Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cardiol J ; 26(3): 233-240, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29611164

RESUMEN

BACKGROUND: Devices currently used to achieve hemostasis of the femoral artery following percutaneous cardiac catheterization are associated with vascular complications and remnants of artificial materials are retained at the puncture site. The Secure arterial closure Device induces hemostasis by utilizing thermal energy, which causes collagen shrinking and swelling. In comparison to established devices, it has the advantage of leaving no foreign material in the body following closing. This study was designed to evaluate the efficacy and safety of the Secure Device to close the puncture site following percutaneous cardiac catheterization. METHODS: The Secure Device was evaluated in a prospective non-randomized single-center trial with patients undergoing 6 F invasive cardiac procedures. A total of 67 patients were enrolled and the device was utilized in 63 patients. Fifty diagnostic and 13 interventional cases were evaluated. Femoral artery puncture closure was performed immediately after completion of the procedure. Time to hemostasis (TTH), time to ambulation (TTA) and data regarding short-term and 30-day clinical follow-up were recorded. RESULTS: Mean TTH was 4:30 ± 2:15 min in the overall observational group. A subpopulation of patients receiving anticoagulants had a TTH of 4:53 ± 1:43 min. There were two access site complications (hematoma > 5 cm). No major adverse events were identified during hospitalization or at the 30 day follow-up. CONCLUSIONS: The new Secure Device demonstrates that it is feasible in diagnostic and interventional cardiac catheterization. With respect to safety, the Secure Device was non-inferior to other closure devices as tested in the ISAR closure trial.


Asunto(s)
Cateterismo Periférico , Arteria Femoral , Hemorragia/prevención & control , Técnicas Hemostáticas/instrumentación , Anciano , Austria , Cateterismo Cardíaco , Cateterismo Periférico/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Arteria Femoral/diagnóstico por imagen , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Punciones , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA