Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38750671

RESUMEN

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.

2.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38848447

RESUMEN

Pulsed field ablation (PFA) is an innovative approach in the field of cardiac electrophysiology aimed at treating cardiac arrhythmias. Unlike traditional catheter ablation energies, which use radiofrequency or cryothermal energy to create lesions in the heart, PFA utilizes pulsed electric fields to induce irreversible electroporation, leading to targeted tissue destruction. This state-of-the-art review summarizes biophysical principles and clinical applications of PFA, highlighting its potential advantages over conventional ablation methods. Clinical data of contemporary PFA devices are discussed, which combine predictable procedural outcomes and a reduced risk of thermal collateral damage. Overall, these technological developments have propelled the rapid evolution of contemporary PFA catheters, with future advancements potentially impacting patient care.


Asunto(s)
Arritmias Cardíacas , Humanos , Arritmias Cardíacas/cirugía , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Electroporación/tendencias , Electroporación/métodos , Resultado del Tratamiento , Predicción , Ablación por Catéter/tendencias , Ablación por Catéter/métodos , Técnicas de Ablación/tendencias , Catéteres Cardíacos , Animales
3.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38916275

RESUMEN

AIMS: Technological advancements have contributed to the enhanced precision and lesion flexibility in pulsed-field ablation (PFA) by integrating a three-dimensional mapping system combined with a point-by-point ablation strategy. Data regarding the feasibility of this technology remain limited to some clinical trials. This study aims to elucidate initial real-world data on catheter ablation utilizing a lattice-tip focal PFA/radiofrequency ablation (RFA) catheter in patients with persistent atrial fibrillation (AF). METHODS AND RESULTS: Consecutive patients who underwent catheter ablation for persistent AF via the lattice-tip PFA/RFA catheter were enrolled. We evaluated acute procedural data including periprocedural data as well as the clinical follow-up within a 90-day blanking period. In total, 28 patients with persistent AF underwent AF ablation either under general anaesthesia (n = 6) or deep sedation (n = 22). In all patients, pulmonary vein isolation was successfully achieved. Additional linear ablations were conducted in 21 patients (78%) with a combination of successful anterior line (n = 13, 46%) and roof line (n = 19, 68%). The median procedural and fluoroscopic times were 97 (interquartile range, IQR: 80-114) min and 8.5 (IQR: 7.2-9.5) min, respectively. A total of 27 patients (96%) were interviewed during the follow-up within the blanking period, and early recurrent AF was documented in four patients (15%) including one case of recurrent AF during the hospital stay. Neither major nor minor procedural complication occurred. CONCLUSION: In terms of real-world data, our data confirmed AF ablation feasibility utilizing the lattice-tip focal PFA/RFA catheter in patients with persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Diseño de Equipo , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Masculino , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Femenino , Persona de Mediana Edad , Resultado del Tratamiento , Anciano , Venas Pulmonares/cirugía , Catéteres Cardíacos , Recurrencia , Factores de Tiempo
4.
J Electrocardiol ; 85: 37-38, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38830293

RESUMEN

We present the case of a 60-year-old male patient who was admitted to our hospital after experiencing a syncopal episode. First ECGs showed sinus rhythm with polymorphic premature ventricular complexes and later ventricular tachycardia with a left bundle branch block morphology were recorded. Imaging with TEE and MRI revealed a space-occupying lesion in the left ventricle, which was ultimately identified as a rare cardiac metastasis of renal cell carcinoma. Treatment was initiated with monoclonal antibodies resulting in lesion regression. This case highlights the importance of comprehensive diagnostic in patients with history of malignancy.

