Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Biosens Bioelectron ; 55: 278-84, 2014 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-24389391

RESUMEN

Label-free affinity biosensors offer a promising platform for the development of a new generation of medical diagnostic technologies. Nevertheless, when such sensors are used in complex biological media, adsorption of non-targeted medium components prevents the specific detection of the analyte. In this work, we introduce for the first time a biosensor assay based on surface plasmon resonance (SPR) capable of diagnosing different stages of Epstein-Barr virus (EBV) infections in clinical serum samples. This was achieved by simultaneous detection of the antibodies against three different antigens present in the virus. To prevent the interference of the fouling from serum during the measurement, the SPR chips were coated by an antifouling layer of a polymer brush of poly[oligo(ethylene glycol) methacrylate] grown by surface-initiated atom transfer radical polymerization. The bioreceptors were then attached via hybridization of complementary oligonucleotides. This allowed the sensor surface to be regenerated after measurement by disrupting the complementary pairs above the oligonucleotides' melting temperature and attaching new bioreceptors. In this way, the same sensing surface could be used repeatedly. The procedure used in this work will serve as a prototype strategy for the development of label-free affinity biosensors for diagnostics in blood serum or plasma samples. This is the first example of detection of marker of a disease in clinical serum samples by an optical affinity biosensor.


Asunto(s)
Anticuerpos Antivirales/inmunología , Técnicas Biosensibles/instrumentación , Infecciones por Virus de Epstein-Barr/sangre , Infecciones por Virus de Epstein-Barr/diagnóstico , Inmunoensayo/instrumentación , Resonancia por Plasmón de Superficie/instrumentación , Infecciones por Virus de Epstein-Barr/inmunología , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Talanta ; 84(3): 867-73, 2011 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-21482295

RESUMEN

Competitive inhibition serological assay for detection of the phytoestrogen glycitein (Glyc) was developed using surface plasmon resonance (SPR) technique with protein conjugates and polyclonal antibodies initially designed for the enzyme-linked immunosorbent assays (ELISA). The efficiency of the approach to the quantification of the soy isoflavone glycitein in water was investigated using the competitive reaction of analyte (free Glyc)and immobilized Glyc-BSA-conjugate with polyclonal antibodies. It was shown that the efficiency to detect Glyc drastically depends on the pH level of the probe solution. With the decrease in pH from 7.4 to 4.0, (i) the affinity of the specific reaction increases and (ii) the level of unspecific sorption becomes saturated. Non-specific adsorption to a SPR sensor surface obscures the specific component and shaded specific response at higher pH (6.0-7.4) when used serum for the quantification of specific analytes. The standard curves obtained in acidic solutions (pH 4-5) indicate that the linear part of the dependence completely covers the range between detection limit (0.1 µg/ml) and Glyc solubility in water (0.9 µg/ml). The difference in SPR- and ELISA-based analytical protocols as well as the requirements for increasing the efficiency in quantitative SPR analysis using purified antibodies is discussed.


Asunto(s)
Sueros Inmunes , Isoflavonas/química , Albúmina Sérica Bovina/química , Resonancia por Plasmón de Superficie/métodos , Concentración de Iones de Hidrógeno , Isoflavonas/inmunología , Albúmina Sérica Bovina/inmunología
3.
Talanta ; 80(2): 466-72, 2009 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-19836505

RESUMEN

The sensitivity of surface plasmon resonance (SPR) transducers depends on the thickness and spatial organization of interfacial structures at their surfaces. This is because the response of the SPR sensor is determined by integrating the distance-dependent refractive index (spatial interfacial architectures), weighted by the square of the electromagnetic field, from zero to infinite distance. The effect of SPR transducer sensitivity variation on the accuracy of SPR analysis is considered. Our quantitative estimation (based on the results of refractometric studies) gave a value for sensitivity variation of about 3% for the formation of a self-assembled thiocyanate layer or a trypsin-soybean trypsin inhibitor surface complex. The estimated accuracy in measured variation (i.e., by 0.01) for the refractive index of the external medium was 3x10(-4). This restriction, which follows immediately from the physical mechanism of the SPR phenomenon, should be taken into account when analyzing data obtained with the above technique.


Asunto(s)
Algoritmos , Modelos Teóricos , Resonancia por Plasmón de Superficie/métodos , Calibración , Reproducibilidad de los Resultados , Resonancia por Plasmón de Superficie/instrumentación , Resonancia por Plasmón de Superficie/normas , Transductores/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA