Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Interv Cardiol ; 2021: 7108284, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34867107

RESUMEN

AIMS: The aim of this study was to assess the safety and diagnostic efficacy of frequency-domain optical coherence tomography (FD-OCT) in identifying functional severity of the left main coronary artery (LM) stenosis determined by fractional flow reserve (FFR). METHODS AND RESULTS: 101 patients with LM lesion (20-70% diameter stenosis angiographically) underwent FFR measurement and FD-OCT imaging of the LM. The following parameters were measured by FD-OCT in the LM: reference lumen area (RLA), reference lumen diameter (RLD), minimum lumen area (MLA), minimum lumen diameter (MLD), % lumen area stenosis, and % diameter stenosis. The LM lesions were analyzable by FD-OCT in 88/101 (87.1%) patients. FFR at maximum hyperemia was ≤0.80 in 39/88 (44.3%) patients. FFR values were correlated significantly with FD-OCT-derived LM lumen parameters. An MLA cutoff value of 5.38 mm2 had the highest sensitivity and specificity of 82% and 81%, respectively, followed by an MLD of 2.43 mm (sensitivity 77%, specificity 72%) and AS of 60% (sensitivity 72%, specificity 72%) for predicting FFR <0.80. CONCLUSIONS: FD-OCT is a safe and feasible imaging technique for the assessment of LM stenosis. An FD-OCT-derived MLA of ≤5.38 mm2 strongly predicts the functional severity of an LM lesion.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Hiperemia , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Tomografía de Coherencia Óptica
2.
Catheter Cardiovasc Interv ; 86(2): 237-46, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25620191

RESUMEN

AIMS: The purpose of the present study was to assess the incidence, predictors and long term prognosis of stent edge dissections identified by (OCT) after the implantation of bare metal (BMS) and drug eluting stents (DES). METHODS AND RESULTS: We studied 74 patients who underwent percutaneous coronary intervention (PCI) because of an acute coronary syndrome. Edge dissections were found in 29 of 74 patients (39.1%). Independent predictors of edge dissections were: the presence of ST-elevation myocardial infarction (STEMI) (P = 0.005, odds ratio 11.78; 95% Cl 2.06-67.10), the small reference lumen diameter (P = 0.009, odds ratio 0.11; 95% Cl 0.02-0.58) and the short stents implanted (P = 0.013, odds ratio 0.83; 95% Cl 0.72-0.96). During a follow-up period of 25.6 ± 9.4 months 11 patients presented with at least one major adverse cardiac event. Event free survival was significantly decreased in patients with edge dissection with a flap thickness >0.31 mm compared to patients with thinner flap or without any dissection (P < 0.001). CONCLUSIONS: OCT frequently detects edge dissections, usually related to STEMI presentation and to PCI technique. Deep vessel wall injury at stent edges with a dissection flap thickness more than 0.31mm carries an adverse clinical impact on long-term clinical outcome.


Asunto(s)
Síndrome Coronario Agudo/terapia , Vasos Coronarios/patología , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Stents , Tomografía de Coherencia Óptica , Síndrome Coronario Agudo/patología , Anciano , Área Bajo la Curva , Distribución de Chi-Cuadrado , Supervivencia sin Enfermedad , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/patología , Oportunidad Relativa , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Curva ROC , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 79(4): 625-7, 2012 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21735524

RESUMEN

The time course of complete arterial healing after drug eluting stent implantation is unknown. We present a case of incomplete endothelialization and late stent malapposition identified by optical coherence tomography 8 years after a sirolimus-eluting stent implantation, which was not related with any adverse clinical event.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Sirolimus/administración & dosificación , Tomografía de Coherencia Óptica , Cicatrización de Heridas , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angiografía Coronaria , Humanos , Masculino , Neointima/patología , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
4.
Hellenic J Cardiol ; 57(2): 129-33, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27445030

RESUMEN

We present the case of a patient with non-ST-elevated myocardial infarction due to very late stent thrombosis 2 years after a sirolimus-eluting stent implantation (SES). Optical coherence tomography (OCT) imaging identified vessel wall destruction of the whole stented coronary segment with multiple cavity formations along the entire stent length, severe strut malapposition and thrombi. The patient was treated successfully with the implantation of a bare metal stent (BMS). Follow-up OCT imaging at 12 months revealed the improvement of vascular healing with complete re-endothelialization of the distal parts of the new BMS, while the stent body remained partly uncovered, suggesting vascular toxicity due to the old SES.


Asunto(s)
Reestenosis Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos/efectos adversos , Tomografía de Coherencia Óptica/métodos , Adulto , Reestenosis Coronaria/etiología , Humanos , Masculino , Infarto del Miocardio sin Elevación del ST/etiología , Sirolimus/administración & dosificación , Stents , Resultado del Tratamiento
5.
Angiology ; 56(2): 123-30, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15793600

RESUMEN

Despite advances in the treatment of patients with acute coronary syndromes, there has been no significant decrease in the incidence of cardiogenic shock, while its mortality remains frustratingly high. Shock is a progressive state of hypotension (systolic blood pressure < 90 mm Hg) lasting at least 30 minutes, which leads to systemic hypoperfusion. It is more common in patients with ST-segment elevation myocardial infarction than in patients with other acute coronary syndromes. Revascularization is associated with better outcomes than intensive medical therapy, especially in patients < 75 years of age with cardiogenic shock. Adjunctive therapies include inotropes, vasopressor therapy, intra-aortic balloon pump counterpulsation, and IIb/IIIa blockade to prevent no-reflow phenomenon during primary percutaneous transluminal coronary angioplasty. Other adjunctive therapies which are investigated are improved mechanical support devices, and as medical therapy for myocyte protection nicorandil, glucose/insulin/potassium infusions and direct inhibition of Na+/H+ exchanger.


Asunto(s)
Enfermedad Coronaria/complicaciones , Choque Cardiogénico/terapia , Cardiotónicos/uso terapéutico , Enfermedad Coronaria/mortalidad , Enfermedad Coronaria/terapia , Humanos , Contrapulsador Intraaórtico , Revascularización Miocárdica , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Tasa de Supervivencia , Síndrome , Resultado del Tratamiento , Vasoconstrictores/uso terapéutico
6.
J Invasive Cardiol ; 14(7): 417-9, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12082197

RESUMEN

We describe a case of successful direct coronary stenting of two tight lesions, one at the site of the left internal mammary artery (LIMA) graft anastomosis with left anterior descending coronary artery and the other at the site of the anastomosis between the right internal mammary artery (RIMA) graft and the right coronary artery. To our knowledge, this is the first reported case of successful direct stent implantation through the LIMA and RIMA.


Asunto(s)
Angina Inestable/terapia , Angioplastia Coronaria con Balón/métodos , Estenosis Coronaria/cirugía , Oclusión de Injerto Vascular/terapia , Anastomosis Interna Mamario-Coronaria/métodos , Anciano , Angina Inestable/diagnóstico por imagen , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estudios de Seguimiento , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Anastomosis Interna Mamario-Coronaria/efectos adversos , Masculino , Stents , Resultado del Tratamiento
7.
Int J Cardiol ; 154(3): 287-92, 2012 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-20974497

RESUMEN

BACKGROUND: OCT with its unique image resolution is the ideal method to detect culprit lesion characteristics in different clinical presentations. The identification of inflammatory markers related to plaque characteristics may be of clinical importance. METHODS: Thirty-two patients with acute coronary syndromes (ACS) and fourteen patients with stable angina pectoris (SAP) were enrolled in this study. Culprit lesion morphology was assessed by optical coherence tomography (OCT) in patients with ACS and SAP. The possible relations between serum levels of high sensitivity-C reactive protein (hs-CRP) and interleukin-18 (IL-18) with plaque characteristics were investigated in those patients. RESULTS: Plaque rupture and thin-cap fibroatheroma (TCFA) were detected more frequently in ACS patients compared with SAP patients, (78.6% vs. 14.3%, p<0.001, 92.9% vs. 14.3%, p<0.001, respectively). Higher levels of serum hs-CRP and IL-18 were found in patients with plaque rupture vs. those with no plaque rupture (median value: 19.2mg/L vs. 1.6 mg/L, p<0.001 and 219.5 pg/ml vs. 127.5 pg/ml, p=0.001 respectively), and TCFA vs. those without TCFA (median value: 15.2mg/L vs. 1.6 mg/L, p=0.004 and 209.0 pg/ml vs.153.2 pg/ml, p=0.03 respectively). Serum hs-CRP was the only independent predictor of plaque rupture (p=0.02, odds ratio 1.1, 95% confidence interval 1.0 to 1.2). A cut-off value of hs-CRP>4.5mg/L could detect ruptured plaque with a sensitivity of 91.7% and a specificity of 77.8%. CONCLUSIONS: OCT detected plaque rupture and TCFA more frequent in ACS patients compared with SAP. Elevated hs-CRP and IL-18 were positively related to plaque instability and rupture.


Asunto(s)
Síndrome Coronario Agudo/sangre , Síndrome Coronario Agudo/patología , Angina Estable/patología , Proteína C-Reactiva/análisis , Interleucina-18/sangre , Placa Aterosclerótica/sangre , Placa Aterosclerótica/patología , Tomografía de Coherencia Óptica , Anciano , Biomarcadores/sangre , Femenino , Humanos , Inflamación/sangre , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos
8.
Hellenic J Cardiol ; 52(2): 168-70, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21478129

RESUMEN

Optical coherence tomography (OCT) is an optical analogue of intravascular ultrasound that has recently been proposed as a high-resolution imaging method for plaque characterization. Histology-controlled studies have shown that OCT can evaluate the characteristics of culprit lesions, such as fibrous cap thickness, fibrous cap macrophage density, lipid core and intracoronary thrombus. We describe a case where OCT was used to evaluate the culprit lesion morphology in a patient with acute myocardial infarction. The patient was treated with stent implantation. OCT was also used to confirm good stent apposition.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Placa Aterosclerótica/diagnóstico , Tomografía de Coherencia Óptica , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Humanos , Masculino , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/terapia
9.
Int J Cardiol ; 137(3): e77-8, 2009 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-19446897

RESUMEN

Late stent malapposition may play a role in stent thrombosis, but the results of several intravascular ultrasound and few optical coherence tomography (OCT) studies are still controversial. We present a case of late acquired stent malapposition after drug eluting stent implantation, identified by follow-up OCT examination at 12 months, which was not related with any adverse clinical event.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Tomografía de Coherencia Óptica , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Túnica Íntima
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA