Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Arthroplasty ; 26(6): 972-5, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21130599

RESUMEN

At 10 years, we reported survivorship of the Omnifit hydroxyapatite-coated femoral stem and the Omnifit-PSL porous-coated dual-radius acetabular shell (Stryker, Mahwah, NJ) with polyethylene liners sterilized by gamma radiation in air. Our 15-year follow-up examines survivorship and functional outcomes of this system. Ninety-two patients (98 hips) were identified from our database who had been involved with the prior study. The mean follow-up was 14.7 years (range, 11.8-17.0 years). Survival of the stem and cup was 98.8% and 69%, respectively. Osteolysis was seen in 56% of the proximal femur and 5% of the distal femur. This hydroxyapatite-coated stem continues to perform well at 15 years despite poor acetabular results. The performance of this acetabular component is consistent with previous literature.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera/instrumentación , Durapatita , Fémur , Prótesis de Cadera , Falla de Prótesis , Acetábulo/cirugía , Adulto , Anciano , Femenino , Fémur/cirugía , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Estimación de Kaplan-Meier , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Osteólisis/diagnóstico por imagen , Osteólisis/epidemiología , Prevalencia , Radiografía
2.
J Arthroplasty ; 25(2): 319-24, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19062247

RESUMEN

This study proposes a novel method for reattachment of the trochanteric slide osteotomy. The strength of this new fixation system was compared to established configurations. Fifteen sawbone femurs were used. Our configuration used cables above and below the lesser trochanter with a third cable around the shaft of the femur while passing the loose ends through the inferior hole of the cable grip. Displacement of the trochanter was measured with increasing load. Force required for catastrophic failure was also measured. The 3-cable construct resulted in significantly less displacement with increasing load and required a larger force to cause failure (1 cm and 2 cm). We theorize that our configuration produces a biomechanically stronger construct than previously used methods.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Osteotomía/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Humanos , Inestabilidad de la Articulación/prevención & control , Osteotomía/instrumentación , Reoperación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA