risk of bias. In particular, few studies reported methods used to randomize participants to groups. In some studies, participants in the control group were given beta-blockers as rescue therapy during the study period, and all studies in which the control was standard care were at high risk of performance bias because of the open-label study design. No studies were prospectively registered with clinical trials registers, which limited the assessment of reporting bias. We judged 68% studies to be at high risk of bias in at least one domain.Study authors reported few deaths (7 per 1000 in both the intervention and control groups), and we found low-certainty evidence that beta-blockers may make little or no difference to all-cause mortality at 30 days (risk ratio (RR) 0.95, 95% confidence interval (CI) 0.47 to 1.90; 29 studies, 4099 participants). For myocardial infarctions, we found no evidence of a difference in events (RR 1.05, 95% CI 0.72 to 1.52; 25 studies, 3946 participants; low-certainty evidence). Few study authors reported cerebrovascular events, and the evidence was uncertain (RR 1.37, 95% CI 0.51 to 3.67; 5 studies, 1471 participants; very low-certainty evidence). Based on a control risk of 54 per 1000, we found low-certainty evidence that beta-blockers may reduce episodes of ventricular arrhythmias by 32 episodes per 1000 (RR 0.40, 95% CI 0.25 to 0.63; 12 studies, 2296 participants). For atrial fibrillation or flutter, there may be 163 fewer incidences with beta-blockers, based on a control risk of 327 incidences per 1000 (RR 0.50, 95% CI 0.42 to 0.59; 40 studies, 5650 participants; low-certainty evidence). However, the evidence for bradycardia and hypotension was less certain. We found that beta-blockers may make little or no difference to bradycardia (RR 1.63, 95% CI 0.92 to 2.91; 12 studies, 1640 participants; low-certainty evidence), or hypotension (RR 1.84, 95% CI 0.89 to 3.80; 10 studies, 1538 participants; low-certainty evidence).We used GRADE to downgrade the certainty of evidence. Owing to studies at high risk of bias in at least one domain, we downgraded each outcome for study limitations. Based on effect size calculations in the previous review, we found an insufficient number of participants in all outcomes (except atrial fibrillation) and, for some outcomes, we noted a wide confidence interval; therefore, we also downgraded outcomes owing to imprecision. The evidence for atrial fibrillation and length of hospital stay had a moderate level of statistical heterogeneity which we could not explain, and we, therefore, downgraded these outcomes for inconsistency. AUTHORS' CONCLUSIONS: We found no evidence of a difference in early all-cause mortality, myocardial infarction, cerebrovascular events, hypotension and bradycardia. However, there may be a reduction in atrial fibrillation and ventricular arrhythmias when beta-blockers are used. A larger sample size is likely to increase the certainty of this evidence. Four studies awaiting classification may alter the conclusions of this review.
Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Procedimientos Quirúrgicos Cardíacos , Atención Perioperativa/métodos , Antagonistas Adrenérgicos beta/efectos adversos , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/prevención & control , Bradicardia/inducido químicamente , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Trastornos Cerebrovasculares/mortalidad , Trastornos Cerebrovasculares/prevención & control , Humanos , Hipotensión/inducido químicamente , Hipotensión/mortalidad , Hipotensión/prevención & control , Morbilidad , Infarto del Miocardio/mortalidad , Infarto del Miocardio/prevención & control , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/prevención & control , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/prevención & control , Ensayos Clínicos Controlados Aleatorios como AsuntoRESUMEN
BACKGROUND: Randomized controlled trials (RCTs) have yielded conflicting results regarding the ability of beta-blockers to influence perioperative cardiovascular morbidity and mortality. Thus routine prescription of these drugs in an unselected population remains a controversial issue. A previous version of this review assessing the effectiveness of perioperative beta-blockers in cardiac and non-cardiac surgery was last published in 2018. The previous review has now been split into two reviews according to type of surgery. This is an update, and assesses the evidence in non-cardiac surgery only. OBJECTIVES: To assess the effectiveness of perioperatively administered beta-blockers for the prevention of surgery-related mortality and morbidity in adults undergoing non-cardiac surgery. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, CINAHL, Biosis Previews and Conference Proceedings Citation Index-Science on 28 June 2019. We searched clinical trials registers and grey literature, and conducted backward- and forward-citation searching of relevant articles. SELECTION CRITERIA: We included RCTs and quasi-randomized studies comparing beta-blockers with a control (placebo or standard care) administered during the perioperative period to adults undergoing non-cardiac surgery. If studies included surgery with different types of anaesthesia, we included them if 70% participants, or at least 100 participants, received general anaesthesia. We excluded studies in which all participants in the standard care control group were given a pharmacological agent that was not given to participants in the intervention group, studies in which all participants in the control group were given a beta-blocker, and studies in which beta-blockers were given with an additional agent (e.g. magnesium). We excluded studies that did not measure or report review outcomes. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed studies for inclusion, extracted data, and assessed risks of bias. We assessed the certainty of evidence with GRADE. MAIN RESULTS: We included 83 RCTs with 14,967 participants; we found no quasi-randomized studies. All participants were undergoing non-cardiac surgery, and types of surgery ranged from low to high risk. Types of beta-blockers were: propranolol, metoprolol, esmolol, landiolol, nadolol, atenolol, labetalol, oxprenolol, and pindolol. In nine studies, beta-blockers were titrated according to heart rate or blood pressure. Duration of administration varied between studies, as did the time at which drugs were administered; in most studies, it was intraoperatively, but in 18 studies it was before surgery, in six postoperatively, one multi-arm study included groups of different timings, and one study did not report timing of drug administration. Overall, we found that more than half of the studies did not sufficiently report methods used for randomization. All studies in which the control was standard care were at high risk of performance bias because of the open-label study design. Only two studies were prospectively registered with clinical trials registers, which limited the assessment of reporting bias. In six studies, participants in the control group were given beta-blockers as rescue therapy during the study period.The evidence for all-cause mortality at 30 days was uncertain; based on the risk of death in the control group of 25 per 1000, the effect with beta-blockers was between two fewer and 13 more per 1000 (risk ratio (RR) 1.17, 95% confidence interval (CI) 0.89 to 1.54; 16 studies, 11,446 participants; low-certainty evidence). Beta-blockers may reduce the incidence of myocardial infarction by 13 fewer incidences per 1000 (RR 0.72, 95% CI 0.60 to 0.87; 12 studies, 10,520 participants; low-certainty evidence). We found no evidence of a difference in cerebrovascular events (RR 1.65, 95% CI 0.97 to 2.81; 6 studies, 9460 participants; low-certainty evidence), or in ventricular arrhythmias (RR 0.72, 95% CI 0.35 to 1.47; 5 studies, 476 participants; very low-certainty evidence). Beta-blockers may reduce atrial fibrillation or flutter by 26 fewer incidences per 1000 (RR 0.41, 95% CI 0.21 to 0.79; 9 studies, 9080 participants; low-certainty evidence). However, beta-blockers may increase bradycardia by 55 more incidences per 1000 (RR 2.49, 95% CI 1.74 to 3.56; 49 studies, 12,239 participants; low-certainty evidence), and hypotension by 44 more per 1000 (RR 1.40, 95% CI 1.29 to 1.51; 49 studies, 12,304 participants; moderate-certainty evidence).We downgraded the certainty of the evidence owing to study limitations; some studies had high risks of bias, and the effects were sometimes altered when we excluded studies with a standard care control group (including only placebo-controlled trials showed an increase in early mortality and cerebrovascular events with beta-blockers). We also downgraded for inconsistency; one large, well-conducted, international study found a reduction in myocardial infarction, and an increase in cerebrovascular events and all-cause mortality, when beta-blockers were used, but other studies showed no evidence of a difference. We could not explain the reason for the inconsistency in the evidence for ventricular arrhythmias, and we also downgraded this outcome for imprecision because we found few studies with few participants. AUTHORS' CONCLUSIONS: The evidence for early all-cause mortality with perioperative beta-blockers was uncertain. We found no evidence of a difference in cerebrovascular events or ventricular arrhythmias, and the certainty of the evidence for these outcomes was low and very low. We found low-certainty evidence that beta-blockers may reduce atrial fibrillation and myocardial infarctions. However, beta-blockers may increase bradycardia (low-certainty evidence) and probably increase hypotension (moderate-certainty evidence). Further evidence from large placebo-controlled trials is likely to increase the certainty of these findings, and we recommend the assessment of impact on quality of life. We found 18 studies awaiting classification; inclusion of these studies in future updates may also increase the certainty of the evidence.
Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Atención Perioperativa/métodos , Complicaciones Posoperatorias/prevención & control , Procedimientos Quirúrgicos Operativos/efectos adversos , Anestesia General/efectos adversos , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/prevención & control , Bradicardia/prevención & control , Causas de Muerte , Humanos , Hipotensión/mortalidad , Hipotensión/prevención & control , Morbilidad , Infarto del Miocardio/mortalidad , Infarto del Miocardio/prevención & control , Complicaciones Posoperatorias/mortalidad , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto , Procedimientos Quirúrgicos Operativos/mortalidadRESUMEN
BACKGROUND: Leadless pacemaker technology is a promising upcoming field in clinical rhythmology. Today, the most commonly used system in the clinical setting is the Micra™ leadless pacemaker system (Medtronic). In autopsies of patients who witnessed non-pacemaker associated death, unexpected ingrowth/encapsulation within the wall of the right ventricle was reported. The occurrence of a complete encapsulation was not expected and the process of endothelialisation remains unclear. We hypothesized, that a local inflammatory response might be the cause of these findings. The aim of our experimental in-vitro study was to investigate the effect of the Micra™ system and its single components on inflammatory processes. METHODS: For this purpose, whole Micra™ pacemakers were incubated in heparin plasma from 25 healthy volunteers for 48â¯h at 37⯰C. Furthermore, 1â¯g gold, steel, titanium, tungsten and nitinol wires were incubated in heparin plasma for 48â¯h at 37⯰C as well (nâ¯=â¯10). To detect eventual inflammatory processes, interleukin- (IL) 1ß, IL-6, and tumor necrosis factor alpha (TNF-α), the chemokine IL-8 were measured using enzyme-linked immunosorbent assay (ELISA). Additionally, the level of transforming growth factor beta 1 (TGF-ß1) and vascular endothelial growth factor (VEGF) were analysed. RESULTS: ELISA analyses showed that the whole Micra system leads to a significant increase in the inflammatory cytokine IL-6 which correlates with the data gained by the incubation of whole blood with the different wires. In particular, 0.5â¯g of tungsten showed a significant rise of IL-6 which could also be found for IL-1ß and IL-8. CONCLUSIONS: The in vitro study of the Micra system showed that the material composition led to an onset of inflammatory processes in whole blood. Consequently, one may speculate that the composition of Micra pacemaker may have a local inflammatory, though subclinical, effects in patients implanted with a Micra™ pacemakers.
Asunto(s)
Endotelio Vascular , Marcapaso Artificial , Electrocardiografía , Diseño de Equipo , Humanos , Interleucinas , Prótesis e Implantes , Factor de Crecimiento Transformador beta1 , Factor A de Crecimiento Endotelial VascularRESUMEN
OBJECTIVE: Acute myocarditis is accompanied by an impaired coronary microcirculation. These microcirculatory disturbances are not well defined, and data are derived from complex invasive measurements. Therefore, this study aimed to evaluate the inflammation-induced microcirculatory dysfunction including its reversibility and association with markers of inflammation severity (extent of LGE on CMR imaging and laboratory markers of myocardial necrosis) using the noninvasive technique of echocardiographic CFR measurement. METHODS: Patients (n = 14) with clinically suspected acute myocarditis in the absence of coronary artery disease were prospectively enrolled, and echocardiographic CFR was determined by measuring peak diastolic coronary blood flow velocity at rest (PDV1) and under adenosine-induced hyperemia (PDV2) at baseline and 3-month follow-up. RESULTS: Eight of 14 (57.1%) patients showed an impaired baseline CFR (PDV2/PDV1 < 2). These patients were characterized by higher levels of cardiac troponin T (0.55 ± 0.39 vs 0.18 ± 0.08; P = 0.008) and larger areas of LGE on CMR. At 3-month follow-up, CFR was normal in all patients. CONCLUSION: A reversibly impaired coronary microcirculation is a frequent finding in acute myocarditis and is associated with markers of inflammation severity. Echocardiographic CFR measurement represents a feasible and safe method for its assessment.
Asunto(s)
Circulación Coronaria , Vasos Coronarios/fisiopatología , Microcirculación , Miocarditis/fisiopatología , Enfermedad Aguda , Velocidad del Flujo Sanguíneo , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía , Femenino , Humanos , Inflamación/fisiopatología , Masculino , Persona de Mediana Edad , Miocarditis/diagnóstico por imagen , Medición de RiesgoRESUMEN
BACKGROUND: Premature myocardial infarction (≤40 years) represents a rare disease with a distinct risk factor profile and a lipid phenotype that is characterized by a predominance of elevated triglyceride-rich lipoproteins. So far high-density and low-density lipoproteins remain the primary targets for risk stratification and treatment evaluation in coronary artery disease, but this strategy might be insensitive in patients with premature myocardial infarction. AIM: Aim of this study was to investigate the predictive value of different lipid fractions on long-term cardiovascular outcome in patients with premature myocardial infarction. METHODS: We prospectively enrolled 102 consecutive AMI survivors (≤40 years) in this prospective multicentre study and investigated the influence of the familial combined hypercholesterolaemia phenotype and a corresponding multimarker panel of different lipid fractions on cardiovascular outcome. RESULTS: Total cholesterol, non-HDL cholesterol, remnant cholesterol and Apo B lipoprotein were significantly higher in patients experiencing MACE as compared to those who did not. The familial combined hypercholesterolaemia phenotype was associated with an unfavourable cardiovascular outcome even after adjustment for potential cofounders (adjusted HR 3.04,95% CI, 1.26-7.34, P = 0.013). Remnant cholesterol revealed the strongest association with MACE (adj.HR 1.94, 95%CI. 1.30-2.99, P = 0.001). Interestingly LDL and HDL revealed no significant impact on cardiovascular outcome in this study cohort. CONCLUSION: Non-HDL and remnant cholesterol are strongly associated with an unfavourable outcome in patients with premature myocardial infarction and might be the preferred treatment target for lipid-lowering therapy.
Asunto(s)
Hiperlipoproteinemia Tipo II/complicaciones , Metabolismo de los Lípidos/fisiología , Infarto del Miocardio/sangre , Adulto , Apolipoproteínas B/metabolismo , Australia/epidemiología , Estudios de Casos y Controles , HDL-Colesterol/metabolismo , Femenino , Humanos , Hiperlipoproteinemia Tipo II/sangre , Hiperlipoproteinemia Tipo II/mortalidad , Masculino , Infarto del Miocardio/mortalidad , Estudios Prospectivos , Medición de RiesgoRESUMEN
BACKGROUND: There are limited data on patients with leadless cardiac pacemakers (LCP) undergoing magnetic resonance imaging. The aim of this prospective, single-center, observational study was to evaluate artefacts on cardiovascular magnetic resonance (CMR) images in patients with LCP. METHODS: Fifteen patients with Micra™ LCP, implanted at least 6 weeks prior to CMR scan, were enrolled and underwent either 1.5 Tesla or 3 Tesla CMR imaging. Artefacts were categorized into grade 1 (excellent image quality), grade 2 (good), grade 3 (poor) and grade 4 (non-diagnostic) for each myocardial segment. One patient was excluded because of an incomplete CMR investigation due to claustrophobia. RESULTS: LCP caused an arc-shaped artefact (0.99 ± 0.16 cm2) at the right ventricular (RV) apex. Of 224 analyzed myocardial segments of the left ventricle (LV) 158 (70.5%) were affected by grade 1, 27 (12.1%) by grade 2, 17 (7.6%) by grade 3 and 22 (9.8%) by grade 4 artefacts. The artefact burden of grade 3 and 4 artefacts was significantly higher in the 3 Tesla group (3 Tesla vs 1.5 Tesla: 3.7 ± 1.6 vs 1.9 ± 1.4 myocardial segments per patient, p = 0.03). A high artefact burden was particularly observed in the mid anteroseptal, inferoseptal and apical septal myocardial segments of the LV and in the mid and apical segments of the RV. Quantification of LV function and assessment of valves were feasible in all patients. We did not observe any clinical or device-related adverse events. CONCLUSION: CMR imaging in patients with LCP is feasible with excellent to good image quality in the majority of LV segments. The artefact burden is comparable small allowing an accurate evaluation of LV function, cardiac structures and valves. However, artefacts in the mid anteroseptal, inferoseptal and apical septal myocardial segments of the LV due to the LCP may impair or even exclude diagnostic evaluation of these segments. Artefacts on CMR images may be reduced by the use of 1.5 Tesla CMR scanners.
Asunto(s)
Artefactos , Corazón/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Marcapaso Artificial/efectos adversos , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Función Ventricular IzquierdaRESUMEN
BACKGROUND: Randomized controlled trials have yielded conflicting results regarding the ability of beta-blockers to influence perioperative cardiovascular morbidity and mortality. Thus routine prescription of these drugs in unselected patients remains a controversial issue. OBJECTIVES: The objective of this review was to systematically analyse the effects of perioperatively administered beta-blockers for prevention of surgery-related mortality and morbidity in patients undergoing any type of surgery while under general anaesthesia. SEARCH METHODS: We identified trials by searching the following databases from the date of their inception until June 2013: MEDLINE, Embase , the Cochrane Central Register of Controlled Trials (CENTRAL), Biosis Previews, CAB Abstracts, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Derwent Drug File, Science Citation Index Expanded, Life Sciences Collection, Global Health and PASCAL. In addition, we searched online resources to identify grey literature. SELECTION CRITERIA: We included randomized controlled trials if participants were randomly assigned to a beta-blocker group or a control group (standard care or placebo). Surgery (any type) had to be performed with all or at least a significant proportion of participants under general anaesthesia. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data from all studies. In cases of disagreement, we reassessed the respective studies to reach consensus. We computed summary estimates in the absence of significant clinical heterogeneity. Risk ratios (RRs) were used for dichotomous outcomes, and mean differences (MDs) were used for continuous outcomes. We performed subgroup analyses for various potential effect modifiers. MAIN RESULTS: We included 88 randomized controlled trials with 19,161 participants. Six studies (7%) met the highest methodological quality criteria (studies with overall low risk of bias: adequate sequence generation, adequate allocation concealment, double/triple-blinded design with a placebo group, intention-to-treat analysis), whereas in the remaining trials, some form of bias was present or could not be definitively excluded (studies with overall unclear or high risk of bias). Outcomes were evaluated separately for cardiac and non-cardiac surgery.CARDIAC SURGERY (53 trials)We found no clear evidence of an effect of beta-blockers on the following outcomes.⢠All-cause mortality: RR 0.73, 95% CI 0.35 to 1.52, 3783 participants, moderate quality evidence.⢠Acute myocardial infarction (AMI): RR 1.04, 95% CI 0.71 to 1.51, 3553 participants, moderate quality evidence.⢠Myocardial ischaemia: RR 0.51, 95% CI 0.25 to 1.05, 166 participants, low quality evidence.⢠Cerebrovascular events: RR 1.52, 95% CI 0.58 to 4.02, 1400 participants, low quality evidence.⢠Hypotension: RR 1.54, 95% CI 0.67 to 3.51, 558 participants, low quality evidence.⢠Bradycardia: RR 1.61, 95% CI 0.97 to 2.66, 660 participants, low quality evidence.⢠Congestive heart failure: RR 0.22, 95% CI 0.04 to 1.34, 311 participants, low quality evidence.Beta-blockers significantly reduced the occurrence of the following endpoints.⢠Ventricular arrhythmias: RR 0.37, 95% CI 0.24 to 0.58, number needed to treat for an additional beneficial outcome (NNTB) 29, 2292 participants, moderate quality evidence.⢠Supraventricular arrhythmias: RR 0.44, 95% CI 0.36 to 0.53, NNTB five, 6420 participants, high quality evidence.⢠On average, beta-blockers reduced length of hospital stay by 0.54 days (95% CI -0.90 to -0.19, 2450 participants, low quality evidence).NON-CARDIAC SURGERY (35 trials)Beta-blockers significantly increased the occurrence of the following adverse events.⢠All-cause mortality: RR 1.25, 95% CI 1.00 to 1.57, 11,413 participants, low quality of evidence, number needed to treat for an additional harmful outcome (NNTH) 167.⢠Hypotension: RR 1.50, 95% CI 1.38 to 1.64, NNTH 16, 10,947 participants, high quality evidence.⢠Bradycardia: RR 2.23, 95% CI 1.48 to 3.36, NNTH 21, 11,033 participants, moderate quality evidence.We found a potential increase in the occurrence of the following outcomes with the use of beta-blockers.⢠Cerebrovascular events: RR 1.59, 95% CI 0.93 to 2.71, 9150 participants, low quality evidence.Whereas no clear evidence of an effect was found when all studies were analysed, restricting the meta-analysis to low risk of bias studies revealed a significant increase in cerebrovascular events with the use of beta-blockers: RR 2.09, 95% CI 1.14 to 3.82, NNTH 265, 8648 participants.Beta-blockers significantly reduced the occurrence of the following endpoints.⢠AMI: RR 0.73, 95% CI 0.61 to 0.87, NNTB 76, 10,958 participants, high quality evidence.⢠Myocardial ischaemia: RR 0.51, 95% CI 0.34 to 0.77, NNTB nine, 978 participants, moderate quality evidence.⢠Supraventricular arrhythmias: RR 0.73, 95% CI 0.57 to 0.94, NNTB 112, 8744 participants, high quality evidence.We found no clear evidence of an effect of beta-blockers on the following outcomes.⢠Ventricular arrhythmias: RR 0.68, 95% CI 0.31 to 1.49, 476 participants, moderate quality evidence.⢠Congestive heart failure: RR 1.18, 95% CI 0.94 to 1.48, 9173 participants, moderate quality evidence.⢠Length of hospital stay: mean difference -0.45 days, 95% CI -1.75 to 0.84, 551 participants, low quality evidence. AUTHORS' CONCLUSIONS: According to our findings, perioperative application of beta-blockers still plays a pivotal role in cardiac surgery, as they can substantially reduce the high burden of supraventricular and ventricular arrhythmias in the aftermath of surgery. Their influence on mortality, AMI, stroke, congestive heart failure, hypotension and bradycardia in this setting remains unclear.In non-cardiac surgery, evidence shows an association of beta-blockers with increased all-cause mortality. Data from low risk of bias trials further suggests an increase in stroke rate with the use of beta-blockers. As the quality of evidence is still low to moderate, more evidence is needed before a definitive conclusion can be drawn. The substantial reduction in supraventricular arrhythmias and AMI in this setting seems to be offset by the potential increase in mortality and stroke.
Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Enfermedades Cardiovasculares/prevención & control , Complicaciones Posoperatorias/prevención & control , Procedimientos Quirúrgicos Operativos/efectos adversos , Antagonistas Adrenérgicos beta/efectos adversos , Anestesia General , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/prevención & control , Bradicardia/inducido químicamente , Enfermedades Cardiovasculares/inducido químicamente , Enfermedades Cardiovasculares/mortalidad , Procedimientos Quirúrgicos Cardiovasculares/efectos adversos , Procedimientos Quirúrgicos Cardiovasculares/mortalidad , Causas de Muerte , Trastornos Cerebrovasculares/mortalidad , Trastornos Cerebrovasculares/prevención & control , Humanos , Hipotensión/inducido químicamente , Hipotensión/mortalidad , Hipotensión/prevención & control , Infarto del Miocardio/mortalidad , Infarto del Miocardio/prevención & control , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/prevención & control , Complicaciones Posoperatorias/mortalidad , Ensayos Clínicos Controlados Aleatorios como Asunto , Procedimientos Quirúrgicos Operativos/mortalidadRESUMEN
BACKGROUND: Conventional pacemaker therapy is limited by short- and long-term complications, most notably device infection. Transcatheter pacing systems (TPS) may be beneficial in this kind of patients as they eliminate the need for a device pocket and leads and thus may reduce the risk of re-infection. METHODS: We assessed a novel procedure in 6 patients with severe device infection who were pacemaker dependent. After lead extraction a single chamber TPS was implanted into the right ventricle. RESULTS: Of the 6 patients who underwent lead extraction due to severe device infection at our institution, 3 were diagnosed with a pocket infection only, whereas the other 3 showed symptoms of both pocket and lead infection. Successful lead extraction and TPS implantation was accomplished in all patients. Four patients were bridged with a temporary pacemaker between 2 hours and 2 days after lead extraction, whereas 2 patients had the TPS implanted during the same procedure just before traditional pacemaker system removal. All patients stayed free of infection during the follow-up period of 12 weeks. An additional positron emission tomography scan was performed in each patient and indicated no signs of an infection around the TPS. CONCLUSION: Transcather pacemaker implantation was safe and feasible in 6 patients and did not result in re-infection even if implanted before removal of the infected pacemaker system within the same procedure. Therefore, implantation of a TPS may be an option for patients with severe device infection, especially in those with blocked venous access or who are pacemaker dependent.
Asunto(s)
Estimulación Cardíaca Artificial , Remoción de Dispositivos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis/instrumentación , Infecciones Relacionadas con Prótesis/cirugía , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Inflammatory responses are pivotal in the initiation and development of premature atherosclerotic lesions. Galectin-3 represents a valuable biomarker for both progression and destabilization of atherosclerotic lesions. This study aims to assess the involvement of galectin-3 in premature myocardial infarction. DESIGN: In this multicentre case-control study, we assessed circulating galectin-3 levels in 144 patients comprising 72 consecutive survivors of acute myocardial infarction (≤ 40 years) and 72 hospital controls frequency matched for age, gender and centre. RESULTS: Patients with acute myocardial infarction showed significantly higher galectin-3 levels as compared to controls in the acute phase of acute myocardial infarction (2552 ± 1992 vs. 1666 ± 829 pg/mL; P < 0·001) as well as in the stable phase 1 year after the index event (3692 ± 1774 vs. 1666 ± 829 pg/mL; P < 0·001). Circulating galectin-3 was significantly and independently associated with premature myocardial infarction in the logistic regression analysis (acute phase: adj. OR per 1-SD change 2·03, 95% CI 1·30-3·19; P = 0·002; stable phase: adj. OR of 6·54 (95% CI 2·56-16·68; P < 0·001). Moreover, we observed a significant correlation between circulating galectin-3 and leucocyte count (r = 0·35, P < 0·001), non-HDL cholesterol (r = 0·23, P = 0·014) and HDL cholesterol (r = -0·29, P = 0·002). CONCLUSION: We demonstrated that elevated levels of circulating galectin-3 are strongly associated with premature myocardial infarction. Galectin-3 might serve as link between dyslipidaemia as driving force of plaque formation with inflammation as initiator of plaque rupture in patients with premature acute myocardial infarction.
Asunto(s)
Dislipidemias/sangre , Galectina 3/sangre , Infarto del Miocardio/sangre , Placa Aterosclerótica/sangre , Adulto , Biomarcadores , Proteínas Sanguíneas , Estudios de Casos y Controles , Colesterol/sangre , HDL-Colesterol/sangre , LDL-Colesterol/sangre , Comorbilidad , Diabetes Mellitus/epidemiología , Dislipidemias/epidemiología , Femenino , Galectinas , Humanos , Hipertensión/epidemiología , Recuento de Leucocitos , Lipasa/sangre , Modelos Logísticos , Masculino , Infarto del Miocardio/epidemiología , Fumar/epidemiologíaRESUMEN
BACKGROUND: The aim of this study was to evaluate the safety and efficacy of the Lumax 740(®) Implantable Cardioverter Defibrillator (ICD) system in patients undergoing a defined 1.5 Tesla (T) MRI. MATERIALS AND METHODS: Between November 2013 and April 2014, eighteen patients (age range, 41-78 years; mean age, 64 years) implanted with a Lumax 740(®) ICD system for at least 6 weeks before an MRI were enrolled into this single-center feasibility study. The local ethics committee approved the study before patients gave written informed consent. Patients underwent defined MRI 1.5T of the brain and lower lumbar spine with three safety follow-up evaluations obtained during the 3-month study period. Data were analyzed descriptively. Study endpoints were the absence of either MRI and pacing system related serious adverse device effects (SADE), or of a ventricular pacing threshold increase >0.5V, or of an R-wave amplitude attenuation < 50%, or of an R-wave amplitude < 5.0 mV at 1-month follow-up. The assessment of safety and efficacy was supported by recording of all adverse events, changes in pacing threshold, R-wave sensing, pacing impedances and in battery status. RESULTS: Sixteen patients completed the MRI and the follow-up period. As no SADE occurred, the SADE free rate was 100%. Freedom from ventricular pacing threshold increase was 100% (16/16; 95%CI: 82.9%; 100.0%). There were no significant differences between baseline and follow-up measurements of sensing amplitudes (-0.58 ± 2.07 mV, P = 0.239, -0.41 ± 1.04 mV, P = 0.133, and -0.25 ± 1.36 mV, P = 0.724, for immediately after, 1 month and 3 months after MRI scan, respectively) and pacing thresholds (-0.047 ± 0.18 V, P = 0.317, -0.019 ± 0.11 V, P = 0.490, and 0.075 ± 0.19 V, P = 0.070, for immediately after, 1 month and 3 months after MRI scan, respectively). Lead impedances after the MRI scan were significantly lower as compared with baseline values (-22.8 ± 21.69 Ω, P = 0.001, -21.62 ± 39.71 Ω, P = 0.040, and -33.68 ± 57.73 Ω, P = 0.018, for immediately after, 1 month and 3 months after MRI scan, respectively). CONCLUSION: MRI scans in patients with MRI conditional ICD system (Lumax 740(®) ) are feasible and can be performed safely under defined conditions in a hospital setting.