5.
J Cardiovasc Electrophysiol ; 34(12): 2425-2433, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37767744

RESUMEN

INTRODUCTION: Pulsed field ablation (PFA) is a new ablation technology for atrial fibrillation (AF). Data regarding early recurrences of atrial tachyarrhythmia (ERAT) after PFA-pulmonary vein isolation (PVI) are sparse. METHODS: Consecutive patients with symptomatic AF were enrolled to undergo PFA-PVI. A dedicated catheter delivering bipolar energy (1.9-2.0 kV) was used. Late recurrence (LR) was defined as documented AF/atrial tachycardia (AT) lasting more than 30 s after a 90-day blanking period. RESULTS: Two hundred and thirty-one patients (42% female, age 69 ± 12, 55% paroxysmal AF [PAF]) were included in this analysis. Median follow-up time was 367 days (interquartile range: 253-400). Forty-six patients (21%) experienced ERAT after a median of 23 days (46% in PAF and 54% in persistent AF [persAF]). Kaplan-Meier estimated freedom of AF/AT was 74.2% at 1 year, 81.8% for PAF, and 64.8% for persAF (p = .0079). Of patients experiencing ERAT, an LR was observed in 54%. There was no significant difference of LR between those who presented with very early ERAT (0-45 days) and those with ERAT (46-90 days) (p = .57). In multivariate analysis, ERAT (hazard ratio [HR]: 3.370; 95% confidence interval [95% CI]: 1.851-6.136; p < .001) and female sex (HR: 2.048; 95% CI: 1.114-3.768; p = .021) were the only independent predictors for LR. CONCLUSIONS: ERAT could be recorded in 21% of patients after PFA-PVI and was an independent predictor for LR. We found no difference in the rate of LRs among patients experiencing ERAT before or after 45 days.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Factores de Tiempo , Recurrencia , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía
6.
Catheter Cardiovasc Interv ; 101(6): 1144-1153, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36924020

RESUMEN

AIMS: To compare outcomes of patients who underwent left atrial appendage occlusion (LAAO) for nonvalvular atrial fibrillation (NVAF) and contraindication to anticoagulants due to history of either gastrointestinal (GI) or intracranial (IC) bleeding. METHODS: Patients with NVAF that underwent LAAO for GI or IC bleeding from seven centers were included in this observational study. Baseline characteristics, procedural features, and follow-up data were collected, and compared between the two groups. The primary outcomes were incidence of ischemic and hemorrhagic events at 12-month. RESULTS: Six hundred twenty-eight patients were included, 57% with previous GI-bleeding, and 43% with previous IC-bleeding. Median CHA 2 DS 2-VASc score was 4 (interquartile range [IQRs]: 3-5) for both GI-bleeding and IC-bleeding patients, while GI-bleeding patients had a higher HAS-BLED score (4 [IQRs: 3-4] vs. 3 [IQRs]: 2-3]; p = 0.001). At 12-month follow-up, relative risk reduction for stroke was similar between the two groups. The GI-bleeding group had more hemorrhagic events compared to IC-bleeding group (any bleeding 8.4% vs. 3.2%; p = 0.012; major bleeding BARC 3-5: 4.3% vs. 1.8; p = 0.010). At multivariate analysis history of GI bleeding was an independent predictor of hemorrhagic events (adjusted HR: 2.39, 95% confidence interval: 1.02-5.63; p = 0.047). CONCLUSIONS: Outcomes after LAAO may be affected by the different indications for the procedure. In our study, GI-bleeding and IC-bleeding as indication to LAAO differ in their baseline characteristics. LAAO confirms its efficacy in ischemic risk reduction in both groups, while GI bleeding seems to be an independent predictor of bleeding recurrence at 12 months behind the antithrombotic regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/prevención & control , Hemorragias Intracraneales/etiología , Sistema de Registros , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Lógica
7.
Europace ; 25(2): 433-440, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36427201

RESUMEN

AIMS: Pulsed-field ablation (PFA) can offer a novel perspective for atrial fibrillation (AF) ablation. We aimed to characterize the incidence of pulmonary vein (PV) reconnection, types of recurrent atrial tachyarrhythmia (ATa) and lesion quality after PFA-guided PV isolation (PVI). METHODS AND RESULTS: Patients undergoing second ablation for recurrent ATa following the initial PVI using the pentaspline PFA catheter were investigated. The rate of PV reconnection, the features of recurrent ATa, and the amount of isolated posterior wall (PW) surface area (ISAPW%) (ratio of the isolated- to total surface area on PW) were analyzed. RESULTS: Among 360 patients treated with PFA, 25 patients (paroxysmal AF, n = 19) with 99 PVs underwent a second procedure 6.1 ± 4.0 months after the initial procedure. The rate of PV reconnection was 9.1% (9 PVs). Patients presented with atrial tachycardia (AT) (n = 16), AF (n = 8) and typical atrial flutter (n = 1). The mechanism of all but one AT was macro-reentry. The critical isthmus was found to be linked to the initial lesion set at the left atrial (LA) PW in eight patients and linked to pre-existing substrate at the LA anterior wall in four patients. One AT had a focal origin at the septum. In three patients, AT were unmappable. Mean ISAPW% was 72.7 ± 19.0%. CONCLUSION: We revealed a remarkable low reconnection rate with a large antral lesion at the PW after pentaspline PFA catheter-guided PVI. However, macro-reentrant AT with a critical isthmus at the LAPW linked to the PVI lesion set was commonly observed.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Resultado del Tratamiento
8.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37116126

RESUMEN

AIMS: A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS: Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION: The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos , Venas Pulmonares/cirugía
9.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37379528

RESUMEN

AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Poria , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía , Venas Pulmonares/cirugía , Recurrencia
10.
Circ J ; 87(7): 950-956, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37286488

RESUMEN

BACKGROUND: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃). CONCLUSIONS: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Resultado del Tratamiento , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Venas Pulmonares/cirugía , Catéteres , Recurrencia
11.
Pacing Clin Electrophysiol ; 46(5): 414-418, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36424836

RESUMEN

Pulsed field ablation (PFA) using high-voltage electrical energy is a novel and powerful ablation modality. However, PFA as a first-line rhythm control in atrial fibrillation (AF) has been rarely described; whether PFA interacts with the pacemaker (PM) has been seldom reported. We reported PFA of AF in a patient with PM who needed effective rhythm control. Pulmonary vein isolation (PVI) was successfully performed without complication, and the procedure was extremely fast (skin-to-skin 25 min.) with short fluoroscopic time (3.9 min). PFA had no influence on the PM function. Six months' follow-up showed good clinical outcome and significantly decreased AF burden.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Resultado del Tratamiento , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
12.
J Cardiovasc Electrophysiol ; 33(7): 1371-1379, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35488736

RESUMEN

BACKGROUND: The iCLAS ultra-low temperature cryoablation (ULTC) system has recently been brought to the market. A combination of a newly exploited cryogen and interchangeable stylet enables flexible and continuous lesion creation in atrial fibrillation (AF) ablation. The use of an esophageal warming balloon is recommended when using the system to reduce the potential for collateral esophageal injury. OBJECTIVE: To describe the initial clinical experience when using ULTC in the AF treatment without general anesthesia (GA). METHODS: Consecutive patients undergoing AF ablation using ULTC under deep sedation without GA were enrolled. We assessed the procedural data focusing on "single-shot isolation" defined as successful pulmonary vein (PV) isolation after the first application. Esophagogastroduodenoscopy was systematically performed the day after ablation. RESULTS: A total of 27 AF patients (67% paroxysmal AF) were analyzed. Onehundred four out of 106 PVs (98.1%) were isolated solely using ULTC. The mean procedure time was 79 ± 30 min. The mean number of applications per PV was 2.6 ± 1.0. Single-shot isolation was achieved in 57 PVs (54%) varying across PVs from left superior to inferior PVs (40%-64%). The single procedure 6-month recurrence-free rate was 84%. No major complication (cerebrovascular event, pericardial effusion/tamponade, esophageal damage on esophagogastroduodenoscopy) occurred. A single transient phrenic nerve palsy occurred during the right superior PV ablation, which had recovered by the 3-month follow-up appointment. CONCLUSIONS: AF ablation using the novel ULTC system seemed feasible without GA and enabled a >50% single-shot isolation rate. The promising safety profile has to be confirmed in large-scale studies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Venas Pulmonares/cirugía , Temperatura , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 33(6): 1106-1115, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35355367

RESUMEN

INTRODUCTION: Ablation of atrial fibrillation in the context of obesity can be challenging. We sought to evaluate the role of cryoballoon pulmonary vein isolation (CB-PVI) in obese patients with symptomatic atrial fibrillation (AF). METHODS: Patients with a BMI ≥ 25 kg/m2 and symptomatic AF who underwent CB-PVI were retrospectively enrolled. Three groups were defined (G1: BMI of 25-29 kg/m2 ; G2: BMI of 30-34 kg/m2 ; G3: BMI ≥ 35 kg/m2 ). RESULTS: 600 patients were included (59% male; 66 ± 11 years old); 337, 149, and 114 were assigned to G1, G2, and G3, respectively. Acute procedural success was recorded in 99.7% of patients. Procedural and fluoroscopy time were comparable but the radiation dose was significantly higher in G3. Procedural complications were 3% in G1, 5.4% in G2, and 8.8% in G3 (p = .01). The overall freedom from AF after 1-year was 77%. G3 had a significantly worse 1-year success rate compared to G1 and G2 (G3: 66.5% vs. G1: 78.4%; p = .015 and vs. G2: 82.5%; p = .008) with reduced 1-year success in paroxysmal AF (G1: 84.0%; G2: 86.3%; and G3: 69.6%) but not in persistent AF (G1: 68.7%; G2: 77.4%; and G3: 62.1%). G3 showed similar success rates irrespective of AF form (PAF: 69.6% vs. persAF 62.1%; p = .501). CONCLUSION: Cryoballoon ablation in obese patients can be effective with an acceptable safety profile, 77% of patients were in stable SR at 1 year. Severe obese patients (BMI ≥ 35) showed reduced procedural safety and 1-year success rate. In association with life style modification, CB ablation may represent a strategy to enhance rhythm control in the context of obesity.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Índice de Masa Corporal , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/diagnóstico , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
14.
Europace ; 24(10): 1684-1690, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35942585

RESUMEN

The use of a blanking period (BP) after an atrial fibrillation (AF) ablation procedure is a common practice, but recent data questions the benign nature of early recurrences of atrial tachyarrhythmias (ERATs). A physician-based survey was carried out by the European Heart Rhythm Association (EHRA) to investigate the current definition and applicability of BP and ERAT management. An online questionnaire was sent to clinical and interventional electrophysiologists. A total of 436 respondents (88% interventional electrophysiologists) reported observing ERATs in 25% (interquartile range 15-35) of patients, less commonly in paroxysmal AF (PAF) compared with persistent AF (persAF). The median reported duration of BP used by respondents was 90 days, with 22% preferring a shorter BP duration for PAF patients compared with persAF. Half of the patients with ERATs are expected to also experience late recurrences (LR). Isolated episodes of ERATs are treated conservatively by 99% of the respondents, but repeat ablation during the BP is preferred by 20% of electrophysiologists for multiple ERATs and by 16% in patients with organized atrial tachyarrhythmias. In conclusion, ERATs are commonly observed after AF ablation, particularly in persAF patients, and are perceived as predictors of LR by half of the respondents. A general adherence to a 90-day BP duration was observed. During this time period, ERAT is mainly treated conservatively, but repeat ablation during the BP is occasionally offered to patients with multiple ERATs and those with organized atrial tachyarrhythmias.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/métodos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Encuestas y Cuestionarios , Resultado del Tratamiento
15.
Pacing Clin Electrophysiol ; 45(12): 1383-1384, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35821363

RESUMEN

An 89-year-old woman underwent left atrial appendage (LAA) closure (LAAC) in our hospital because of recurrent gastrointestinal bleedings. The first transesophageal echocardiography (TEE) follow-up at six weeks revealed a complete sealing of the LAA and no device related thrombus. In a TEE follow-up at one year after the LAA closure, a large device related thrombus (6 × 3 cm) was found. Treated with oral anticoagulation (apixaban) the thrombus showed a partial resolution one year later.


Asunto(s)
Apéndice Atrial , Trombosis , Anciano de 80 o más Años , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía
16.
J Cardiovasc Electrophysiol ; 32(3): 616-624, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33484215

RESUMEN

BACKGROUND: Radiofrequency (RF) high-power ablation appears to be a novel concept in treating atrial fibrillation (AF). The ablation-index (AI) has been linked with the durability of pulmonary vein isolation (PVI). To report the midterm clinical results of a new ablation strategy using AI-guided high-power (50 W) ablation (AI-HP). METHODS AND RESULTS: Symptomatic AF patients were included and underwent wide-area circumferential PVI. Contact-force catheters were used, RF power was set to 50 W targeting AI values (550/400 for anterior/posterior) and interlesion distance 6 mm. Luminal esophageal temperature (LET) was monitored during the procedure; patients with LET ≥39°C underwent post-ablation esophageal-endoscopy. Seventy-two-hour-Holter ECGs were scheduled during follow-up. Procedural PVI was achieved in all (N = 122; mean age, 68.2 years; male, 71.3%) patients, rate of first-pass PVI was 96.7% per patient. Procedural mean RF time was 11.5 min, and mean RF time during posterior wall segment was 3.1 min. Per RF-lesion, the mean contact force, RF duration, AI, and impedance-drop at anterior/posterior wall were 26 ± 14 g/23 ± 12 g, 16.2 ± 7.5 s/8.8 ± 3.6 s, 552 ± 53/438 ± 47, and 13 ± 6 Ω/9 ± 5 Ω, respectively. Mean PVI procedural-time, 55.8 min; mean procedural fluoroscopic time, 5.6 min. Three (2.5%) patients had asymptomatic endoscopic small erosion/erythema esophageal lesions, no serious adverse events were observed. During a 15-month follow-up, overall single-procedure freedom from clinical recurrence of AF/atrial tachycardia (AT) off antiarrhythmic drug after blanking period was 85.2% (89.4% for paroxysmal AF, 80.4% for persistent AF). CONCLUSION: The AI-HP (50 W) appears as an efficient ablation technique in treating AF and leads to a high single-procedure arrhythmia-free survival at 15 months.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Estudios de Seguimiento , Humanos , Masculino , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
17.
J Cardiovasc Electrophysiol ; 32(11): 2923-2932, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34535929

RESUMEN

BACKGROUND: The endoscopic ablation system (EAS) is an established ablation device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The novel X3 EAS is now equipped with a contiguous circumferential ablation mode (RAPID mode). AIM: To determine the feasibility of single-shot fashioned ablation using X3. METHODS: Consecutive patients who underwent AF ablation using X3 were enrolled. We assessed the acute procedural data focusing on "Single-sweep PVI" defined as successful PVI with a single RAPID mode energy application, and on "first-pass isolation" defined as successful PVI after initial circular lesion set. RESULTS: One hundred AF patients (56% male, age: 68 ± 10 years, 66% paroxysmal AF) were analyzed. A total of 379 of 383 PVs (99%) were isolated with X3. Single-sweep PVI and first-pass-isolation were achieved in 214 PVs (56%) and in 362 PVs (95%), respectively. Single-sweep PVI rates varied across PVs with higher rates at the superior PVs (61.2% vs. inferior PVs: 49.5%, p = .0239) and at PVs with maximal ostial diameter <24 mm (57.6% vs. >24 mm: 36.8%, p = .0151). The mean total procedure and fluoroscopy times were 43.0 ± 10 and 4.0 ± 2 min, respectively. In none of the patients an acute thromboembolic event (stroke or transient ischemic attack) or a pericardial effusion/tamponade occurred. A single transient phrenic nerve palsy was observed. CONCLUSION: The new X3 EAS allows for single-shot fashioned ablation in terms of single-sweep PVI in half or more of PVs. The new RAPID ablation mode leads to an improved rate of first-pass isolation associated with very short procedure times without compromising safety.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Rayos Láser , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Resultado del Tratamiento
18.
J Cardiovasc Electrophysiol ; 32(4): 984-993, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33634549

RESUMEN

OBJECTIVES: To evaluate the feasibility, procedural data, and lesion characteristics of the anterior line (AL) and roofline (RL) ablation by using ablation index (AI)-guided high power (50 W) among patients with recurrent atrial fibrillation (AF) or atrial tachycardia (AT) after pulmonary vein isolation (PVI). METHODS: Data from 35 consecutive patients with macro-reentrant left atrial tachycardia or substrate at the left atrium anterior wall or roof after previous PVI were collected. Ablation power was set to 50 W, targeting AI 500 for AL and 400 for RL. The first-pass conduction block (FPB) was evaluated. The AL was arbitrarily divided into three (caudal, middle, and cranial) segments to analyze the location of conduction gaps in non-FPB patients. RESULTS: A total of 32 AL and 17 RL were deployed and FPB was achieved in 24 (75%) and 14 (82%) of them, respectively. In the non-FPB group, the most frequent gap location along the AL was the middle third. The final block of AL was achieved in 97%, and the block of RL was achieved in 100%. The radiofrequency (RF) ablation time was short (2.9 ± 0.8 min for AL and 46.2 ± 15.6 s for RL). For AL, the female gender was significantly more frequent in FPB than in non-FPB patients (p = .028); patients with non-FPB were associated with significantly longer RF time as compared to patients with FPB (204 ± 47 s vs. 161 ± 41 s; p = .02). No procedural complications occurred. CONCLUSION: AI-guided high-power (50 W) ablation appears to be a feasible, effective, and fast technique for AL and RL ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Estudios de Factibilidad , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
19.
Europace ; 23(6): 868-877, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33458770

RESUMEN

AIMS: Cryoballoon (CB) pulmonary vein isolation (PVI) is an accepted ablation strategy for rhythm control in atrial fibrillation (AF). We describe efficacy and safety in a high volume centre with a long experience in the use of the second-generation CB (CB2). METHODS AND RESULTS: Consecutive paroxysmal AF (PAF) or persistent AF (persAF) patients undergoing CB2-PVI were enrolled. Procedural data, efficacy, and safety issues were systematically collected. The 28 mm CB2 was used in combination with an inner lumen spiral catheter, a luminal oesophageal temperature (LET) probe was used with a cut-off of 15°C, the phrenic nerve (PN) monitored during septal PVs ablation. Freeze duration was mainly set at 240 s with a bonus application in case of delayed time-to-isolation (TTI > 75 s). A total of 1017 CB2 procedures were analysed (58% male, 66 ± 12 years old, 70% with PAF). 3964 PVs were identified, 99.8% PVs isolated using solely the 28 mm CB. Mean procedure time was 69 ± 25 min, TTI during the first application was recorded in 77% of PVs after a mean of 48 ± 31 s. We recorded 0.2% cardiac tamponade, 4.8% PN injury (1.6% of PN palsy), and 19% of LET < 15°C. Among 725 patients with follow-up data, 84% with PAF and 75% with persAF were in stable SR at 1 year. Shorter freezing duration and longer TTI were procedural predictors for recurrence. CONCLUSION: Cryoballoon procedures are fast and associated with a benign safety profile. Shorter TTI and longer freeze durations are associated with sinus rhythm during follow-up.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
20.
Pacing Clin Electrophysiol ; 44(8): 1371-1379, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34152640

RESUMEN

BACKGROUND: Recently a double 120 s freeze cryoballoon (CB) pulmonary vein isolation (PVI) protocol proved to be non inferior to a double 240 s freeze protocol in terms of atrial fibrillation (AF) recurrences. We hypothesized that this approach could also result in an increased procedure safety. METHODS: Eighty consecutive patients treated with a double 120 s freeze protocol (Group CB120) were compared with 80 previous consecutive patients treated with a single 240 s freeze protocol (Group CB240). Procedures were performed with a temperature probe to monitor the luminal esophageal temperature (LET), using a cut off for cryoenergy interruption of 15°C. During ablation at the septal pulmonary veins (PVs), the phrenic nerve (PN) function was monitored by pacing. RESULTS: In CB120 and CB240 the rate of single shot isolation was similar in all PVs. Time to isolation was not different between the two groups. Mean minimal esophageal temperature was lower in LSPV and LIPV of the CB240 group. A total of 4/80 patients (5%) of the CB120 group experienced a PN injury, but no persistent form was recorded; 11/80 patients (14%) of the CB240 group experienced a PN injury, three in a persistent form (p = .10). A LET <15°C was recorded in 3/80 patients (4%) in the CB120 group and in 16/80 patients (20%) in the CB240 group (p < .01). Composite rate of energy-related safety events (LET <15°C and PN injury) was significantly lower in the CB120 (34% vs. 9%, p < .01). CONCLUSIONS: Safety of second generation CB PVI can be increased using a double 120 s freeze protocol.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/instrumentación , Seguridad del Paciente , Venas Pulmonares/cirugía , Anciano , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA