Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Clin Infect Dis ; 75(11): 1883-1892, 2022 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-35446944

RESUMEN

BACKGROUND: Favipiravir, an oral, RNA-dependent RNA polymerase inhibitor, has in vitro activity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Despite limited data, favipiravir is administered to patients with coronavirus disease 2019 (COVID-19) in several countries. METHODS: We conducted a phase 2, double-blind, randomized controlled outpatient trial of favipiravir in asymptomatic or mildly symptomatic adults with a positive SARS-CoV-2 reverse-transcription polymerase chain reaction assay (RT-PCR) within 72 hours of enrollment. Participants were randomized to receive placebo or favipiravir (1800 mg twice daily [BID] day 1, 800 mg BID days 2-10). The primary outcome was SARS-CoV-2 shedding cessation in a modified intention-to-treat (mITT) cohort of participants with positive enrollment RT-PCRs. Using SARS-CoV-2 amplicon-based sequencing, we assessed favipiravir's impact on mutagenesis. RESULTS: We randomized 149 participants with 116 included in the mITT cohort. The participants' mean age was 43 years (standard deviation, 12.5 years) and 57 (49%) were women. We found no difference in time to shedding cessation overall (hazard ratio [HR], 0.76 favoring placebo [95% confidence interval {CI}, .48-1.20]) or in subgroups (age, sex, high-risk comorbidities, seropositivity, or symptom duration at enrollment). We detected no difference in time to symptom resolution (initial: HR, 0.84 [95% CI, .54-1.29]; sustained: HR, 0.87 [95% CI, .52-1.45]) and no difference in transition mutation accumulation in the viral genome during treatment. CONCLUSIONS: Our data do not support favipiravir at commonly used doses in outpatients with uncomplicated COVID-19. Further research is needed to ascertain if higher favipiravir doses are effective and safe for patients with COVID-19. CLINICAL TRIALS REGISTRATION: NCT04346628.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Adulto , Humanos , Femenino , Masculino , SARS-CoV-2 , Pacientes Ambulatorios , Antivirales , Método Doble Ciego , Resultado del Tratamiento
2.
Eur J Nucl Med Mol Imaging ; 48(8): 2416-2425, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33416955

RESUMEN

PURPOSE: While sampled or short-frame realizations have shown the potential power of deep learning to reduce radiation dose for PET images, evidence in true injected ultra-low-dose cases is lacking. Therefore, we evaluated deep learning enhancement using a significantly reduced injected radiotracer protocol for amyloid PET/MRI. METHODS: Eighteen participants underwent two separate 18F-florbetaben PET/MRI studies in which an ultra-low-dose (6.64 ± 3.57 MBq, 2.2 ± 1.3% of standard) or a standard-dose (300 ± 14 MBq) was injected. The PET counts from the standard-dose list-mode data were also undersampled to approximate an ultra-low-dose session. A pre-trained convolutional neural network was fine-tuned using MR images and either the injected or sampled ultra-low-dose PET as inputs. Image quality of the enhanced images was evaluated using three metrics (peak signal-to-noise ratio, structural similarity, and root mean square error), as well as the coefficient of variation (CV) for regional standard uptake value ratios (SUVRs). Mean cerebral uptake was correlated across image types to assess the validity of the sampled realizations. To judge clinical performance, four trained readers scored image quality on a five-point scale (using 15% non-inferiority limits for proportion of studies rated 3 or better) and classified cases into amyloid-positive and negative studies. RESULTS: The deep learning-enhanced PET images showed marked improvement on all quality metrics compared with the low-dose images as well as having generally similar regional CVs as the standard-dose. All enhanced images were non-inferior to their standard-dose counterparts. Accuracy for amyloid status was high (97.2% and 91.7% for images enhanced from injected and sampled ultra-low-dose data, respectively) which was similar to intra-reader reproducibility of standard-dose images (98.6%). CONCLUSION: Deep learning methods can synthesize diagnostic-quality PET images from ultra-low injected dose simultaneous PET/MRI data, demonstrating the general validity of sampled realizations and the potential to reduce dose significantly for amyloid imaging.


Asunto(s)
Aprendizaje Profundo , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
3.
Radiology ; 290(3): 649-656, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30526350

RESUMEN

Purpose To reduce radiotracer requirements for amyloid PET/MRI without sacrificing diagnostic quality by using deep learning methods. Materials and Methods Forty data sets from 39 patients (mean age ± standard deviation [SD], 67 years ± 8), including 16 male patients and 23 female patients (mean age, 66 years ± 6 and 68 years ± 9, respectively), who underwent simultaneous amyloid (fluorine 18 [18F]-florbetaben) PET/MRI examinations were acquired from March 2016 through October 2017 and retrospectively analyzed. One hundredth of the raw list-mode PET data were randomly chosen to simulate a low-dose (1%) acquisition. Convolutional neural networks were implemented with low-dose PET and multiple MR images (PET-plus-MR model) or with low-dose PET alone (PET-only) as inputs to predict full-dose PET images. Quality of the synthesized images was evaluated while Bland-Altman plots assessed the agreement of regional standard uptake value ratios (SUVRs) between image types. Two readers scored image quality on a five-point scale (5 = excellent) and determined amyloid status (positive or negative). Statistical analyses were carried out to assess the difference of image quality metrics and reader agreement and to determine confidence intervals (CIs) for reading results. Results The synthesized images (especially from the PET-plus-MR model) showed marked improvement on all quality metrics compared with the low-dose image. All PET-plus-MR images scored 3 or higher, with proportions of images rated greater than 3 similar to those for the full-dose images (-10% difference [eight of 80 readings], 95% CI: -15%, -5%). Accuracy for amyloid status was high (71 of 80 readings [89%]) and similar to intrareader reproducibility of full-dose images (73 of 80 [91%]). The PET-plus-MR model also had the smallest mean and variance for SUVR difference to full-dose images. Conclusion Simultaneously acquired MRI and ultra-low-dose PET data can be used to synthesize full-dose-like amyloid PET images. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Catana in this issue.


Asunto(s)
Compuestos de Anilina/administración & dosificación , Encefalopatías/diagnóstico por imagen , Aprendizaje Profundo , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Estilbenos/administración & dosificación , Anciano , Enfermedad de Alzheimer/diagnóstico por imagen , Amiloide/análisis , Disfunción Cognitiva/diagnóstico por imagen , Femenino , Humanos , Enfermedad por Cuerpos de Lewy/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Imagen Multimodal , Trastornos Parkinsonianos/diagnóstico por imagen , Estudios Retrospectivos
5.
Sci Rep ; 11(1): 7501, 2021 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-33820939

RESUMEN

Despite numerous research efforts, the precise mechanisms of concussion have yet to be fully uncovered. Clinical studies on high-risk populations, such as contact sports athletes, have become more common and give insight on the link between impact severity and brain injury risk through the use of wearable sensors and neurological testing. However, as the number of institutions operating these studies grows, there is a growing need for a platform to share these data to facilitate our understanding of concussion mechanisms and aid in the development of suitable diagnostic tools. To that end, this paper puts forth two contributions: (1) a centralized, open-access platform for storing and sharing head impact data, in collaboration with the Federal Interagency Traumatic Brain Injury Research informatics system (FITBIR), and (2) a deep learning impact detection algorithm (MiGNet) to differentiate between true head impacts and false positives for the previously biomechanically validated instrumented mouthguard sensor (MiG2.0), all of which easily interfaces with FITBIR. We report 96% accuracy using MiGNet, based on a neural network model, improving on previous work based on Support Vector Machines achieving 91% accuracy, on an out of sample dataset of high school and collegiate football head impacts. The integrated MiG2.0 and FITBIR system serve as a collaborative research tool to be disseminated across multiple institutions towards creating a standardized dataset for furthering the knowledge of concussion biomechanics.


Asunto(s)
Acceso a la Información , Algoritmos , Lesiones Traumáticas del Encéfalo/diagnóstico , Difusión de la Información , Humanos , Protectores Bucales , Redes Neurales de la Computación , Reproducibilidad de los Resultados , Máquina de Vectores de Soporte
6.
JAMA Neurol ; 76(1): 35-40, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30383097

RESUMEN

Importance: Young mouse plasma restores memory in aged mice, but, to our knowledge, the effects are unknown in patients with Alzheimer disease (AD). Objective: To assess the safety, tolerability, and feasibility of infusions of young fresh frozen plasma (yFFP) from donors age 18 to 30 years in patients with AD. Design, Setting, and Participants: The Plasma for Alzheimer Symptom Amelioration (PLASMA) study randomized 9 patients under a double-blind crossover protocol to receive 4 once-weekly infusions of either 1 unit (approximately 250 mL) of yFFP from male donors or 250 mL of saline, followed by a 6-week washout and crossover to 4 once-weekly infusions of an alternate treatment. Patients and informants were masked to treatment and subjective measurements. After an open-label amendment, 9 patients received 4 weekly yFFP infusions only and their subjective measurements were unmasked. Patients were enrolled solely at Stanford University, a tertiary academic medical center, from September 2014 to December 2016, when enrollment reached its target. Eighteen consecutive patients with probable mild to moderate AD dementia, a Mini-Mental State Examination (score of 12 to 24 inclusive), and an age of 50 to 90 years were enrolled. Thirty-one patients were screened and 13 were excluded: 11 failed the inclusion criteria and 2 declined to participate. Interventions: One unit of yFFP from male donors/placebo infused once weekly for 4 weeks. Main Outcome and Measures: The primary outcomes were the safety, tolerability, and feasibility of 4 weekly yFFP infusions. Safety end point analyses included all patients who received the study drug/placebo. Results: There was no difference in the age (mean [SD], 74.17 [7.96] years), sex (12 women [67%]), or baseline Mini-Mental State Examination score (mean [SD], 19.39 [3.24]) between the crossover (n = 9) and open-label groups (n = 9). There were no related serious adverse events. One patient discontinued participation because of urticaria and another because of an unrelated stroke. There was no statistically significant difference between the plasma (17 [94.4%]) and placebo (9 [100.0%]) cohorts for other adverse events, which were mild to moderate in severity. The most common adverse events in the plasma group included hypertension (3 [16.7%]), dizziness (2 [11.1%]), sinus bradycardia (3 [16.7%]), headache (3 [16.7%]), and sinus tachycardia (3 [16.7%]). The mean visit adherence (n = 18) was 86% (interquartile range, 87%-100%) and adherence, accounting for a reduction in the total visit requirement due to early patient discontinuation, was 96% (interquartile range, 89%-100%). Conclusions and Relevance: The yFFP treatment was safe, well tolerated, and feasible. The study's limitations were the small sample size, short duration, and change in study design. The results warrant further exploration in larger, double-blinded placebo-controlled clinical trials. Trial Registration: ClinicalTrials.gov Identifier: NCT02256306.


Asunto(s)
Enfermedad de Alzheimer/terapia , Transfusión de Componentes Sanguíneos/métodos , Plasma , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Transfusión de Componentes Sanguíneos/efectos adversos , Estudios Cruzados , Método Doble Ciego , Estudios de Factibilidad , Femenino , Humanos , Masculino , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA